Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computational Method Validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Computer-aided detection of renal calculi from noncontrast CT images using TV-flow and MSER features

Purpose: Renal calculi are common extracolonic incidental findings on computed tomographic colonography (CTC). This work aims to develop a fully automated computer-aided diagnosis system to accurately detect renal calculi on CTC images. Methods: The authors developed a total variation (TV) flow method to reduce image noise within the kidneys while maintaining the characteristic appearance of renal calculi. Maximally stable extremal region (MSER) features were then calculated to robustly identify calculi candidates. Finally, the authors computed texture and shape features that were imported to support vector machines for calculus classification. The method was validated on a dataset of 192 patients and compared to a baseline approach that detects calculi by thresholding. The authors also compared their method with the detection approaches using anisotropic diffusion and nonsmoothing. Results: At a false positive rate of 8 per patient, the sensitivities of the new method and the baseline thresholding approach were 69% and 35% (p < 1e − 3) on all calculi from 1 to 433 mm{sup 3} in the testing dataset. The sensitivities of the detection methods using anisotropic diffusion and nonsmoothing were 36% and 0%, respectively. The sensitivity of the new method increased to 90% if only larger and more clinically relevant calculi were considered. Conclusions: Experimental results demonstrated that TV-flow and MSER features are efficient means to robustly and accurately detect renal calculi on low-dose, high noise CTC images. Thus, the proposed method can potentially improve diagnosis.

60 APPLIED LIFE SCIENCES↗

SU-F-T-218: Validation of An In-Vivo Proton Range Verification Method for Reducing the Risk of Permanent Alopecia in the Treatment of Pediatric Medulloblastoma

Purpose: The clinical commissioning of a workflow for pre-treatment range verification/adjustment for the head treatment of pediatric medulloblastoma patients, including dose monitoring during treatment. Methods: An array of Si-diodes (DIODES Incorporated) is placed on the patient skin on the opposite side to the beam entrance. A “scout” SOBP beam, with a longer beam range to cover the diodes in its plateau, is delivered; the measured signal is analyzed and the extracted water equivalent path lengths (WEPL) are compared to the expected values, revealing if a range correction is needed. Diodes stay in place during treatment to measure dose. The workflow was tested in solid water and head phantoms and validated against independent WEPL measurements. Both measured WEPL and skin doses were compared to computed values from the TPS (XiO); a Markus chamber was used for reference dose measurements. Results: The WEPL accuracy of the method was verified by comparing it with the dose extinction method. It resulted, for both solid water and head phantom, in the sub-millimeter range, with a deviation less than 1% to the value extracted from the TPS. The accuracy of dose measurements in the fall-off part of the dose profile was validated against the Markus chamber. The entire range verification workflow was successfully tested for the mock-treatment of head phantom with the standard delivery of 90 cGy per field per fraction. The WEPL measurement revealed no need for range correction. The dose measurements agreed to better than 4% with the prescription dose. The robustness of the method and workflow, including detector array, hardware set and software functions, was successfully stress-tested with multiple repetitions. Conclusion: The performance of the in-vivo range verification system and related workflow meet the clinical requirements in terms of the needed WEPL accuracy for pretreatment range verification with acceptable dose to the patient.

60 APPLIED LIFE SCIENCES↗

Two-phase flow with mass density contrast: Stable schemes for a thermodynamic consistent and frame-indifferent diffuse-interface model

In this paper, we present a numerical scheme for the diffuse-interface model in [3] for two-phase flow of immiscible, incompressible fluids. As that model is in particular consistent with thermodynamics, energy estimates are expected to carry over to the discrete setting. By a subtle discretization of the convective coupling with the flux of the phase-field in the momentum equation, we prove discrete consistency with thermodynamics. Numerical experiments in two spatial dimensions – ranging from Rayleigh–Taylor instability to a comparison with previous modeling approaches – indicate the full practicality of our scheme and enable a first validation of the new modeling approach in [3].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations

