Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparison study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Independent normalization for γ -ray strength functions: The shape method

Here, the shape method, a novel approach to obtain the functional form of the γ-ray strength function (γSF), is introduced. In connection with the Oslo method the slope of the nuclear level density (NLD) and γSF can be obtained simultaneously even in the absence of neutron resonance spacing data. The foundation of the shape method lies in the primary γ-ray transitions which preserve information on the functional form of the γSF. The shape method has been applied to 56 Fe, 92 Zr, and 164 Dy, which are representative cases for the variety of situations encountered in typical NLD and γSF studies. The comparisons of results from the shape method to those from the Oslo method demonstrate that the functional form of the γSF is retained regardless of nuclear structure details or J π values of the states fed by the primary transitions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Employing ternary fission of Pu 242 as a probe of very neutron-rich matter

Detailed assessments of the ability of recent theoretical approaches to modeling existing experimental data for ternary fission confirm earlier indications that the dominant mode of cluster formation in ternary fission is clusterization in very neutron rich, very low density, essentially chemically equilibrated, nucleonic matter. An extended study and comparison of these approaches applied to ternary fission yields in the thermal neutron induced reaction 241 Pu(n th ,f) has been undertaken to refine the characterization of the source matter. Here, the resonance gas approximation has been improved taking in-medium effects on the binding energies into account. A temperature of 1.29 MeV, density of 6.7 × 10 -5 nucleons/fm 3 and proton fraction Y p = 0.035 are found to provide a good representation of yields of the ternary emitted light particles and clusters. In particular, results for Z = 1 and 2 isotopes are presented. Isotopes with larger Z are discussed, and the roles of medium and continuum effects, even at very low density are illustrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quasi-elastic neutrino charged-current scattering off {sup 12}C

The charged-current quasielastic scattering of muon neutrino on a carbon target is calculated for neutrino energy up to 2.8 GeV using the relativistic distorted-wave impulse approximation with relativistic optical potential, which was earlier successfully applied to describe the electron-nucleus data. We studied both neutrino and electron processes and have shown that the reduced exclusive cross sections for neutrino and electron scattering are similar. The nuclear and axial vector mass effects on the shape of Q{sup 2} distribution have also been studied. The comparison of the (anti-)neutrino total cross sections per (proton)neutron, calculated for the carbon and oxygen targets, shows the cross sections for oxygen to be lower than those for carbon. A significant nuclear model dependence of inclusive and total cross sections for energy about 1 GeV was found.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy dependence of p-bar/p ratio in p+p collisions

We compiled the experimentally measured p-bar/p ratio at midrapidity in p+p collisions from {radical}(s)=23 to 7000 GeV and compared it to various mechanisms of baryon production as implemented in the pythia, phojet, and Heavy Ion Jet Interaction Generator (HIJING)/B-B models. For the models studied with default settings, phojet has the best agreement with the measurements, pythia gives a higher value for {radical}(s)<200 GeV, and the ratios from HIJING/B-B are consistently lower for all the {radical}(s) studied. A comparison of the data to different mechanisms of baryon production as implemented in pythia shows that through a suitable tuning of the suppression of diquark-antidiquark pair production in the color field relative to quark-antiquark production and allowing the diquarks to split according to the popcorn scheme, a fairly reasonable description of the measured p-bar/p ratio for {radical}(s)<200 GeV is given. A comparison of the beam energy dependence of the p-bar/p ratio in p+p and nucleus-nucleus (A + A) collisions at midrapidity shows that the baryon production is significantly more for A + A collisions relative to p+p collisions for {radical}(s)<200 GeV. We also carry out a phenomenological fit to the y{sub beam} dependence of the p-bar/p ratio.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Applying Bayesian parameter estimation to relativistic heavy-ion collisions: Simultaneous characterization of the initial state and quark-gluon plasma medium

