Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computer Based Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Resonant Inelastic X-ray Scattering Calculations of Transition Metal Complexes Within a Simplified Time-Dependent Density Functional Theory Framework

We present a time-dependent density functional theory (TDDFT) approach to compute the light-matter couplings between two different manifolds of excited states relative to a common ground state in the context of 4d transition metal systems. These quantities are the necessary ingredients to solve the Kramers-Heisenberg (KH) equation for resonant inelastic X-ray scattering (RIXS) and several other types of two-photon spectroscopies. The procedure is based on the pseudo-wavefunction approach, where the solutions of a TDDFT calculation can be used to construct excited-state wave- functions, and on the restricted energy window approach, where a manifold of excited states can be rigorously defined based on the energies of the occupied molecular orbitals involved in the excitation process. Thus, the present approach bypasses the need to solve the costly TDDFT quadratic-response equations. We illustrate the applicability of the method to 4d transition metal molecular complexes by calculating the 2p4d RIXS maps of three representative ruthenium complexes and comparing them to experimental results. The method can capture all the experimental features in all three complexes to allow the assignment of the experimental peaks, and relative energies correct to within 0.6 eV at the cost of two independent TDDFT calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First principle calculations of effective exchange integrals: Comparison between SR (BS) and MR computational results

First principle calculations of effective exchange integrals (J) in the Heisenberg model for diradical species were performed by both symmetry-adapted (SA) multi-reference (MR) and broken-symmetry (BS) single reference (SR) methods. Mukherjee-type (Mk) state specific (SS) MR coupled-cluster (CC) calculations by the use of natural orbital (NO) references of ROHF, UHF, UDFT and CASSCF solutions were carried out to elucidate J values for di- and poly-radical species. Spin-unrestricted Hartree Fock (UHF) based coupled-cluster (CC) computations were also performed to these species. Comparison between UHF-NO(UNO)-MkMRCC and BS UHF-CC computational results indicated that spin-contamination of UHF-CC solutions still remains at the SD level. In order to eliminate the spin contamination, approximate spin-projection (AP) scheme was applied for UCC, and the AP procedure indeed corrected the error to yield good agreement with MkMRCC in energy. The CC double with spin-unrestricted Brueckner's orbital (UBD) was furthermore employed for these species, showing that spin-contamination involved in UHF solutions is largely suppressed, and therefore AP scheme for UBCCD removed easily the rest of spin-contamination. We also performed spin-unrestricted pure- and hybrid-density functional theory (UDFT) calculations of diradical and polyradical species. Three different computational schemes for total spin angular momentums were examined for the AP correction of the hybrid (H) UDFT. HUDFT calculations followed by AP, HUDFT(AP), yielded the S-T gaps that were qualitatively in good agreement with those of MkMRCCSD, UHF-CC(AP) and UB-CC(AP). Thus a systematic comparison among MkMRCCSD, UCC(AP) UBD(AP) and UDFT(AP) was performed concerning with the first principle calculations of J values in di- and poly-radical species. It was found that BS (AP) methods reproduce MkMRCCSD results, indicating their applicability to large exchange coupled systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advising Big Data Transfer Over Dedicated Connections Based on Profiling Optimization

Big data transfer in next-generation scientific applications is currently commonly carried out over dedicated channels in high-performance networks (HPNs), where transport protocols play a critical role in maximizing application-level throughput. Optimizing the performance of these protocols is challenging: i) transport protocols perform differently in various network environments, and the protocol choice is not straightforward; ii) even for a given protocol in a given environment, different parameter settings of the protocol may lead to significantly different performance and oftentimes the default setting does not yield the best performance. However, it is prohibitively time-consuming to conduct exhaustive transport profiling due to the large parameter space. In this paper, we propose a PRofiling Optimization Based DAta Transfer Advisor (ProbData) to help end users determine the most effective transport method with the most appropriate parameter settings to achieve satisfactory performance for big data transfer over dedicated connections in HPNs. ProbData employs a fast profiling scheme based on the Simultaneous Perturbation Stochastic Approximation algorithm, namely, FastProf, to accelerate the exploration of the optimal operational zones of various transport methods to improve profiling efficiency. We first present a theoretical background of the optimized profiling approach in ProbData and then detail its design and implementation. The advising procedure and performance benefits of FastProf and ProbData are illustrated and evaluated by both extensive emulations based on real-life performance measurements and experiments over various physical connections in existing production HPNs.

