Search NASA⌕ Search

SEARCH · Search NASA

Results for “CRYOGENIC TEMPERATURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Simulations of the fault current limiting operation of a long-length REBCO CORC ® superconducting cable cooled by helium gas

Conductor-on-round-core (CORC®) cables composed of rare-earth-barium-copper-oxide high-temperature superconducting (HTS) tapes are of great interest for power transmission applications due to their many advantages such as high power density, light weight, and low loss. Closed circulation loops of cryogenic helium gas can be used to cool HTS cables down to low temperatures to significantly improve their current-carrying capacity. Coupled circuit-electromagnetic-thermal finite element simulations implemented in the COMSOL Multiphysics package were developed, validated, and then used for simulating the fault current limiting (FCL) performance and the cooling processes of an 8-layer CORC® cable cooled with a flow of cryogenic helium gas. In the simulations, the temperature dependence of the electrical and thermal properties of all component materials is implemented for improved accuracy. To overcome computational challenges caused by the considerable difference in geometrical scales (i.e. few-µm-thick HTS layers versus 10 m-long HTS cable), the model is divided into two separate simulations. The first simulation is performed on the transverse cross-section of the cable to calculate the electric field, heating power and temperature rise in each component of a CORC® cable during FCL operation. The heating power calculated in the first simulation is transferred to the second model to simulate the cooling of a 10 m-long cable after the fault is cleared. The effect of the helium gas flow rate on the cooling process is also investigated to develop strategic approaches for optimizing cooling systems for HTS cables with FCL capability. The simulations indicated that a 40 ms fault with a voltage drop of 20 V m −1 along the cable can result in a temperature increase from 60 K to about 165 K inside the cable, and it takes about 500 s to cool the cable back to nearly 60 K with a flow of cold helium gas at a rate of 5 g s −1 .

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of an energy-dependent instrument response function to analysis of nTOF data from cryogenic DT experiments

Neutron time-of-flight (nTOF) detectors are used to diagnose the conditions present in inertial confinement fusion (ICF) experiments and basic laboratory physics experiments performed on an ICF platform. The instrument response function (IRF) of these detectors is constructed by convolution of two components: an x-ray IRF and a neutron interaction response. The shape of the neutron interaction response varies with incident neutron energy, changing the shape of the total IRF. Analyses of nTOF data that span a broad range of energies must account for this energy-dependence in order to accurately infer plasma parameters and nuclear properties in ICF experiments. This work briefly reviews a matrix multiplication approach to convolution which allows for an energy-dependent change in the shape of the IRF. This method is applied to synthetic data resembling symmetric cryogenic DT implosions to examine the effect of the energy-dependent IRF on the inferred areal density. Here, results of forward fits that infer ion temperatures and areal densities from nTOF data collected during cryogenic DT experiments on OMEGA are also discussed.

47 OTHER INSTRUMENTATION↗

Control of microphonics for a superconducting radio-frequency photo-injector cryomodule

A superconducting radio-frequency photo-injector cryomodule is being developed for the high-energy upgrade of the Linac Coherent Light Source (LCLS-II-HE). This effort is a collaboration between the Facility for Rare Isotope Beams at Michigan State University (MSU), Argonne National Laboratory, Helmholtz-Zentrum Dresden-Rossendorf, and SLAC National Accelerator Laboratory. The cryomodule features a 185.7 MHz superconducting quarter-wave resonator (QWR) designed to operate with an RF electric field of 30 MV/m at the photo-cathode. Mechanical vibrations must be controlled for operation with stable amplitude and phase. The first prototype cryomodule was cold-tested at MSU with a QWR, fundamental power coupler, tuner, and cathode stalk. In the cold test, we observed microphonics that made it difficult to control the RF phase at high gradient. The cryogenic circuit was identified as a likely culprit. This paper presents our studies of microphonics during the cryomodule cold test and follow-up investigations at room temperature. Our findings provided valuable feedback for modifications to the cryogenic circuit and a successful second cold test of the cryomodule.