We quantitatively estimate properties of the quark-gluon plasma created in ultrarelativistic heavy-ion collisions utilizing Bayesian statistics and a multiparameter model-to-data comparison. The study is performed using a recently developed parametric initial condition model, T R ENTo, which interpolates among a general class of particle production schemes, and a modern hybrid model which couples viscous hydrodynamics to a hadronic cascade.We calibrate the model to multiplicity, transverse momentum, and flow data and report constraints on the parametrized initial conditions and the temperature-dependent transport coefficients of the quark-gluon plasma. We show that initial entropy deposition is consistent with a saturation-based picture, extract a relation between the minimum value and slope of the temperature-dependent specific shear viscosity, and find a clear signal for a nonzero bulk viscosity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermodynamics of lattice QCD with 3 flavors of color-sextet quarks. II. $N_t = 6$ and $N_t = 8$

Here, we have been studying QCD with two flavors of color-sextet quarks as a candidate walking-technicolor theory using lattice-QCD simulations. The evolution of the coupling constant with lattice spacing is measured at the finite-temperature chiral transition to determine if this theory is asymptotically free and hence QCD-like. The lattice spacing is varied by changing the number of lattice sites, $N_t$, in the Euclidean time direction. QCD with three flavors is studied for comparison. Since this theory is expected to be conformal, with an infrared fixed point, the coupling constant at the chiral transition should approach a nonzero value as $N_t$ becomes large. Our earlier simulations on lattices with $N_t = 4$ and $N_t = 6$ exhibited a significant decrease in coupling at the chiral transition as $N_t$ was increased. We have now extended these simulations to $N_t = 8$, and performed additional simulations at $N_t = 6$ to measure the coupling constant at the chiral transition more precisely. These indicate that while there is an appreciable decrease in coupling between $N_t = 6$ and $N_t = 8$, this is much smaller than that between $N_t = 4$ and $N_t = 6$. Thus we are hopeful that we are approaching the large- $N_t$ limit. However, further simulations at larger $N_t(s)$ are needed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Practical Event Location Estimation Algorithm for Power Transmission System Based on Triangulation and Oscillation Intensity

Event location in power systems is quite essential information for system operators to enhance control-room situational awareness capability. Therefore, it is of great importance to develop an event location estimation algorithm for transmission systems with high accuracy. With the development of wide-area measurement system (WAMS) such as FNET/GridEye, and the synchrophasor measurement devices (SMDs) such as frequency disturbance recorders (FDRs), the synchronous measurement data including frequency, voltage amplitude and phase angle can be collected and used for event location estimation. First, the phase angle and rate of change of frequency (RoCoF) trajectories are respectively used for determining two sets of wave arrival time associated with each FDR. Then, a convolutional neural network (CNN) is utilized to determine the wave arrival order to select the more suitable set of wave arrival times for a given case and to perform corresponding modifications. Next, the oscillation intensity associated with each FDR is determined based on phase angle trajectories in the center of inertia (COI) coordinate system. Finally, the multiple criteria for event location estimation are represented. In conclusion, case studies and comparisons between the proposed and previous algorithms using actual and confirmed cases in U.S. power systems are performed to demonstrate the effectiveness and improvement of the proposed algorithm in practical applications.

