Jefferson Lab: Present and Future

The Continuous Electron Beam Accelerator Facility (CEBAF) and associated experimental equipment at Jefferson Lab (JLab) comprise a unique facility for nuclear physics research whose upgrade is presently underway, with completion expected in 2017. The upgraded facility will accelerate electron beams to 11 GeV for experiments in the existing Halls A, B and C. In addition, a 12 GeV beam can be provided to a new experimental hall, Hall D, to generate a 9 GeV tagged photon beam. This upgrade will enable a new experimental program with substantial discovery potential to address important topics in hadronic, nuclear, and electroweak physics. Further in the future, it is envisioned that the Laboratory will evolve into an electron-ion colliding beam facility (EIC).

Rossi, Patrizia↗

Baryon spectroscopy with polarization observables from CLAS

The spectrum of nucleon excitations is dominated by broad and overlapping resonances. Polarization observables in photoproduction reactions are key in the study of these excitations. They give indispensable constraints to partial-wave analyses and help clarify the spectrum. A series of polarized photoproduction experiments have been performed at the Thomas Jefferson National Accelerator Facility with the CEBAF Large Acceptance Spectrometer (CLAS). These measurements include data with linearly and circularly polarized tagged-photon beams, longitudinally and transversely polarized proton and deuterium targets, and recoil polarizations through the observation of the weak decay of hyperons. An overview of these studies and recent results will be given.

Strauch, Steffen↗

Study of the Few Nucleon Systems at $\mathrm{CLAS}$

The study of few nucleon systems with electromagnetic probes is an essential component of the scientific program carried out at the Thomas Jefferson National Accelerator Facility (JLab). Here we present measurements of exclusive reactions on light nuclei using real photon beams with energies up to 3 GeV and the CEBAF Large Acceptance Spectrometer (CLAS), a nearly 4π magnetic spectrometer, in order to study the properties of strongly interacting matter and the transition from hadronic (i.e in terms of nucleons and mesons) to partonic (in terms of quark and gluons) degrees of freedom in nuclear interactions. We discuss the progress made in understanding the relevant degrees of freedom using polarisation observables and cross sections of deuteron and 3 He photodisintegration in the few-GeV photon-energy region. In addition, recent high-statistics experiments with the CLAS detector have provided us with sufficient counting rates to study the effects of initial- and final-state interactions in reactions off the deuteron. Such data allow us to extract a large set of polarisation observables for final-state interactions in hyperon photoproduction and to study the properties of the hyperon–nucleon interaction. Initial-state effects are studied by mapping the dependence of experimental observables on the spectator-nucleon momentum. We also present recent results for polarisation observables for quasi-free K + Λ off the bound proton in a deuteron as well as for final-state interactions in the reaction γd→K + Λn , and will discuss their impact on hyperon–nucleon studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The GlueX Experiment: First Results

GlueX is a nuclear physics experiment located at the Thomas Jefferson National Accelerator Facility designed to study and understand the nature of confinement in QCD by mapping the spectrum of exotic mesons. The experiment will be able to probe new areas by using photoproduction, i.e. the scattering on nucleon of ~9 GeV linearly polarized photons derived from the recently upgraded CEBAF with a 12 GeV electron beam. Spring 2016 has been characterized by a continued detector commissioning and initial running at the full design energy. The current status of the GlueX detector performance and data collection will be discussed, with a brief overview of first physics results, future run plans, and long term upgrades.

Fanelli, Cristiano (ORCID:0000000219851329)↗

Nucleon form factor studies at Jlab

The ratio of the electromagnetic proton elastic form factors, GpE/GpM, has been measured at Jefferson Lab up to View the MathML source, by using the CEBAF 6 GeV electron beam, and revealing an unexpected and challenging physical behaviour. The 2014 scheduled 12 GeV upgrade will allow the measurement of GpE/GpM up to View the MathML source, by taking advantage of the new large-acceptance forward spectrometer Super BigBite (SBS) in Hall A. Measurements of neutron form factors in the region around 10 (GeV/c)2, where quark confinement plays an important role, are expected to show the behaviour already observed in the proton case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Horizontal 1 K refrigerator with novel loading mechanism for polarized solid targets

