Search NASA⌕ Search

SEARCH · Search NASA

Results for “COLLECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Concentrating solar collector-performance tests

Report summarizes test results from evaluation of concentrating solar collector thermal performance, from transient behavior, and incident-of-angle behavior. Tests were conducted using National Bureau of Standards recommedations and specifications.

Source record↗

Pointing errors in solar dish collectors

Mathematical analysis calculates effects of transient pointing errors in solar dish collectors treating each pointing error separately. This approach considerably simplifies programming of simulation models for tracking drive, wind effects, and other design parameters.

Hughes, R. O.↗

Performance evaluation of a liquid solar collector

Report describes thermal performance and structural-load tests on commercial single glazed flat-plate solar collector with gross area of 63.5 sq ft that uses water as heat-transfer medium. Report documents test instrumentation and procedures and presents data as tables and graphs. Results are analyzed by standard data-reduction methods.

Source record↗

Concentric-tube solar collector

Brochure contains design, performance, and installation information for commercial concentric-tube solar collector.

Source record↗

Development of nonmetallic solar collector and solar-powered pump

Design and building of two unique components for solar heating (1. flatplate solar collector using no metal components, and 2. solar powered pump for heating and cooling systems are outlined in report. Report also discusses hardware, deliverable end items, problems encountered during fabrication and testing, and performance certification.

Parker, J. C.↗

Liquid solar collector

Report documents evaluation test on commercial flat-plate solar collector that uses water as working fluid. Performance was measured before and after 34-day exposure to natural environment. Tables in metric and English units present data on air and water temperatures, waterflow, insolation, efficiency, and windspeed and direction.

Source record↗

Final report on the concentric-tube solar collector

Report documents 26-month program to optimize performance of commercial high performance concentric tube solar collector. Report discusses program objectives, accomplishments, encountered problems, and final hardware. Certification test results are also included.

Parker, J. C.↗

Certification of the concentrating solar collector

Report describes procedures and results of extensive testing of concentrating solar collector performed for certification of systems compliance with government performance standards. Test includes operational, electrical, mechanical, and thermal checks, as well as structural integrity.

Source record↗

Concentrating solar collector - final design

Final report of program to improve commercially available concentrating solar collector describes final hardware, discusses problems encountered, and presents certification statements, photographs, and recommendations for modification.

Parker, J. C.↗

Testing of a solar collector with concentrating mirrors

Commerical flat-plate solar collector with concentrating mirrors has been tested for thermal performance, structured behavior under static load, and effects of long-term natural weathering. Report documents results of testing and concludes that absorptivity was degraded by weathering.

Source record↗

Non-tracking solar energy collector system

A solar energy collector system is described characterized by an improved concentrator for directing incident rays of solar energy on parallel strip-like segments of a flatplate receiver. Individually mounted reflector modules of a common asymmetrical triangular cross-sectional configuration supported for independent orientation are asymmetric included with vee-trough concentrators for deflecting incident solar energy toward the receiver.

Selcuk, M. K.↗

Solar cell collector and method for producing same

A transparent, conductive collector layer containing conductive metal channels is formed as a layer on a photovoltaic substrate by coating a photovoltaic substract with a conductive mixed metal layer. A heat sink having portions protruding from one of its surfaces is attached. These protruding portions define a continuous pattern in combination with recessed regions among them such that they are in contact with the conductive layer of the photovoltaic substrate. Heating the substrate while simultaneously oxidizing the portions of the conductive layer exposed to a gaseous oxidizing substance forced into the recessed regions of the heat sink, creates a transparent metal oxide layer on the substrate. A continous pattern of highly conductive metal channels is contained in the metal oxide layer.

Evans, J. C., Jr.↗

Preliminary design package for Sunair SEC-601 solar collector

The preliminary design of the Owens-Illinois model Sunair SEC-601 tubular air solar collector is presented. Information in this package includes the subsystem design and development approaches, hazard analysis, and detailed drawings available as the preliminary design review.

Source record↗

A fixed tilt solar collector employing reversible vee-through reflectors and evaluated tube receivers for solar heating and cooling systems

The Vee-Trough/Evacuated Tube Collector (VTETC) was analyzed rigorously and various mathematical models were developed to calculate the optical performance of the vee-trough concentrators, and the quasi-steady state thermal performance of the evacuated tube receivers. Tests were run to verify the mathematical analyses. Back-silvered glass mirror, Alzak, Aluminized Teflon, and Kinglux (electropolished aluminum reflectors) were tested. Additional tests were run at temperatures ranging from 80 to 190 C (176-374 F). For the glass mirror reflectors, peak efficiencies, based on aperture area and operating temperatures of 125 C (257 F), were over 40%. Efficiencies of about 40% were observed at temperatures of 150 C (302 F) and 30% at 175 C (347 F). Test data for several days, predicted daily useful heats, and efficiency values are presented for a full year. These theoretical values were then compared with actual data points for the same temperature range.

Selcuk, M. K.↗

Development, testing, and certification of the Northrup, Inc., ML series concentrating solar collector model NSC-01-0732

A summary is presented of the additional development work on the existing ML Series concentrating solar collector for use with solar heating and cooling systems. The report discusses the intended use of the final report, describes the development hardware, lists deliverable end items, deals with problems encountered during fabrication and testing, and includes certification statements of performance. This report shows that the products developed are marketable and suitable for public use.

Parker, J. C.↗

Development, testing, and certification of Owens-Illinois model SEC-601 solar energy collector system

The final results are presented of the additional development work on the existing air-cooled solar energy collector subsystem for use with solar heating and cooling systems. The report discusses the intended use of the final report, describes the deliverable end items, lists program objectives, relates how they were accomplished, deals with problems encountered during fabrication and testing, and includes a certification statement of performance. The report shows that the products developed are marketable and suitable for public use.

Parker, J. C.↗