frequency disturbance recorder (FDR)↗

Background and Reflections on the Life Cycle Assessment Harmonization Project

Despite the ever-growing body of life cycle assessment (LCA) literature on electricity generation technologies, inconsistent methods and assumptions hamper comparison across studies and pooling of published results. Synthesis of the body of previous research is necessary to generate robust results to assess and compare environmental performance of different energy technologies for the benefit of policy makers, managers, investors, and citizens. With funding from the U.S. Department of Energy, the National Renewable Energy Laboratory initiated the LCA Harmonization Project in an effort to rigorously leverage the numerous individual studies to develop collective insights. The goals of this project were to: (1) understand the range of published results of LCAs of electricity generation technologies, (2) reduce the variability in published results that stem from inconsistent methods and assumptions, and (3) clarify the central tendency of published estimates to make the collective results of LCAs available to decision makers in the near term. The LCA Harmonization Project's initial focus was evaluating life cycle greenhouse gas (GHG) emissions from electricity generation technologies. Six articles from this first phase of the project are presented in a special supplemental issue of the Journal of Industrial Ecology on Meta-Analysis of LCA: coal (Whitaker et al. 2012), concentrating solar power (Burkhardt et al. 2012), crystalline silicon photovoltaics (PVs) (Hsu et al. 2012), thin-film PVs (Kim et al. 2012), nuclear (Warner and Heath 2012), and wind (Dolan and Heath 2012). Harmonization is a meta-analytical approach that addresses inconsistency in methods and assumptions of previously published life cycle impact estimates. It has been applied in a rigorous manner to estimates of life cycle GHG emissions from many categories of electricity generation technologies in articles that appear in this special supplemental supplemental issue, reducing the variability and clarifying the central tendency of those estimates in ways useful for decision makers and analysts. Each article took a slightly different approach, demonstrating the flexibility of the harmonization approach. Each article also discusses limitations of the current research, and the state of knowledge and of harmonization, pointing toward a path of extending and improving the meta-analysis of LCAs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-E-I-98: Dose Comparison for Pulmonary Embolism CT Studies: Single Energy Vs. Dual Energy

Purpose: The purpose of this study was to assess and compare the size specific dose estimate (SSDE), dose length product (DLP) and noise relationship for pulmonary embolism studies evaluated by single source dual energy computed tomography (DECT) against conventional CT (CCT) studies in a busy cancer center and to determine the dose savings provided by DECT. Methods: An IRB-approved retrospective study was performed to determine the CTDIvol and DLP from a subset of patients scanned with both DECT and CCT over the past five years. We were able to identify 30 breast cancer patients (6 male, 24 female, age range 24 to 81) who had both DECT and CCT studies performed. DECT scans were performed with a GE HD 750 scanner (140/80 kVp, 480 mAs and 40 mm) and CCT scans were performed with a GE Lightspeed 16 slice scanner (120 kVp, 352 mAs, 20 mm). Image noise was measured by placing an ROI and recording the standard deviation of the mean HU along the descending aorta. Results: The average DECT patient size specific dose estimate was to be 14.2 ± 1.7 mGy as compared to 22.4 ± 2.7 mGy from CCT PE studies, which is a 37% reduction in the SSDE. The average DECT DLP was 721.8 ± 84.6 mGy-cm as compared to 981.8 ± 106.1 mGy-cm for CCT, which is a 26% decrease. Compared to CCT the image noise was found to decrease by 19% when using DECT for PE studies. Conclusion: DECT SSDE and DLP measurements indicate dose savings and image noise reduction when compared to CCT. In an environment that heavily debates CT patient doses, this study confirms the effectiveness of DECT in PE imaging.

60 APPLIED LIFE SCIENCES↗

SU-D-204-06: Dose and Image Quality Evaluation of a Low-Dose Slot-Scanning X-Ray System for Pediatric Orthopedic Studies

Purpose: Children in early teens with scoliosis require repeated radiographic exams over a number of years. The EOS (EOS imaging S.A., Paris, France) is a novel low-dose slot-scanning digital radiographic system designed to produce full-spine images of a free-standing patient. The radiation dose and image quality characteristics of the EOS were evaluated relative to those of a Computed Radiography (CR) system for scoliosis imaging. Methods: For dose evaluation, a full-torso anthropomorphic phantom was scanned five times using the default standard clinical protocols for both the EOS and a CR system, which include both posteroanterior and lateral full-spine views. Optically stimulated luminescent dosimeters (OSLDs), also known as nanoDots™ (Landauer, Inc., Glenwood, IL), were placed on the phantom’s surface to measure entrance skin dose. To assess image quality, MTF curves were generated from sampling the noise levels within the high-contrast regions of a line-pair phantom. Vertical and horizontal distortions were measured for the square line-pair phantom with the EOS system to evaluate the effects of geometric magnification and misalignment with the indicated imaging plane. Results: The entrance skin dose was measured to be 0.4 to 1.1 mGy for the EOS, and 0.7 to 3.6 mGy for the CR study. MTF comparison shows that CR greatly outperforms the EOS, despite both systems having a limiting resolution at 1.8 line-pairs per mm. Vertical distortion was unaffected by phantom positioning, because of the EOS slot-scanning geometry. Horizontal distortion increased linearly with miscentering distance. Conclusion: The EOS system resulted in approximately 70% lower radiation dose than CR for full-spine images. Image quality was found to be inferior to CR. Further investigation is required to see if EOS system is an acceptable modality for performing clinically diagnostic scoliosis examinations.

