Comparison of Spectral Radiance Calibration Techniques Used for Backscatter Ultraviolet Satellite Instruments

Methods for determining the absolute radiometric calibration sensitivities of backscatter ultraviolet (BUV) satellite instruments are compared as part of an effort to minimize pre-launch calibration errors. An internally illuminated integrating sphere source has been used for the Shuttle Solar BUV (SSBUV), Total Ozone Mapping Spectrometer (TOMS), Ozone Mapping Instrument (OMI), and Global Ozone Monitoring Experiment 2 (GOME-2) using standardized procedures traceable to national standards. These sphere-based sensitivities agree to within three percent [k equals 2] relative to calibrations performed using an external diffuser illuminated by standard irradiance sources, the customary radiance calibration method for BUV instruments. The uncertainty for these calibration techniques as implemented at the NASA Goddard Space Flight Centers Radiometric Calibration and Development Laboratory is shown to be 4 percent at 250nm [k equals 2] when using a single traceable calibration standard. Significant reduction in the uncertainty of nearly 1 percent is demonstrated when multiple calibration standards are used.

residual errors↗

Detection of Unexpected High Correlations between Balance Calibration Loads and Load Residuals

An algorithm was developed for the assessment of strain-gage balance calibration data that makes it possible to systematically investigate potential sources of unexpected high correlations between calibration load residuals and applied calibration loads. The algorithm investigates correlations on a load series by load series basis. The linear correlation coefficient is used to quantify the correlations. It is computed for all possible pairs of calibration load residuals and applied calibration loads that can be constructed for the given balance calibration data set. An unexpected high correlation between a load residual and a load is detected if three conditions are met: (i) the absolute value of the correlation coefficient of a residual/load pair exceeds 0.95; (ii) the maximum of the absolute values of the residuals of a load series exceeds 0.25 % of the load capacity; (iii) the load component of the load series is intentionally applied. Data from a baseline calibration of a six-component force balance is used to illustrate the application of the detection algorithm to a real-world data set. This analysis also showed that the detection algorithm can identify load alignment errors as long as repeat load series are contained in the balance calibration data set that do not suffer from load alignment problems.

strain-gage balance↗

Evaluation of Long-Term Calibrations of the AVHRR Visible Radiances

Two systematic calibrations have been compiled for the visible radiances measured by the series of AVHRR instruments flown on the NOAA operational polar weather satellites: one by the International Satellite Cloud Climatology Project (ISCCP), anchored on NASA ER-2 underflights in the 1980s and early 1990s and covering the period 1981-2009, and one by the PATMOS-x project, anchored on comparisons to the MODIS instruments on the Aqua and Terra satellites in the 2000s and covering the period 1979-2010 (this result also includes calibration for the near-IR channels). Both methods have had to extend their anchor calibrations over a long series of instruments using different vicarious approaches, so a comparison provides an opportunity to evaluate how well this extension works by cross-checking the results at the anchor points. The basic result of this comparison is that for the ''afternoon'' series of AVHRRs, the calibrations agree to within their mutual uncertainties. However, this retrospective evaluation also shows that the representation of the time variations can be simplified. The ISCCP procedure had much more difficulty extending the calibration to the ''morning'' series of AVHRRs with the calibrations for NOAA-15 and NOAA-17 exceeding the estimated uncertainties. Given the general agreement, a new calibration for all AVHRR visible radiances (except TIROS-N, NOAA-6, NOAA-19, and MetOp-A) is proposed that is based on the average of the best linear fits to the two time records. The estimated uncertainty of these calibrations is 63% absolute (scaled radiance units).

