Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMPRESSORS - BLADES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Analytical and experimental studies of acoustic performance of segmented liners in a compressor inlet

The performance of axially segmented (phased) acoustic treatment liners in the inlet of a compressor was investigated. Topics discussed include: (1) the validation of a theoretical procedure to predict propagation and suppression characteristics of duct liners; (2) the in-duct measurement of spinning modes; (3) investigation of phased treatment designs; (4) high Mach inlet acoustic tests; and (5) an experimental investigation of inlet turbulence. The analytical prediction for the multi-segmented treatment was found to provide the correct order of magnitude of suppression and was generally within 50% of that determined experimentally. Refinements required to improve the correlation are identified. Suppression due to high subsonic Mach number flow effects was found to become significant above an average throat Mach number of 0.65 to 0.7 and 20 PNdB was achieved with an average throat Mach number in the range of 0.80 to 0.85. For the measured turbulence in the inlet, including the axial and circumferential turbulence intensities and the axial integral length scale, data are presented with and without an inlet screen showing that the screen reduced the turbulence intensities and that the BPF noise was reduced as a consequence.

Motsinger, R. E.↗

Simplified data compressor

Image data are compressed for transmission by simple, economical circuitry. Compressor handles data in blocks of 64 samples. Mean from previous line is subtracted, and pseudo-random sequence of positive and negative 1's multiplies samples of each block. Hadamard transform applied to blocks yields 64 transform coefficients. Each coefficient is compared with approximation to corresponding coefficient of previous line, and difference is quantized. Values are transmitted or stored. Procedure is reversed to reproduce image.

Rice, R. F.↗

Experimental clean combustor program: Turbulence characteristics of compressor discharge flows

The results of turbulence measurements at the entrance to the diffuser duct of a large gas turbine are presented. Hot film and hot wire measurements were conducted over a compressor discharge temperature range of 450K to 608K. It was found that the turbulent intensity at the I.D. and midspan locations increases gradually from 6 + or - 1 percent at idle to 7 + or - 1 percent at approach; the turbulent intensity at the O.D. location increases from 7.5 + or - 0.5 percent at idle to 15 + or - 0.5 percent at approach. The energy in the velocity waves is uniformly distributed over a 0.1 to 5 kHz bandwidth, and the cut-off frequency is not a strong function of the engine operation. The axial length of the Fourier components within this bandwidth varies from 0.021 to 1.05m. The turbulence near the diffuser O.D. is of sufficient amplitude and scale to affect the flow to the front end sections of the burner.

Follansbee, P. S.↗

Investigation of the jet-wake flow of a highly loaded centrifugal compressor impeller

Investigations, aimed at developing a better understanding of the complex flow field in high performance centrifugal compressors were performed. Newly developed measuring techniques for unsteady static and total pressures as well as flow directions, and a digital data analysis system for fluctuating signals were thoroughly tested. The loss-affected mixing process of the distorted impeller discharge flow was investigated in detail, in the absolute and relative system, at impeller tip speeds up to 380 m/s. A theoretical analysis proved good coincidence of the test results with the DEAN-SENOO theory, which was extended to compressible flows.

Eckardt, D.↗

Cold-air performance of the compressor-drive turbine of the Department of Energy baseline automobile gas-turbine engine

The aerodynamic performance of the compressor-drive turbine of the DOE baseline gas-turbine engine was determined over a range of pressure ratios and speeds. In addition, static pressures were measured in the diffusing transition duct located immediately downstream of the turbine. Results are presented in terms of mass flow, torque, specific work, and efficiency for the turbine and in terms of pressure recovery and effectiveness for the transition duct.