Purpose: The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a linear accelerator.Methods: In order to properly characterize beams from the integrated kV CBCT system, the authors have adapted a previously developed equivalent source model consisting of an equivalent spectrum module that takes into account intrinsic filtration and an equivalent filter module characterizing the added bowtie filtration. An equivalent spectrum was generated for an 80, 100, and 125 kVp beam with beam energy characterized by half-value layer measurements. An equivalent filter description was generated from bowtie profile measurements for both the full- and half-bowtie. Equivalent source models for each combination of equivalent spectrum and filter were incorporated into the Monte Carlo software package MCNPX. Monte Carlo simulations were then validated against in-phantom measurements for both the radiographic and CBCT mode of operation of the kV CBCT system. Radiographic and CBCT imaging dose was measured for a variety of protocols at various locations within a body (32 cm in diameter) and head (16 cm in diameter) CTDI phantom. The in-phantom radiographic and CBCT dose was simulated at all measurement locations and converted to absolute dose using normalization factors calculated from air scan measurements and corresponding simulations. The simulated results were compared with the physical measurements and their discrepancies were assessed quantitatively.Results: Strong agreement was observed between in-phantom simulations and measurements. For the radiographic protocols, simulations uniformly underestimated measurements by 0.54%–5.14% (mean difference =−3.07%, SD = 1.60%). For the CBCT protocols, simulations uniformly underestimated measurements by 1.35%–5.31% (mean difference =−3.42%, SD = 1.09%).Conclusions: This work demonstrates the feasibility of using a measurement-based kV CBCT source model to facilitate dose calculations with Monte Carlo methods for both the radiographic and CBCT mode of operation. While this initial work validates simulations against measurements for simple geometries, future work will involve utilizing the source model to investigate kV CBCT dosimetry with more complex anthropomorphic phantoms and patient specific models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lost and Found Opportunities Around the Chlorine Worth Study

Los Alamos National Laboratory performed a series of critical experiments in 2021 to examine the worth of chlorine in plutonium-fueled systems. This series of experiments has been dubbed the “Chlorine Worth Study,” and the evaluation of the experiments was presented to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Technical Review Group in April, 2023. The primary purpose of these experiments was to enable validation of aqueous solutions crediting neutron absorption in 35 Cl. An external, independent view of the events leading up to the design and execution of these experiments indicates a missed opportunity to leverage sensitivity/uncertainty (S/U) analysis to assert validation without the experiments by taking an additional margin for the lack of direct validation of chlorine. On the other hand, the execution of these experiments also presents a rare opportunity to examine the efficacy of the S/U approach and extract useful information about the evaluated chlorine covariance data. TSUNAMI-1D models of representative application solutions were created and used to generate sensitivity data. Varying plutonium and chlorine concentrations were considered to examine the impact of these differences on the chlorine sensitivities and uncertainties. The data-induced uncertainty in k eff resulting from chlorine was calculated directly from uncertainty information calculated in the TSUNAMI-1D sequence. In all cases, this uncertainty was less than 0.1 %Δk. This result could potentially be used to justify a reactivity margin to account for the validation gap related to chlorine in the validation set. On the other hand, given that the experiments were performed, the community should endeavor to extract as much value from them and their results as possible. The results can be used to examine the actual bias associated with chlorine in these systems once the evaluations have been released. These data can be compared with the data-induced uncertainty margin discussed above to test the sufficiency of the validation gap penalty. This result will provide an indication of the performance of the chlorine covariance data specifically and the S/U validation approach generally. More advanced S/U techniques may also be employed to determine reactivity sensitivities associated with the chlorine in the experiments, potentially generating a more robust test of the chlorine covariance data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Discovery of multimechanisms of screw dislocation interaction in bcc iron from open-ended saddle point searches