We describe a helium evaporation refrigerator used to cool dynamically polarized proton and deuteron targets for electron-scattering experiments using the CEBAF Large Acceptance Spectrometer CLAS12 at Jefferson Lab. The geometry of the CLAS12 detector systems places severe design and construction constraints on the refrigerator and its ancillary equipment, resulting in a horizontal cryostat with a length of 4 m. The 16 cm 3 target samples, consisting of frozen ammonia (NH 3 or ND 3 ), are loaded at the upstream end of the cryostat and moved to the beam-interaction region using a novel transport mechanism. At this location they are cooled with superfluid helium and polarized via dynamic nuclear polarization at 1 K and 5 T. In this manner samples can be replaced and cooled to 1 K in about 30 minutes without disturbing any elements of the electron beam line or particle detection system. In conclusion, we estimate that this method saved 18 days of valuable beam time over the course of a recent, 88-day long experiment.

Evaporation refrigerator↗

Micromegas tracker project for CLAS12

Micromegas detectors on bulk are used in a new design of the central tracker for the future Cebaf Large Acceptance Spectrometer 12 (CLAS12) in Hall B at Jefferson Lab. Expected performances and mechanical designs are shown for this cylindrical detector. First tests in moderate magnetic field up to 1.5 T, using a laser source, are in good agreement with simulations.

Micro Pattern Gaseous Detectors↗

Operation of a high-gradient superconducting radio-frequency cavity with a non-evaporable getter pump

The use of non-evaporable getter (NEG) pumps in particle accelerators has increased significantly over the past few years because of their large pumping speed, particularly for hydrogen, compared to the size of the pump. A concern about using such pumps in superconducting radio-frequency (SRF) accelerators is the possibility of shedding particulates which could then migrate into the SRF cavities and produce field emission, therefore degrading the cavity performance. One option to mitigate such issue is to use sintered getter materials which intrinsically offer superior mechanical and particle retention properties. In this article we present the results from cryogenic RF tests of a high-gradient SRF cavity after being evacuated several times with an NEG pump equipped with sintered getter disks and placed in close proximity to the cavity. Here, the results showed that the cavity performance was not affected by the pump up to the quench gradient of 34 MV/m. As a result of this study, two such NEG pumps have been installed next to a cryomodule in the CEBAF accelerator to maintain ultra-high vacuum in the SRF cryomodule and two adjacent warm girder sections.

43 PARTICLE ACCELERATORS↗

Enhanced UV light detection using a p-terphenyl wavelength shifter

Here, UV-glass photomultiplier tubes (PMTs) have poor photon detection efficiency for wavelengths below $300\,\text{nm}$ due to the opaqueness of the window material. Costly quartz PMTs could be used to enhance the efficiency below $300\,\text{nm}$. A less expensive solution that dramatically improves this efficiency is the application of a thin film of a p-terphenyl (PT) wavelength shifter on UV-glass PMTs. This improvement was quantified for Photonis XP4500B PMTs for wavelengths between $200\,\text{nm}$ and $400\,\text{nm}$. The gain factor ranges up to 5.4 $\pm$ 0.5 at a wavelength of $215\,\text{nm}$, with a material load of $110\pm10\,\mu\text{g}/\text{cm}^2$ ($894\,\text{nm}$). The wavelength shifter was found to be fully transparent for wavelengths greater than $300\,\text{nm}$. The resulting gain in detection efficiency, when used in a typical Cherenkov counter, was estimated to be of the order of 40%. Consistent coating quality was assured by a rapid gain testing procedure using narrow-band UV LEDs. Based on these results, 200 Photonis XP4500B PMTs were treated with PT for the upgraded low-threshold Cherenkov counter (LTCC) to be used in the CEBAF Large Acceptance Spectrometer upgraded detector (CLAS12) at the Thomas Jefferson National Accelerator Facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A radial time projection chamber for α detection in CLAS at JLab

