Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Contaminant Removal from Oxygen Production Systems for In Situ Resource Utilization

The In Situ Resource Utilization (ISRU) project has been developing technologies to produce oxygen from lunar regolith to provide consumables to a lunar outpost. The processes developed reduce metal oxides in the regolith to produce water, which is then electrolyzed to produce oxygen. Hydrochloic and hydrofluoric acids are byproducts of the reduction processes, as halide minerals are also reduced at oxide reduction conditions. Because of the stringent water quality requirements for electrolysis, there is a need for a contaminant removal process. The Contaminant Removal from Oxygen Production Systems (CROPS) team has been developing a separation process to remove these contaminants in the gas and liquid phase that eliminates the need for consumables. CROPS has been using Nafion, a highly water selective polymeric proton exchange membrane, to recover pure water from the contaminated solution. Membrane thickness, product stream flow rate, and acid solution temperature and concentration were varied with the goal of maximizing water permeation and acid rejection. The results show that water permeation increases with increasing solution temperature and product stream flow rate, while acid rejection increases with decreasing solution temperature and concentration. Thinner membranes allowed for higher water flux and acid rejection than thicker ones. These results were used in the development of the hardware built for the most recent Mars ISRU demonstration project.

Anthony, Stephen M.↗

On Hilbert-Huang Transform Based Synthesis of a Signal Contaminated by Radio Frequency Interference or Fringes

Norden E. Huang et al. had proposed and published the Hilbert-Huang Transform (HHT) concept correspondently in 1996, 1998. The HHT is a novel method for adaptive spectral analysis of non-linear and non-stationary signals. The HHT comprises two components: - the Huang Empirical Mode Decomposition (EMD), resulting in an adaptive data-derived basis of Intrinsic Mode functions (IMFs), and the Hilbert Spectral Analysis (HSA1) based on the Hilbert Transform for 1-dimension (1D) applied to the EMD IMF's outcome. Although paper describes the HHT concept in great depth, it does not contain all needed methodology to implement the HHT computer code. In 2004, Semion Kizhner and Karin Blank implemented the reference digital HHT real-time data processing system for 1D (HHT-DPS Version 1.4). The case for 2-Dimension (2D) (HHT2) proved to be difficult due to the computational complexity of EMD for 2D (EMD2) and absence of a suitable Hilbert Transform for 2D spectral analysis (HSA2). The real-time EMD2 and HSA2 comprise the real-time HHT2. Kizhner completed the real-time EMD2 and the HSA2 reference digital implementations respectively in 2013 & 2014. Still, the HHT2 outcome synthesis remains an active research area. This paper presents the initial concepts and preliminary results of HHT2-based synthesis and its application to processing of signals contaminated by Radio-Frequency Interference (RFI), as well as optical systems' fringe detection and mitigation at design stage. The Soil Moisture Active Passive (SMAP mission (SMAP) carries a radiometer instrument that measures Earth soil moisture at L1 frequency (1.4 GHz polarimetric - H, V, 3rd and 4th Stokes parameters). There is abundant RFI at L1 and because soil moisture is a strategic parameter, it is important to be able to recover the RFI-contaminated measurement samples (15% of telemetry). State-of-the-art only allows RFI detection and removes RFI-contaminated measurements. The HHT-based analysis and synthesis facilitates recovery of measurements contaminated by all kinds of RFI, including jamming [7-8]. The fringes are inherent in optical systems and multi-layer complex contour expensive coatings are employed to remove the unwanted fringes. HHT2-based analysis allows test image decomposition to analyze and detect fringes, and HHT2-based synthesis of useful image.

