Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Systems Cyber Security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Architecture and Methods for Substation SCADA Cybersecurity: Best Practices

There are over 3000 electricity providers in the United States, encompassing investor and publicly owned utilities as well as electric cooperatives. There has been ongoing trends to increasingly automate and provide remote control and monitoring of electric energy delivery systems. The deployment of computer network technologies has increased the efficiency and reliability of electric power infrastructure. However, the increased use of digital communications has also increased the vulnerability to malicious cyber attacks [1]. In 2004 the National Research Councils (National Academies) formed a committee of specialists to address these vulnerabilities and propose possible solutions with an objective to prioritize the R&D needs for developing countermeasures. The committee addressed many potential concerns in the electric power delivery system and classified them based upon different criteria and presented recommendations to minimize the gap between the academic research directions and the needs of the electric utility industry. The complexity and diversity of the electric power delivery system in the U.S. has opened many ports for attackers and intruders [1]. This complexity and diversity is attributed to the fact that power delivery system is a network of substations, transmission and distribution lines, sub-networks of controlling, sensing and monitoring units, and human operator involvement for running the system [1]. Accordingly, any incident such as the occurrence of a fault or disturbance in this complex network cannot be deferred and should be resolved within an order of milliseconds, otherwise there is risk of large-scale outages similar to the occurrences in India and the U.S. in 2003 [2]. There are three main vulnerabilities in supervisory control and data acquisition (SCADA) systems commonly identified—physical vulnerability, cyber vulnerability and personal vulnerability [1]. In terms of cyber threats, SCADA systems are the most critical elements in the electric power grid in the U.S. Unauthorized access to a SCADA system could enable/disable unexpected equipment (such as disable the protection system or a circuit breaker) which could cause large scale disruptions of electric power delivery. This paper provides an overview of power system SCADA technologies in transmission substations (Section 2) and summarizes the best practices for implementing a cyber security program. After introducing SCADA system operations in Section 2, a description of the security challenges for SCADA systems is presented in Section 3. In Section 4, NECRC Critical Infrastructure Protection standards CIP-002 through CIP-009 are summarized. An overview of industry best practices is presented in Section 5.

97 MATHEMATICS AND COMPUTING↗

Network Slicing for Federated Learning in Operational Technology Environment

Industrial Control Systems (ICS) and Supervisory Control and Data Acquisition (SCADA) environments are essential to modern infrastructure, facing challenges in ensuring low-latency, high-throughput communication while mitigating cyber threats. This paper presents a framework integrating Federated Learning (FL) and network slicing with Quality of Service (QoS) to enable real-time monitoring without disrupting OT operations. Leveraging digital twin technology and Network Function Virtualization (NFV), the architecture supports predictive analytics and Industry 4.0 requirements. FL facilitates decentralized model training, preserving data privacy and scalability, though it introduces potential throughput constraints. Network slicing addresses this by creating dedicated virtualized segments optimized for performance and security. Advanced fault tolerance at the container and instance levels enhances system reliability. The proposed architecture ensures high throughput, low latency, and secure orchestration for real-time anomaly detection in OT networks. Performance evaluations validate its efficiency in throughput, deployment, and learning accuracy, providing a robust foundation for future ICS automation and data-driven decision-making.

Delgado, Brian G. Rodiles [University of Texas at ↗

Software Quality Assurance Plan for the Geochemist’s Workbench®

The Geochemist’s Workbench® (GWB) Release 10.0.10 is a geochemical modeling suite for simulating the reactive fate and transport of radionuclides and other metals in aqueous systems including groundwater, surface water, soil, and sediment. At the Savannah River National Laboratory, GWB plays an important role in the preparation of Performance Assessments involving cementitious materials. The software classification for GWB is Level “C.” GWB was purchased from Aqueous Solutions LLC and came into existence outside of the Software Quality Assurance procedures; therefore, it is considered “existing/acquired” software. This Software Quality Assurance Plan addresses verification techniques and the required life cycle components for Level “C” existing/acquired software (i.e., “Evaluation,”“Configuration Control,” and “Cyber Security Analysis”) with other elements optionally applied using a graded approach.

58 GEOSCIENCES↗

Parameter Estimation for Decoding Sensor Signals

This paper introduces a parameter estimation approach for decoding digital sensor signals in a cyber-physical system. For unknown or not fully characterized digital sensor data, it can be difficult to decipher a desired signal from background or noise. In a cyber-physical system with networked sensors, we can leverage knowledge of the physical system to inform the decoding of the digital signals. This work in progress is a case study on deciphering commercial vehicle on-board sensor networks that communicate through the Controller Area Network (CAN). By understanding the stock vehicle sensor network, a vehicle can be extended into a scalable research platform with minimal instrumentation. Our challenge was to localize desired sensor signals encoded in network traffic that included other sensor data, control messages, as well as encoding and security overhead. Due to the vehicle’s unknown sensor network, our approach developed methods to efficiently analyze and identify key signals despite the large state-space for potential signal embeddings.