60 APPLIED LIFE SCIENCES↗

SU-E-T-804: Verification of the BJR-25 Method of KQ Determination for CyberKnife Absolute Dosimetry

Purpose: Absolute calibration of the CyberKnife is performed using a 6cm-diameter cone defined at 80cm SAD. Since kQ is defined using PDD values determined using 10×10 cm fields at 100cm SSD, the PDD must be corrected in order to correctly apply the quality conversion factor. The accepted method is based on equivalent field-size conversions of PDD values using BJR25. Using the new InCise MLC system, the CK is capable of generating a rectangular field equivalent to 10×10 cm square field. In this study, a comparison is made between kQ values determined using the traditional BJR25 method and the MLC method introduced herein. Methods: First, kQ(BJR) is determined: a PDD is acquired using a 6cm circular field at 100cm SSD, its field size converted to an equivalent square, and PDD converted to a 10×10cm field using the appropriate BJR25 table. Maintaining a consistent setup, the collimator is changed, and the MLC method is used. Finally, kQ is determined using PDDs acquired with a 9.71×10.31cm at 100cm SSD. This field is produced by setting the field to a size of 7.77×8.25cm (since it is defined at 80cm SAD). An exact 10×10cm field since field size is relegated to increments of its leaf width (0.25cm). This comparison is made using an Exradin A1SL, IBA CC08, IBA CC13, and an Exradin A19. For each detector and collimator type, the beam injector was adjusted to give 5 different beam qualities; representing a range of clinical systems. Results: Averaging across all beam qualities, kQ(MLC) differed from kQ(BJR) by less than 0.15%. The difference between the values increased with detector volume. Conclusion: For CK users with standard cone collimators, the BJR25 method has been verified. For CK users the MLC system, a technique is described to determine kQ. Primary author is the President/Owner of Spectrum Medical Physics, LLC, a company which maintains contracts with Siemens Healthcare and Standard Imaging, Inc.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-SPS-04: Dosimetric Evaluation of the Dose Calculation Accuracy of Different Algorithms for Two Different Treatment Techniques During Whole Breast Irradiation

Purpose: In this study, dosimetric comparison of field in field (FIF) and intensity modulated radiation therapy (IMRT) techniques used for treatment of whole breast radiotherapy (WBRT) were made. The dosimetric accuracy of treatment planning system (TPS) for Anisotropic Analytical Algorithm (AAA) and Acuros XB (AXB) algorithms in predicting PTV and OAR doses was also investigated. Methods: Two different treatment planning techniques of left-sided breast cancer were generated for rando phantom. FIF and IMRT plans were compared for doses in PTV and OAR volumes including ipsilateral lung, heart, left ascending coronary artery, contralateral lung and the contralateral breast. PTV and OARs doses and homogeneity and conformality indexes were compared between two techniques. The accuracy of TPS dose calculation algorithms was tested by comparing PTV and OAR doses measured by thermoluminescent dosimetry with the dose calculated by the TPS using AAA and AXB for both techniques. Results: IMRT plans had better conformality and homogeneity indexes than FIF technique and it spared OARs better than FIF. While both algorithms overestimated PTV doses they underestimated all OAR doses. For IMRT plan, PTV doses, overestimation up to 2.5 % was seen with AAA algorithm but it decreased to 1.8 % when AXB algorithm was used. Based on the results of the anthropomorphic measurements for OAR doses, underestimation greater than 7 % is possible by the AAA. The results from the AXB are much better than the AAA algorithm. However, underestimations of 4.8 % were found in some of the points even for AXB. For FIF plan, similar trend was seen for PTV and OARs doses in both algorithm. Conclusion: When using the Eclipse TPS for breast cancer, AXB the should be used instead of the AAA algorithm, bearing in mind that the AXB may still underestimate all OAR doses.