Spacecraft Electronics Equipment↗

Modeling Contamination Migration on the Chandra X-Ray Observatory - III

During its first 16 years of operation, the cold (about -60 C) optical blocking filter of the Advanced CCD Imaging Spectrometer (ACIS), aboard the Chandra X-ray Observatory, has accumulated a growing layer of molecular contamination that attenuates low-energy x rays. Over the past few years, the accumulation rate, spatial distribution, and composition have changed. This evolution has motivated further analysis of contamination migration within and near the ACIS cavity, in part to evaluate potential bake-out scenarios intended to reduce the level of contamination. Keywords: X-ray astronomy, CCDs, contamination, modeling and simulation, spacecraft operations

astrophysics↗

Requirements and Sizing Investigation for the Constellation Space Suit Portable Life Support System Trace Contaminant Control

This presentation summarized the results of a trade study that evaluated whether trace contaminant control within the Constellation Spacesuit PLSS could be achieved without a Trace Contaminant Control System (TCCS) by relying on suit leakage, ullage loss from the carbon dioxide and humidity control system, and other factors. Mallory Jennings and Dr. Glenn Waguespack studied trace contaminant generation rates to verify that values reflected the latest designs for Constellation spacesuit system pressure garment materials and PLSS hardware. They also calculated TCCS sizing and conducted a literature survey to review the latest developments in trace contaminant technologies.

Jennings, Mallory A.↗

The Fate of Trace Contaminants in a Crewed Spacecraft Cabin Environment

Trace chemical contaminants produced via equipment offgassing, human metabolic sources, and vehicle operations are removed from the cabin atmosphere by active contamination control equipment and incidental removal by other air quality control equipment. The fate of representative trace contaminants commonly observed in spacecraft cabin atmospheres is explored. Removal mechanisms are described and predictive mass balance techniques are reviewed. Results from the predictive techniques are compared to cabin air quality analysis results. Considerations are discussed for an integrated trace contaminant control architecture suitable for long duration crewed space exploration missions.

Perry, Jay L.↗

Contamination and Surface Preparation Effects on Composite Bonding

Results presented here demonstrate the effect of several prebond surface contaminants (hydrocarbon, machining fluid, latex, silicone, peel ply residue, release film) on bond quality, as measured by fracture toughness and failure modes of carbon fiber reinforced epoxy substrates bonded in secondary and co-bond configurations with paste and film adhesives. Additionally, the capability of various prebond surface property measurement tools to detect contaminants and potentially predict subsequent bond performance of three different adhesives is also shown. Surface measurement methods included water contact angle, Dyne solution wettability, optically stimulated electron emission spectroscopy, surface free energy, inverse gas chromatography, and Fourier transform infrared spectroscopy with chemometrics analysis. Information will also be provided on the effectiveness of mechanical and energetic surface treatments to recover a bondable surface after contamination. The benefits and drawbacks of the various surface analysis tools to detect contaminants and evaluate prebond surfaces after surface treatment were assessed as well as their ability to correlate to bond performance. Surface analysis tools were also evaluated for their potential use as in-line quality control of adhesive bonding parameters in the manufacturing environment.

Kutscha, Eileen O.↗

Air Contamination Quantification by FTIR with Gas Cell

Air quality is of utmost importance in environmental studies and has many industrial applications such as aviators grade breathing oxygen (ABO) for pilots and breathing air for fire fighters. Contamination is a major concern for these industries as identified in MIL-PRF-27210, CGA G-4.3, CGA G-7.1, and NFPA 1989. Fourier Transform Infrared Spectroscopy (FTIR) is a powerful tool that when combined with a gas cell has tremendous potential for gas contamination analysis. Current procedures focus mostly on GC-MS for contamination quantification. Introduction of this topic will be done through a comparison of the currently used deterministic methods for gas contamination with those of FTIR gas analysis. Certification of the mentioned standards through the ISOIEC 17065 certifying body A2LA will be addressed followed by an evaluation of quality information such as the determinations of linearity and the limits of detection and quantitation. Major interferences and issues arising from the use of the FTIR for accredited work with ABO and breathing air will be covered.