Dislocation motion and interactions determine mechanical properties in body-centered cubic (bcc) metallic materials. However, studying mechanisms for the screw dislocation interaction is fundamentally challenging since many underlying processes involve mesotimescales and atomistic resolution, currently inaccessible by either experimental techniques or continuum theoretical methods. Here, in this paper, we develop a computational capability based on self-evolving atomistic kinetic Monte Carlo (SEAKMC) to sample the critical events and saddle point energies related to screw dislocations and their junctions. The method is first validated by calculating the stress dependence of Peierls barriers and formation energies of kink pairs and cross-slip kink pairs on a single screw dislocation in bcc iron. Then the method is applied to a binary junction of a pair of intersecting screw dislocations, the structure of which is crucial for low-temperature plastic deformation. We identify three important mechanisms: coplanar cross-slipping, jog-pinning, and a previously unknown unzipping mechanism during the evolution of the binary junction. The mechanisms are then further validated using classical molecular dynamics simulations. The computational capability developed in this paper provides an effective tool to evaluate screw dislocation related thermally activated events in complex stress conditions. The mechanisms discovered in this paper provide critical insights into temperature dependence of the anomalous slip, a breakdown of the Schmidt law, during the plastic deformation in bcc iron and can be generalized to other bcc metals.

36 MATERIALS SCIENCE↗

Determining Multi-Component Phase Diagrams with Desired Characteristics Using Active Learning

Herein, we demonstrate how to predict and experimentally validate phase diagrams for multi-component systems from a high-dimensional virtual space of all possible phase diagrams involving several elements based on small existing experimental data. The experimental data for bulk phases for known systems represents a sampling from this space, and screening the space allows multi-component phase diagrams with given design criteria to be built. This approach uses machine learning methods to predict phase diagrams and Bayesian experimental design to minimize experiments for refinement and validation, all within an active learning loop. The approach is proven by predicting and synthesizing the ferroelectric ceramic system (1-ω)(Ba 0.61 Ca 0.28 Sr 0.11 TiO 3 )-ω(BaTi 0.888 Zr 0.0616 Sn 0.0028 Hf 0.0476 O 3 ) with a relatively high transition temperature and triple point, as well as the NiTi-based pseudo-binary phase diagram (1-ω)(Ti 0.309 Ni 0.485 Hf 0.20 Zr 0.006 )-ω(Ti 0.309 Ni 0.485 Hf 0.07 Zr 0.068 Nb 0.068 ) designed for high transition temperature (ω ≤ 1). Each phase diagram is validated and optimized through only three new experiments. The complexity of these compounds is beyond the reach of today’s computational methods.

36 MATERIALS SCIENCE↗

Progress and investigation on lattice Boltzmann modeling of multiple immiscible fluids or components with variable density and viscosity ratios

Lattice Boltzmann models for simulating multiphase flows are relatively new, and much work remains to be done to demonstrate their ability to solve fundamental test cases before they are considered for engineering problems. From this perspective, a hydrodynamic lattice Boltzmann model for simulating immiscible multiphase flows with high density and high viscosity ratios, up to O(1000) and O(100) respectively, is presented and validated against analytical solutions. The method is based on a two phase flow model with operators extended to handle N immiscible fluids. The current approach is O(N) in computational complexity for the number of different gradient approximations. This is a major improvement, considering the O(N{sup 2}) complexity found in most works. A sequence of systematic and essential tests have been conducted to establish milestones that need to be met by the proposed approach (as well as by other methods). First, the method is validated qualitatively by demonstrating its ability to address the spinodal decomposition of immiscible fluids. Second, the model is quantitatively verified for the case of multilayered planar interfaces. Third, the multiphase Laplace law is studied for the case of three fluids. Fourth, a quality index is developed for the three-phase Laplace–Young’s law, which concerns the position of the interfaces between the fluids resulting from the different surface tensions. The current model is compatible with the analytical solution, and is shown to be first order accurate in terms of this quality index. Finally, the multilayered Couette’s flow is studied. In this study, numerical results can recover the analytical solutions for all the selected test cases, as long as unit density ratios are considered. For high density and high viscosity ratios, the analytical solution is recovered for all tests, except that of the multilayered Couette’s flow. Numerical results and a discussion are presented for this unsuccessful test case. It is believed that other LB models may have the same problem in addressing the simulation of multiphase flows with variable density ratios.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Principal Component Geostatistical Approach for large-dimensional inverse problems