97 MATHEMATICS AND COMPUTING↗

A novel electron gun for inline MRI-linac configurations

Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered and solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0.5 T magnet without capture efficiency reduction below the experimental value in zero field. In this range of linac displacements, the electron beam generated by the new gun geometry is more effectively injected into the linac in the presence of an external magnetic field, resulting in approximately 20% increase of the target current compared to the original gun geometry behavior at zero field. The new gun geometry can generate and accelerate electron beams in external magnetic fields without current loss for fields higher than 0.11 T. The new electron-gun geometry is robust enough to function in the fringe fields of the other two magnets with a target current loss of no more than 16% with respect to the current obtained with no external magnetic fields. Conclusions: In this work, a specially designed electron gun was presented which can operate in the presence of axisymmetric strong magnetic fringe fields of MRI magnets. Computer simulations show that the electron gun can produce high quality beams which can be injected into a straight through linac such as Varian 600C and accelerated with more efficiency in the presence of the external magnetic fields. Also, the new configuration allows linac displacements along the magnet axis in a range equal to the diameter of the imaging spherical volume of the magnet under consideration. The new electron gun-linac system can function in the fringe field of a MRI magnet if the field strength at the cathode position is higher than 0.11 T. The capture efficiency of the linac depends on the magnetic field strength and the field gradient. The higher the gradient the better the capture efficiency. The capture efficiency does not degrade more than 16%.

43 PARTICLE ACCELERATORS↗

Machine Learning Classical Interatomic Potentials for Molecular Dynamics from First-Principles Training Data

The ever-increasing power of modern super-computers, along with the availability of highly scalable atomistic simulation codes, has begun to revolutionize predictive modeling of materials. In particular, molecular dynamics (MD) has led to breakthrough advances in diverse fields, including tribology, catalysis, sensing, and nanoparticle self-assembly. Furthermore, recent integration of MD simulations with X-ray characterization has demonstrated promise in real-time 3-D characterization of materials on the atomic scale. The popularity of MD is driven by its applicability at disparate length/time scales, ranging from ab initio MD (hundreds of atoms and tens of picoseconds) to all-atom classical MD (millions of atoms over microseconds), and coarse-grained (CG) models (micrometers and tens of microseconds). Nevertheless, a substantial gap persists between AIMD, which is highly accurate but restricted to extremely small sizes, and those based on classical force fields (atomistic and CG) with limited accuracy but access to larger length/time scales. The accuracy and predictive power of classical MD simulations is dictated by the empirical force fields, and their capability to capture the relevant physics. Here, we discuss some of our recent work on the use of machine learning (ML) to combine the accuracy and flexibility of electronic structure calculations with the speed of classical potentials. Our ML framework attempts to bridge the significant gulf that exists between the handful of research groups that develop new interatomic potential models (often requiring several years of effort), and the increasingly large user community from academia and industry that applies these models. Our data-driven approach represents significant departure from the status quo and involves several steps including generation and manipulation of extensive training data sets through electronic structure calculations, defining novel potential functional forms, employing state-of-the-art ML algorithms to formulate highly optimized training procedures, and subsequently developing user-friendly workflow tools integrating these algorithms on high-performance computers (HPCs). Our ML approach shows marked success in developing force fields for a wide range of materials from metals, oxides, nitrides, and heterointerfaces to two-dimensional (2D) materials.