Roelke, R. J.↗

Design and overall performance of four highly loaded, high speed inlet stages for an advanced high-pressure-ratio core compressor

The detailed design and overall performances of four inlet stages for an advanced core compressor are presented. These four stages represent two levels of design total pressure ratio (1.82 and 2.05), two levels of rotor aspect ratio (1.19 and 1.63), and two levels of stator aspect ratio (1.26 and 1.78). The individual stages were tested over the stable operating flow range at 70, 90, and 100 percent of design speeds. The performances of the low aspect ratio configurations were substantially better than those of the high aspect ratio configurations. The two low aspect ratio configurations achieved peak efficiencies of 0.876 and 0.872 and corresponding stage efficiencies of 0.845 and 0.840. The high aspect ratio configurations achieved peak ratio efficiencies of 0.851 and 0.849 and corresponding stage efficiencies of 0.821 and 0.831.

Reid, L.↗

Effect of number of probes and their orientation on the calculation of several compressor face distortion descriptors

A study was performed to determine the effects of the number and position of total pressure probes on the calculation of five compressor face distortion descriptors. This study used three sets of 320 steady state total pressure measurements that were obtained with a special rotating rake apparatus in wind tunnel tests of a mixed-compression inlet. The inlet was a one third scale model of the inlet on a YF-12 airplane, and it was tested in the wind tunnel at representative flight conditions at Mach numbers above 2.0. The study shows that large errors resulted in the calculation of the distortion descriptors even with a number of probes that were considered adequate in the past. There were errors as large as 30 and -50 percent in several distortion descriptors for a configuration consisting of eight rakes with five equal-area-weighted probes on each rake.

Stoll, F.↗

Turbulence characteristics of compressor discharge flows

Turbulence measurements were conducted in a large gas turbine engine (JT9D) at the entrance to the diffuser duct, joining the compressor discharge to the combustor inlet. Hot film probe and hot wire probe measurements were obtained at temperatures from 450K (350F) (idle) to 608K (635F) (rich approach). At I.D. (25 percent span) and mid-span locations, the turbulence intensity increased slightly from 6 + or - percent at idle condition to 7 or - 1 percent at rich approach. At O.D. (75 percent span) the turbulent intensity increased more rapidly, from 7.5 + or - 0.5 percent at idle to 15 + or - 0.5 percent at rich approach. The spectra showed turbulent energy distributed uniformly over a 0.1 to 5 KHz bandwidth (down 3db) at all operating conditions, corresponding to random turbulence with velocity wave lengths of 2 cm to 1 meter travelling at the mean velocity of 100 m/sec. Tests results are given in tables and graphs.

Grant, H. P.↗

Turbulence measurements in the compressor exit flow of a General Electric CF6-50 engine

Ruggedized cooled film probes were used to measure CF6-50 compressor exit turbulence properties at three different engine idle condition test points. The turbulence probe was coupled to a constant temperature anemometer and signal conditioning system. An on-line readout system connected to the anemometer was used to check the data as it was acquired. At engine idle conditions, the turbulence intensity ranged from 4.8 percent to 5.6 percent and the length scale ranged from 5.64 cm to 6.95 cm. The length scale values are somewhat larger than the passage height at the measurement plane (5.54 cm), which indicates that the shape of the turbulent eddies are elongated in the axial direction. The microscale values range from about 0.73 cm to about 0.98 cm. Power spectral density distributions show that a large proportion of the turbulent energy at the measurement plane is concentrated at frequencies below one kilohertz.

Taylor, J. R.↗

Shock structure in transonic compressor rotors

The inadequacy of axisymmetric theory in modeling the structure of the shock system in a transonic compressor rotor is shown with a simple model. A more accurate model for the flow near the sonic radius is proposed, which is supported by some flow visualization data and three-dimensional computations.

Epstein, A. H.↗

Abradable compressor and turbine seals, volume 1

The application and advantages of abradable coatings as gas-path seals in a general aviation turbine engine were evaluated for use on the high-pressure compressor, the high-pressure turbine, and the low-pressure turbine shrouds. Topics covered include: (1) the initial selection of candidate materials for interim full-scale engine testing; (2) interim engine testing of the initially selected materials and additional candidate materials; (3) the design of the component required to adapt the hardware to permit full-scale engine testing of the most promising materials; (4) finalization of the fabrication methods used in the manufacture of engine test hardware; and (5) the manufacture of the hardware necessary to support the final full-scale engine tests.