The quasi-linear geostatistical approach is for weakly nonlinear underdetermined inverse problems, such as Hydraulic Tomography and Electrical Resistivity Tomography. It provides best estimates as well as measures for uncertainty quantification. However, for its textbook implementation, the approach involves iterations, to reach an optimum, and requires the determination of the Jacobian matrix, i.e., the derivative of the observation function with respect to the unknown. Although there are elegant methods for the determination of the Jacobian, the cost is high when the number of unknowns, m, and the number of observations, n, is high. It is also wasteful to compute the Jacobian for points away from the optimum. Irrespective of the issue of computing derivatives, the computational cost of implementing the method is generally of the order of m2 n, though there are methods to reduce the computational cost. In this work, we present an implementation that utilizes a matrix free in terms of the Jacobian matrix Gauss-Newton method and improves the scalability of the geostatistical inverse problem. For each iteration, it is required to perform K runs of the forward problem, where K is not just much smaller than m but can be smaller that n. The computational and storage cost of implementation of the inverse procedure scales roughly linearly with m instead of m2 as in the textbook approach. For problems of very large m, this implementation constitutes a dramatic reduction in computational cost compared to the textbook approach. Results illustrate the validity of the approach and provide insight in the conditions under which this method perform best.

54 ENVIRONMENTAL SCIENCES↗

Nonparametric Method for Genomics-Based Prediction of Performance of Quantitative Traits Involving Epistasis in Plant Breeding

Genomic selection (GS) procedures have proven useful in estimating breeding value and predicting phenotype with genome-wide molecular marker information. However, issues of high dimensionality, multicollinearity, and the inability to deal effectively with epistasis can jeopardize accuracy and predictive ability. We, therefore, propose a new nonparametric method, pRKHS, which combines the features of supervised principal component analysis (SPCA) and reproducing kernel Hilbert spaces (RKHS) regression, with versions for traits with no/low epistasis, pRKHS-NE, to high epistasis, pRKHS-E. Instead of assigning a specific relationship to represent the underlying epistasis, the method maps genotype to phenotype in a nonparametric way, thus requiring fewer genetic assumptions. SPCA decreases the number of markers needed for prediction by filtering out low-signal markers with the optimal marker set determined by cross-validation. Principal components are computed from reduced marker matrix (called supervised principal components, SPC) and included in the smoothing spline ANOVA model as independent variables to fit the data. The new method was evaluated in comparison with current popular methods for practicing GS, specifically RR-BLUP, BayesA, BayesB, as well as a newer method by Crossa et al., RKHS-M, using both simulated and real data. Results demonstrate that pRKHS generally delivers greater predictive ability, particularly when epistasis impacts trait expression. Beyond prediction, the new method also facilitates inferences about the extent to which epistasis influences trait expression.

54 ENVIRONMENTAL SCIENCES↗

In Vivo Mouse Bioluminescence Tomography with Radionuclide-Based Imaging Validation

Introduction: Bioluminescence imaging, especially planar bioluminescence imaging, has been extensively applied in in vivo preclinical biological research. Bioluminescence tomography (BLT) has the potential to provide more accurate imaging information due to its 3D reconstruction compared with its planar counterpart. Methods: In this work, we introduce a positron emission tomography (PET) radionuclide imaging-based strategy to validate the BLT results. X-ray computed tomography, PET, spectrally resolved bioluminescence imaging, and surgical excision were performed on a tumor xenograft mouse model expressing a bioluminescent reporter gene. Results: With different spectrally resolved measured data, the BLT reconstructions were acquired based on the third-order simplified spherical harmonics (SP3) approximation and the diffusion approximation (DA). The corresponding tomographic images were obtained for validation of bioluminescence source reconstruction. Conclusion: Our results show the strength of PET imaging compared with other validation methods for BLT and improved source localization accuracy based on the SP3 approximation compared with the diffusion approximation.

