Room-temperature quantum-dot-like luminescence from site-controlled InGaN quantum disks
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Providing room comfort quickly by using less energy in cooling systems is important both in terms of efficiency and environment. In this study, independent temperature/humidity control strategies are designed for precooled desiccant based evaporative cooling system to provide room comfort quickly with less energy. Therefore, the speed controls of the system's actuators become important depending on the room, cooler and atmosphere conditions. The mathematical models are obtained to determine the relation between voltages of actuators and the variations in the room's temperature and humidity. After that, new control strategies are developed based on Proportional and Fuzzy+Proportional techniques and the control performance is increased by adding extra modes to the operation of the actuators. The effects of the control techniques on the cooling performance and energy consumption were investigated for different cases. It has been observed that the room temperature and relative humidity reach the set values in a short time for both techniques and are successfully kept at these values under the disturbances. By using Fuzzy+Proportional controller, the robustness of the cooler increases due to more precisely adjustment of controller's parameter depending the system conditions. Finally, both control strategies provide more than 20% energy savings compared to the traditional ON/OFF control.
Controllable manipulation for electrical transport in manganite-based heterojunctions have been desired and studied all the time due to their promising applications in electronic and spintronic devices. We report heterojunctions composed by n-type La{sub 0.9}Hf{sub 0.1}MnO{sub 3} and p-type Si with a SrTiO{sub 3} interlayer. The junctions reveal the formation of n-i-p junction in a wide temperature range of 20–300 K. Under illumination of 630 nm light, remarkable photocurrent has been observed. The photosensitivity (I{sub S}), defined as the ratio of photocurrent to dark current, reaches over 1200% under −3 V bias and illumination of red light with 10 mW cm{sup −2} at room temperature. Even light power density is as low as 0.2 mW cm{sup −2}, I{sub S} is still over 200% under −1.5 V bias. The injection of photo-carriers could be responsible for the observed phenomenon. Such manipulative features by light illumination and bias should be of great potential for functional light sensors.
FY 2022 Q1 deliverables include the development of an emulator that can evaluate the sensor impacts at different sensor locations (i.e., thermostat locations) in a multizone office building. This report presents the detailed procedure of developing the emulator and using the emulator for preliminary sensor impact analysis. In designing new multizone buildings or retrofitting existing buildings, the room thermostat locations or subzoning design has been often determined by best practices without considering the effects of this design in terms of energy or thermal comfort. In subzoning design, the total number of thermostats is usually smaller than the total number of rooms. As a result, one thermostat in one room often controls the indoor temperature of several other adjacent rooms. For example, five zones might share one thermostat located in one of the zones. Because the demands for thermal load in different zones could be different for the multizone buildings, this subzoning design can compromise control performance and waste building energy consumption. Furthermore, for multizone buildings, subzoning could introduce thermal discomfort for zones. This issue has not be thoroughly investigated in simulation/field studies, and the US Department of Energy’s Oak Ridge National Laboratory explored the impacts of subzoning design through modeling and experimental study.
Abstract not provided
This report documents a demonstration of the energy-efficiency improvement provided by a new control system for computer room air handling devices. It also analyzes measured and reported air handling device fan power associated with changing the fan type. A 135,000 square foot commercial data center was used for the demonstration. All air handling units were upgraded with improved efficiency fans, and a control system that automatically adjusts the fan speed for the air handling units was added. Power measurements were collected for a baseline and for a period with the fan speed control system active. Changing the fan type resulted in a savings of 47 percent of energy used by the air handling equipment and associated chiller plant energy needed to cool the air handlers themselves. The addition of the fan speed control resulted in an additional 37 percent savings in the same two categories. The combined savings for the two improvements for the same categories was 66 percent compared to the data center fitted with the original fans without a control system. The energy use reduction provided by the complete air handling device improvement program for the whole data center site is estimated to be 2.9 million kilowatt hours per year—an overall data center site savings of 8.0 percent. The reduced electrical energy use at the site provides a 1.9 million pound yearly reduction of carbon dioxide emissions. This demonstration showed that fan upgrades and a control system addition provide cost-effective improvements for data centers, with a payback reported to be under two years without utility incentives. In addition to the control system providing energy savings, the data collection and visual analysis capabilities provided immediate and long-term benefits. It is recommended that data center operators consider investing in fan upgrades and/or adding fan speed control for computer room air handlers.