Nice, Matthew↗

Cyber-Physical Risks for Advanced Reactors

Cybersecurity for industrial control systems is an important consideration that advance reactor designers will need to consider. How cyber risk is managed is the subject of on-going research and debate in the nuclear industry. This report seeks to identify potential cyber risks for advance reactors. Identified risks are divided into absorbed risk and licensee managed risk to clearly show how cyber risks for advance reactors can potentially be transferred. Absorbed risks are risks that originate external to the licensee but may unknowingly propagate into the plant. Insights include (1) the need for unification of safety, physical security, and cybersecurity risk assessment frameworks to ensure optimal coordination of risk, (2) a quantitative risk assessment methodology in conjunction with qualitative assessments may be useful in efficiently and sufficiently managing cyber risks, and (3) cyber risk management techniques should align with a risked informed regulatory framework for advance reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Design and Evaluation of Zero Trust Architecture for Electric Vehicle Charging Infrastructure: EVs @ Scale Series on EV Charging Station Cybersecurity

Implementing a zero trust architecture can significantly bolster the security of electric vehicle (EV) charging infrastructure. EV charging infrastructure includes numerous networked interfaces, each of which can present potential vulnerabilities. When these vulnerabilities are exploited, they can compromise the entire system, leading to severe operational and security risks. Zero trust is a security model that operates on the principle of "never trust, always verify," which helps manage the attack surface and limit the scope of any potential compromises. Fundamentally, this model ensures that no entity, whether inside or outside the network, is trusted by default. The design principles of zero trust include continuous verification, strict deny-by-default access controls, and micro-segmentation. Continuous verification ensures that every request is thoroughly checked, regardless of its origin. Strict access controls enforce the principle of least privilege, allowing users and devices only the minimum necessary access to perform their functions. Micro-segmentation involves dividing the network into smaller, isolated segments to prevent lateral movement in case of a breach. In the context of EV charging infrastructure, zero trust can be implemented through various strategies. For example, multi-factor authentication (MFA) can be required for engineers to access the management interfaces and control systems of charging stations. Real-time monitoring and analysis of network traffic can help detect and respond to anomalies. Systems that do not need to communicate with each other can be micro-segmented to enhance security. All communications should adhere to predefined policies to be permitted. Additionally, encrypting communications can protect sensitive information exchanged between chargers and management systems. This paper presents a zero trust architecture specifically designed for EV charging infrastructure. Implementing zero trust not only mitigates risks but also builds a resilient infrastructure capable of withstanding and quickly recovering from cyber threats. The architecture addresses six defined security objectives. A comprehensive test plan is developed to assess the architecture against these objectives, and the results of the evaluation are reported. This approach is essential for maintaining the reliability and integrity of EV charging services in an increasingly interconnected and vulnerable digital landscape. This is the first in a planned series of papers exploring the implementation of zero trust in EV charging infrastructure. Each paper will delve into different aspects and applications of zero trust, highlighting how various work processes and requirements can lead to distinct architectural designs. These architectures will be tailored to address specific security challenges and operational needs within the EV charging ecosystem, ensuring a robust and adaptable security framework.

33 ADVANCED PROPULSION SYSTEMS↗

Hiding Critical Targets in Smart Grid Networks

With the integration of advanced communication technologies, the power grid is expected to greatly enhance efficiency and reliability of future power systems. However, since most electrical devices in power grid substations are connected via communication networks, cyber security of these communication networks becomes a critical issue. Real-World incidents such as Stuxnet have shown the feasibility of compromising a device in the power grid network to further launch more sophisticated attacks. To deal with security attacks of this spirit, this paper aims to hide critical targets from compromised internal nodes and hence protect them from further attacks launched by those compromised nodes. In particular, we consider substation networks and propose to add carefully-controlled dummy traffic to a substation network to make critical target nodes indistinguishable from other nodes in network traffic patterns. This paper describes the design and evaluation of such a scheme. Evaluations show that the scheme can effectively protect critical nodes with acceptable communication cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Autonomous Inverter Controls for Resilient and Secure Grid Operation: Vector Control Design for Grid Forming

The project addresses both fundamental and practical challenges of GFM/GFL inverter control for the power grids with high inverter based resources (IBRs) penetration. A data- driven modeling technique is applied to accurately model dynamics of PWM inverters, including electromagnetic-transient (EMT). Systematic and integrative designs of grid- forming (GFM) and grid-following (GFL) primary controls are developed to guarantee system performance under either normal or abnormal operating conditions without violating constraints. This modeling and control framework provides black-start capability in case of an outage without relying on rotating generators, and its secondary control is also shown to enhance resilience against cyber-physical attacks.