Accelerator Physics↗

Broad range material-to-system screening of metal–organic frameworks for hydrogen storage using machine learning

Hydrogen is pivotal in the transition to sustainable energy systems, playing major roles in power generation and industrial applications. Metal–organic frameworks (MOFs) have emerged as promising mediums for efficient hydrogen storage. However, identifying potential candidates for deployment is challenging due to the vast number of currently available synthesized MOFs. This study integrates molecular simulations, machine learning, and techno-economic analysis to evaluate the performance of MOFs across broad operation conditions for hydrogen storage applications. While previous screenings of MOF databases have predominantly emphasized high hydrogen capacities under cryogenic conditions, this study reveals that optimal temperatures and pressures for cost minimization depend on the raw price of the MOF. Specifically, when MOFs are priced at $15/kg, among the 9720 MOFs tested, 9692 MOFs achieve the lowest cost at temperatures between 170 K and 250 K and a pressure of 150 bar. Under these optimal conditions, 362 MOFs deliver a lower levelized cost of storage than 350 bar compressed gas hydrogen storage. Furthermore, this study reveals key material properties that result in low system cost, such as high surface areas (>3000 m2/g), large void fractions (>0.78), and large pore volumes (>1.1 cm3/g).

Hydrogen storage↗

Flash Freeze Flow Tube to Vitrify Aerosol Particles at Fixed Relative Humidity Values

Development of methods to measure the phase transitions and physical properties of submicron atmospheric aerosol particles is needed to better model these systems. Here, we introduce a method to flash freeze submicron particles to measure phase transitions as a function of relative humidity (RH). Particles are equilibrated at a fixed RH, vitrified in a temperature-controlled flow tube, and imaged with cryogenic transmission electron microscopy (cryo-TEM). We demonstrate the use of the technique for measuring the efflorescence relative humidity (ERH) of potassium sulfate and potassium chloride aerosol as well as the separation RH for a multicomponent organic/inorganic system that undergoes liquid-liquid phase separation (LLPS). The location of phase transitions can shift between the micrometer and nanometer size regimes and particles in a given population may have a range of RH over which a phase transition occurs. This technique addresses these requirements by allowing for characterization of the phase transitions for individual particles in a population on the submicron scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scanning SQUID microscopy in a cryogen-free dilution refrigerator

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing chamber plate to optimize thermal anchoring of the sample. The microscope housing fits into the bore of a superconducting vector magnet, and our design accommodates a large number of wires connecting the sample and sensor. Through a combination of vibration isolation in the cryostat and a rigid microscope housing, we achieve relative vibrations between the SQUID and the sample that allow us to image with micrometer resolution over a 150 μm range while the sample stage temperature remains at base temperature. To demonstrate the capabilities of our system, we show images acquired simultaneously of the static magnetic field, magnetic susceptibility, and magnetic fields produced by a current above a superconducting micrometer-scale device.

47 OTHER INSTRUMENTATION↗

Field-Deployable Quantum Memory for Quantum Networking

High-performance quantum memories are an essential component for regulating temporal events in quantum networks. As a component in quantum-repeaters, they have the potential to support the distribution of entanglement beyond the physical limitations of fiber loss. This will enable key applications such as quantum key distribution, network-enhanced quantum sensing, and distributed quantum computing. Here, we present a quantum memory engineered to meet real-world deployment and scaling challenges. The memory technology utilizes a warm rubidium vapor as the storage medium, and operates at room temperature, without the need for vacuum- and/or cryogenic- support. Here, we demonstrate performance specifications of high-fidelity retrieval (95%) and low operation error (10 –2 ) at a storage time of 160 µs for single-photon level quantum memory operations. We further show a substantially improved storage time (with classical-level light) of up to 1ms by suppressing atomic diffusions. The device is housed in an enclosure with a standard 2U rackmount form factor, and can robustly operate on a day scale in a noisy environment. This result marks an important step toward implementing quantum networks in the field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Constraints on lepton number violation with the 2 tonne · year CUORE dataset

