Making Positive Electrodes For Sodium/Metal Chloride Cells

High coulombic yields provided by sodium/metal chloride battery in which cathode formed by impregnating sintered nickel plaque with saturated solution of nickel chloride. Charge/discharge cycling of nickel chloride electrode results in very little loss of capacity. Used in spacecraft, electric land vehicles, and other applications in which high-energy-density power systems required.

Bugga, Ratnakumar V.↗

Fault tree analysis: NiH2 aerospace cells for LEO mission

The Fault Tree Analysis (FTA) is one of several reliability analyses or assessments applied to battery cells to be utilized in typical Electric Power Subsystems for spacecraft in low Earth orbit missions. FTA is generally the process of reviewing and analytically examining a system or equipment in such a way as to emphasize the lower level fault occurrences which directly or indirectly contribute to the major fault or top level event. This qualitative FTA addresses the potential of occurrence for five specific top level events: hydrogen leakage through either discrete leakage paths or through pressure vessel rupture; and four distinct modes of performance degradation - high charge voltage, suppressed discharge voltage, loss of capacity, and high pressure.

Klein, Glenn C.↗

Experiences with the AEROnet/PSCN ATM Prototype

This paper discusses the experience gained by the AEROnet/PSCN networking team in deploying a prototype Asynchronous Transfer Mode (ATM) based network as part of the wide-area network for the Numerical Aerodynamic Simulation (NAS) Program at NASA Ames Research Center. The objectives of this prototype were to test concepts in using ATM over wide-area Internet Protocol (IP) networks and measure end-to-end system performance. This testbed showed that end-to-end ATM over a DS3 reaches approximately 80% of the throughput achieved from a FDDI to DS3 network. The 20% reduction in through-put can be attributed to the overhead associated with running ATM. As a result, we conclude that if the loss in capacity due to ATM overhead is balanced by the reduction in cost of ATM services, as compared to dedicated circuits, then ATM can be a viable alternative.

Kurak, Richard S.↗

DMAC and NMP as Electrolyte Additives for Li-Ion Cells

Dimethyl acetamide (DMAC) and N-methyl pyrrolidinone (NMP) have been found to be useful as high-temperature-resilience-enhancing additives to a baseline electrolyte used in rechargeable lithium-ion electrochemical cells. The baseline electrolyte, which was previously formulated to improve low-temperature performance, comprises LiPF6 dissolved at a concentration of 1.0 M in a mixture comprising equal volume proportions of ethylene carbonate, diethyl carbonate, and dimethyl carbonate. This and other electrolytes comprising lithium salts dissolved in mixtures of esters (including alkyl carbonates) have been studied in continuing research directed toward extending the lower limits of operating temperatures and, more recently, enhancing the high-temperature resilience of such cells. This research at earlier stages, and the underlying physical and chemical principles, were reported in numerous previous NASA Tech Briefs articles. Although these electrolytes provide excellent performance at low temperatures (typically as low as -40 C), when the affected Li-ion cells are subjected to high temperatures during storage and cycling, there occur irreversible losses of capacity accompanied by power fade and deterioration of low-temperature performance. The term "high-temperature resilience" signifies, loosely, the ability of a cell to resist such deterioration, retaining as much as possible of its initial charge/discharge capacity during operation or during storage in the fully charged condition at high temperature. For the purposes of the present development, a temperature is considered to be high if it equals or exceeds the upper limit (typically, 30 C) of the operating-temperature range for which the cells in question are generally designed.

Smart, Marshall↗

Oxide Fiber Cathode Materials for Rechargeable Lithium Cells

LiCoO2 and LiNiO2 fibers have been investigated as alternatives to LiCoO2 and LiNiO2 powders used as lithium-intercalation compounds in cathodes of rechargeable lithium-ion electrochemical cells. In making such a cathode, LiCoO2 or LiNiO2 powder is mixed with a binder [e.g., poly(vinylidene fluoride)] and an electrically conductive additive (usually carbon) and the mixture is pressed to form a disk. The binder and conductive additive contribute weight and volume, reducing the specific energy and energy density, respectively. In contrast, LiCoO2 or LiNiO2 fibers can be pressed and sintered to form a cathode, without need for a binder or a conductive additive. The inter-grain contacts of the fibers are stronger and have fewer defects than do those of powder particles. These characteristics translate to increased flexibility and greater resilience on cycling and, consequently, to reduced loss of capacity from cycle to cycle. Moreover, in comparison with a powder-based cathode, a fiber-based cathode is expected to exhibit significantly greater ionic and electronic conduction along the axes of the fibers. Results of preliminary charge/discharge-cycling tests suggest that energy densities of LiCoO2- and LiNiO2-fiber cathodes are approximately double those of the corresponding powder-based cathodes.