Chan, Henry↗

Comparisons of dosimetric accuracy and calculation time of ARCHER and MCNP5 codes for the Ir-192 brachytherapy case - Paper 1

In the last decade, the graphics processing unit (GPU) technology has emerged as a viable player in high-performance computing. A GPU card is designed to carry out thousands of single instructions simultaneously, showing unprecedented computing power when compared with the traditional CPU technology. It has been proved that some computationally intensive programs can be accelerated drastically on the GPUs including Monte Carlo simulations. Unfortunately, existing production Monte Carlo codes cannot be easily ported to the GPU environment. To address the needs, a new Monte Carlo code ARCHER (Accelerated Radiation-transport Computations in Heterogeneous Environment) is being developed at Rensselaer Polytechnic Institute, employing the latest GPU and the Intel Xeon Phi coprocessor technologies. We can execute the code which was written using C and C++ on both CPU and GPU platforms. The ARCHER GPU code was written in CUDA C 5.0 and was tested on the Tesla M2090. There have been a few studies testing the ARCHER GPU code on several different platforms. In particular, Su et al has tested the ARCHER for external-beam radiation treatment 20 MeV monoenergetic monodirectional parallel electron beam. The comparison of the calculation results between EGSnrc and ARCHERGPU was impressive. A remarkable 224- fold speed-up factor was obtained using a NVIDIA Tesla M2090 GPU compared to a CPU. In this study, we applied the ARCHER code to dose calculation for a relatively new procedure, called accelerated partial breast irradiation (APBI) brachytherapy. The APBI brachytherapy dose calculation was based on RPI-AF phantom which is a 3D heterogeneous patient model. We then compared the dosimetric accuracy and calculation times of ARCHER and MCNP5 to gain insight into the accuracy and speedup of the GPU-based ARCHER code. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Accurate and efficient prediction of fine-resolution hydrologic and carbon dynamic simulations from coarse-resolution models

The topography, and the biotic and abiotic parameters are typically upscaled to make watershed-scale hydrologic-biogeochemical models computationally tractable. However, upscaling procedure can produce biases when nonlinear interactions between different processes are not fully captured at coarse resolutions. Here, we applied the Proper Orthogonal Decomposition Mapping Method (PODMM) to downscale the field solutions from a coarse (7 km) resolution grid to a fine (220 m) resolution grid. PODMM trains a reduced-order model (ROM) with coarse-resolution and fine-resolution solutions, here obtained using PAWS+CLM, a quasi-3-D watershed processes model that has been validated for many temperate watersheds. Subsequent fine-resolution solutions were approximated based only on coarse-resolution solutions and the ROM. The approximation errors were efficiently quantified using an error estimator. By jointly estimating correlated variables and temporally varying the ROM parameters, we further reduced the approximation errors by up to 20%. We also improved the method's robustness by constructing multiple ROMs using different set of variables, and selecting the best approximation based on the error estimator. The ROMs produced accurate downscaling of soil moisture, latent heat flux, and net primary production with O(1000) reduction in computational cost. The subgrid distributions were also nearly indistinguishable from the ones obtained using the fine-resolution model. Compared to coarse-resolution solutions, biases in upscaled ROM solutions were reduced by up to 80%. This method has the potential to help address the long-standing spatial scaling problem in hydrology and enable long-time integration, parameter estimation, and stochastic uncertainty analysis while accurately representing the heterogeneities.

58 GEOSCIENCES↗

AWSD Reactive Burn Model for High Explosive LX‐14

ABSTRACT The results of an Arrhenius–Wescott–Stewart–Davis (AWSD) reactive flow calibration for the HMX‐based high explosive LX‐14 are presented. The parameters in the AWSD model are calibrated to experimental thermodynamic and gas gun data and to computational results from thermochemical calculations. There is no experimental rate stick data available for LX‐14; therefore, scaled experimental results from other PBX‐based high explosives are used in the calibration to fill this gap in data. Strong agreement is observed between the calibrated AWSD model and experimental data for LX‐14, including validation data that were not used in the calibration procedure. The developed model more accurately describes experimental shock‐to‐detonation results compared to several other reactive flow models for LX‐14 from the literature. The presented results illustrate that the AWSD model is capable of quantitatively describing the reactive burn of LX‐14.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Regularized deconvolution method for turbulent combustion modeling