A new Radial Time Projection Chamber (RTPC) was developed at the Jefferson Laboratory to track low-energy nuclear recoils to measure exclusive nuclear reactions, such as coherent deeply virtual Compton scattering and coherent meson production off 4 He. In 2009, we carried out these measurements using the CEBAF Large Acceptance Spectrometer (CLAS) supplemented by the RTPC positioned directly around a gaseous 4 He target, allowing a detection threshold as low as 12 MeV for 4 He. This work discusses the design, principle of operation, calibration methods and performances of this RTPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 drift chamber system

The CEBAF Large Acceptance Spectrometer at 12~GeV (CLAS12) is located in Hall~B, one of the experimental halls at Jefferson Lab. The forward part of CLAS12 is built around a superconducting toroidal magnet. The six coils of the toroid divide the detector azimuthally into six sectors. Each sector contains three multi-layer drift chambers for reconstructing the trajectories of charged particles originating from a fixed target. Each of the 18 planar chambers has two ``superlayers'' of six layers each, with the wires in the two adjacent superlayers oriented at ± 6° stereo angles. Each layer has 112 hexagonal cells spanning a range from about 5° to 40° in polar angle. The six-layer structure provides redundancy in track segment finding and good tracking efficiency even in the presence of some individual wire inefficiency. The design, construction, operation, and calibration methods are described, and estimates of the efficiency and resolution are presented from in-beam measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status and performance of the GlueX DIRC

In support of the future physics program at Ce+BAF, we propose a prototype positron target. The prototype target consists of a tungsten disk mounted on a water-cooled copper support structure to enhance heat removal. The primary goals of this work are to benchmark CFD simulations, ensure vacuum integrity at the 10^-6 Pa level, achieve stable target rotation up to 10 Hz, and implement efficient water-based cooling for sustained high-power operation. To manage the thermal load, the target is designed to rotate, allowing the deposited heat to spread over a larger region, and thereby reducing localized thermal stress while maintaining the maximum temperature below 1000 K. To experimentally evaluate the thermal performance and structural stability of the target, we plan to conduct high-power laser heating tests at Laser Lab 5, LERF Building, JLab. These tests will serve as a stepping-stone for the positron production target at CEBAF.

Stevens, J.R. [College of William and Mary, Willia↗

Detector development for Jefferson Lab's 12GeV Upgrade

Jefferson Lab will soon finish its highly anticipated 12 GeV Upgrade. With doubled maximum energy, Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) will enable a new experimental program with substantial discovery potential, addressing important topics in nuclear, hadronic and electroweak physics. In order to take full advantage of the high energy, high luminosity beam, new detectors are being developed, designed and constructed to fit the needs of different physics topics. The paper will give an overview of various new detector technologies to be used for 12 GeV experiments. It will then focus on the development of two solenoid-based spectrometers, the GlueX and SoLID spectrometers. The GlueX experiment in Hall D will study the complex properties of gluons through exotic hybrid meson spectroscopy. The GlueX spectrometer, a hermetic detector package designed for spectroscopy and the associated partial wave analysis, is currently in the final stage of construction. Hall A, on the other hand, is developing the SoLID spectrometer to capture the 3D image of the nucleon from semi-inclusive processes and to study the intrinsic properties of quarks through mirror symmetry breaking. Such a spectrometer will have the capability to handle very high event rates while still maintaining a large acceptance in the forward region.

43 PARTICLE ACCELERATORS↗

Transition Form Factor from CLAS

The excitation of nucleon resonances in electromagnetic interaction has long been studied. The study of resonances helps us to understand the long- and short- range structures of the nucleon and its excited states in terms of quark confinement. While the existing data of the low-lying resonances are consistent with the well-studied SU(6) circle times operator O(3) constituent quark model classification, many open questions still remain. Exclusive electro-production is one of the best ways to investigate nucleon resonances. The exclusive electro-production process View the MathML source was measured in the photon virtuality range Q2 = 1.7 â 4.5 GeV2 and the invariant mass range for the n?+ system of W = 1.15 â 1.7 GeV using the CEBAF Large Acceptance Spectrometer. For the first time, these kinematics are probed in exclusive ?+ production from protons with nearly full coverage in the azimuthal and polar angles of the n?+ center-of-mass system. The n?+ channel has particular sensitivity t

