Search NASA⌕ Search

SEARCH · Search NASA

Results for “Camera calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Preliminary Calibration Report of an Apparatus to Measure Vibration Characteristics of Low Frequency Disturbance Source Devices

This report presents a description of the test apparatus and the method of testing the low frequency disturbance source characteristics of small pumps, fans, camera motors, and recorders that are typical of those used in microgravity science facilities. The test apparatus will allow both force and acceleration spectra of these disturbance devices to be obtained from acceleration measurements over the frequency range from 2 to 300 Hz. Some preliminary calibration results are presented.

Russell, James W.↗

A synchronous strobed laser light sheet for helicopter model rotor flow visualization

A synchronous, strobed laser light sheet has been developed for use in flow visualization of a helicopter rotor model. The light sheet strobe circuit included selectable blade position, strobe duration, and multiple pulses per revolution for rotors having 2 to 9 blades. The flow was seeded with propylene glycol. Between runs, a calibration grid board was placed in the plane of the laser sheet and recorded with the video camera at the position used to record the flow field. A slip-sync mode permitted slow motion visualization of the flow field over complete rotations of the rotor. The system was used to make two-dimensional flow field cuts of a four-bladed rotor operating at advance ratio of 0.37 at wind tunnel speeds up to 79.25 meters per second (260 feet per second).

Leighty, Bradley D.↗

Applications of Temperature and Pressure Sensitive Paints

Luminescent molecular probes imbedded in a polymer binder form a temperature or pressure paint. On excitation by light of the proper wavelength, the luminescence, which is quenched either thermally or by oxygen, is detected by a camera or photodetector. From the detected luminescent intensity, temperature and pressure can be determined. The basic photophysics, calibration, accuracy and time response of a luminescent paint is described followed by applications in low speed, transonic, supersonic and cryogenic wind tunnels and in rotating machinery.

Liu, Tian-Shu↗

Pressure and Temperature Sensitive Paint Measurements on Rotors

Luminescent molecular probes imbedded in a polymer binder form a temperature or pressure paint. On excitation by light of the proper wavelength, the luminescence, which is quenched either thermally or by oxygen, is detected by a camera or photodetector. From the detected luminescent intensity, temperature and pressure can be determined. The basic photophysics, calibration, accuracy and time response of luminescent paints is described followed by applications in wind tunnels and in rotating machinery.

Sullivan, John↗

Boundary-Layer Transition Detection in Cryogenic Wind Tunnel Using Fluorescent Paints

Luminescent molecular probes imbedded in a polymer binder form a temperature or pressure paint. On excitation by light of the proper wavelength, the luminescence, which is quenched either thermally or by oxygen, is detected by a camera or photodetector. From the detected luminescent intensity, temperature and pressure can be determined. The basic photophysics, calibration, accuracy and time response of a luminescent paints is described followed by applications in low speed, transonic, supersonic and cryogenic wind tunnels and in rotating machinery.

Sullivan, John↗

Recent Advances in Video Meteor Photometry

One of the most common (and obvious) problems with video meteor data involves the saturation of the output signal produced by bright meteors, resulting in the elimination of such meteors from photometric determinations. It is important to realize that a "bright" meteor recorded by intensified meteor camera is not what would be considered "bright" by a visual observer - indeed, many Generation II or III camera systems are saturated by meteors with a visual magnitude of 3, barely even noticeable to the untrained eye. As the relatively small fields of view (approx.30 ) of the camera systems captures at best modest numbers of meteors, even during storm peaks, the loss of meteors brighter than +3 renders the determination of shower population indices from video observations even more difficult. Considerable effort has been devoted by the authors to the study of the meteor camera systems employed during the Marshall Space Flight Center s Leonid ground-based campaigns, and a calibration scheme has been devised which can extend the useful dynamic range of such systems by approximately 4 magnitudes. The calibration setup involves only simple equipment, available to amateur and professional, and it is hoped that use of this technique will make for better meteor photometry, and move video meteor analysis beyond the realm of simple counts.

Swift, Wesley R.↗

Wavefront Sensing and Control Architecture for the Spherical Primary Optical Telescope (SPOT)

Testbed results are presented demonstrating high-speed image-based wavefront sensing and control for a spherical primary optical telescope (SPOT). The testbed incorporates a phase retrieval camera coupled to a 3-Mirror Vertex testbed (3MV) at the NASA Goddard Space Flight Center. Actuator calibration based on the Hough transform is discussed as well as several supercomputing archtectures for image-based wavefront sensing. Timing results are also presented based on various algorithm implementations using a cluster of 64 TigerShare TSlOl DSP's (digital-signal processors).