The modeling of filtered chemical source terms in large-eddy simulation (LES) of turbulent reacting flows remains a challenge. Deconvolution methods are an attractive technique for representing these unclosed terms. With this technique, filtered scalars are reconstructed through deconvolution. The chemical source terms that are computed directly from the deconvolved scalars are filtered explicitly to represent the turbulence-chemistry interaction. However, the approximate deconvolution method (ADM), frequently employed for non-reacting flows, exhibits shortcomings for reacting scalars. This is because ADM does not ensure essential conservation and boundedness conditions. So to address this issue, we propose a regularized deconvolution method (RDM) based on an optimization procedure. We conduct a priori and a posteriori analyses to examine RDM as a closure in LES. These investigations are performed in the context of explicit filtering. By showing that RDM is accurate and stable with respect to both the filter width and time, we conclude that the new deconvolution method shows promise in application to combustion LES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Loads on a Jacket-Supported Wind Turbine During Hurricane Sandy Simulation

Abstract The dynamic response of a jacket-supported offshore wind turbine under coupled wind, wave, and current fields during Hurricane Sandy is the subject of this study. To illustrate the detailed procedure related to the response evaluation of a 5-MW offshore wind turbine with a jacket support structure, we consider a single site where the water depth is 50 m. Loads are computed using two simulation tools, fast and abaqus, with partial coupling. Aerodynamic loads on the turbine rotor are first evaluated using a wind turbine model in fast with a fixed base; then, these rotor aerodynamic loads are applied as point loads at the top of a model of a tower that is supported by a jacket structure in abaqus. On the basis of stochastic simulations, we discuss the applicability of the abaqus jacket modeling and describe the characteristics and comparisons of the aerodynamic and hydrodynamic effects on loads on the jacket members. Details related to the structural model and soil–pile interaction model employed in the analyses are also discussed.

Engineering↗

SU-E-J-93: Development of Pre-Contoured Human Model Library in DICOM-RT Format for the Epidemiological Study of the Radiotherapy Patients

Purpose: Prior to 3D conformal radiation therapy planning, patient anatomy information was mostly limited to 2D beams-eye-view from the conventional simulator. To analyze the outcomes of such treatments for radiation late effects, 3D computational human models are often used in commercial treatment planning systems (TPSs). However, several underlying difficulties such as time-consuming manual delineation procedures of a large number of structures in the model have always limited its applications. Primary objective of this work was to develop a human model library for the epidemiological study by converting 3D-surface model organs to DICOM-RT format (DICOM-RT structure) using an in-house built software. We converted the ICRP reference human models to DICOM-RT models, which can be readily adopted for various dose calculations. Methods: MATLAB based code were utilized to convert the contour drawings extracted in text-format from the 3D graphic-tool, Rhinoceros into DICOM-RT structure format for 50 different organs of each model using a 16GB dual-core processor. The conversion periods were measured for each DICOM-RT models, and the reconstructed structure volumes were validated against the original 3D-surface models in the TPS. Ten reference hybrid whole-body models (8-pediatric and 2-adults) were automatically processed to create DICOM-RT computational human model library. Results: Mean contour conversion period was found to be 580 (N=2) and 394.5 (N=8) seconds for 50 organs in the adult and pediatric models respectively. A good agreement for large organs (NRMSD <1.0%) and small organs (NRMSD <7.7%) was also observed between the original volumes and corresponding DICOM-RT structure volumes of the organs. Conclusion: The ICRP reference human models were converted into DICOM-RT format to support the epidemiological study using a large cohort of conventional radiotherapy patients. Due to its DICOM-compatibility, the library may be implemented to many other different applications. We also expect to develop the library by including additional models in future.