Purpose: Precision delivery of radiation dose relies on accurate knowledge of the machine isocenter under a variety of machine motions. This is typically determined by performing a Winston-Lutz test consisting of imaging a known object at multiple gantry/collimator/table angles and ensuring that the maximum offset is within specified tolerance. The first step in the Winston-Lutz test is careful placement of a ball bearing at the machine isocenter as determined by repeated imaging and shifting until accurate placement has been determined. Conventionally this is performed by adjusting a stage manually using vernier scales which carry the limitation that each adjustment must be done inside the treatment room with the risks of inaccurate adjustment of the scale and physical bumping of the table. It is proposed to use a motorized system controlled outside of the room to improve the required time and accuracy of these tests. Methods: The three dimensional vernier scales are replaced by three motors with accuracy of 1 micron and a range of 25.4mm connected via USB to a computer in the control room. Software is designed which automatically detects the motors and assigns them to proper axes and allows for small shifts to be entered and performed. Input values match calculated offsets in magnitude and sign to reduce conversion errors. Speed of setup, number of iterations to setup, and accuracy of final placement are assessed. Results: Automatic BB placement required 2.25 iterations and 13 minutes on average while manual placement required 3.76 iterations and 37.5 minutes. The average final XYZ offsets is 0.02cm, 0.01cm, 0.04cm for automatic setup and 0.04cm, 0.02cm, 0.04cm for manual setup. Conclusion: Automatic placement decreased time and repeat iterations for setup while improving placement accuracy. Automatic placement greatly reduces the time required to perform QA.
Complex-oxide heterostructures exhibit rich physical behavior such as emergent conductivity, superconductivity, and magnetism that are intriguing for scientific reasons as well as for potential technological applications. It was recently discovered that in-plane magnetism at the LaAlO{sub 3}/SrTiO{sub 3} (LAO/STO) interface can be electronically controlled at room temperature. Here, we employ magnetic force microscopy to investigate electronically controlled ferromagnetism at the LAO/STO interface with LAO thickness t varied from 4 unit cell (u.c.) to 40 u.c. Magnetic signatures are observed only within a thickness window 8 u.c. ≤ t ≤ 25 u.c. Within this window, the device capacitance corresponds well to the expected geometric value, while for thicknesses outside this window, the capacitance is strongly suppressed. The ability to modulate electronic and magnetic properties of LAO/STO devices depends on the ability to control carrier density, which is in turn constrained by intrinsic tunneling mechanisms.
Life extension beyond 60 years for the U.S operating nuclear fleet requires that instrumentation and control (I&C) systems be upgraded to address aging and reliability concerns. It is impractical for the legacy systems based on 1970’s vintage technology operate over this extended time period. Indeed, utilities have successfully engaged in such replacements when dictated by these operational concerns. However, the replacements have been approached in a like-for-like manner, meaning that they do not take advantage of the inherent capabilities of digital technology to improve business functions. And so, the improvement in I&C system performance has not translated to bottom-line performance improvement for the fleet. Therefore, wide-scale modernization of the legacy I&C systems could prove to be cost-prohibitive unless the technology is implemented in a manner to enable significant business innovation as a means of off-setting the cost of upgrades.
The Light Water Reactor Sustainability (LWRS) Program, which is sponsored by the United States (U.S.) Department of Energy (DOE), conducts research and development (R&D) to establish the technical bases to sustain U.S. nuclear assets. One area in the LWRS program is the Plant Modernization pathway, which includes human factors R&D, human factors engineering (HFE), and ergonomics. LWRS program researchers in this pathway conduct targeted R&D to address aging and reliability concerns with the legacy instrumentation and control (I&C) and related information systems in commercial nuclear power plants (NPPs). One key aspect of this pathway is to develop a strategy for full nuclear plant modernization, which previous LWRS plant modernization milestone reports have begun to describe. To further support this comprehensive plan and vision for full plant modernization, additional details need to be further developed. In particular, a core aspect of a strategy for full nuclear plant modernization is an HFE program plan and an end state vision for plant modernization that is well-integrated with both 1) a technically defensible approach to migrating the existing, mostly analog I&C infrastructure to a digital I&C infrastructure, and 2) a valid business case methodology to cost-justify the modernization activity. Thus, the purpose of this LWRS R&D activity and milestone report is threefold. First, the report provides guidance for operating commercial NPPs to support their development and evaluation of an HFE program management plan (HFE PMP) and an end state vision for plant modernization. The report presents best practices and lessons learned related to HFE PMPs based on MCR modifications in which analog systems were replaced by digital I&C systems. Second, the report summarizes the rationale for full digital I&C integration, highlights a number of factors that are critical to consider, and describes how HFE should merge with full digital I&C integration. Finally, the report summarizes and integrates the economic factors that must be considered to cost-justify HFE involvement in plant modernization.