Rice, Catherine E.↗

Integration Methodology For Oil-Free Shaft Support Systems: Four Steps to Success

Commercial applications for Oil-Free turbomachinery are slowly becoming a reality. Micro-turbine generators, highspeed electric motors, and electrically driven centrifugal blowers are a few examples of products available in today's commercial marketplace. Gas foil bearing technology makes most of these applications possible. A significant volume of component level research has led to recent acceptance of gas foil bearings in several specialized applications, including those mentioned above. Component tests identifying such characteristics as load carrying capacity, power loss, thermal behavior, rotordynamic coefficients, etc. all help the engineer design foil bearing machines, but the development process can be just as important. As the technology gains momentum and acceptance in a wider array of machinery, the complexity and variety of applications will grow beyond the current class of machines. Following a robust integration methodology will help improve the probability of successful development of future Oil-Free turbomachinery. This paper describes a previously successful four-step integration methodology used in the development of several Oil-Free turbomachines. Proper application of the methods put forward here enable successful design of Oil-Free turbomachinery. In addition when significant design changes or unique machinery are developed, this four-step process must be considered.

Howard, Samuel A.↗

Measurements of file transfer rates over dedicated long-haul connections

Wide-area file transfers are an integral part of several High-Performance Computing (HPC) scenarios. Dedicated network connections with high capacity, low loss rate and low competing traffic, are increasingly being provisioned over current HPC infrastructures to support such transfers. To gain insights into these file transfers, we collected transfer rate measurements for Lustre and xfs file systems between dedicated multi-core servers over emulated 10 Gbps connections with round trip times (rtt) in 0-366 ms range. Memory transfer throughput over these connections is measured using iperf, and file IO throughput on host systems is measured using xddprof. We consider two file system configurations: Lustre over IB network and xfs over SSD connected to PCI bus. Files are transferred using xdd across these connections, and the transfer rates are measured, which indicate the need to jointly optimize the connection and host file IO parameters to achieve peak transfer rates. In particular, these measurements indicate that (i) peak file transfer rate is lower than peak connection and host IO throughput, in some cases by as much as 50% or lower, (ii) xdd request sizes that achieve peak throughput for host file IO do not necessarily lead to peak file transfer rates, and (iii) parallelism in host IO and TCP transport does not always improve the file transfer rates.

log-haul connections↗

Measurements of file transfer rates over dedicated long-haul connections

Wide-area file transfers are an integral part of several High-Performance Computing (HPC) scenarios. Dedicated network connections with high capacity, low loss rate and low competing traffic, are increasingly being provisioned over current HPC infrastructures to support such transfers. To gain insights into these file transfers, we collected transfer rate measurements for Lustre and xfs file systems between dedicated multi-core servers over emulated 10 Gbps connections with round trip times (rtt) in 0-366 ms range. Memory transfer throughput over these connections is measured using iperf, and file IO throughput on host systems is measured using xddprof. We consider two file system configurations: Lustre over IB network and xfs over SSD connected to PCI bus. Files are transferred using xdd across these connections, and the transfer rates are measured, which indicate the need to jointly optimize the connection and host file IO parameters to achieve peak transfer rates. In particular, these measurements indicate that (i) peak file transfer rate is lower than peak connection and host IO throughput, in some cases by as much as 50% or lower, (ii) xdd request sizes that achieve peak throughput for host file IO do not necessarily lead to peak file transfer rates, and (iii) parallelism in host IO and TCP transport does not always improve the file transfer rates.