Dean, Bruce H.↗

Multiple Waveband Temperature Sensor (MWTS)

This slide presentation reviews the development of Multiple Waveband Temperature Sensor (MWTS). The MWTS project will result in a highly stable, monolithically integrated, high resolution infrared detector array sensor that records registered thermal imagery in four infrared wavebands to infer dynamic temperature profiles on a laser-irradiated ground target. An accurate surface temperature measurement of a target in extreme environments in a non-intrusive manner is required. The development challenge is to: determine optimum wavebands (suitable for target temperatures, nature of the targets and environments) to measure accurate target surface temperature independent of the emissivity, integrate simultaneously readable multiband Quantum Well Infrared Photodetectors (QWIPs) in a single monolithic focal plane array (FPA) sensor and to integrate the hardware/software and system calibration for remote temperature measurements. The charge was therefore to develop and demonstrate a multiband infrared imaging camera with the detectors simultaneously sensitive to multiple distinct color bands for front surface temperature measurements Wavelength ( m) measurements. Amongst the requirements are: that the measurement system will not affect target dynamics or response to the laser irradiation and that the simplest criterion for spectral band selection is to choose those practically feasible spectral bands that create the most contrast between the objects or scenes of interest in the expected environmental conditions. There is in the presentation a review of the modeling and simulation of multi-wave infrared temperature measurement and also a review of the detector development and QWIP capacities.

infrared photodector↗

NASA Tech Briefs, September 2010

Topics covered include: Instrument for Measuring Thermal Conductivity of Materials at Low Temperatures; Multi-Axis Accelerometer Calibration System; Pupil Alignment Measuring Technique and Alignment Reference for Instruments or Optical Systems; Autonomous System for Monitoring the Integrity of Composite Fan Housings; A Safe, Self-Calibrating, Wireless System for Measuring Volume of Any Fuel at Non-Horizontal Orientation; Adaptation of the Camera Link Interface for Flight-Instrument Applications; High-Performance CCSDS Encapsulation Service Implementation in FPGA; High-Performance CCSDS AOS Protocol Implementation in FPGA; Advanced Flip Chips in Extreme Temperature Environments; Diffuse-Illumination Systems for Growing Plants; Microwave Plasma Hydrogen Recovery System; Producing Hydrogen by Plasma Pyrolysis of Methane; Self-Deployable Membrane Structures; Reactivation of a Tin-Oxide-Containing Catalys; Functionalization of Single-Wall Carbon Nanotubes by Photo-Oxidation; Miniature Piezoelectric Macro-Mass Balance; Acoustic Liner for Turbomachinery Applications; Metering Gas Strut for Separating Rocket Stages; Large-Flow-Area Flow-Selective Liquid/Gas Separator; Counterflowing Jet Subsystem Design; Water Tank with Capillary Air/Liquid Separation; True Shear Parallel Plate Viscometer; Focusing Diffraction Grating Element with Aberration Control; Universal Millimeter-Wave Radar Front End; Mode Selection for a Single-Frequency Fiber Laser; Qualification and Selection of Flight Diode Lasers for Space Applications; Plenoptic Imager for Automated Surface Navigation; Maglev Facility for Simulating Variable Gravity; Hybrid AlGaN-SiC Avalanche Photodiode for Deep-UV Photon Detection; High-Speed Operation of Interband Cascade Lasers; 3D GeoWall Analysis System for Shuttle External Tank Foreign Object Debris Events; Charge-Spot Model for Electrostatic Forces in Simulation of Fine Particulates; Hidden Statistics Approach to Quantum Simulations; Reconstituted Three-Dimensional Interactive Imaging; Determining Atmospheric-Density Profile of Titan; Digital Microfluidics Sample Analyzer; Radiation Protection Using Carbon Nanotube Derivatives; Process to Selectively Distinguish Viable from Non-Viable Bacterial Cells; and TEAMS Model Analyzer.

Source record↗

Instrument Verification Tests on the Multi-Angle Imaging SpectroRadiometer (MISR)

The Multi-angle Imaging SpectroRadiometer (MISR) cameras completed detailed calibrationa done characterization testing a year ago, as reported in earlier literature. Since that time the cameras have been assembled onto a common flight optical bench, along with photodiode detector standards and diffuse calibration targets.

MISR↗

Cross-Calibration of Earth Observing System Terra Satellite Sensors MODIS and ASTER

The Advanced Spaceborne Thermal Emissive and Reflection Radiometer (ASTER) and Moderate Resolution Imaging Spectrometer (MODIS) are two of the five sensors onboard the Earth Observing System's Terra satellite. These sensors share many similar spectral channels while having much different spatial and operational parameters. ASTER is a tasked sensor and sometimes referred to a zoom camera of the MODIS that collects a full-earth image every one to two days. It is important that these sensors have a consistent characterization and calibration for continued development and use of their data products. This work uses a variety of test sites to retrieve and validate intercalibration results. The refined calibration of Collection 6 of the Terra MODIS data set is leveraged to provide the up-to-date reference for trending and validation of ASTER. Special attention is given to spatially matching radiance measurements using prelaunch spatial response characterization of MODIS. Despite differences in spectral band properties and spatial scales, ASTER-MODIS is an ideal case for intercomparison since the sensors have nearly identical views and acquisitions times and therefore can be used as a baseline of intercalibration performance of other satellite sensor pairs.