60 APPLIED LIFE SCIENCES↗

Planck 2013 results. II. Low Frequency Instrument data processing

We describe the data processing pipeline of the Planck Low Frequency Instrument (LFI) data processing centre (DPC) to create and characterize full-sky maps based on the first 15.5 months of operations at 30, 44, and 70 GHz. In particular, we discuss the various steps involved in reducing the data, from telemetry packets through to the production of cleaned, calibrated timelines and calibrated frequency maps. Data are continuously calibrated using the modulation induced on the mean temperature of the cosmic microwave background radiation by the proper motion of the spacecraft. Sky signals other than the dipole are removed by an iterative procedure based on simultaneous fitting of calibration parameters and sky maps. Noise properties are estimated from time-ordered data after the sky signal has been removed, using a generalized least squares map-making algorithm. A destriping code (Madam) is employed to combine radiometric data and pointing information into sky maps, minimizing the variance of correlated noise. Noise covariance matrices, required to compute statistical uncertainties on LFI and Planck products, are also produced. Main beams are estimated down to the &approx;-20 dB level using Jupiter transits, which are also used for the geometrical calibration of the focal plane.

79 ASTRONOMY AND ASTROPHYSICS↗

A comparison of methods for melting point calculation using molecular dynamics simulations

Accurate and efficient prediction of melting points for complex molecules is still a challenging task for molecular simulation, although many methods have been developed. Four melting point computational methods, including one free energy-based method (the pseudo-supercritical path (PSCP) method) and three direct methods (two interface-based methods and the voids method) were applied to argon and a widely studied ionic liquid 1-n-butyl-3-methylimidazolium chloride ([BMIM][Cl]). The performance of each method was compared systematically. All the methods under study reproduce the argon experimental melting point with reasonable accuracy. For [BMIM][Cl], the melting point was computed to be 320 K using a revised PSCP procedure, which agrees with the experimental value 337-339 K very well. However, large errors were observed in the computed results using the direct methods, suggesting that these methods are inappropriate for large molecules with sluggish dynamics. The strengths and weaknesses of each method are discussed. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.3702587]

Zhang, Y↗

Crystal structure optimisation using an auxiliary equation of state

Standard procedures for local crystal-structure optimisation involve numerous energy and force calculations. It is common to calculate an energy–volume curve, fitting an equation of state around the equilibrium cell volume. This is a computationally intensive process, in particular, for low-symmetry crystal structures where each isochoric optimisation involves energy minimisation over many degrees of freedom. Such procedures can be prohibitive for non-local exchange-correlation functionals or other “beyond” density functional theory electronic structure techniques, particularly where analytical gradients are not available. We present a simple approach for efficient optimisation of crystal structures based on a known equation of state. The equilibrium volume can be predicted from one single-point calculation and refined with successive calculations if required. The approach is validated for PbS, PbTe, ZnS, and ZnTe using nine density functionals and applied to the quaternary semiconductor Cu{sub 2}ZnSnS{sub 4} and the magnetic metal-organic framework HKUST-1.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-84: Comparison of Three Different Systems for Patient-Specific Quality Assurance: Cranial Stereotactic Radiosurgery Using VMAT with Multiple Non Coplanar Arcs

Purpose: Patient-specific quality assurance in volumetric modulated arc therapy (VMAT) brain stereotactic radiosurgery raises specific issues on dosimetric procedures, mainly represented by the small radiation fields associated with the lack of lateral electronic equilibrium, the need of small detectors and the high dose delivered. The purpose of the study is to compare three different dosimeters for pre-treatment QA. Methods: Nineteen patients (affected by neurinomas, brain metastases, and by meningiomas) were treated with VMAT plans computed on a Monte Carlo based TPS. Gafchromic films inside a slab phantom (GF), 3-D cylindrical phantom with two orthogonal diodes array (DA), and 3-D cylindrical phantom with a single rotating ionization chambers array (ICA), have been evaluated. The dosimeters are, respectively, characterized by a spatial resolution of: 0.4 (in our method), 5 and 2.5 mm. For GF we used a double channel method for calibration and reading protocol; for DA and ICA we used the 3-D dose distributions reconstructed by the two software sold with the dosimeters. With the need of a common system for analyze different measuring approaches, we used an in-house software that analyze a single coronal plane in the middle of the phantoms and Gamma values (2% / 2 mm and 3% / 3 mm) were computed for all patients and dosimeters. Results: The percentage of points with gamma values less than one was: 95.7% for GF, 96.8% for DA and 95% for ICA, using 3%/3mm criteria, and 90.1% for GF, 92.4% for DA and 92% for ICA, using 2% / 2mm gamma criteria. Tstudent test p-values obtained by comparing the three datasets were not statistically significant for both gamma criteria. Conclusion: Gamma index analysis is not affected by different spatial resolution of the three dosimeters.