Matter-antimatter asymmetry underlines the incompleteness of the current understanding of particle physics. Neutrinoless double-beta decay (0νββ) may help explain this asymmetry while unveiling the Majorana nature of the neutrino. The CUORE (Cryogenic Underground Observatory for Rare Events) experiment searches for 0νββ of 130 Te using a tonne-scale cryogenic calorimeter operated at milli-kelvin temperatures. We report no evidence of 0νββ and place a lower limit on the half-life of T 1/2 > 3.5 × 10 25 years (90% credibility interval) with over 2 tonne·years of TeO 2 exposure. Finally, the tools and techniques developed for this result and the 5-year stable operation of nearly 1000 detectors demonstrate crucial infrastructure for future-generation experiments capable of searching for 0νββ across multiple isotopes.

Adams, D. Q. [Department of Physics and Astronomy,↗

Predictive modeling of Néel temperature in austenitic alloys using CALPHAD and data analytics

The Néel temperature is a crucial yet often overlooked parameter in calculating the stacking fault energy (SFE) of austenitic alloys. Several empirical equations have been proposed to estimate the Néel temperature of austenitic alloys, which are then used to calculate the SFE and explain deformation mechanisms. However, these empirical equations, typically derived using linear regression algorithms, are often simplistic and may fail to capture the complex interactions among multiple alloying elements that influence the Néel temperature. Moreover, their applicability is usually limited to specific compositional ranges. In this study, we propose a CALPHAD based approach and develop a surrogate decision tree based regression model capable of capturing the interactions among multiple alloying elements to predict the Néel temperature. Predictions from both the CALPHAD approach and the regression model show close agreement with experimental measurements reported in the literature. In conclusion, the implications of accurate Néel temperature predictions on the calculated SFE and deformation mechanisms are also discussed.

36 MATERIALS SCIENCE↗

A novel active veto prototype detector with an inner target for improved rare event searches

Here, we report the fabrication and performance of an annular, cryogenic, phonon-mediated veto detector that can host an inner target detector, allowing substantial reduction in radiogenic backgrounds for rare event search experiments. A germanium veto detector of mass ~500g with an outer diameter of 76 mm and an inner diameter of 28 mm was produced inside of which was mounted a 25 mm diameter germanium inner target detector of mass ~10g. The detector was designed using inputs from a GEANT4 based simulation, where it was modeled to be sandwiched between two germanium detectors. The simulation showed that the background rates (dominated by gamma interactions) could be reduced by >90%, and that such an arrangement is sufficient for aggressive background reduction needed for neutrino and dark matter search experiments. Operating at mK temperatures at the experimental site, the veto detector prototype achieved a baseline resolution of 1.24±0.02 keV while hosting a functional inner target detector. The baseline resolution of the inner target detector was 147±2 eV. The experimental results of an identical detector arrangement are in excellent agreement with the simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Portable Miniature Cryogenic Environment for In Situ Neutron Diffraction

Neutron diffraction instruments offer a platform for materials science and engineering studies at extended temperature ranges far from ambient. As one of the widely used neutron sample environment types, cryogenic furnaces are usually bulky and complex, and they may need hours of beamtime overhead for installation, configuration, cooling, and sample change, etc. To reduce the overhead time and expedite experiments at the state-of-the-art high-flux neutron source, we developed a low-cost, miniature, and easy-to-use cryogenic environment (77–473 K) for in situ neutron diffraction. A travel-size mug serves for the environment where the samples sit inside. Immediate cooling and an isothermal dwell at 77 K are realized on the sample by direct contact with liquid N 2 in the mug. The designed Al inserts serve as the holder of samples and heating elements, alleviate the thermal gradient, and clear neutron pathways. Both a single-sample continuous measurement and multi-sample high-throughput measurements are demonstrated in this environment. High-quality and refinable in situ neutron diffraction patterns are acquired on model materials. The results quantify the orthorhombic-to-cubic phase transformation process in LiMn 2 O 4 and differentiate the anisotropic lattice thermal expansions and bond length evolutions between rhombohedral perovskite oxides with composition variation.