This report describes an external review conducted by the Light Water Reactor Sustainability Program Plant Modernization Pathway (referred to as Pathway) to solicit feedback on the topics and results of the ongoing Instrumentation and Control (I&C) research program. This review was held in conjunction with the Nuclear Energy Institute (NEI) Digital I&C Working Group meeting that was held at Idaho National Laboratory on October 16–17, 2018. Members of the Nuclear Regulatory Commission (NRC) staff working on digital I&C issues through their Integrated Action Plan also attended. The NEI and NRC agreed that the meeting participants would serve as an external review panel for the purpose of obtaining expert input on the value and timing of the research projects. Five major research areas were presented, along with demonstrations of new technologies in the Human Systems Simulation Laboratory and the Computer-Assisted Virtual Environment. Following the presentations, the external review was conducted by referring to a set of summary slides of the five research areas, and allowing each participant to enter ratings and comments on a survey form as each area was addressed. Fourteen forms were returned. These feedback forms were analyzed by the Pathway who compiled and responded to the data and comments, which are documented in this report. The participants also had opportunity to provide comments on the LWRS Program as a whole and to suggest additional research topics of value. The feedback provided by the external review participants is taken to be a strong endorsement of the types of projects being conducted by the Pathway, the value they hold for the operating nuclear plants, and the general timing of need. The feedback aligns well with the priorities, levels of efforts allocated for the research projects, and project schedules of the current Pathway research program. The feedback also provides realistic observations on the practicality of some aspects of implementing these technologies. The Pathway will consider all of the feedback and address the recommended research topics that have been identified by the external review participants. Pathway research plans will be adjusted as warranted.
Commercial nuclear power plants (NPPs) provide emission free, always-on electricity that must be part of the energy mix if U.S. industry and business are to remain competitive while enjoying the benefits of a clean environment. Most U.S. NPPs in operation today were licensed using state-of-the-art analog technology of the 1970’s. While these systems are well proven and designed with multiple redundant channels, they required extensive manual surveillance and testing procedures to demonstrate their continued functioning. All of this adds up to increasing labor costs as the only means to increase plant availability. The United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program is performing a study to determine how an NPP can fully modernize, improve safety, and improve efficiency enough to make nuclear power competitive with current and future market conditions. The study is a process improvement analysis whereby current operational processes are evaluated to identify where efficiencies and cost-savings can be realized. This report will describe a process that will provide each utility with the tools to evaluate their present state, set goals for where they want to be regarding Operation and Maintenance (O&M) costs, while offering transformative pathways to achieve these improvements. The transformative changes will be divided into 1) work process improvements, 2) technology solutions, and 3) regulatory reform. By applying these pathways in combination, NPPs can achieve the dramatic O&M savings needed to sustain safe and economic operation into the future.
Modern digital instrumentation and control (I and C) systems offer nearly unlimited functional capability. However, the complexity of their design (including their system software and application software) is significantly higher than that of conventional, hardwired systems, to the point that it is generally impossible to demonstrate that there are no residual design errors, even when the best development and verification techniques have been applied. When activated by specific conditions, design errors could result in systematic failures, i.e., failures that occur deterministically each time and wherever an activating condition is present. Redundancy could be defeated when the same design error affects multiple channels or systems, and the activating condition affects several of these channels or systems. In the case of safety I and C systems, most of the functions are poised protection functions that must be actuated when and only when a demand situation occurs in the plant. In nuclear power plants, the most dangerous failure mode for such functions generally is failure to actuate, and many measures are taken to protect from such failure mode. This paper considers the other failure modes of safety I and C functions, and also the failure modes of the other I and C functions that are less important to safety. It is not limited to poised functions, and considers other types of functions such as regulation functions or human interface functions. It proposes a framework for analyzing and providing defense against spurious actuations and other incorrect behaviors from digital I and C systems directly interacting with the plant process or with operators: these might be useful for example to justify that design bases for reactor protection are adequate, or to ensure plant performance and availability. (authors)
Strongly correlated kagome magnets are promising candidates for achieving controllable topological devices owing to the rich interplay between inherent Dirac fermions and correlation-driven magnetism. Here we report tunable local magnetism and its intriguing control of topological electronic response near room temperature in the kagome magnet Fe 3 Sn 2 using small angle neutron scattering, muon spin rotation, and magnetoresistivity measurement techniques. The average bulk spin direction and magnetic domain texture can be tuned effectively by small magnetic fields. Magnetoresistivity, in response, exhibits a measurable degree of anisotropic weak localization behavior, which allows the direct control of Dirac fermions with strong electron correlations. Furthermore, our work points to a novel platform for manipulating emergent phenomena in strongly correlated topological materials relevant to future applications.
