Search NASA⌕ Search

SEARCH · Search NASA

Results for “Clean Cities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

437 records · Page 25

Commercial Building Technology Demonstration (Final Scientific/Technical Report)

The background for this project was a unique and innovative concept that had been proposed and demonstrated by enVerid Systems, reducing the energy consumption in HVAC systems in commercial and public buildings by up to 50% at peak loads. The concept involves selective scrubbing of gas contaminants from indoor air as a practical substitute for outside air ventilation, the latter being the conventional practice today. This scrubbing enables recycling of most of the indoor air and significantly decreasing the amount of outside air, resulting in a reduced HVAC load and commensurate energy savings for the facility. Key to our approach is low cost scrubbing of all gas contaminants from indoor air using novel, efficient and regenerable sorbent materials. The total solution, labeled HLR (HVAC Load Reduction) is implemented by means of compact modules that can be retrofitted onto virtually any building, and utilizes novel sorbents that have been developed and brought to scale production by enVerid. Although the technology had been deployed and demonstrated, the US commercial building and HVAC markets, famously conservative with respect to innovation and new technologies, had yet to embrace the idea or the product. The overarching goal of the project was to help overcome market hesitancy and enable widespread adoption, by creating a critical mass of success stories across different regions and building types, all under oversight and verification of the DOE and NREL, to ensure credibility and accuracy. The project, overall, was a resounding success. Several installations were deployed and tested comprehensively for the impact on both energy consumption and indoor air quality, and results were not only excellent, but quantitatively in line with expectations. A total number of eight (8) installations were attempted, with 2 aborted due to building issues. Of the six successful installations, however, complete M&V was performed by NREL on 2 (Miami and NYC) and partial analysis on a third site (ArcBest), and these three, along with their results, were therefore presented from a financial and reporting standpoint. Although the number of case studies fell short of the original target of 10, we nevertheless had excellent demonstrations in vastly different climate zones: Southeast, Northeast and Midwest, and in very different building types. This included a modern high-rise office building in New York City and a University Campus health center in Miami, and a mid-rise high-density office in Arkansas. The cooling load reduction was shown to be significant, averaging 37% during the final cooling season in the Miami site. In the NYC site, the cooling energy savings were generally less, at around 12%, as expected. While this is a lower number for average/total savings, two comments are important to note: (i) the outside airflow (OA) reduction was not consistent during the data collection period, at least in part understating the attainable savings through incorrect measurement of the “high energy” reference state; and (ii) the peak impact in NYC is almost certainly as high as Miami, with critical ramifications for peak load reduction and equipment downsizing ability. Importantly, the measured energy savings in all locations were related to the outdoor climate conditions and the actual achievable reduction in outside air, very much in line with models and calculations; this leaves us with increased confidence in our understanding of the interaction between the technology and the building, and our ability to project the impact of this innovation in the future, through broad adoption. Simply put: the energy savings and load reduction impact of the HLR solution has been confirmed quantitatively. The results also confirmed the air quality objective. This may be even more significant, in that air quality is more complex and harder to measure and quantify, and the performance of the HLR as an air scrubber is the linchpin of the entire solution. In all sites, indoor air quality met or exceeded the required parameters, in terms of achieving the target (low) levels of indoor pollutants. Furthermore, the concentrations of outdoor sourced pollutants were markedly lower, as expected, mostly due to the reduction in outside air intake although in part also due to the scrubbing. The success was not immediate nor easy, and early challenges with the systems, especially (but not only) around controls and communication, caused delays in commissioning and undermined some of our M&V schedules. The good news is no fundamental issues were encountered and the number of such glitches was declining quickly by the end of the project. Other challenges had to do with coordinating the control of the building OA dampers, which the HLR needs to have in order to deliver the load reduction, but which the facility manager controls regularly and independently. This is not necessarily a problem for normal HLR operation but interferes with accurate M&V, where switching OA settings back and forth on a precise timetable is essential for clean data. The project provided valuable experience in retrofitting buildings that had been originally designed to operate with less recirculation and more outside air, and some key learnings related to the cyclical regeneration of the sorbents in the operational environment of the building. Some of these learnings gave already been incorporated into ongoing improvements in the design of the HLR module as well as the software that is used to control its operation. The cost and time of retrofit installations is much better understood; so is the test and balance procedure of the building that determines the available range of outside air reduction, which in turn determines the amount of load reduced. We had also implemented at least one annual cycle of sorbent cartridge replacement in the field, after which we tested the used sorbent to assess the rate of degradation of sorbent potency – an important factor affecting the long-term economics of HLR deployments. A notable shortfall of the project, other than the fact that the number of sites was below target, was that we had not (yet) completed testing to measure and verify (M&V) the winter energy savings. This is primarily due to late start on the NYC sites (Miami does not portend any heating savings associated with reduced outside air), combined with the issues of OA damper control. It is by no means suggested that such savings cannot be captured, only that the M&V with respect to winter in NYC has been incomplete. The value of this project and its interest to the general public are hard to overstate. The case studies created from Miami and especially from NYC have, without a doubt, opened up the interest of the broad HVAC industry to HLR in the past year. Major manufacturer reps have signed up to represent and promote the product, and dozens of top tier engineering consultants have introduced HLR as a base of design in upcoming construction and renovation projects – precisely the overarching goal of this project. These would not have happened without the highly visible installation in NYC and its ultimately satisfied customer. Furthermore, the DOE itself issued a report in late 2017 analyzing hundreds of candidate technologies for reducing energy consumption in HVAC; remarkably, the budding HLR solution ranked among the top 3(!); no doubt, its status as a viable and significant contender on this list is informed by the success of these demonstrations. And furthermore, in the wake of these demos, several major energy utilities, led by ConEdison in NYC, have endorsed the HLR solution and now routinely provide substantial cash rebates for customers choosing to incorporate the HLR in their buildings and reap the benefit of the reduced peak load as well as reduced cumulative energy demand. Last but not least, in January of 2019, as this report was being written, the HLR module won the AHR Expo Innovation Award for Green Buildings and, remarkably, the prestigious and only Product of the Year 2019, being selected by an independent professional panel of judges from AHR and ASHRAE. Given the confirmation of the enormous energy saving potential of HLR in widescale deployment, as well as ancillary but significant benefits in terms of equipment downsizing and indoor air quality, the benefit of this effort to the public speaks for itself. Accelerating adoption of HLR, without dependence on subsidies and driven by the private sector, is well under way. There is still much work to be done in terms of educating the HVAC and construction ecosystems and improving the product’s robustness and simplicity, to further facilitate the adoption of this technology and the capture of its potential value. But the American public will greatly benefit both directly and indirectly in the immediate future and beyond.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Procurement of 100 kg of Enriched Xenon for the EXO Prototype and for its Installation at WIPP

