Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONTINUOUS WAVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

The measurement of meteor winds over Atlanta /34 N, 84 W/

An all-sky, continuous wave radio meteor wind facility has been installed in Atlanta. A double sideband suppressed carrier CW transmitter, operating at around 32.5 MHz, with an rms output of 2 kW, has been installed, and a receiving site was established at 27 km away. Details of the equipment, together with height/time profiles of mean wind circulation and tides between 80 and 100 km, measured from August 9 to September 4, 1974, are presented.

Roper, R. G.↗

DSS 14 X-band radar feedcone

A high-power 400-kW continuous-wave (CW) X-band radar feed system was described for use with the Goldstone, California, 64-m DSS 14 antenna system. Design considerations, their solutions, and final system testing are discussed. The radar system, unique in terms of antenna size, radiated power, and efficiency, became operational in December 1974.

Neff, D. E.↗

Development of a laser Doppler system for the detection and monitoring of atmospheric disturbances

A Scanning Laser Doppler Velocimeter System (SLDVS) capable of detecting and monitoring atmospheric disturbances, including wake vortices of landing aircraft and vertical wind profiles in the atmosphere was developed. The SLDVS is a focused, continuous wave, CO2 system that determines the line-of-sight velocities of particles in the focal volume by measuring the Doppler shift created by these particles. At present, the SLDVS is designed to have a range coverage of approximately 2000 ft with a vertical angle coverage of approximately 60 deg. It is also designed to detect Doppler velocities of up to 200 ft/sec with a velocity resolution of approximately 1.8 ft/sec. A complete velocity spectrum is provided by the SLDVS at each point in space at which it is focused. The overall operation and performance of the system and the description of its individual components and data handling capabilities were given.

Jeffreys, H. B.↗

Application of high power lasers to space power and propulsion

The transmission of laser power over long distances for applications such as direct conversion to propulsive thrust or electrical power is considered. Factors discussed include: problems inherent in transmitting, propagating, and receiving the laser beam over long ranges; high efficiency, closed-cycle, continuous wave operation; advancement of CO2 laser technology; and compatibility with photovoltaic power conversion devices.

Nored, D. L.↗

Applications of Doppler ultrasound in clinical vascular disease

Doppler ultrasound has become the most useful and versatile noninvasive technique for objective evaluation of clinical vascular disease. Commercially available continuous-wave instruments provide qualitative and quantitative assessment of venous and arterial disease. Pulsed Doppler ultrasound was developed to provide longitudinal and transverse cross-sectional images of the arterial lumen with a resolution approaching that of conventional X-ray techniques. Application of Doppler ultrasound in venous, peripheral arterial, and cerebrovascular diseases is reviewed.

Barnes, R. W.↗

Visible GaAs/0.7/P/0.3/ CW heterojunction lasers

The paper reports the first low-threshold red-light-emitting heterojunction laser diodes consisting of lattice-matched Ga(As,P)/(In,Ga)P heteroepitaxial layers. A room-temperature threshold current of 3400 A/sq cm was obtained at a wavelength of about 7000 A; this value is substantially lower than those achieved at this wavelength with (Al,Ga)As lasers. For the first time, continuous-wave laser operation at temperatures as high as 10 C has been obtained for GaAs(1-x)P(x).

Kressel, H.↗

Improved "spectrophone"

Spectral lines of gas sample are modulated by electric field in optoacoustic gas analyzer. Pressure fluctuations caused by local heating of absorbing gas are picked up by microphone. Since laser is operated in continuous-wave (CW) mode, background noise due to heating of windows is eliminated.

Margolis, J. S.↗

Miniature velocimeter

Laser velocimeter (LV) designed to use semiconductor-diode laser is 100 times smaller than continuous-wave gas-laser velocimeter permitting mounting within wind-tunnel models or on engine walls. Mini LV uses only 0.4 watts of power and measures velocities with accuracy of 98% or better.

Franke, J. M.↗

Closed cycle electric discharge laser design investigation

Closed cycle CO2 and CO electric discharge lasers were studied. An analytical investigation assessed scale-up parameters and design features for CO2, closed cycle, continuous wave, unstable resonator, electric discharge lasing systems operating in space and airborne environments. A space based CO system was also examined. The program objectives were the conceptual designs of six CO2 systems and one CO system. Three airborne CO2 designs, with one, five, and ten megawatt outputs, were produced. These designs were based upon five minute run times. Three space based CO2 designs, with the same output levels, were also produced, but based upon one year run times. In addition, a conceptual design for a one megawatt space based CO laser system was also produced. These designs include the flow loop, compressor, and heat exchanger, as well as the laser cavity itself. The designs resulted in a laser loop weight for the space based five megawatt system that is within the space shuttle capacity. For the one megawatt systems, the estimated weight of the entire system including laser loop, solar power generator, and heat radiator is less than the shuttle capacity.

Baily, P. K.↗

The 1.1 micrometer and visible emission semiconductor diode lasers

In (AlGa)As, the first of three alloy systems studied, Continuous Wave (CW) operation was obtained at room temperature at a wavelength as low as 7260 A. Reliability in this system was studied in the incoherent mode. Zinc doped devices had significant degradation, whereas Ge or Ge plus Zi doped devices had none. The Al2O3 facet coatings were shown to significantly reduce facet deterioration in all types of lasers, longer wavelength units of that type having accumulated (at the time of writing) 22,000 hours with little if any degradation. A CL study of thin (AlGa)As layers revealed micro fluctuation in composition. A macro-scale fluctuation was observed by electroreflectance. An experimental and theoretical study of the effect of stripe width on the threshold current was carried out. Emission below 7000 A was obtained in VPE grown Ga(AsP) (In,Ga)P with CW operation at 10 C. Lasers and LED's were made by LPE in (InGa) (AsP). Laser thresholds of 5 kA/cm2 were obtained, while LED efficiences were on the order of 2%. Incoherent life test over 6000 hours showed no degradation.