60 APPLIED LIFE SCIENCES↗

Automated Work Package: Initial Wireless Communication Platform Design, Development, and Evaluation

The Department of Energy’s Light Water Reactor Sustainability Program is developing the scientific basis to ensure long-term reliability, productivity, safety, and security of the nuclear power industry in the United States. The Instrumentation, Information, and Control (II&C) pathway of the program aims to increase the role of advanced II&C technologies to achieve this objective. One of the pathway efforts at Idaho National Laboratory (INL) is to improve the work packages execution process by replacing the expensive, inefficient, bulky, complex, and error-prone paper-based work orders with automated work packages (AWPs). An AWP is an automated and dynamic presentation of the work package designed to guide the user through the work process. It is loaded on a mobile device, such as a tablet, and is capable of communicating with plant equipment and systems to acquire plant and procedure states. The AWP replaces those functions where a computer is more efficient and reliable than a human. To enable the automatic acquisition of plant data, it is necessary to design and develop a prototype platform for data exchange between the field instruments and the AWP mobile devices. The development of the platform aims to reveal issues and solutions generalizable to large-scale implementation of a similar system. Topics such as bandwidth, robustness, response time, interference, and security are usually associated with wireless communication. These concerns, along with other requirements, are listed in an earlier INL report. Specifically, the targeted issues and performance aspects in this work are relevant to the communication infrastructure from the perspective of promptness, robustness, expandability, and interoperability with different technologies.

Automated Work Packages↗

Automated Work Package: Initial Wireless Communication Platform Design, Development, and Evaluation

The Department of Energy's Light Water Reactor Sustainability Program is developing the scientific basis to ensure long-term reliability, productivity, safety, and security of the nuclear power industry in the United States. The Instrumentation, Information, and Control (II and C) pathway of the program aims to increase the role of advanced II and C technologies to achieve this objective. One of the pathway efforts at Idaho National Laboratory (INL) is to improve the work packages execution process by replacing the expensive, inefficient, bulky, complex, and error-prone paper-based work orders with automated work packages (AWPs). An AWP is an automated and dynamic presentation of the work package designed to guide the user through the work process. It is loaded on a mobile device, such as a tablet, and is capable of communicating with plant equipment and systems to acquire plant and procedure states. The AWP replaces those functions where a computer is more efficient and reliable than a human. To enable the automatic acquisition of plant data, it is necessary to design and develop a prototype platform for data exchange between the field instruments and the AWP mobile devices. The development of the platform aims to reveal issues and solutions generalizable to large-scale implementation of a similar system. Topics such as bandwidth, robustness, response time, interference, and security are usually associated with wireless communication. These concerns, along with other requirements, are listed in an earlier INL report. Specifically, the targeted issues and performance aspects in this work are relevant to the communication infrastructure from the perspective of promptness, robustness, expandability, and interoperability with different technologies. The development of a prompt system entailed significant performance optimization, including the use of parallel processing, parallel communication, modularity, noise filtering, and frequency tuning. A robust system was achieved by enforcing a persistent continuous data exchange that automatically detects and conveys a failure of any link or component in any part of the system, and that automatically restores the communication once the link or component is restored. An expandable topology was enabled by modularity and load sharing. The number of servers, mobile devices, and field instruments is not limited from a system structure point of view. The system interoperability was achieved by enforcing the independence of the field communication application from the mobile device application. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