Freischlag, Jason↗

Modeling Contamination Migration on the Chandra X-Ray Observatory - IV

During its first 18 years of operation, the cold (about -60degC) optical blocking filters of the Advanced CCD Imaging Spectrometer (ACIS), aboard the Chandra X-ray Observatory, has accumulated a growing layer of molecular contamination, which attenuates low-energy x rays. Over the past several years, the accumulation rate, spatial distribution, and composition have changed. This evolution has motivated further analysis of contamination migration within and near the ACIS cavity, in part to evaluate potential bake-out scenarios intended to reduce the level of contamination. This paper, the fourth on this topic, reports the results of recent contamination-migration simulations and their relevance to a decision whether to bake-out the ACIS instrument.

X-ray astronomy CCDs↗

A Review of LIBS for Real-Time Detection of Trace Silicone Contaminants on CFRP Surfaces

Laser ablation is the removal of material by laser pulses through photochemical, photothermal, or photophysical mechanisms, which is useful to prepare an adherend surface for adhesive bonding. Laser surface treatment is a method that has been under research for the past decade at NASA Langley Research Center (LaRC) to prepare surfaces for adhesive joining of aerospace composite materials and metallic alloys. Laser ablation of composite materials increases surface area and removes the surface contaminants introduced during material handling and fabrication processes. By adjustment of laser parameters, it is possible to obtain repeatable surface conditions, and superficial contaminants can be selectively and efficiently removed without damaging the underlying carbon fibers or the carbon fiber reinforced polymer (CFRP) substrate. Laser induced breakdown spectroscopy (LIBS) is a surface characterization and inspection technique that can be seamlessly integrated into the laser surface treatment process. At NASA LaRC, a single laser system has been used for both laser surface treatment and LIBS, which enables in-situ monitoring of surface contaminants. This work focuses on the advancements at LaRC using LIBS to detect surface silicone contaminants on aerospace CFRP materials and to provide surface quality control in adhesive bonding.

Rodolfo I Ledesma↗

A Review of LIBS for Real-Time Detection of Trace Silicone Contaminants on CFRP Surfaces

Laser ablation is the removal of material by laser pulses through photochemical, photothermal, or photophysical mechanisms, which is useful to prepare an adherend surface for adhesive bonding. Laser surface treatment is a method that has been under research for the past decade at NASA Langley Research Center (LaRC) to prepare surfaces for adhesive joining of aerospace composite materials and metallic alloys. Laser ablation of composite materials increases surface area and removes the surface contaminants introduced during material handling and fabrication processes. By adjustment of laser parameters, it is possible to obtain repeatable surface conditions, and superficial contaminants can be selectively and efficiently removed without damaging the underlying carbon fibers or the carbon fiber reinforced polymer (CFRP) substrate. Laser induced breakdown spectroscopy (LIBS) is a surface characterization and inspection technique that can be seamlessly integrated into the laser surface treatment process. At NASA LaRC, a single laser system has been used for both laser surface treatment and LIBS, which enables in-situ monitoring of surface contaminants. This work focuses on the advancements at LaRC using LIBS to detect surface silicone contaminants on aerospace CFRP materials and to provide surface quality control in adhesive bonding.

Rodolfo I Ledesma↗

Modelling and Laboratory Testing of Particle Resuspension and Transport for the Assessment of Terrestrial-Borne Biological Contamination of the Samples on the Mars 2020 Mission

The Mars 2020 mission will land a rover on the surface of Mars that will acquire, encapsulate, and cache scientifically selected samples of martian material for possible return to Earth by a future mission. The samples will be individually encapsulated and sealed in sample tubes. Each sample, and therefore each sample tube, must be kept clean of viable organisms with a terrestrial origin, which may adhere to the rover on their own and/or on other non-biological particles. Therefore, contrary to previous missions to the Red Planet, Mars 2020 is subject to new and more stringent biological, organic and inorganic contamination requirements. This paper reports on the analyses and testing performed to assess the various vectors that can lead to the terrestrial-borne contamination of the samples, focusing on those that are predicted to be the larger contributors. Specifically, the contamination of the sample tubes is expected to be very small prior to the commencement of the mission’s science phase since these tubes are protected by so-called Fluid Mechanical Particle Barriers. Once on the surface of Mars however the sample tubes will be removed from their FMPBs and be subject to contamination from the rover. Of specific interest is the vector by which winds dislodge some particles from the surface of the rover and transport them to the surrounding soil. Naturally, such assessments require multi-disciplinary analyses involving at minimum the physics of particle adhesion and resuspension from surfaces, fluid mechanics and aerosols. Here we provide an overview of these models. We also report on particle resuspension experiments we have performed at the Jet Propulsion Laboratory to both guide and validate the aforementioned physics models.