14 SOLAR ENERGY↗

An Approach for Assessing Consequences of Potential Supply Chain and Insider Contributed Cyber Attacks on Nuclear Power Plants

The Stuxnet attack at the Natanz facility is an example of a targeted and successful cyber attack on a nuclear facility. Snowden's release of National Security Agency documents demonstrated the consequences of the insider threat. More recently, the United States tried to attack North Korea but failed, South Korea was attempting to attack North Korea, and both applied Stuxnet-like approaches. These sophisticated targeted attacks differ from web-site hacking events that are reported almost daily in the news mainly because targeted attacks require detailed design and operation information of the systems attacked and/or are often carried out by insiders. For instance, in order to minimize disruption of facilities around the world, Stuxnet remained idle until it recognized the specific configuration of the Natanz facility, demonstrating that the attackers possessed extremely detailed information about the facility. Such targeted cyber attacks could become a national-level military weapon and be used in coercion of hostile countries. While U.S. nuclear power plants (NPPs) are well designed and protected and not easily attacked through internet hacking, there have been a few digital-system-related incidents. For example, in 2003, the Slammer worm breached the private network of the Davis Besse plant and disabled a safety monitoring system for almost five hours. The breach did not pose a safety hazard because the plant was offline, but it demonstrates the vulnerability of NPP systems. The worm did not enter the plant systems directly; it began by entering the systems of a Davis Besse contractor, and entered through the T1 line bridging the contractor's computer and Davis Besse's corporate networks. The T1 line was not protected by the plant's firewall. The success of the Stuxnet-Natanz case demonstrates that supply-chain level attack (i.e., physically tampering with digital systems to install undetectable malware for the purpose of bringing harm to a player further down the supply chain network) plays a crucial role in a successful attack. Although attacking an NPP naturally requires more complex strategies and tactics than internet hacking, NPP's have a variety of sophisticated and possibly sensitive systems that may be attacked. Previous studies, for example, Baylon, have identified and confirmed that such attack strategies and tactics can be designed and could produce severe damage to an NPP. Current NPPs were designed according to design basis accidents that predate use of the internet by the general public and did not take into consideration potential cyber attacks that could be carried out by state-sponsored attackers and malicious insiders. To date, no detailed engineering analysis has been performed to realistically examine the consequences these attacks may have on the plants. In this paper, we discuss an approach for assessing the potential consequences of Stuxnet type of attacks. We will examine the engineering criteria used in designing the plants, develop possible attack scenarios in terms of the structures, components, and systems (SSCs) being controlled by digital systems at the NPPs, perform engineering analysis to determine if the attacks would impose conditions that are beyond design bases, and categorize the consequences of the potential accidents. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamic Analysis of Mobile Device Applications

The On-Device Dynamic Analysis of Mobile Applications (ODAMA) project was started in an effort to protect mobile devices used in Industrial Control Systems (ICS) from cyber-attack. Because mobile devices hide as much of the “computer” as possible, the user’s ability to assess the software running on their system is limited. The research team chose Google’s Android platform for this initial research because it is open source and it would give us freedom in our approach, including the ability to modify the mobile device’s operating system itself. The research team concluded that a Privileged Application was the right approach, and the result was ODAMA. This project is an important piece of the work to secure the expanding use of mobile devices with our nation’s critical infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Laboratory-Directed Research and Development 2016 Summary Annual Report