Advanced Very High Resolution Radiometer↗

Application of quasi-deep convective clouds method for MODIS and VIIRS TEB calibration assessments

A technique to use deep convective clouds (DCC) and quasi-DCC (qDCC) for the calibration assessment of the thermal emissive bands (TEB) on remote sensing instruments has proven feasible. The Terra and Aqua MODIS and S-NPP and NOAA-20 VIIRS TEB calibration uses a nonlinear algorithm whose nonlinear coefficients rely on on-orbit black body (BB) warm-up and cool-down (WUCD) activities for updates. However, the limited BB temperature range affects the calibration’s uncertainty. The DCC core, one of the coldest Earth scenes, is suitable for MODIS calibration assessments; more specifically, for the evaluation of the offset effect in its TEB quadratic calibration function. Moreover, nighttime qDCC measurements provide the advantage of removing solar reflectance effects, thus enhancing the assessment’s accuracy for the midwave infrared TEB. In this paper, the qDCC method is applied to the Terra MODIS and VIIRS TEB. Their stabilities are assessed using long-term DCC and qDCC trending measurements over the instruments’ entire missions. The measurements from bands with an approximately 11-μm wavelength are used to identify the DCC pixels. MODIS band31 (~ 11m) has demonstrated stable performance and accurate calibration for both instruments throughout their respective missions. MODIS band31 can therefore be used as a reference for the other TEB. Furthermore, it also allows for a Terra and Aqua MODIS TEB cross-comparison. The assessment results, along with the calibration uncertainty and Level 1B product impact modeling, can be quite helpful for calibration improvements.

MODIS↗

MODIS TEB Calibration Algorithm Improvements for Future L1B Collection

Terra and Aqua MODIS have provided continuous global observations for scientific applications for more than 20 and 18 years, respectively. The radiometric calibration of the MODIS thermal emissive bands (TEB) is based on a quadratic approximation of the instrument response. The calibration coefficients look-up tables (LUTs) are updated using the response of the MODIS on-board blackbody (BB)with the response background subtracted by space view. The quarterly on-board BB warm-up and cool-down activity temperature ranges from 270 K to 315 K, and the derived offset has a relatively large uncertainty. Electronic cross-talk, an artifact that affects both instrument calibration and Earth view (EV) radiance retrievals, is corrected based on lunar observations. Calibration assessments using EV observations (e.g. ocean, desert, Antarctic Dome Concordia, and deep convective clouds) provide useful information to evaluate the impact of the Terra safe mode (February 2016) and Aqua MODIS formatter reset (January 2018) events on both MODIS instruments. This study focuses on the TEB radiometric calibration algorithm improvements for future collections based on calibration assessments using EV measurements and analytical modeling. Measurement stability and consistency over specific Earth scenes with a wide temperature range, as well as their brightness temperature (BT) dependency, are used for bias estimations in the calibration coefficients. Calibration coefficients are derived and updated after adjusting the current fitting algorithm. Thereafter, using the test LUTs, their impact on the Level 1B (L1B) data for different EV scenes is analyzed.

MODIS↗

Overview of GSICS visible calibration methods.

Global Space-based Inter-Calibration System (GSICS) is an international collaborative effort initiated in 2005 by the World Meteorological Organization (WMO) and the Coordination Group for Meteorological Satellites (CGMS) to 1-monitor, 2-improve and 3-harmonize the quality of observations from operational weather and environmental satellites of the Global Observing System (GOS). GSICS aims at ensuring consistent accuracy among space-based observations worldwide for climate monitoring, weather forecasting, and environmental applications by 1-monitoring instrument performance, 2-operational inter-calibration of satellite instruments, 3-radiometrically scaling observations to absolute reference standards, 4-recalibration of archived datasets. Although many of the GSIC visible inter-calibration methods are based on medium pixel-level imagers such as MODIS, VIIRS, AVHRR, and geostationary sensors, the methods are applicable to high spatial resolution imagery such as Landsat. For sensor inter-calibration efforts, coincident ray-matched reflectance pairs are used to transfer the calibration from the reference to the target instrument. Spectral band adjustment factors (SBAF) are applied to account for any spectral band differences. For sensor stability monitoring, PICS, deep convective cloud (DCC) and polar ice Earth viewed targets are utilized. GSICS uses the moon for stability monitoring by using the GSICS Implementation of the USGS Robotic Lunar Observatory (ROLO) model (GIRO). GSICS is looking forward to the launch of CLARREO on the international space station (ISS) in 2023. The CLARREO hyperspectral reflective solar band (RSB) sensor will establish an absolute calibration reference in space, which will characterize invariant targets and will inter-calibrate concurrent sensors. Examples of these calibration methods will be presented at the workshop.