Rao, Nageswara S↗

Modeling Lithium Diffusion in Battery Cathodes Considering Chemo-Mechanically Induced Damage

This talk will present a 3D, continuum-level damage model for simulating Lithium diffusion within generated Li_{x}Ni_{0.5}Mn_{0.3}Co_{0.2} (NMC 532) secondary cathode particles. The primary motivation of the particle-level model is to inform cathode-particle design and determine charging profiles that reduce cathode fracture. The model considers NMC 532 secondary particles containing an agglomeration of anisotropic, randomly oriented grains. The model predicts that secondary-particle fracture is primarily due to non-ideal grain interactions with slight dependence on high-rate charge demands. The model predicts that small secondary-particles with large grains develop significantly less damage than larger secondary particles with small grains. Finally, the model predicts most of the chemo-mechanical damage accumulates in the first high-rate cycles. This chemo-mechanical “damage saturation” effect indicates that initial secondary-particle fracture occurs within the first few cycles, while long-term cathode degradation is not solely chemo-mechanically induced.

47 OTHER INSTRUMENTATION↗

TPSAS-NF1676L-14313-DND

Wake vortices limit capacity - Data indicate that current spacing standards are often very conservative - Not weather dependent, but worstcase - Loss of airport capacity in poor weather operations - Loss of visual approaches - Loss of full use of many parallel runways This conservative spacing limits efficiency and capacity now as well as limits benefits expected from advanced NextGen super density concepts.

Neil O’Connor↗

Water and Climate Impacts on Power System Operations: The Importance of Cooling Systems and Demand Response Measures

The U.S. electricity sector is highly dependent upon water resources; changes in water temperatures and water availability can affect operational costs and the reliability of power systems. Despite the importance of water for power system operations, the effects of changes in water characteristics on multiple generators in a system are generally not modeled. Moreover, demand response measures, which can change the magnitude and timing of loads and can have beneficial impacts on power system operations, have not yet been evaluated in the context of water-related power vulnerabilities. This effort provides a first comprehensive vulnerability and cost analysis of water-related impacts on a modeled power system and the potential for demand response measures to address vulnerability and cost concerns. This study uniquely combines outputs and inputs of a water and power plant system model, production cost, model, and relative capacity value model to look at variations in cooling systems, policy-related thermal curtailments, and demand response measures to characterize costs and vulnerability for a test system. Twenty-five scenarios over the course of one year are considered: a baseline scenario as well as a suite of scenarios to evaluate six cooling system combinations, the inclusion or exclusion of policy-related thermal curtailments, and the inclusion or exclusion of demand response measures. A water and power plant system model is utilized to identify changes in power plant efficiencies resulting from ambient conditions, a production cost model operating at an hourly scale is used to calculate generation technology dispatch and costs, and a relative capacity value model is used to evaluate expected loss of carrying capacity for the test system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Well RWM019

An aquifer pumping test was conducted on the Lost Lake Aquifer Zone (LLAZ) at the recently installed recovery well RWM019 in accordance with the approved test plan (Dixon, 2020). The objective of the testing was to determine baseline well performance parameters and aquifer hydraulic conductivity. This testing consisted of a step-drawdown test to determine well performance properties, a constant pumping rate aquifer test to determine aquifer hydraulic properties, and a post-test aquifer recovery monitoring period also used to estimate aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. The specific capacity of RWM019 was determined to be approximately 2.6 gpm/ft of drawdown based on the final step of the step-drawdown test. Well efficiency was inversely related to pumping rate and decreased from 87% to 81% over a pumping range of approximately 49 to 79 gpm. The aquifer head loss coefficient was determined to be 2.3 ft/ft 3 /min and the well loss coefficient was determined to be 0.05 min 2 /ft 5 .

42 ENGINEERING↗

Hydraulic Testing of Lost Lake Aquifer Near Recovery Wells RWM018, RWM 3, and RWM 5

An aquifer pumping test was conducted on the Lost Lake Aquifer Zone (LLAZ) at the recently installed recovery well RWM018 in accordance with the approved test plan (Dixon, 2018). The objective of the testing was to determine baseline well performance parameters and aquifer hydraulic conductivity. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. The specific capacity of RWM018 was determined to be approximately 3.2 gpm/ft of drawdown. At baseline conditions (all active recovery wells operating except RWM018), RWM018 has approximately 26 ft of head above the well screen. This suggests that RWM018 can sustain a maximum pumping rate of 83 gpm with drawdown at the top of screen. Well efficiency was inversely related to pumping rate and decreased from 97% to 91% over a pumping range of approximately 20 to 55 gpm. These results suggest that RWM018 is an efficient well and does not require any further well development activities. The aquifer head loss coefficient was determined to be 2.1 ft/ft 3 /min and the well loss coefficient was determined to be 0.03 min 2 /ft 5 .