The Laboratory-Directed Research and Development (LDRD) Program at Idaho National Laboratory (INL) reports its status to the U.S. Department of Energy (DOE) by March of each year. The program operates under the authority of DOE Order 413.2C, “Laboratory Directed Research and Development” (April 19, 2006), which establishes DOE’s requirements for the program while providing the laboratory director broad flexibility for program implementation. LDRD funds are obtained through a charge to all INL programs. This report includes summaries of all INL LDRD research activities supported during Fiscal Year (FY) 2016. INL is the lead laboratory for the DOE Office of Nuclear Energy (DOE-NE). The INL mission is to discover, demonstrate, and secure innovative nuclear energy solutions, other clean energy options, and critical infrastructure with a vision to change the world’s energy future and secure our critical infrastructure. Operating since 1949, INL is the nation’s leading research, development, and demonstration center for nuclear energy, including nuclear nonproliferation and physical and cyber-based protection of energy systems and critical infrastructure, as well as integrated energy systems research, development, demonstration, and deployment. INL has been managed and operated by Battelle Energy Alliance, LLC (a wholly owned company of Battelle) for DOE since 2005. Battelle Energy Alliance, LLC, is a partnership between Battelle, BWX Technologies, Inc., AECOM, the Electric Power Research Institute, the National University Consortium (Massachusetts Institute of Technology, Ohio State University, North Carolina State University, University of New Mexico, and Oregon State University), and the Idaho university collaborators (i.e., University of Idaho, Idaho State University, and Boise State University). Since its creation, INL’s research and development (R&D) portfolio has broadened with targeted programs supporting national missions to advance nuclear energy, enable clean energy deployment, and secure and modernize critical infrastructure. INL’s research, development, and demonstration capabilities, its resources, and its unique geography enable integration of scientific discovery, innovation, engineering, operations, and controls into complex large-scale testbeds for discovery, innovation, and demonstration of transformational clean energy and security concepts. These attributes strengthen INL’s leadership as a demonstration laboratory. As a national resource, INL also applies its capabilities and skills to the specific needs of other federal agencies and customers through DOE’s Strategic Partnership Program.

99 GENERAL AND MISCELLANEOUS↗

Evaluating Security Controls Based on Key Performance Indicators and Stakeholder Mission

Good security metrics are required to make good decisions about how to design security countermeasures, to choose between alternative security architectures, and to improve security during operations. Therefore, in essence, measurement can be viewed as a decision aid. The lack of sound practical security metrics is severely hampering progress in the development of secure systems. The Cyberspace Security Econometrics System (CSES) offers the following advantages over traditional measurement systems: (1) CSES reflects the variances that exist amongst different stakeholders of the same system. Different stakeholders will typically attach different stakes to the same requirement or service (e.g., a service may be provided by an information technology system or process control system, etc.). (2) For a given stakeholder, CSES reflects the variance that may exist among the stakes she/he attaches to meeting each requirement. The same stakeholder may attach different stakes to satisfying different requirements within the overall system specification. (3) For a given compound specification (e.g., combination(s) of commercial off the shelf software and/or hardware), CSES reflects the variance that may exist amongst the levels of verification and validation (i.e., certification) performed on components of the specification. The certification activity may produce higher levels of assurance across different components of the specification than others. Consequently, this paper introduces the basis, objectives and capabilities for the CSES including inputs/outputs and the basic structural and mathematical underpinnings.

97 MATHEMATICS AND COMPUTING↗

Cyber-Resilient Frequency Control of Power Grids with Energy Storage Systems

The integration of synchronous generators and energy storage systems operated through communication networks introduces new challenges and vulnerabilities to the electric grid, where cyber attacks can corrupt sensor measurements or control inputs and interrupt functions such as frequency regulation. This paper proposes a defense methodology for the design of resilient operating constraints imposed on each generation and storage unit in order to prevent any attack sequence from driving the system's frequency to unsafe conditions. The resilient operating constraints are found by using ellipsoidal approximations of the reachable set of the power system, leading to a convex optimization problem with linear matrix inequalities. Numerical results in a single-area power system with synchronous generation and energy storage demonstrate how the resilient constraints provide security guarantees against any type of attack affecting frequency measurements or controller setpoints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An integrated security framework for GOSS power grid analytics platform

In power grid operations, security is an essential component for any middleware platform. Security protects data against unwanted access as well as cyber attacks. GridOpticsTM Software System (GOSS) is an open source power grid analytics platform that facilitates ease of access between applications and data sources and promotes development of advanced analytical applications. GOSS contains an API that abstracts many of the difficulties in connecting to various heterogeneous data sources. A number of applications and data sources have already been implemented to demonstrate functionality and ease of use. A security framework has been implemented which leverages widely accepted, robust JavaTM security tools in a way such that they can be interchanged as needed. This framework supports the complex fine-grained, access control rules identified for the diverse data sources already in GOSS. Performance and reliability are also important considerations in any power grid architecture. An evaluation is done to determine the overhead cost caused by security within GOSS and ensure minimal impact to performance.