Steltzner, Adam↗

Molecular Identification of Microbial Contaminants

Microorganisms can have significant impacts on the success of NASA’s missions, including the integrity of materials, the reliability of scientific results, and maintenance of crew health. Robust cleaning and sterilization protocols are currently in place in NASA facilities, but agency experts agree that microbial contamination is unavoidable and its impact on NASA’s missions and science must be minimized. Therefore, it is critical to understand: 1) what specific microorganisms are present, 2) how they may impact scientific objectives, and 3) how to select appropriate mitigation strategies. The Marshall Space Flight Center (MSFC) Planetary Protection (PP) microbiology lab historically relied solely upon enumeration of culturable microbial contamination associated with spacecraft materials or cleanrooms. However, this process is time consuming, many microbes cannot be cultured, and very few can be identified with any fidelity using NASA standard microbiological methods. The work described in this white paper includes the establishment of molecular identification capabilities at MSFC, including DNA isolation, amplification, purification, and Sanger sequencing. This capability will not only improve planetary protection efforts at MSFC (i.e. by identifying contaminating microorganisms in cleanrooms or on spacecraft) but also offers a service center-wide for the identification of contaminants that arise in other projects, processing locations, or during set up and roll out of spacecraft. This work also lays the foundation for higher throughput efforts to identify large populations of microbes across the lifetime of a project and serves as the starting point for future work into whole genome sequencing, non-culture based methods, or additional characterization studies. Ultimately, accurate identification informs appropriate mitigation strategies, increasing the chances of success for NASA’s missions and objectives.

C. D. Cassilly↗

Modeling of Multicomponent Trace Contaminant Adsorption on Activated Carbon

Modeling of multicomponent trace contaminant adsorption on activated carbon for spacecraft life support applications presents challenges due to the very low contaminant concentrations in cabin air coupled with very strong adsorption of heavier components such as cyclic polydimethylsiloxanes. Both gas-phase and solid-phase micropore mass transfer resistances can be important, and competitive interactions between adsorbed components can result in behavior such as roll-up where lighter components displaced by heavier components have a higher concentration at the outlet than at the inlet. This paper describes the further development of a dynamic trace contaminant adsorption model based on Ideal Adsorbed Solution Theory (IAST). Alternative 1-dimensional and 2-dimensional versions of the model are described with different mass transfer resistance and driving force assumptions. Optimization of solution methods for speed and stability is also described. Mass balance equations are scaled to provide sensitivity over the wide range of component concentrations in cabin air. Model parameters are estimated from isotherm and breakthrough test data on single adsorbate and binary adsorbate systems. Multicomponent results are compared against predictions of a heritage model used extensively by NASA for trace contaminant control system (TCCS) carbon bed sizing. Finally, efforts to implement the model in a second software platform for wider access are described.

Kevin E Lange↗

Updated Analysis of the Trash Compaction and Processing System: Water Collected from Trash, Evaluation of the Source Contaminant Control System, and Zotek® F30 Foam Processing