This grant supported the enriched xenon procurement, detector construction and initial operation of the EXO-200 double beta decay experiment at the Waste Isolation Pilot Plant (WIPP). The period of performance was Aug 15, 2002 to Dec 31, 2014. The primary goal of the experiment is to search for the very rare (and to date not observed) neutrino-less double beta decay. Such decay, if observed, would shed the light of the quantum-mechanical structure of neutrinos, and the origins of elementary particle masses. Another goal of the detector is to serve as prototype of a larger neutrino-less double beta decay experiment, currently being considered by DOE-OS. EXO-200 has already been extremely successful in both areas and is, in fact, leading the way world-wide in this area of fundamental physics. In the initial part of the grant the EXO-200 collaboration acquired 200kg of xenon enriched to 80% in the isotope 136 that is a candidate for double beta decay. At the time this was the largest isotope separation program carried out for fundamental science. The enrichment was done in Russia, providing a rare and valuable opportunity for US scientists to work alongside Russian colleagues, in some cases from the former closed cities of their military complex. By now the EXO-200 collaboration include institutions from the US, Canada, South Korea, China, Germany, Switzerland and Russia. Many collaborating scientists from these countries have taken shifts at WIPP or at the various remote monitoring sites world-wide. EXO-200 detector construction was completed in early 2010, with the time projection chamber (TPC) installation in the cleanrooms already placed in NeXA. Detector commissioning at WIPP followed, with the last phase, the filling of the TPC with liquid Xenon, occurring in the spring 2011. EXO-200 is described in [1]. Low background data taking started on Jun 1, 2011 and within the first month of data the 2-neutrino double beta decay of 136Xe was discovered, as reported in [2]. More data provided the best half-life measurement of any 2-neutrino double-beta decay modes [3]. Until Feb 2014 the detector ran continuously producing some of the world leading results in the field and, in particular, two of the most sensitive searches for neutrinoless double beta decay [4,5]. These measurements show that the half life of this decay is longer than 1015 times the age of the universe. This is one of the leading results in this field world-wide and succeeded to put the DOE-funded research on the world stage in a very cost-effective way. Other results from EXO-200 include a search for exotic double-beta decay modes [6], a detailed report on the state of the art background levels achieved in the detector [7], the study of rare ion and neutral atom motion and neutralization rates in liquid Xenon [8], a study of the cosmogenic backgrounds in the detector at WIPP’s depth [9], a search for Lorentz and CPT symmetries violation [10] and a search for double-beta decay to excited states [11]. In Feb 2014 the EXO-200 detector was severely disrupted by the accidents in the WIPP underground (unrelated to EXO-200). The EXO-200 operations team was able to recover the unique stockpile of enriched Xenon to high pressure cylinders and warm-up the detector to room temperature without damaging the very delicate equipment. This was a very impressive achievement as no plan had been made to complete these operations entirely from remote. This validates the robustness of well-designed liquid xenon detectors for this and other measurements in particle and nuclear astrophysics. The operations team re-gained almost regular access to the WIPP underground and the EXO-200 detector in Jan 2015 and spent calendar 2015 cleaning up the soot from the WIPP fire, assessing the damage to the EXO-200 infrastructure, correcting such damage and restarting the detector. This process was successfully carried out and culminated in the re-filling of the detector with liquid xenon, in Jan 2016. As of late Jan 2016 EXO-200 is taking data again. The collaboration is in the process of upgrading the readout electronics and restarting a radon abatement system that had been commissioned just before the Feb 2014 events. The upgraded electronics will provide lower readout noise and, in turn, better signal to background discrimination. The radon abatement system will further reduce the radon in a small air-gap between the EXO-200 cryostat and the lead shielding. In a review in Jun 2015 DOE-OS approved EXO-200 for 2.5 more years of running at the end of which we expect to improve the sensitivity to the neutrino-less double-beta decay by a factor two or three. For the last 5 years the EXO-200 detector, located in the WIPP underground, has been at the center of the hunt for new physics beyond the Standard Model of particle physics!