59 BASIC BIOLOGICAL SCIENCES↗

Generalized approach for rapid entropy calculation of liquids and solids

We build a comprehensive methodology for the fast computation of entropy across both solid and liquid phases. The proposed method utilizes a single trajectory of molecular dynamics (MD) to facilitate the calculation of entropy, which is composed of three components. The electronic entropy is determined through the temporal average acquired from density functional theory MD simulations. The vibrational entropy, typically the predominant contributor to the total entropy, even within the liquid state, is evaluated by computing the phonon density of states via the velocity autocorrelation function. The most arduous component to quantify, the configurational entropy, is assessed by probability analysis of the local structural arrangement and atomic distribution. We illustrate, through a variety of examples, that this method is both a versatile and valid technique for characterizing the thermodynamic states of both solids and liquids. Furthermore, this method is employed to expedite the calculation of melting temperatures, demonstrating its practical utility in computational thermodynamics.

36 MATERIALS SCIENCE↗

Plans for Expanded Data Testing at ORNL [Slides]

VALID expansion is on-going and should provide coverage over a wider range of systems in the future. Adding additional application types beyond critical experiments can also be used in expanded data testing. Two other test suites have been developed at ORNL for other purposes, but never waste a good test suite. These suites are more likely to be relevant to testing differences in data as compared to assessing accuracy of evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of High-Risk Computed Tomography Features for Detection of Local Recurrence After Stereotactic Body Radiation Therapy for Early-Stage Non-Small Cell Lung Cancer

Purpose: Fibrotic changes after stereotactic body radiation therapy (SBRT) for stage I non-small cell lung cancer (NSCLC) are difficult to distinguish from local recurrences (LR), hampering proper patient selection for salvage therapy. This study validates previously reported high-risk computed tomography (CT) features (HRFs) for detection of LR in an independent patient cohort. Methods and Materials: From a multicenter database, 13 patients with biopsy-proven LR were matched 1:2 to 26 non-LR control patients based on dose, planning target volume (PTV), follow-up time, and lung lobe. Tested HRFs were enlarging opacity, sequential enlarging opacity, enlarging opacity after 12 months, bulging margin, linear margin disappearance, loss of air bronchogram, and craniocaudal growth. Additionally, 2 new features were analyzed: the occurrence of new unilateral pleural effusion, and growth based on relative volume, assessed by manual delineation. Results: All HRFs were significantly associated with LR except for loss of air bronchogram. The best performing HRFs were bulging margin, linear margin disappearance, and craniocaudal growth. Receiver operating characteristic analysis of the number of HRFs to detect LR had an area under the curve (AUC) of 0.97 (95% confidence interval [CI] 0.9-1.0), which was identical to the performance described in the original report. The best compromise (closest to 100% sensitivity and specificity) was found at ≥4 HRFs, with a sensitivity of 92% and a specificity of 85%. A model consisting of only 2 HRFs, bulging margin and craniocaudal growth, resulted in a sensitivity of 85% and a specificity of 100%, with an AUC of 0.96 (95% CI 0.9-1.0) (HRFs ≥2). Pleural effusion and relative growth did not significantly improve the model. Conclusion: We successfully validated CT-based HRFs for detection of LR after SBRT for early-stage NSCLC. As an alternative to number of HRFs, we propose a simplified model with the combination of the 2 best HRFs: bulging margin and craniocaudal growth, although validation is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Simulation with on the fly Doppler Broadening treatment in RMC

In conventional transient analysis, thermal hydraulics calculations are generally coupled to deterministic neutronics solvers. Due to the limited accuracy of deterministic methods and the rapid development of computer power, Monte Carlo neutronics calculations have received increasing attention nowadays. One of challenges for Monte Carlo methods coupled to thermal hydraulics calculations is the temperature dependent cross sections. Taking the detailed temperature distribution feedback into account, each nuclide may be in a large range of temperatures, pre-generated libraries at every temperature point are no longer applicable owing to unaffordable memory footprint. Different solutions have been proposed to deal with this problem. TMS, accounting for Doppler broadening effect by the explicit treatment of thermal motion, was used to model fast transients in Serpent 2. Stochastic mixing, using two sets of libraries for each nuclide and mixing them to get the correct temperature, was used in transient analysis by Sjenitzer and Hoogenboom. Besides, there are other on the fly Doppler broadening methods being developed, including series expansion of cross sections, multipole representation, different integration algorithms based on Doppler broadening equation. In this paper, on the fly Doppler broadening treatment based on integration algorithms was applied to transient calculation in Reactor Monte Carlo code RMC . In the following section, the integration algorithms implemented and dynamic simulation method in RMC is briefly introduced. Finally, a pure physical transient fuel assembly model was chosen for numerical validation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Implementation, capabilities, and benchmarking of Shift, a massively parallel Monte Carlo radiation transport code