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). At NASA Ames Research Center (ARC), there are two test systems: the Heat Melt Compactor (HMC), which compacts the trash into a tile with temperature and pressure, and the Source Contaminant Control System (SCCS), which is the gas management subsystem aimed to reduce contaminants by converting them into carbon dioxide (CO 2 ) and water (H 2 O) vapor. Both the HMC and SCCS serve as test systems that support TCPS development by conducting risk reduction activities associated with an ISS technology demonstration. In this paper, the risk reduction activities discussed are the testing of different trash models for operational scenarios in the HMC, investigating the water extracted from those trash models, and managing the gaseous effluents from the trash via contaminant conversion through the SCCS. The HMC has undergone several tests of different trash models and cases in which a containment bag is used or not. For the first topic, this paper will analyze the water collected and recovered from these tests and analyze the effect of specific trash containment bags. For the second topic, this paper will individually evaluate the carbon bed and catalytic oxidizer (CatOx) to understand what components the carbon bed removes and what contaminants are converted in the CatOx. For the third and final topic, this paper will discuss Zotek® F30 foam processing in the HMC unit and testing verification in correlation to defined TCPS requirements. A foam model was added to reduce the volume of foam that take up space in the ISS. Overall, this paper is a compilation and an updated analysis of tests conducted in the lab-scale TCPS at ARC within the past year.

TCPS↗

Potential Advantages to Employing an Onsite Laboratory at FUSRAP Sites Contaminated with Radionuclides and Metals - 20353

Various factors that support an evaluation of the relative costs, advantages and disadvantages of utilizing an onsite laboratory or an offsite laboratory for remediation of Formerly Utilized Sites Remedial Action Program (FUSRAP) sites contaminated with radionuclides and metals are presented. In terms of how much more quickly an onsite laboratory provides results versus an offsite laboratory, the results of this study provide tools for calculating the amount of cost savings per day for excavation of contaminated soils for various scenarios including: - State, municipal or local property remediation where the remediation schedule becomes time-critical due to the extra cost and inconvenience to the town or municipality caused by the need for increased security and safety personnel, possible road closures and detours, and the inconvenience to the public due to modified or decreased services of State or municipal facilities; - Residential property where the remediation schedule becomes time-critical due to the inconvenience to the homeowner as well as the importance of maintaining good community relations; - Commercial property where the remediation schedule becomes time-critical due to the hardship and potential loss of revenue endured by the property owner; - Open area where treatment of excavation water is required, and - Open area where treatment of excavation water is not required. For every scenario, the number of matrices, radionuclide and metal contaminants of concern and the project duration are important factors. The costs for the onsite laboratory included the capital costs associated with setting up the lab such as trailer(s) or building(s), power and water hookup, analytical testing equipment, balances, computers, desks and bookcases; support equipment such as hot plates, filtration assemblies, safety equipment, ovens, etc.; and supplies such as glassware, pipettes, filters, etc. and ongoing costs such as labor, chemicals and reagents, standards, cost of the laboratory obtaining certification and maintenance. Offsite laboratory sample testing costs are generally very competitive and typically substantially lower than onsite laboratory costs if only the sample testing costs are considered. The great disadvantage of using an offsite laboratory is that they often cannot guarantee rapid turnaround times for results which creates project delays associated with the remediation process including delays determining the completeness of the characterization and remediation processes, delays in backfilling a property and additional costs for treating wastewater (excavation water, stormwater or both). These costs will vary greatly depending upon the area of the country in which the project is located due to the wide range of labor costs for the onsite laboratory and field workers, as well as the contaminants of interest, matrices and most importantly the size of the impacted area and the number of properties located in that area. This paper provides guidelines for calculating the cost savings that may be realized if an onsite laboratory can generate results more quickly than an offsite laboratory by estimating the costs associated with the remediation process for the various scenarios noted above such as work crew labor costs, excavator and dump truck equipment rentals, wastewater treatment costs (if applicable) and the additional costs incurred by homeowners, commercial property owners and towns/municipalities that are reimbursed by the potentially responsible parties. Key assumptions involve the typical quickest turnaround time provided by the onsite and offsite laboratories. Costs for the operation of a wastewater treatment system and the remediation of a site area or property were provided by personnel who have been involved in the operation of a large FUSRAP site in New Jersey for many years. This study provides valuable information for determining the most cost-effective approach for analysis of project samples and therefore may be used on upcoming FUSRAP projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spacecraft Water Exposure Guidelines For Selected Contaminants

Construction of the International Space Station (ISS)a multinational effort began in 1999. In its present configuration, the ISS is expected to carry a crew of three to six astronauts for up to 180 days (d). Because the space station is a closed and complex environment, some contamination of its internal atmosphere and water system is unavoidable. Several hundred chemical contaminants are likely to be found in the closed-loop atmosphere and recycled water of the ISS. To protect space crews from contaminants in potable and hygiene water, the National Aeronautics and Space Administration (NASA) requested that the National Research Council (NRC) provide guidance on how to develop water exposure guidelines and subsequently review NASA's development of the exposure guidelines for specific chemicals.