MODIS↗

Composition of faint comets

The study uses an emission line, differential imaging camera built by the Science Operations Branch. This instrument allows photometric data to be obtained over a large area of a comet in a large number of resolution elements. The detector is a 100x100 Reticon array which with interchangeable optics can give resolutions from 2" to 30" over a field of 1' to 15'. The camera through its controlling computer can simultaneously take images in on-line and continuum filters and through computer subtraction and calibration present a photometric image of the comet produced by only the emission of the molecule under study. Initial work has shown two significant problems. First the auxiliary equipment of the telescope has not allowed the unambiguous location of faint comets so that systematic observations could be made, and secondly initial data has not shown much molecular emission from the faint comets which were located. Work last year on a software and hardware display system and this year on additional guide motors on the 36-inch telescope has allowed the differential camera to act as its own finder and guide scope. Comet IRAS was observed in C2 and CO+, as well as an occultation by the comet of SAO029103. The perodic comet Giacobini-Zinner was also observed in C2.

Brown, L. W.↗

Video Mosaicking for Inspection of Gas Pipelines

A vision system that includes a specially designed video camera and an image-data-processing computer is under development as a prototype of robotic systems for visual inspection of the interior surfaces of pipes and especially of gas pipelines. The system is capable of providing both forward views and mosaicked radial views that can be displayed in real time or after inspection. To avoid the complexities associated with moving parts and to provide simultaneous forward and radial views, the video camera is equipped with a wide-angle (>165 ) fish-eye lens aimed along the axis of a pipe to be inspected. Nine white-light-emitting diodes (LEDs) placed just outside the field of view of the lens (see Figure 1) provide ample diffuse illumination for a high-contrast image of the interior pipe wall. The video camera contains a 2/3-in. (1.7-cm) charge-coupled-device (CCD) photodetector array and functions according to the National Television Standards Committee (NTSC) standard. The video output of the camera is sent to an off-the-shelf video capture board (frame grabber) by use of a peripheral component interconnect (PCI) interface in the computer, which is of the 400-MHz, Pentium II (or equivalent) class. Prior video-mosaicking techniques are applicable to narrow-field-of-view (low-distortion) images of evenly illuminated, relatively flat surfaces viewed along approximately perpendicular lines by cameras that do not rotate and that move approximately parallel to the viewed surfaces. One such technique for real-time creation of mosaic images of the ocean floor involves the use of visual correspondences based on area correlation, during both the acquisition of separate images of adjacent areas and the consolidation (equivalently, integration) of the separate images into a mosaic image, in order to insure that there are no gaps in the mosaic image. The data-processing technique used for mosaicking in the present system also involves area correlation, but with several notable differences: Because the wide-angle lens introduces considerable distortion, the image data must be processed to effectively unwarp the images (see Figure 2). The computer executes special software that includes an unwarping algorithm that takes explicit account of the cylindrical pipe geometry. To reduce the processing time needed for unwarping, parameters of the geometric mapping between the circular view of a fisheye lens and pipe wall are determined in advance from calibration images and compiled into an electronic lookup table. The software incorporates the assumption that the optical axis of the camera is parallel (rather than perpendicular) to the direction of motion of the camera. The software also compensates for the decrease in illumination with distance from the ring of LEDs.

Magruder, Darby↗

Combining In-situ Diagnostics and Data Analytics for Discovery of Process-Structure-Property Relationships in AM parts – A Step Toward Digital Twins

In-situ additive manufacturing (AM) diagnostic tools (e.g., optical/infrared imaging, acoustic, etc.) already exist to correlate process anomalies to printed part defects. This current work aimed to augment existing capabilities by: 1) Incorporating in-situ imaging w/ machine learning (ML) image processing software (ORNL- developed "Peregrine") for AM process anomaly detection 2) Synchronizing multiple in-situ sensors for simultaneous analysis of AM build events 3) Correlating in-situ AM process data, generated part defects and part mechanical properties The key R&D question investigated was to determine if these new combined hardware/software tools could be used to successfully quantify defect distributions for parts build via SNL laser powder bed fusion (LPBF) machines, aiming to better understand data-driven process-structure-property- performance relationships. High resolution optical cameras and acoustic microphones were successfully integrated in two LPBF machines and linked to the Peregrine ML software. The software was successfully calibrated on both machines and used to image hundreds of layers of multiple builds to train the ML software in identifying printed part vs powder. The software's validation accuracy to identify this aspect increased from 56% to 98.8% over three builds. Lighting conditions inside the chamber were found to significantly impact ML algorithm predictions from in-situ sensors, so these were tailored to each machine's internal framework. Finally, 3D part reconstructions were successfully generated for a build from the compressed stack of layer-wise images. Resolution differences nearest and furthest from the optical camera were discussed. Future work aims to improve optical resolution, increase process anomalies identified, and integrate more sensor modalities.