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements and Analyses to Enable Science for the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE)

Coastal cities provide the opportunity to characterize the substantial effects of manmade particles on marine cloud properties and processes. La Jolla lies to the north of San Diego, California, but it is often about a day directly downwind of the major pollution sources located in the ports of Los Angeles and Long Beach. The large dynamic range of aerosol particle concentrations combined with the multi-hour to multi-day persistence of stratocumulus cloud layers makes the site ideal for investigating the seasonal changes in cloud and aerosol properties as well as the quantitative relationships between cloud and aerosol properties. The Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) characterized the extent, radiative properties, aerosol interactions, and precipitation characteristics of stratocumulus clouds in the Eastern Pacific across all four seasons at two coastal sites in La Jolla. This project was designed to enhance and expand the scientific uses of the ARM AMF1 measurements from EPCAPE. The goal was to ensure meaningful observations were collected that would enable science. The project included the following objectives: (1) Reviewing the ARM AMF1 measurements [ARM, 2021a; b] and circulating a summary of the measurements each week, (2) Comparing AMF1 measurements to those provided by collaborators (including filter measurements at the pier), (3) Collecting and analyzing filter samples from Scripps Pier by Fourier Transform Infrared spectroscopy (FTIR) and X-ray Fluorescence (XRF), (4) Assisting in operations of instruments provided by Guest PIs when possible, and (5) Providing an initial compilation of EPCAPE aerosol and cloud seasonal differences. The expected outcomes of these objectives were enhanced proposals and publications using EPCAPE measurements by helping to identify instrument issues, expanded data access and awareness by distributing weekly plots and related summaries, improved source-related attribution of aerosols with elemental tracers, additional observations provided by Guest PIs, and accelerated ACI studies enabled by the compiled seasonal summaries of aerosol and cloud properties. Three examples of the science enabled by this project are findings that (i) aerosol and cloud aqueous production contributes more than half of sulfate particle mass concentration, (ii) upwind sources make chemical composition very similar at nearby sites despite local differences in meteorology, and (iii) most of the large mass concentration of semi-volatile organic components is co-emitted and co-evaporated with nitrate. Together these findings illustrate how ARM extended field campaigns in coastal regions can be used to constrain ACI processes with direct observations. By using the unique ARM suite of cloud radiative products in addition to the measured aerosol properties at a coastal location, we were able to address the more specific question of which aerosol particles cause how much of the effects on clouds. Identifying this signature in coastal areas provides an opportunity to test the representation of aerosol sources by global models in a range of clean and urban-influenced conditions.