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generalized parton distributions at CLAS

The understanding of the hadron structure in terms of QCD degrees of freedom is one of the main challenges of hadron physics. Indeed, despite the large amount of theoretical and experimental activity devoted to the subject in the last years, a full comprehension of mesons and baryons in terms of quark and gluon fields is still lacking. In order to operate a more detailed investigation of the hadron structure, new quantities have been introduced ten years ago, the Generalized Parton Distributions (GPDs), defined as bilocal, off-forward matrix elements of quark and gluon operators. From an experimental point of view, GPDs are accessible through two main processes: Deeply Virtual Compton Scattering (DVCS) and Deeply Virtual Meson Electroproduction (DVMP). Depending on the polarization degrees of freedom acting in the process (like, for example, the simultaneous presence of a polarization in the beam and in the target, or the usage of a polarized beam with an unpolarized target), various combinations of GPDs can be accessed. In the case of DVCS, for example, the measurement of the Single Spin Asymmetry of processes like View the MathML source – realized by using a longitudinally polarized target - gives access to a combination of the GDPs H and H̃. The CEBAF Large Acceptance Spectrometer (CLAS) installed in the Hall-B at JLab, is particularly suited for the extraction of these quantities. Its large acceptance implies a good capability in the reconstruction of exclusive final states, allowing the investigation of the aforementioned processes in a wide range of kinematics. In this presentation, an overview of the main GPD measurements performed by CLAS will be given. In particular, the first DVCS measurements realized both with unpolarized and polarized target, together with the measurements of some exclusive meson electroproduction processes, will be described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing the nucleon structure with SIDIS at Jefferson Lab

In recent years, measurements of azimuthal moments of polarized hadronic cross sections in hard processes have emerged as a powerful tool to probe nucleon structure. Many experiments worldwide are currently trying to pin down various effects related to nucleon structure through Semi-Inclusive Deep-Inelastic Scattering (SIDIS). Azimuthal distributions of final-state particles in semi-inclusive deep inelastic scattering, in particular, are sensitive to the orbital motion of quarks and play an important role in the study of Transverse Momentum Dependent parton distribution functions (TMDs) of quarks in the nucleon. The CLAS spectrometer, installed in Hall-B at Jefferson Lab, has collected semi-inclusive data using the CEBAF 6 GeV polarized electron beam on polarized solid NH{sub 3} and ND{sub 3} targets. An overview of these measurements is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hyperon Production with CLAS and CLAS12

Hadron spectroscopy and baryon spectroscopy in particular represents a large part of the experimental program with CLAS at Jefferson Lab. Within this program a substantial amount of data on hyperon production and properties has been accumulated. This includes photo- and electro-production of {Lambda} and {Sigma} hyperons and their excited states and also {Xi} hyperons. Some of the highlights of this program will be presented together with plans to extend this program with CLAS12 after CEBAF upgrade to 12 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Moments of the Spin Structure Functions g1p and g1d for 0.05 < Q2 < 3.0 GeV2

The spin structure functions $g_1$ for the proton and the deuteron have been measured over a wide kinematic range in $x$ and \Q2 using 1.6 and 5.7 GeV longitudinally polarized electrons incident upon polarized NH$_3$ and ND$_3$ targets at Jefferson Lab. Scattered electrons were detected in the CEBAF Large Acceptance Spectrometer, for $0.05 < Q^2 < 5 $\ GeV$^2$ and $W < 3$ GeV. The first moments of $g_1$ for the proton and deuteron are presented -- both have a negative slope at low \Q2, as predicted by the extended Gerasimov-Drell-Hearn sum rule. The first result for the generalized forward spin polarizability of the proton $\gamma_0^p$ is also reported, and shows evidence of scaling above $Q^2$ = 1.5 GeV$^2$. Although the first moments of $g_1$ are consistent with Chiral Perturbation Theory (\ChPT) calculations up to approximately $Q^2 = 0.06$ GeV$^2$, a significant discrepancy is observed between the $\gamma_0^p$ data and \ChPT\ for $\gamma_0^p$,even at the lowest \Q2.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