Visible calibration methods↗

Application of Quasi-Deep Convective Clouds Method for VIIRS and MODIS TEB Calibration Assessments

A technique that utilizes quasi-deep convective clouds (qDCC) for the calibration assessment of the thermal emissive bands (TEB) on remote sensing instruments has been proven viable. The Terra and Aqua MODIS and S-NPP and NOAA-20 VIIRS TEB calibration uses a nonlinear algorithm whose nonlinear coefficients rely on on-orbit blackbody (BB) warm-up and cooldown operations for updates. However, a limited BB temperature range affects the calibration’s accuracy particularly for cold scenes. The deep convective clouds (DCC) core, one of the coldest Earth scenes, is suitable for MODIS calibration assessments; more specifically, for the evaluation of the offset term’s effect in its TEB quadratic calibration function. Moreover, nighttime qDCC measurements provide with the advantage of removing solar reflectance effects during daytime, thus enhancing the assessment’s accuracy for the midwave infrared TEB. In this paper, this qDCC method is applied to the Terra MODIS and VIIRS TEB; and their stabilities are assessed using long-term qDCC trending measurements over the instruments’ missions. The measurements from bands with an 11-μm wavelength are used to identify the DCC pixels. The 11-μm bands, MODIS band 31 and VIIRS bands M15 and I5, are stable throughout the MODIS and VIIRS missions and have shown excellent calibration accuracy and noise performance. Hence, using these bands as references, a normalization method is employed to enhance the accuracy of the stability and consistency assessments. The S-NPP VIIRS TEB show stable trends over the instrument’s mission. The S-NPP-to-N20 VIIRS comparison shows their TEB measurements are consistent over qDCC. The Terra MODIS TEB also show stable performance – except for bands 27, 29, and 30. Terra MODIS band 30 shows a large downward trend throughout the mission, while bands 27 and 29 show slight, upward drifts. Lastly, a calibration correction using qDCC assessments is discussed and intended to be used in a future calibration algorithm collection.

MODIS↗

Impact of Satellite Orbit Drift on Modis Earth Scene Observations Used in Calibration of the Reflective Solar Bands

After more than 20 years in orbit, NASA’s Terra and Aqua satellites have both started drifting away from their historically maintained orbits. The MODIS instruments on Terra and Aqua continue to collect valuable Earth observation data, but the changing orbits present a challenge for maintaining accurate calibration. The MODIS reflective solar bands (RSB), spanning the wavelength range from 412 nm to 2130 nm, are calibrated on orbit using a combination of regular data collections from an on-board solar diffuser, the Moon, and pseudo-invariant Earth scenes. Starting in the Collection 6 Level 1B (L1B) data products, the RSB calibration began using data from desert targets for a few of the visible bands to better track changes in the response versus scan angle that could not be captured by the on-board calibration. The use of Earth scene data has been extended recently for Terra MODIS calibration in Collection 6.1 (C6.1) and the upcoming Collection 7 (C7) L1B to also include data from ocean scenes and deep convective clouds (DCC). Drifts in both the orbit inclination and ground track of Terra and Aqua lead to changes in the solar illumination angles and satellite view angles of the Earth scenes. We discuss how these orbital changes impact the desert and DCC targets used for MODIS RSB calibration and present the accompanying changes made to our C6.1 and C7 calibration algorithms. We also discuss remaining future challenges, such as better characterization of bi-directional reflectance distribution functions, and possible alternative calibration strategies.