60 APPLIED LIFE SCIENCES↗

SU-F-T-581: The Effect of Scanning Orientation On New EBT-XD Film Using Vidar and Epson Scanners

Purpose: To study the effect of film scanning orientation for new EBT-XD film using Vidar and Epson scanners, compared with EBT3 films. Methods: The EBT-XD (lot#01081501) and EBT3 films (lot#11031501) were cut into 4cm×7cm pieces and each film piece was uniformly exposed to a 6MV photon beam (15×15cm{sup 2}) at 5 cm depth and 100cm SAD in polystyrene phantom, one at a time. The doses delivered were 0,2.5,5,10,20,30,40 and 50 Gy for EBT-XD films, and 0,0.5,1,2,4,8,12 and 16 Gy for EBT3 films, respectively. All films were scanned at least 16 hours after irradiation, one at a time, in portrait or landscape orientation, using a Vidar DosimetryPro Advantage Red and an Epson 10000XL scanner (red channel). Each film piece was positioned at the center of a frame (36cm×36cm) with a cutout slightly larger than the film size for scanning. The scanned data (71 dpi), were analyzed using ImageJ and the average in the ROI (3cm×3cm) of each film at the center was obtained. Results: Dose response curves (netOD vs. dose) were established and compared with EBT-XD and EBT3 film in portrait or landscape orientation using these two scanners. The portrait to landscape (P/L) ratio for each film/scanner combination was determined. The EBT-XD film is about three times less sensitive than EBT3 film. The netOD is higher for portrait than landscape orientation for all the film/scanner combinations. For EBT-XD and EBT3, the average P/L ratios are 1.02 and 1.03 using Vidar scanner, and 1.03 and 1.05 using Epson scanner (red channel), respectively. Conclusion: The effect of film scanning orientation for new EBT-XD film using Vidar Advantage Red and Epson 10000XL scanners has been studied, in comparison with EBT3 film. The portrait/landscape ratios are the lowest for EBT-XD film using Vidar Advantage Red scanner among the four film/scanner combinations.

60 APPLIED LIFE SCIENCES↗

Leucine Biosynthesis Is Involved in Regulating High Lipid Accumulation in Yarrowia lipolytica

ABSTRACT The yeast Yarrowia lipolytica is a potent accumulator of lipids, and lipogenesis in this organism can be influenced by a variety of factors, such as genetics and environmental conditions. Using a multifactorial study, we elucidated the effects of both genetic and environmental factors on regulation of lipogenesis in Y. lipolytica and identified how two opposite regulatory states both result in lipid accumulation. This study involved comparison of a strain overexpressing diacylglycerol acyltransferase ( DGA1 ) with a control strain grown under either nitrogen or carbon limitation conditions. A strong correlation was observed between the responses on the transcript and protein levels. Combination of DGA1 overexpression with nitrogen limitation resulted in a high level of lipid accumulation accompanied by downregulation of several amino acid biosynthetic pathways, including that of leucine in particular, and these changes were further correlated with a decrease in metabolic fluxes. This downregulation was supported by the measured decrease in the level of 2-isopropylmalate, an intermediate of leucine biosynthesis. Combining the multi-omics data with putative transcription factor binding motifs uncovered a contradictory role for TORC1 in controlling lipid accumulation, likely mediated through 2-isopropylmalate and a Leu3-like transcription factor. IMPORTANCE The ubiquitous metabolism of lipids involves refined regulation, and an enriched understanding of this regulation would have wide implications. Various factors can influence lipid metabolism, including the environment and genetics. We demonstrated, using a multi-omics and multifactorial experimental setup, that multiple factors affect lipid accumulation in the yeast Yarrowia lipolytica . Using integrative analysis, we identified novel interactions between nutrient restriction and genetic factors involving regulators that are highly conserved among eukaryotes. Given that lipid metabolism is involved in many diseases but is also vital to the development of microbial cell factories that can provide us with sustainable fuels and oleochemicals, we envision that our report introduces foundational work to further unravel the regulation of lipid accumulation in eukaryal cells.