TR-55 rubber specimens were previously subjected to an aging process consisting of the application of a tensile strain of approximately 67%, 100%, 133%, or 167% elongation for 4, 8, 12, or 16 h at either 250 C or room temperature. Control specimens at the same temperatures/durations were not subjected to tensile strain. The specimens were allowed to recover at room temperature without external stimuli for over 100 days before tensile testing. A single dog bone was cut from each specimen and a stress-strain curve was obtained. The elastic modulus of each specimen was calculated. Specimens aged under tensile strain exhibited rubber-like behavior dependent on the aging elongation and duration. This behavior was not evident in the unstrained controls. For the unstrained controls, exposure to 250 C resulted in an increase in modulus relative to the unheated material independent of the heating duration. The tensile strain applied during the aging process caused a reduction in modulus relative to the controls; lower moduli were observed for the shorter aging durations. Slippage of the specimens in the grips prevented determination of ultimate strength, as all specimens either slipped completely out of the grip before failure or failed at the original grip edge after slipping.
Constellation Energy and the United States Department of Energy (DOE) have established a public/private partnership to implement a pilot digital upgrade to replace legacy analog, safety-related reactor protection and emergency safety feature actuation systems (RPS/ESFAS) with modern digital systems. This effort is occurring at Constellation’s Limerick Generating Station. This project is being performed in accordance with industry processes that have been adapted to better support digital upgrades. These processes include IP-ENG-001, Standard Design Process, NISP-EN-04, Standard Digital Engineering Process and Electric Power Research Institute Report 3002011816, Digital Engineering Guide. The Light Water Reactor Sustainability (LWRS) Program at the Idaho National Laboratory (INL) has been supporting this effort. Latest INL HFE efforts in support of this project have focused on definition and implementation of the Human Factors Engineering (HFE) Program in support of Constellation design and related licensing efforts. This paper presents the development execution of the HFE Program through completion of the Planning and Analysis Phase as defined by NUREG-0711 as well as HFE lessons learned.
Two-dimensional (2D) van der Waals ferroelectrics provide an unprecedented architectural freedom for the creation of artificial multiferroics and nonvolatile electronic devices based on vertical and coplanar heterojunctions of 2D ferroic materials. Nevertheless, controlled microscopic manipulation of ferroelectric domains is still rare in monolayer-thick 2D ferroelectrics with in-plane polarization. Here we report the discovery of robust ferroelectricity with a critical temperature close to 400 K in SnSe monolayer plates grown on graphene and the demonstration of controlled room-temperature ferroelectric domain manipulation by applying appropriate bias voltage pulses to the tip of a scanning tunneling microscope (STM). This study shows that STM is a powerful tool for detecting and manipulating the microscopic domain structures in 2D ferroelectric monolayers, which are difficult for conventional approaches such as piezoresponse force microscopy, thus facilitating the hunt for other 2D ferroelectric monolayers with in-plane polarization with important technological applications.
Locally networked or remotely controlled home automation system becomes a popular paradigm because of the numerous advantages and is suitable for academic research. This paper proposes a method for an implementation of Raspberry Pi based home automation system presented with an android phone access interface. The power consumption profile across the connected load is measured accurately through programming. Users can access the graph of total power consumption with respect to time worldwide using their Dropbox account. An android application has been developed to channelize the monitoring and controlling operation of home appliances remotely. This application facilitates controlling of operating pins of Raspberry Pi by pressing the corresponding key for turning “on” and “off” of any desired appliance. Systems can range from the simple room lighting control to smart microcontroller based hybrid systems incorporating several other additional features. Smart home automation systems are being adopted to achieve flexibility, scalability, security in the sense of data protection through the cloud-based data storage protocol, reliability, energy efficiency, etc.