Russell, Lynn [Univ. of California, San Diego, CA ↗

Emergent quasi-one-dimensional antiferromagnetism in the distorted kagome magnet CePtPb

CePtPb hosts a distorted kagome lattice of Ce 3+ ions, providing a clean platform to investigate how reduced local symmetry and strong spin-orbit coupling reshape frustrated magnetism. Magnetization, specific heat, and magnetocaloric effect measurements, combined with a symmetry analysis of the single-ion anisotropy, demonstrate that the local 𝑚⁢2⁢𝑚 site symmetry selects a nearly Ising-like Kramers doublet with easy axes lying within the 𝑎⁢𝑏 plane. This results in three distinct in-plane Ising directions and an overall easy-plane anisotropy. The low-energy magnetic response is well captured by a three-sublattice Ising model, which quantitatively reproduces the saturation magnetization for arbitrary in-plane field orientations, including $[110]$ and $[1\bar{⁢1}⁢0]$, as well as the ratio of the field-induced critical fields. For 𝐵∥$[110]$, the phase diagram exhibits two quantum critical points at 𝐵 c⁢1 = 0.25T and 𝐵 c⁢2 = 0.55T, arising from the sequential polarization of the three Ising sublattices. In conclusion, these results reveal that the system develops quasi-one-dimensional spin chains along the 𝑐 axis, emerging from the nominally three-dimensional crystal structure composed of stacked kagome layers, and illustrate how reduced local symmetry can drive effective dimensional reduction in rare-earth Ising magnets.

Li, Fangli [Southern University of Science and Tec↗

The Port of Los Angeles Zero- and Near-Zero-Emission Freight Facilities Shore to Store Project

The City of Los Angeles Harbor Department (Harbor Department, Port of Los Angeles) partnered with Equilon Enterprises LLC (d/b/a Shell Oil Products US) (Shell), Toyota Motor North America (Toyota), and Kenworth Truck Company (Kenworth) partnered with the Port of Hueneme, United Parcel Service, Total Transportation Services Inc., Southern Counties Express, Toyota Logistics Services, Air Liquide, National Renewable Energy Laboratory, Coalition For A Safe Environment, and the South Coast Air Quality Management District to introduce hydrogen fuel into the Southern California drayage truck market by demonstrating near-commercial heavy-duty hydrogen fuel cell electric trucks at and between freight facilities throughout the region, while continuing to lay the groundwork for battery-electric operations. The Shore to Store project built on project team experience to help realize our vision of zero-emission freight operations in the future. Ten Kenworth zero-emission Class 8 fuel cell electric trucks, integrated with Toyota’s fuel cell drive technology, were operated by United Parcel Service, Total Transportation Services Inc., Southern Counties Express, and Toyota Logistics Services in commercial service. The demonstration fleet fueled at the Shore to Store hydrogen fueling stations that were built in Ontario, California, and Wilmington, California. An additional station at the Port of Long Beach (Portal Station) was available for fueling the fleet. Portal Station was supported by grants from the California Energy Commission and South Coast Air Quality Management District and used as match funding for the Shore to Store project. The Port of Hueneme demonstrated two battery-electric yard tractors, and Toyota Logistics Services demonstrated two zero-emission forklifts at their warehouse facility, showcasing elements of the entire supply chain operating with zero emissions. This project showcased a snapshot of the zero-emission supply chain of the future, providing a model by which freight facilities can support zero-emission operations. The Shore to Store project: Demonstrated the technical feasibility of zero-emission hydrogen fueled Class 8 heavy-duty trucks and electric cargo handling equipment in rigorous goods movement operation throughout the Southern California region. Cumulatively completed 59,212 miles of zero-emission operation, with 21,650 miles driven in-service with the fleets, using hydrogen fuel cell electric Class 8 heavy-duty trucks. Operated zero-emission yard tractors for a total of 2,749.6 hours. Created direct localized emission reductions in designated disadvantaged communities, including those in zip codes 90220, 90247, 90248, 90731, 90744, 90802, and 91761. For the 59,212 miles of zero-emission operation, reduced emissions by an estimated total of 15.5 kg NOX (0.163 g/km), 1.01 kg SOX (0.0106 g/km), and 304.8 metric tonnes of CO2e (3.2 kg/km) compared to diesel baseline vehicles including both tailpipe emissions and the emissions from producing the fuel sources.

08 HYDROGEN↗