47 OTHER INSTRUMENTATION↗

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 2 – Transient modeling and pump-down path selection

Low-pressure conditions required for operation of helium cryogenic systems below the normal boiling point (i.e. 4.2 K) are established through a transient process, commonly referred to as ‘pump-down’. This process is defined as the transition from pressures above atmospheric conditions to the saturation pressure which corresponds to a specified operational temperature. The FRIB 2 K system consists of five cryogenic centrifugal compressors which are operated in series. Historically, the pump-down process path has been established through empirical methods and system operator experience. Investigation into the pump-down process at FRIB aimed to develop a pump-down methodology which relies on theoretical model predictions rather than empirically developed process paths. Ensuring stable operation during the pump-down process involved application of a centrifugal compressor performance prediction model, which is described in Part 1 of this paper. Compressor performance maps can be directly used to evaluate the stability of a selected pump-down path and anticipate the overall reliability of the selected path. In conjunction with the compressor performance maps, a system pressure model was developed to estimate the transient pressure response during the pump-down process. Lastly, an explicit equation was developed to establish a mass flow rate profile for the pump-down process. Implementation of the presented methodology (including the developed models) allows for the system operator to determine a continuous pump-down path which maintains compressor stability while conforming to overall system capabilities. Altogether, the methodology presented has resulted in simplification of transient pump-down operations and increased the reliability, stability and efficiency of the pump-down process.

Compressor train control↗

Radiation damage and dose limits in serial synchrotron crystallography at cryo- and room temperatures

Radiation damage limits the accuracy of macromolecular structures in X-ray crystallography. Cryogenic (cryo-) cooling reduces the global radiation damage rate and, therefore, became the method of choice over the past decades. The recent advent of serial crystallography, which spreads the absorbed energy over many crystals, thereby reducing damage, has rendered room temperature (RT) data collection more practical and also extendable to microcrystals, both enabling and requiring the study of specific and global radiation damage at RT. Here, we performed sequential serial raster-scanning crystallography using a microfocused synchrotron beam that allowed for the collection of two series of 40 and 90 full datasets at 2- and 1.9-Å resolution at a dose rate of 40.3 MGy/s on hen egg white lysozyme (HEWL) crystals at RT and cryotemperature, respectively. The diffraction intensity halved its initial value at average doses ( D 1/2 ) of 0.57 and 15.3 MGy at RT and 100 K, respectively. Specific radiation damage at RT was observed at disulfide bonds but not at acidic residues, increasing and then apparently reversing, a peculiar behavior that can be modeled by accounting for differential diffraction intensity decay due to the nonuniform illumination by the X-ray beam. Specific damage to disulfide bonds is evident early on at RT and proceeds at a fivefold higher rate than global damage. The decay modeling suggests it is advisable not to exceed a dose of 0.38 MGy per dataset in static and time-resolved synchrotron crystallography experiments at RT. This rough yardstick might change for proteins other than HEWL and at resolutions other than 2 Å.

36 MATERIALS SCIENCE↗

An in-situ movable calibration source for cryogenic particle detectors

A prototype device capable of moving a radioactive calibration source to multiple positions was operated at millikelvin temperatures using a modified commercial stepper motor. It was developed as an in-situ calibration strategy for cryogenic dark matter detectors. Data taken by scanning a calibration source across multiple radial positions of a prototype dark matter detector demonstrated its functionality. Construction, heat load, and operation of the device are discussed, as is the effect of the motor on the detector operation. A sample dataset taken over multiple positions of a SuperCDMS detector is presented as an example of the utility of such a device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The phase-2 particle x-ray temporal diagnostic for simultaneous measurement of multiple x-ray and nuclear emission histories from OMEGA implosions (invited)