MODIS↗

Improvements of the Load Schedule for the Machine Calibration of a Strain-Gage Balance

The load schedule for the calibration of a six-component force balance in a calibration machine was improved. Now, single-component loads are repeated in regular intervals during the calibration. This approach has several advantages. First, the number of single-component loads increases to about twenty-two percent of all loads and load combinations. Consequently, more accurate numerical estimates of the primary bridge sensitivities can be obtained if global regression is used for the analysis of the calibration data. In addition, single-component repeats make it possible to track the stability of the applied loads during the calibration process. Finally, interactions of single-component repeats can be compared with interactions that are observed during the application of manual loads to the balance. Machine calibration and manual data sets of two force balances are used to illustrate benefits of the new load schedule. It is shown in the examples how differences between the observed interactions of machine calibration and manual data can be quantified. The suggested improvements can also be implemented in the load schedule for the machine calibration of a moment or direct-read balance as long as single-component loads are included that are described in the design load format of the balance.

wind tunnel test↗

Initial On-Orbit Spectral Calibration of the PACE Ocean Color Instrument

The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission Project Science Team has used Ocean Color Instrument (OCI) measurements of Fraunhofer lines in spectra of sunlight reflected by the solar diffuser and measurements of atmospheric absorption bands in cloudtop and ocean spectra to characterize the spectral calibration of OCI on orbit. Multiple lines have been analyzed for both the ultraviolet to visible (UVVIS, 340−607 nm) and visible to near-infrared (VISNIR, 597−897 nm) grating spectrographs. The spectrographs yield hyperspectral observations with 5 nm bandwidths and 0.625 nm sampling intervals. The on-orbit observations have been compared with the prelaunch spectral calibration of OCI performed by the Goddard Laser for Absolute Measurement of Radiance (GLAMR) during thermal vacuum testing to track any changes in the calibration since launch. The calibration analyzed the line positions and strengths for the Fraunhofer lines for each spectrograph by comparing the solar spectra measured by OCI with predicted solar spectra derived from the solar reference spectrum and the BRDF of the solar diffuser, convolved with the OCI relative spectral responses. The calibration also compared the line positions of the atmospheric absorption bands with the model transmissions used by the PACE Project. The line position comparisons show that the root mean square (RMS) spectral difference between the measured and predicted spectra is 0.15 nm, the average spectral shift is 0.062 nm, and the residual spectral dispersion over the wavelength range of the Fraunhofer lines is 0.17 nm. All three estimates of the spectral accuracy of OCI meet the instrument functional requirement of a spectral accuracy of 0.5 nm and are well within the 0.625 nm sampling interval of the data. The line strength comparisons between measured and predicted spectra are essentially the same. These results show that the spectral calibration of OCI on orbit has not drifted since the prelaunch calibration of OCI by GLAMR and that the on-orbit spectral calibration of OCI is stable over time. These results also provide a baseline for monitoring the future spectral performance of OCI on orbit.

Radiometric Calibration↗

A Method to Test Model Calibration Techniques: Preprint

This paper describes a method for testing model calibration techniques. Calibration is commonly used in conjunction with energy retrofit audit models. An audit is conducted to gather information about the building needed to assemble an input file for a building energy modeling tool. A calibration technique is used to reconcile model predictions with utility data, and then the 'calibrated model' is used to predict energy savings from a variety of retrofit measures and combinations thereof. Current standards and guidelines such as BPI-2400 and ASHRAE-14 set criteria for 'goodness of fit' and assume that if the criteria are met, then the calibration technique is acceptable. While it is logical to use the actual performance data of the building to tune the model, it is not certain that a good fit will result in a model that better predicts post-retrofit energy savings. Therefore, the basic idea here is that the simulation program (intended for use with the calibration technique) is used to generate surrogate utility bill data and retrofit energy savings data against which the calibration technique can be tested. This provides three figures of merit for testing a calibration technique, 1) accuracy of the post-retrofit energy savings prediction, 2) closure on the 'true' input parameter values, and 3) goodness of fit to the utility bill data. The paper will also discuss the pros and cons of using this synthetic surrogate data approach versus trying to use real data sets of actual buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Method to Test Model Calibration Techniques