42 ENGINEERING↗

Hydraulic Testing of Lost Lake Aquifer Near Recovery Wells RWM018, RWM 3, and RWM 5

An aquifer pumping test was conducted on the Lost Lake Aquifer Zone (LLAZ) at the recently installed recovery well RWM018 in accordance with the approved test plan (Dixon, 2018). The objective of the testing was to determine baseline well performance parameters and aquifer hydraulic conductivity. Well performance parameters determine d included specific capacity, well efficiency, and head loss coefficients. The specific capacity of RWM018 was determined to be approximately 3.2 gpm/ft of drawdown. At baseline conditions (all active recovery wells operating except RWM018), RWM018 has approximately 26 ft of head above the well screen. This suggests that RWM018 can sustain a maximum pumping rate of 83 gpm with drawdown at the top of screen. Well efficiency was inversely related to pumping rate and decreased from 97% to 91% over a pumping range of approximately 20 to 55 gpm. These results suggest that RWM018 is an efficient well and does not require any further well development activities. The aquifer head loss coefficient was determined to be 2.1 ft/ft 3 /min and the well loss coefficient was determined to be 0.03 min 2 /ft 5 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the Efficacy of Repeat Voltage Holds for Conditioning and Calendar Life Testing of Graphite and Silicon Cells

Voltage-hold (V-hold) protocols have shown promise toward calendar lifetime analysis of cells with graphite (Gr) and silicon (Si) anodes. In this work, repeat V-holds are performed on Gr and Si cells paired with lithium iron phosphate cathodes to delineate their beneficial role in formation and conditioning. We find that V-hold at the top of charge supplements constant current cycling in conditioning the cell to higher capacities for both Gr and Si cells after the first V-hold. A reduced order model provides the irreversible capacity proportions of each V-hold. With each repeat V-hold, parasitic loss of lithium to the solid electrolyte interphase (SEI) decreases on both Gr and Si cells. Gr cells show the square-root-of-time capacity loss behavior within 200 h of V-hold, indicative of its fast relaxation and low impact of reference performance test cycles on the SEI growth. Lifetime estimates from repeat V-holds on Gr can reach years. Si exhibits longer transition times from kinetic to diffusion-limited SEI growth, evidenced by the 400 h and 200 h holds showing square-root-of-time and linear behavior, respectively. Lifetime predictions from repeat V-holds on Si only reach 1–2 months, highlighting its limitations. Recommended duration of V-holds for Si cells should be ≥400 h.

25 ENERGY STORAGE↗

Multimodal quantification of degradation pathways during extreme fast charging of lithium-ion batteries

Enabling fast charging of Li-ion batteries will be a key step towards realizing the technology's full potential in electric vehicles. Currently, fast charging is limited by a variety of processes that reduce cell capacity upon extended cycling. Using a multimodal approach combining incremental capacity analysis (dQ/dV), high energy X-ray diffraction (HEXRD), and mass spectrometry titration (MST), we identify specific degradation mechanisms—including Li plating, dead Li x C 6 formation, Li 2 C 2 formation, solid carbonate solid-electrolyte interphase (SEI) deposition, and loss of positive electrode active material (LAM PE )—that occur during extended fast charge cycling. We find that Li plating is the major source of capacity loss in cells cycled at 6C, while non-carbonate SEI species deposition on the graphite anode is the main source of capacity loss when cycled at 4C. We also study local degradative phenomena by examining specific ~1–5 cm 2 regions of the cells using HEXRD and MST. Here, we find that plated Li is often collocated with dead Li x C 6 , Li 2 C 2 , and solid carbonate SEI species, and these additional species cumulatively account for ~20% of the capacity lost during 6C cycling. Finally, in a cell with an anomalously high amount of LAM PE (quantified via dQ/dV), we find that regions of cathode degradation were accompanied by non-carbonate SEI products on the adjacent region of the anode. We postulate that this phenomenon arises due to crosstalk between the electrodes, wherein soluble electrolyte oxidation products formed at the delithiated cathode migrate to the graphite anode and are ultimately deposited on the graphite surface. This work demonstrates the utility of combining multiple characterization techniques to reveal a more holistic understanding of degradative phenomena that occur across multiple length scales during fast charge.