Water↗

Effect of Iron Contamination and Polysilicon Gettering on the Performance of Polysilicon‐Based Passivating Contact Solar Cells

Over the past decade, silicon solar cells with carrier-selective passivating contacts based on polysilicon capping an ultra-thin silicon oxide (commonly known as TOPCon or POLO) have demonstrated promising efficiency potentials and are regarded as an evolutionary upgrade to the PERC (passivated emitter and rear contact) cells in manufacturing. The polysilicon-based passivating contacts also exhibit excellent gettering effects that relax the wafer and cleanroom requirements to some extent. Here, in this work, we experimentally explore the impact of bulk iron contamination and polysilicon gettering on the passivation quality of the polysilicon/oxide structure and the resulting solar cells performance. Results show that both n- and p-type polysilicon/oxide passivating contacts are not affected by iron gettering, demonstrating robust and stable passivation quality. However, for a very high bulk iron contamination (1 × 10 13 cm −3 ), the accumulated iron in the p-type lightly boron-doped emitter in crystalline silicon would degrade the emitter saturation current density. This can cause a reduction in both open-circuit voltage and short-circuit current. Meanwhile, this very high iron content (1 × 10 13 cm −3 ) can further degrade the fill factor and temperature coefficient of the cells. On the other hand, for an initial iron content of 2 × 10 12 cm −3 , which should be well above the iron level in the current industrial Czochralski silicon wafers, the resulting cells demonstrate similar performance as the control group with no intentional iron contamination. This work brings attention to both the benefits of polysilicon gettering effects as well as the potential degradation due to the accumulation of metal impurities in the p-type emitter region.

14 SOLAR ENERGY↗

Quantifying spatiotemporal variability in occupant exposure to an indoor airborne contaminant with an uncertain source location

Well-mixed zone models are often employed to compute indoor air quality and occupant exposures. While effective, a potential downside to assuming instantaneous, perfect mixing is underpredicting exposures to high intermittent concentrations within a room. When such cases are of concern, more spatially resolved models, like computational-fluid dynamics methods, are used for some or all of the zones. But, these models have higher computational costs and require more input information. A preferred compromise would be to continue with a multi-zone modeling approach for all rooms, but with a better assessment of the spatial variability within a room. Here to do so, we present a quantitative method for estimating a room's spatiotemporal variability, based on influential room parameters. Our proposed method disaggregates variability into the variability in a room's average concentration, and the spatial variability within the room relative to that average. This enables a detailed assessment of how variability in particular room parameters impacts the uncertain occupant exposures. To demonstrate the utility of this method, we simulate contaminant dispersion for a variety of possible source locations. We compute breathing-zone exposure during the releasing (source is active) and decaying (source is removed) periods. Using CFD methods, we found after a 30 minutes release the average standard deviation in the spatial distribution of exposure was approximately 28% of the source average exposure, whereas variability in the different average exposures was lower, only 10% of the total average. We also find that although uncertainty in the source location leads to variability in the average magnitude of transient exposure, it does not have a particularly large influence on the spatial distribution during the decaying period, or on the average contaminant removal rate. By systematically characterizing a room's average concentration, its variability, and the spatial variability within the room important insights can be gained as to how much uncertainty is introduced into occupant exposure predictions by assuming a uniform in-room contaminant concentration. We discuss how the results of these characterizations can improve our understanding of the uncertainty in occupant exposures relative to well-mixed models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