This paper describes a method for testing model calibration techniques. Calibration is commonly used in conjunction with energy retrofit audit models. An audit is conducted to gather information about the building needed to assemble an input file for a building energy modeling tool. A calibration technique is used to reconcile model predictions with utility data, and then the 'calibrated model' is used to predict energy savings from a variety of retrofit measures and combinations thereof. Current standards and guidelines such as BPI-2400 and ASHRAE-14 set criteria for 'goodness of fit' and assume that if the criteria are met, then the calibration technique is acceptable. While it is logical to use the actual performance data of the building to tune the model, it is not certain that a good fit will result in a model that better predicts post-retrofit energy savings. Therefore, the basic idea here is that the simulation program (intended for use with the calibration technique) is used to generate surrogate utility bill data and retrofit energy savings data against which the calibration technique can be tested. This provides three figures of merit for testing a calibration technique, 1) accuracy of the post-retrofit energy savings prediction, 2) closure on the 'true' input parameter values, and 3) goodness of fit to the utility bill data. The paper will also discuss the pros and cons of using this synthetic surrogate data approach versus trying to use real data sets of actual buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model-based approaches to calibration and certification of nondestructive assay systems - 15615

Increasingly, model-based methods founded in physics are employed to calibrate, or extend the calibration of, nondestructive assay (NDA) systems used to characterize materials contaminated with plutonium, uranium, and other radioactive isotopes. In addition, modeling and mathematical methods are used to establish system parameters, correction factors, and measurement uncertainty components in NDA measurements. The methods combine the characteristics of the measurement configuration (detector structure, object shape and dimensions, source-detector distance and orientation, and collimation), generator knowledge of the waste composition, and known physical properties of the system in order to establish these parameters, factors, and components. These methods offer several important benefits over traditional methods used to test, calibrate, operate, and certify radiation measurement systems. First, instruments can be set up and put into service more quickly and correctly using a model-based approach. Second, calibrations can be performed, tested, and modified with reduced use of plutonium and uranium standards when modeling and mathematical methods are employed. Also, modeled approaches avoid calibration error resulting from heterogeneous source distribution. Moreover, the parameters can be installed quickly and simply in an office setting without the need for the safety, security, and safeguards considerations that are present when standards are used. Calibrations can also be tailored to fit unique or nonstandard container configurations (for example, over-packed drums), new container types, or specialized matrices. Finally, when modeling methods are applied, correction factors and measurement uncertainty elements can be developed, tested, and validated relatively quickly and without the need for surrogate matrix materials and a large number of test measurements. A combined gamma and neutron NDA system has recently been moved from Idaho National Laboratory to the TA 55 facility at Los Alamos National Laboratory (LANL). The system will be used to assay transuranic waste packaged in drums. After the move, the system was modified to replace degraded components and improve system performance. Afterwards, it was set up to assay different container types and to extend the calibration range. Model-based approaches were used to adapt the system to its new purpose at LANL. This report will describe the setup, calibration, and certification of the combined system at LANL Included in this discussion will be the measurement applications and details of the measurement methods. The steps in these processes that involved the use of modeling and mathematical calculations to replace or supplement more traditional methods will be identified and discussed. Finally, an overarching discussion of the methods and advantages of model-based methods to establish the properties of NDA systems will be presented. We conclude that validated mathematical methods offer a robust, flexible, and mature approach which is technically defensible from first principle physics. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low Level Calibration of Liquid Scintillation Counting