This paper discusses the implementation, capabilities, and validation of Shift, a massively parallel Monte Carlo radiation transport package developed and maintained at Oak Ridge National Laboratory. It has been developed to scale well from laptop to small computing clusters to advanced supercomputers. Special features of Shift include hybrid capabilities for variance reduction such as CADIS and FW-CADIS, and advanced parallel decomposition and tally methods optimized for scalability on supercomputing architectures. Shift has been validated and verified against various reactor physics benchmarks and compares well to other state-of-the-art Monte Carlo radiation transport codes such as MCNP5, CE KENO-VI, and OpenMC. Some specific benchmarks used for verification and validation include the CASL VERA criticality test suite and several Westinghouse AP1000 ® problems. These benchmark and scaling studies show promising results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Automatic Segmentation and Online virtualCT in Head-and-Neck Adaptive Radiation Therapy

Purpose: The purpose of this work was to develop and validate an efficient and automatic strategy to generate online virtual computed tomography (CT) scans for adaptive radiation therapy (ART) in head-and-neck (HN) cancer treatment. Method: We retrospectively analyzed 20 patients, treated with intensity modulated radiation therapy (IMRT), for an HN malignancy. Different anatomical structures were considered: mandible, parotid glands, and nodal gross tumor volume (nGTV). We generated 28 virtualCT scans by means of nonrigid registration of simulation computed tomography (CTsim) and cone beam CT images (CBCTs), acquired for patient setup. We validated our approach by considering the real replanning CT (CTrepl) as ground truth. We computed the Dice coefficient (DSC), center of mass (COM) distance, and root mean square error (RMSE) between correspondent points located on the automatically segmented structures on CBCT and virtualCT. Results: Residual deformation between CTrepl and CBCT was below one voxel. Median DSC was around 0.8 for mandible and parotid glands, but only 0.55 for nGTV, because of the fairly homogeneous surrounding soft tissues and of its small volume. Median COM distance and RMSE were comparable with image resolution. No significant correlation between RMSE and initial or final deformation was found. Conclusion: The analysis provides evidence that deformable image registration may contribute significantly in reducing the need of full CT-based replanning in HN radiation therapy by supporting swift and objective decision-making in clinical practice. Further work is needed to strengthen algorithm potential in nGTV localization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Finite element analyses of single particle crushing tests incorporating computed tomography imaging and damage mechanics

Fracture of individual grains within a granular assembly affect the strength and deformation behavior of granular materials under large stress states. Interparticle forces, leading to contact stresses and ultimately fracture initiation, are influenced by particle morphology. A numerical method that incorporates both particle fracture and morphology can provide a more accurate model of a granular material’s macro-scale response. This research investigates an approach to modeling fracture initiation and propagation within individual grains, utilizing high resolution X-ray computed tomography (CT) imaging to consider grain morphology and an explicit finite element code optimized for high performance computing which incorporates damage mechanics. Using precisely measured force-displacement curves from single particle crushing tests of manufactured quartz spheres, the method is validated, and the effects of fracture properties on grain fragmentation are determined. This approach is then used to simulate single particle crushing of Ottawa sand, with grain morphology incorporated through discretized CT images. Here the effect of grain orientation on the force and applied displacement at catastrophic splitting is also explored. The proposed discrete particle based finite element framework can be applied to modeling granular assemblies, considering the effect of individual particle shape and fracture on the assembly’s deformation response through well calibrated numerical simulations.

42 ENGINEERING↗