Gibson, Tara D.↗

Multi-layered Resilient Microgrid Networks

Distribution grid resilience, especially when the grid is under high penetration of Distributed Energy Resources (DER), e.g. PV and energy storage, is essential to ensure the quality of electric power services. The resiliency aspect is particularly important for critical loads that typically include hospitals, police/fire stations, and national security facilities. Networks of multiple interconnected reconfigurable microgrids help to increase renewable energy penetration and may be used as basic building blocks for implementing future resilient power grids. However, this integration requires additional layers of communications, both horizontal and vertical, which may substantially increase the potential cyber attack surfaces as well as escalate risks for wide-spread malfunctions of automation systems. The Mulit-layered Resilient Microgrid Networks project is an industry-academic collaboration between ABB, Duke Energy and the University of Illinois at Urbana-Champaign (UIUC) that has developed and demonstrated a cyber-physical resilient control and communication architecture for deployment of multiple microgrid networks, as well as retrofitting the existing distribution grids by increasing DER penetration levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Guided Resilience Self Assessment Application

Reliable electricity access is vital for everything from hospitals to national security. When grid disturbances occur, it is crucial to minimize the amount of time it takes to recover. Grid resiliency considers both the preparation for and recovery from high-impact low-frequency disturbances (HILF) such as weather events and cyber attacks. The Department of Energy (DOE) Wind Energy Technologies Office (WETO) funds the multi-laboratory Microgrids, Infrastructure Resilience, and Advanced Control Launchpad (MIRACL) project to investigate technologies to support and grow distributed wind. Researchers at Idaho National Laboratory (INL) contribute to resilience and cybersecurity efforts for the project, and have produced a resilience framework to evaluate system resilience based on individual system specifications. In order to make this framework easy for anyone to apply, I have coded a web application that allows users to input their power system qualities, goals, and perceived risks and then receive suggestions on how to improve their grid resiliency. The web application follows the seven steps in the planning stage of the framework process, allowing the user to input information about their grid and select from common goals, metrics, and hazards, as well as add their own. The application currently provides information about how to complete each step, requiring minimal prior knowledge of the framework. Future work for this application will include allowing the user to submit line drawings of their system and incorporate modeling tools so that the hazard simulations of applying the framework is completed for the user.

97 MATHEMATICS AND COMPUTING↗

Cybersecurity for the Operational Technology Environment (CyOTE) (Final Technical Report)

Electric grids have historically been susceptible to both physical attacks and environmental hazards but the implementation of smart grids, remote management, and self-healing networks, has now made the grid vulnerable to cyber attacks. To address risks introduced by routable connectivity, utilities must establish dynamic solutions to identify, protect, detect, respond to, and recover from cyber security threats and vulnerabilities. In response to the evolving threat landscape U.S. Department of Energy-Office of Cybersecurity, Energy Security, and Emergency Response (DOE CESER) initiated the Cybersecurity for the OT Environment (CyOTE) pilot program, a U.S. Department of Energy (DOE) effort designed to leverage U.S. intelligence capabilities to prevent, detect, or mitigate a cyber attack on utility operational technology (OT) networks. As part of the CyOTE pilot, The Southern Company (Southern Company or Southern) researched, evaluated and deployed emerging Commercial off the Shelf (COTS) technologies and cyber security monitoring architectures to provide previously unrealized network visibility and situational awareness through deep packet inspection and data analytics. This Final Scientific/Technical Report documents the objectives, methodology, lessons learned, and results of Southern Company’s participation in the CyOTE pilot from December 2018 to September 2023.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comprehensive, Multi-Source Cyber-Security Events Data Set

This data set represents 58 consecutive days of de-identified event data collected from five sources within Los Alamos National Laboratory’s corporate, internal computer network. The data sources include Windows-based authentication events from both individual computers and centralized Active Directory domain controller servers; process start and stop events from individual Windows computers; Domain Name Service (DNS) lookups as collected on internal DNS servers; network flow data as collected on at several key router locations; and a set of well-defined red teaming events that present bad behavior within the 58 days. In total, the data set is approximately 12 gigabytes compressed across the five data elements and presents 1,648,275,307 events in total for 12,425 users, 17,684 computers, and 62,974 processes. Specific users that are well known system related (SYSTEM, Local Service) were not de-identified though any well-known administrators account were still de-identified. In the network flow data, well-known ports (e.g. 80, 443, etc) were not de-identified. All other users, computers, process, ports, times, and other details were de-identified as a unified set across all the data elements (e.g. U1 is the same U1 in all of the data). The specific timeframe used is not disclosed for security purposes. In addition, no data that allows association outside of LANL’s network is included. All data starts with a time epoch of 1 using a time resolution of 1 second. In the authentication data, failed authentication events are only included for users that had a successful authentication event somewhere within the data set.

97 MATHEMATICS AND COMPUTING↗