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as T e is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (~15 ps) scintillator-channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons (DTn) from OMEGA Cryo-DT implosions. High quality data have been collected from warm implosions at OMEGA. These data have been used to infer spatially integrated T e (t) with <10% uncertainty at peak emission. Nuclear and x-ray emission histories are measured with 10 ps relative timing uncertainty for x rays and DTn and 12 ps for x rays and deuterium- 3 He protons (D 3 Hep). A future upgrade to the system will enable spatially integrated T e (t) with 40 ps time-resolution from cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of the enthalpy of adsorption of hydrogen in activated carbon at room temperature

The development of high-performance materials for hydrogen storage by adsorption requires detailed understanding of the adsorbate-adsorbent interactions, e.g., the enthalpy of adsorption ΔH, which measures the interaction strength. The determination of ΔH for a weakly adsorbing gas such as hydrogen in a carbonaceous porous material is difficult experimentally, normally requiring measuring two cryogenic adsorption isotherms. Here we demonstrate a calculation of ΔH based on ca. room temperature adsorption isotherms at 273 K and 296 K using the Clausius-Clapeyron equation. This requires an estimation of the volume of the adsorbed film (~40%, ~12% of the total pore volume at 77 K, 296 K, respectively) obtained from fits of the excess adsorption isotherms to an Ono-Kondo model with the auxiliary use of a fixed point corresponding to the saturation film density (estimated as 100 ± 20 g/L) which appears to be remarkably sample and temperature independent, i.e., a property of the adsorbate. The calculated room temperature enthalpy of adsorption ΔH = 8.3 ± 0.4 kJ/mol is in excellent agreement with the low-coverage cryogenic determination of ΔH. The methodology hereby proposed facilitates reliable calculations of the enthalpy of adsorption at room temperatures for weakly-adsorbing gases.

08 HYDROGEN↗

Life cycle energy use and greenhouse gas emissions of ammonia production from renewable resources and industrial by-products

Conventionally, ammonia is produced from natural gas via steam methane reforming (SMR), water-gas shift reaction, and the Haber–Bosch process. The process uses fossil natural gas, which leads to 2.6 metric tons of life cycle greenhouse gas (GHG) emissions per metric ton of ammonia produced. With ammonia being the second most produced chemical in the world, its production accounts for approximately 2% of worldwide fossil energy use and generates over 420 million tons of CO 2 annually. To reduce its carbon intensity, ammonia synthesis relying on renewable energy or utilizing by-products from industrial processes is of interest. In this work, we conduct a life cycle analysis of conventional and alternative ammonia production pathways by tracking energy use and emissions in all conversion stages, from the primary material and energy resources to the ammonia plant gates. Of all the alternative pathways, obtaining N 2 from cryogenic distillation and H 2 from low-temperature electrolysis using renewable electricity has the lowest cradle-to-plant-gate GHG emissions, representing a 91% decrease from the conventional SMR pathway.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A cryogenic continuously rotating half-wave plate mechanism for the POLARBEAR-2b cosmic microwave background receiver

In this report we present the design and laboratory evaluation of a cryogenic continuously rotating half-wave plate (CHWP) for the POLARBEAR-2b (PB-2b) cosmic microwave background receiver, the second installment of the Simons Array. PB-2b will observe at 5200 m elevation in the Atacama Desert of Chile in two frequency bands centered at 90 GHz and 150 GHz. In order to suppress atmospheric 1/f noise and mitigate systematic effects that arise when differencing orthogonal detectors, PB-2b modulates linear sky polarization using a CHWP rotating at 2 Hz. The CHWP has a 440 mm clear aperture diameter and is cooled to ≈50 K in the PB-2b receiver cryostat. It consists of a low-friction superconducting magnetic bearing and a low-torque synchronous electromagnetic motor, which together dissipate < 2 W. During cooldown, a grip-and-release mechanism centers the rotor to < 0.5 mm, and during continuous rotation, an incremental optical encoder measures the rotor angle with a noise level of 0.1 μrad/Hz. We discuss the experimental requirements for the PB-2b CHWP, the designs of its various subsystems, and the results of its evaluation in the laboratory. The presented CHWP has been deployed to Chile and is expected to see first light on PB-2b in 2020 or 2021.

47 OTHER INSTRUMENTATION↗