Liquid Scintillation Counting (LSC) is an analytical laboratory method that quantifies the concentrations of alpha and beta emitting isotopes. The LSC method can be utilized for the detection of tritium, both environmentally and at nuclear facilities. Most LSC samples are aqueous-based and prepared as a radioactive sample dissolved or suspended in a high efficiency scintillation cocktail that converts radioactive energy into light pulses. When placed in counting vials, the liquid scintillation cocktail allows for optical coupling in which energy is released from the samples radioactive decay, and transferred to the scintillator. That energy is then absorbed to produce excited electrons that fall back to their ground-state and emit a pulse of light that is detected by the liquid scintillation analyzers photomultiplier tubes. Quench is a signal attenuation due to physical, chemical, or color interferences. To compensate for quench, quench standards of a known concentration are implemented at increasing increments of quench per vial to create a quench curve. Quench standards can be purchased pre-made or customized from the manufacturer, however, there are several issues that arise from purchasing the pre-made quench standards. The main issues with ordering pre-made quench standards is that they use higher count values, between 30,000 and 250,000 disintegrations per minute (dpm) of tritium per vial and only come in glass vials. Using higher counting standards in glass vials makes it hard to see lower concentrations in plastic vials. Additionally, when using higher energy standards the accuracy of the calibration readings tend to be lower. On the other hand, making a set of quench standards in-house allows for the customization of the dpm concentration to roughly 1,500-3,000 and preparation in plastic vials. This allows for lower activity readings that results in closer precision of the samples' true concentration. Technical Objectives: Create a quench curve and calibrate the LSA for tritium. Verify the calibration of the quench curve prior to cross sample runs. Check calibration against Quality Control (QC) reference value. Conclusion: a tritium quench curve calibration was performed using a scintillation cocktail with ultima gold (AB and AB/F), acetone (only with AB), and water (only with AB/F). By performing the tritium quench curve calibration, the counting efficiency was correlated to various levels of quench. Calibration checks with quality control standards were also performed to verify that the calibration was correct. The observed results provided acceptable values that matched the quality control standard reference values with an acceptable uncertainty. The next step will be fine tuning and cross comparison checks with legacy instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration, measurement, and characterization of soil moisture dynamics in a central Amazonian tropical forest

Soil moisture plays a key role in hydrological, biogeochemical, and energy budgets of terrestrial ecosystems. Accurate soil moisture measurements in remote ecosystems such as the Amazon are difficult and limited because of logistical constraints. Time domain reflectometry (TDR) sensors are widely used to monitor soil moisture and require calibration to convert the TDR's dielectric permittivity measurement (K a ) to volumetric water content (θ v ). In this study, our objectives were to develop a field-based calibration of TDR sensors in an old-growth upland forest in the central Amazon, to evaluate the performance of the calibration, and then to apply the calibration to determine the dynamics of soil moisture content within a 14.2 -m-deep vertical soil profile. Depth-specific TDR calibration using local soils in a controlled laboratory setting yielded a novel K a –θ v third-degree polynomial calibration. The sensors were later installed to their specific calibration depth in a 14.2-m pit. The widely used K a –θ v relationship (Topp model) underestimated the site-specific θ v by 22–42%, indicating significant error in the model when applied to these well-structured, clay-rich tropical forest soils. The calibrated wet- and dry-season θ v data showed a variety of depth and temporal variations highlighting the importance of soil textural differentiation, root uptake depths, as well as event to seasonal precipitation effects. Data such as these are greatly needed for improving our understanding of ecohydrological processes within tropical forests and for improving models of these systems in the face of changing environmental conditions.