59 BASIC BIOLOGICAL SCIENCES↗

A Phylogeny-Based Global Nomenclature System and Automated Annotation Tool for H1 Hemagglutinin Genes from Swine Influenza A Viruses

A fundamental goal in the biological sciences is the definition of groups of organisms based on evolutionary history and the naming of those groups. For influenza A viruses (IAVs) in swine, understanding the hemagglutinin (HA) genetic lineage of a circulating strain aids in vaccine antigen selection and allows for inferences about vaccine efficacy. Previous reporting of H1 virus HA in swine relied on colloquial names, frequently with incriminating and stigmatizing geographic toponyms, making comparisons between studies challenging. To overcome this, we developed an adaptable nomenclature using measurable criteria for historical and contemporary evolutionary patterns of H1 global swine IAVs. We also developed a web-accessible tool that classifies viruses according to this nomenclature. This classification system will aid agricultural production and pandemic preparedness through the identification of important changes in swine IAVs and provides terminology enabling discussion of swine IAVs in a common context among animal and human health initiatives.

H1N1↗

Synthetic shibkovite K(K{sub 1.67}H{sub 2}O{sub 0.33})(Ca{sub 1.3}Na{sub 0.7})[Zn{sub 3}Si{sub 12}O{sub 30}]: the crystal structure and comparative crystal chemistry

The structure of a single crystal of a synthetic analog of mineral shibkovite K(K{sub 1.67}H{sub 2}O{sub 0.33})(Ca{sub 1.3}Na{sub 0.7})[Zn{sub 3}Si{sub 12}O{sub 30}] (milarite structure type) obtained by hydrothermal synthesis in the AlPO{sub 4}-K{sub 3}PO{sub 4}-CaCO{sub 3}-Na{sub 2}CO{sub 3}-ZnCO{sub 3}-SiO{sub 2}-H{sub 2}O system has been solved (R = 0.0406) by X-ray diffraction analysis: a = 10.5327(2) Å, c = 14.2019(3) Å, sp. gr. P6/mcc, Z = 2, and ρ{sub calcd} = 2.90 g/cm{sup 3}. The crystal-chemical features of the new phase are studied in comparison with the other terms of the milarite group. It is shown that the crystallization conditions for minerals and synthetic analogs of this group determine the presence or absence of crystallization water in the structures of compounds.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improvements in simulation of multiple scattering effects in ATLAS fast simulation

Fast ATLAS Tracking Simulation (Fatras) package was verified on single layer geometry with respect to full simulation with GEANT4. Fatras hadronic interactions and multiple scattering simulation were studied in comparison with GEANT4. Disagreement was found in multiple scattering distributions of primary charged particles (μ, π, e). A new model for multiple scattering simulation was implemented in Fatras. The model was based on R. Frühwirth’s mixture models. New model was tested on single layer geometry and a good agreement with GEANT4 was achieved. Also a comparison of reconstructed tracks’ parameters was performed for Inner Detector geometry, and Fatras with new multiple scattering model proved to have better agreement with GEANT4. New model of multiple scattering was added as a part of Fatras package in the development release of ATLAS software—ATHENA.

74 ATOMIC AND MOLECULAR PHYSICS↗

Comparative analysis of radiation effects on the electroluminescence of Si and SiGe/Si(001) heterostructures with self-assembled Islands

The effect of neutron radiation on the electroluminescence of the Si p-i-n diode containing a multilayered Ge/Si heterostructure with self-assembled nanoislands is studied. In comparison with bulk Si, the diodes containing Ge(Si) nanoislands exhibit a higher radiation hardness of the electroluminescence signal, which is attributed to spatial localization of charge carriers in the Ge/Si nanostructures. The spatial localization of charge carriers impedes their diffusion to radiation defects followed by nonradiative recombination at the defects. The results show the possibilities of using Ge/Si heterostructures with self-assembled nanoislands for the development of optoelectronic devices resistant to radiation.

36 MATERIALS SCIENCE↗