Ladany, I.↗

Detection of gravitational radiation and oscillations of the sun via Doppler tracking of spacecraft

The magnitude of Doppler signals produced by gravitational wave burst, continuous gravitational waves, and oscillations of the sun interacting with a spacecraft are considered. Expressions are worked out for the appropriate noise entering each measurement. The noise sources considered are the Doppler extractor, fluctuations in the solar wind and the troposphere, and fluctuations in the reference oscillator.

Douglas, D. H.↗

Study of stratospheric-ionospheric coupling during thunderstorms and tornadoes

A continuous-wave-spectrum high-frequency Doppler sounder array with three transmitters at each of three sites was used to observe the dynamics of the coupling of energy between the stratosphere and the ionosphere. During times of severe weather activity wavelike disturbances have been detected on ground-based ionospheric sounding records as perturbations in electron densities. Infrasonic waves with wave periods of 3-7 min and with horizontal phase velocities of 600-800 m/s were observed when there was thunderstorm activity; gravity waves with wave periods of 10-15 min and horizontal phase velocities of 100-200 m/s were detected when there was tornado activity. Both triangulations from the cross correlation functions of the Doppler records based on an assumption of no background wind shear and ray-tracing computations including an assumed background wind shear indicate that the waves originated in the vicinity of the thunderstorms and tornadoes. A comparison of the wavelengths of the infrasonic and gravity waves observed at ionospheric heights and those in cloud-top pictures from satellites show that they are all of the order of 100-300 km.

Hung, R. J.↗

The response of heat-shield materials to intense laser radiation

Experimental results for the response of ATJ graphite, Carbitex 100, and carbon phenolic to intense continuous-wave laser radiation are presented. Both penetration and mass-loss test techniques are used and compared. The results are also compared with a simple ablation theory applicable to laser irradiation. Reasons for the disparity between experiment and theory, and applicability of the results to other heating situations, such as planetary entry, are discussed.

Lundell, J. H.↗

Optical and acoustical measuring techniques

The paper reviews the techniques of laser and acoustic Doppler measurement of fluid velocities in confined and free flows. The main mathematical relations are presented, and some systems are studied. Resolution properties of coaxial, bistatic, and pulsed CO2 laser Doppler velocimeter systems are compared. Schematics for pulsed and continuous wave acoustic Doppler systems are discussed. Both of these types of systems benefit from using a bistatic configuration instead of a coaxial system. The pulsed systems avoid contamination of source noise by not sampling until after the source noise has passed the receiver. Comparison of wind velocity measured with a pulsed acoustic Doppler and with a boundary layer profile is made.

Cliff, W. C.↗

Stabilization of He2(A(sup 3)Sigma(sub u)(+)) molecules in liquid helium by optical pumping for vacuum UV laser

A technique is disclosed for achieving large populations of metastable spin-aligned He2(a 3 Sigma u +) molecules in superfluid helium to obtain lasing in the vacuum ultraviolet wavelength regime around 0.0800 micron m by electronically exciting liquid (superfluid) helium with a comparatively low-current electron beam and spin aligning the metastable molecules by means of optical pumping with a modestly-powered (100mW) circularly-polarized continuous wave laser operating at, for example, 0.9096 or 0.4650 micron m. Once a high concentration of spin-aligned He2 (a 3 Sigma u +) is achieved with lifetimes of a few milliseconds, a strong microwave signal destroys the spin alignment and induces a quick collisional transition of He2 (a 3 Sigma u +) molecules to the a 1 Sigma u + state and thereby a lasing transition to the X 1 Sigma g + state.

Zmuidzinas, J. S.↗

The applicability of Brillouin scattering to flow field diagnostics

To fill the void between turbulence theory and experiment; particularly in the flow fields consisting of monatomic gases, for example in wind tunnels, means of measuring fluctuating quantities are needed. In the area of density fluctuation measurement, the optical method of Brillouin scattering was suggested. This was based on the theory, that the Brillouin scattered intensity is proportional to a function of density. In this investigation the potential of this method as a diagnostic tool was studied. Here the density fluctuations in gases were sought. Continuous wave lasers and interferometers were used as the primary illuminating source and scattered light filters respectively.

Laiosa, J.↗

Time-dependent local density measurements in unsteady flows

A laser-induced fluorescence technique for measuring the relative time-dependent density fluctuations in unsteady or turbulent flows is demonstrated. Using a 1.5-W continuous-wave Kr(+) laser, measurements have been obtained in 0.1-mm-diameter by 1-mm-long sampling volumes in a Mach 3 flow of N2 seeded with biacetyl vapor. A signal amplitude resolution of 2% was achieved for a detection frequency bandwidth of 10 kHz. The measurement uncertainty was found to be dominated by noise behaving as photon statistical noise. The practical limits of signal-to-noise ratios have been characterized for a wide range of detection frequency bandwidths that encompasses those of interest in supersonic turbulence measurements.

Mckenzie, R. L.↗