54 ENVIRONMENTAL SCIENCES↗

Planck 2013 results. V. LFI calibration

We discuss the methods employed to photometrically calibrate the data acquired by the Low Frequency Instrument on Planck. Our calibration is based on a combination of the orbital dipole plus the solar dipole, caused respectively by the motion of the Planck spacecraft with respect to the Sun and by motion of the solar system with respect to the cosmic microwave background (CMB) rest frame. The latter provides a signal of a few mK with the same spectrum as the CMB anisotropies and is visible throughout the mission. In this data releasewe rely on the characterization of the solar dipole as measured by WMAP. We also present preliminary results (at 44 GHz only) on the study of the Orbital Dipole, which agree with the WMAP value of the solar system speed within our uncertainties. We compute the calibration constant for each radiometer roughly once per hour, in order to keep track of changes in the detectors’ gain. Since non-idealities in the optical response of the beams proved to be important, we implemented a fast convolution algorithm which considers the full beam response in estimating the signal generated by the dipole. Moreover, in order to further reduce the impact of residual systematics due to sidelobes, we estimated time variations in the calibration constant of the 30 GHz radiometers (the ones with the largest sidelobes) using the signal of an internal reference load at 4 K instead of the CMB dipole. We have estimated the accuracy of the LFI calibration following two strategies: (1) we have run a set of simulations to assess the impact of statistical errors and systematic effects in the instrument and in the calibration procedure; and (2) we have performed a number of internal consistency checks on the data and on the brightness temperature of Jupiter. Errors in the calibration of this Planck/LFI data release are expected to be about 0.6% at 44 and 70 GHz, and 0.8% at 30 GHz. Both these preliminary results at low and high ℓ are consistent with WMAP results within uncertainties and comparison of power spectra indicates good consistency in the absolute calibration with HFI (0.3%) and a 1.4σ discrepancy with WMAP (0.9%).

79 ASTRONOMY AND ASTROPHYSICS↗

Validation of the ESPRESSO wavelength calibration using iodine absorption cell spectra

ABSTRACT High-quality wavelength calibration is crucial for science cases like radial-velocity studies of exoplanets, the search for a possible variation of fundamental constants, and the redshift drift experiment. However, for state-of-the-art spectrographs, it has become difficult to verify the wavelength calibration on sky because no astrophysical source provides spectra with sufficiently stable or accurate wavelength information. We therefore propose to use iodine absorption cells to validate the wavelength calibration. Observing a bright and featureless star through the iodine cell emulates an astrophysical target with exactly known spectral features that can be analysed like any other science target, allowing to verify the wavelength calibration derived from the internal calibration sources and to identify systematics in the data processing. As demonstration, we temporarily installed an $\mathrm{I_2}$ absorption cell at ESPRESSO. Employing a full forward modelling approach of the $\mathrm{I_2}$ spectrum, including the instrumental line-spread function, we demonstrate wavelength calibration accuracy at the level of a few $\mathrm{m\,s^{-1}}$. We also show that wavelength measurements do depend on the geometry of the light-injection into the spectrograph fibers. This highlights the importance of probing exactly the same light path as science targets, something not possible with internal calibration sources alone. We also demonstrate excellent radial-velocity stability at the ${{< 20\, \mathrm{cm\,s^{-1}}}}$ level in a full end-to-end fashion, from sky to data product. Our study therefore showcases the great potential of absorption cells for the verification and long-term monitoring of the wavelength calibration as well as the unique insights they can provide.

Schmidt, Tobias M. (ORCID:0000000248337273)↗

Automated Calibration of Parallel and Distributed Computing Simulators: A Case Study

Many parallel and distributed computing research results are obtained in simulation, using simulators that mimic real-world executions on some target system. Each such simulator is configured by picking values for parameters that define the behavior of the underlying simulation models it implements. The main concern for a simulator is accuracy: simulated behaviors should be as close as possible to those observed in the real-world target system. This requires that values for each of the simulator's parameters be carefully picked, or “calibrated,” based on ground-truth real-world executions. Examining the current state of the art shows that simulator calibration, at least in the field of parallel and distributed computing, is often undocumented (and thus perhaps often not performed) and, when documented, is described as a labor-intensive, manual process. In this work we evaluate the benefit of automating simulation calibration using simple algorithms. Specifically, we use a real-world case study from the field of High Energy Physics and compare automated calibration to calibration performed by a domain scientist. Our main finding is that automated calibration is on par with or significantly outperforms the calibration performed by the domain scientist. Furthermore, automated calibration makes it straightforward to operate desirable tradeoffs between simulation accuracy and simulation speed.

Mc donald, Jesse↗