Sundberg, D. V.↗

Subsynchronous instability of a geared centrifugal compressor of overhung design

The original design analysis and shop test data are presented for a three stage (poster) air compressor with impellers mounted on the extensions of a twin pinion gear, and driven by an 8000 hp synchronous motor. Also included are field test data, subsequent rotor dynamics analysis, modifications, and final rotor behavior. A subsynchronous instability existed on a geared, overhung rotor. State-of-the-art rotor dynamics analysis techniques provided a reasonable analytical model of the rotor. A bearing modification arrived at analytically eliminated the instability.

Hudson, J. H.↗

Effect of fluid forces on rotor stability of centrifugal compressors and pumps

A simple two dimensional model for calculating the rotordynamic effects of the impeller force in centrifugal compressors and pumps is presented. It is based on potential flow theory with singularities. Equivalent stiffness and damping coefficients are calculated for a machine with a vaneless volute formed as a logarithmic spiral. It is shown that for certain operating conditions, the impeller force has a destablizing effect on the rotor.

Colding-Jorgensen, J.↗

Comparison between optical measurements and a numerical solution of the flow field within a transonic axial-flow compressor rotor

A comparison between numerical and experimental results is presented for the flowfield within a transonic axial-flow compressor rotor. The rotor was tested at design speed and a wide open throttle discharge condition. The relative tip Mach number was 1.4. A laser anemometer system was used to measure velocity and flow angle upstream, within, and downstream of the rotor. A holographic interferometer was used to visualize the rotor shock system near the tip. The computational procedure solves the full three-dimensional Euler equations using a time-marching technique. Shock location and shape determined from the two optical systems are compared. Calculated relative Mach number and flow angle contours, shock locations, and shock strength are compared to values measured with the laser anemometer.

Strazisar, A. J.↗

Abradable compressor and turbine seals, volume 2

The applications and advantages of abradable coatings as gas path seals in a general aviation turbofan engine were investigated. Abradable materials were evaluated for the high pressure radial compressor and the axial high and low pressure turbine shrouds.

Sundberg, D. V.↗

Cold-air performance of compressor-drive turbine of Department of Energy upgraded automobile gas turbine engine. 1: Volute-manifold and stator performance

The aerodynamic performance of the inlet manifold and stator assembly of the compressor drive turbine was experimentally determined with cold air as the working fluid. The investigation included measurements of mass flow and stator-exit fluid torque as well as radial surveys of total pressure and flow angle at the stator inlet and annulus surveys of total pressure and flow angle at the stator exit. The stator-exit aftermixed flow conditions and overall stator efficiency were obtained and compared with their design values and the experimental results from three other stators. In addition, an analysis was made to determine the constituent aerodynamic losses that made up the stator kinetic energy loss.

Roelke, R. J.↗

Comparison of two and three dimensional flow computations with laser anemometer measurements in a transonic compressor rotor

A procedure for using an efficient axisymmetric code to generate downstream pressure input for more costly Euler codes is discussed. Two and three dimensional inviscid solutions for the flow within a transonic axial compressor rotor at design speed are compared to laser anemometer measurements at maximum flow and near stall operating points. Computational details of the 2-D axisymmetric stream function solution and the 3-D full Euler solution are described. Relative Mach number contours, shock location, and shock strength as measured and as predicted by the 3-D code are compared. Downstream of the rotor the inviscid computations agree with each other but predict higher pressure ratios than those measured. Euler codes require a downstream pressure as input. Since that pressure controls the computed mass flow and shock system, it must be consistent with an inviscid solution.

Chima, R. V.↗