36 MATERIALS SCIENCE↗

Advancements in reflected target nonintrusive assessment (ReTNA) for large optical surface measurement

Reflected computer vision targets are a powerful tool for measurement of mirror surface shape, with several important advantages over traditional fringe deflectometry methods. This method was first presented in 2021 and has undergone significant improvement and demonstration since. We describe a new baseline system using reflected computer vision targets, and present results from a large-scale measurement campaign conducted on both commercial heliostats and test mirrors in the laboratory. Calibration of the measurement system with photogrammetry allows for accurate measurement without careful control of target shape or camera position. Overall, the results show that a baseline setup using this method achieves measurement uncertainties in the slope error root-mean-square less than ±0.11 milliradian due to a series of repeatability conditions, varying sample position, rotation, lighting, camera settings, and system rebuild and recalibration. We present a detailed description of the setup, the results generated by this measurement tool, repeated measurement results, and the strengths and limitations of this metrology system.

14 SOLAR ENERGY↗

Surface Measurement Techniques Temperature and Pressure Sensitive Paints

Luminescent molecular probes imbedded in a polymer binder form a temperature or pressure paint. On excitation by light of the proper wavelength, the luminescence,which is quenched either thermally or by oxygen, is detected by a camera or photodetector. From the detected luminescent intensity, temperature and pressure can be determined. Tl e basic photophysics, calibration, accuracy and the response of a luminescent paints is described followed by applications in wind tunnels and in rotating machinery.

Sullivan, John P.↗

Spectroscopic Measurement of the Flows in an Arc-Jet Facility

To provide the proper test conditions for various applications, the characteristics of arcjet test facilities should be known. To determine the operational characteristics of an arcjet facility, emission spectroscopy measurements have been performed and analyzed in a previous study. As an extension of the study, radiation from the free stream and the shock layer of 15 cm diameter blunt-body test articles is measured under different test conditions in the NASA Ames 20 MW Arcjet Facility. The test gas is a mixture of argon and air or N2 and argon. To capture the spatially resolved emission spectra along the stagnation streamline of the blunt-body, a CCD camera (1024 x 256 array) with .275 m Czerny-Turner spectrograph is used. The optical system is calibrated in situ using tungsten and deuterium radiation sources. The emission measurements supplement the existing data base and will help provide better understanding of the equilibration processes in the shock layer region.

Park, C. S.↗

The Calibration of the DSCOVR EPIC Multiple Visible Channel Instrument Using MODIS and VIIRS as a Reference

The Deep Space Climate Observatory (DSCOVR), launched on 11 February 2015, is a satellite positioned near the Lagrange-1 (L1) point, carrying several instruments that monitor space weather, and Earth-view sensors designed for climate studies. The Earth Polychromatic Imaging Camera (EPIC) onboard DSCOVR continuously views the sun-illuminated portion of the Earth with spectral coverage in the UV, VIS, and NIR bands. Although the EPIC instrument does not have any onboard calibration abilities, its constant view of the sunlit Earth disk provides a unique opportunity for simultaneous viewing with several other satellite instruments. This arrangement allows the EPIC sensor to be inter-calibrated using other well-characterized satellite instrument reference standards. Two such instruments with onboard calibration are MODIS, flown on Aqua and Terra, and VIIRS, onboard Suomi-NPP. The MODIS and VIIRS reference calibrations will be transferred to the EPIC instrument using both all-sky ocean and deep convective clouds (DCC) ray-matched EPIC and MODIS/VIIRS radiance pairs. An automated navigation correction routine was developed to more accurately align the EPIC and MODIS/VIIRS granules. The automated navigation correction routine dramatically reduced the uncertainty of the resulting calibration gain based on the EPIC and MODIS/VIIRS radiance pairs. The SCIAMACHY-based spectral band adjustment factors (SBAF) applied to the MODIS/ VIIRS radiances were found to successfully adjust the reference radiances to the spectral response of the specific EPIC channel for over-lapping spectral channels. The SBAF was also found to be effective for the non-overlapping EPIC channel 10. Lastly, both ray-matching techniques found no discernable trends for EPIC channel 7 over the year of publically released EPIC data.

Haney, Conor↗