Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cooling effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Evolution of super-Jupiters

The physics of the interiors of Jovian-class objects is reviewed, and its extension to substellar objects is discussed. Some results are presented for objects cooling from effective temperatures starting at 2500 K. The interior calculations are coupled to model atmosphere surface conditions computed by Lunine; the latter are continued to higher temperatures and pressures in the ideal gas region and are then matched by entropy to the strongly-coupled interior region. Except in the planetary-mass models, this transition region occupies a negligible fraction of the total mass. For the observed parameters of VB8B, only models with masses in excess of 0.05 solar mass have cooling ages above a billion years. Thus, for plausible VB8B lifetimes, this object is likely to be close to the critical hydrogen-ignition mass.

Hubbard, W. B.↗

Measured effects of coolant injection on the performance of a film cooled turbine

Tests have been conducted on a 20-inch diameter single-stage air-cooled turbine designed to evaluate the effects of film cooling air on turbine aerodynamic performance. The present paper reports the results of five test configurations, including two different cooling designs and three combinations of cooled and solid airfoils. A comparison is made of the experimental results with a previously published analytical method of evaluating coolant injection effects on turbine performance.

Mcdonel, J. D.↗

Cosmological Implications of the Uncertainty in Astrochemical Rate Coefficients

The cooling of neutral gas of primordial composition, or with very low levels of metal enrichment, depends crucially on the formation of molecular coolants, such as H2 and HD within the gas. Although the chemical reactions involved in the formation and destruction of these molecules are well known, the same cannot be said for the rate coefficients of these reactions, some of which are uncertain by an order of magnitude. Here we discuss two reactions for which large uncertainties exist the formation of H2 by associative detachment of H- with H and the destruction of H- by mutual neutralization with protons. We show that these uncertainties can have a dramatic impact on the effectiveness of cooling during protogalactic collapse.

Glover, S. C. O.↗

Analysis of Heat Transfer from Local Heating and Cooling Sources at Cryogenic Temperatures

Understanding the dispersion of heat around a cryogenic fluid tank, specifically the interaction between the cryogenic fluid and the tank wall is critical in the analysis of long duration cryogen storage in microgravity. The heat transfer interaction between a cryogenic storage tank and heat sources from external spacecraft structures is also one of the many factors that determine how much heat enters a tank. Recent flight experiments with two-phase fluids have indicated that local concentrations of heat input (also known as “hot spots”) can cause unwanted affects including local boiling. Computational fluid dynamic (CFD) models can provide a detailed assessment of the heat transfer occurring across a cryogenic storage system. However, CFD modeling takes time to construct and run. A simpler approach that can act as initial guidance for later CFD modeling analyzes external “hot spots” as point or finite heat sources. A radial, finite element network or a local direct solution can effectively estimate the heat spread across a cryogenic storage tank by calculating the temperature and heat load as a function of distance from the heat source. This calculation accounts for the convective heat transfer between the cryogenic fluid and storage tank surface. Similar approaches can be used to determine the effectiveness of cooling from a cryocooler as a finite, local heat sink. This approach allows for quick approximations of the thermal map across a cryogenic tank as well as sensitivity analysis under a wide range of design parameters including gravitational fields as implied through natural convection coefficients.

Cryogenic Fluid Management↗

Earth observing scanning polarimeter

Climate forcing by tropospheric aerosols is receiving increased attention because of the realization that the climate effects may be large, while our knowledge of global aerosol characteristics and temporal changes is very poor. Tropospheric aerosols cause a direct radiative forcing due simply to their scattering and absorption of solar radiation, as well as an indirect effect as cloud condensation nuclei which can modify the shortwave reflectivity of clouds. Sulfate aerosols tend to increase planetary albedo through both the direct and indirect effects; a cooling due to anthropogenic sulfate aerosols has been estimated of order 1 W/sq m, noting that this is similar in magnitude to the present anthropogenic greenhouse gas warming. Other aerosols, including those from biomass burning and wind-blown desert dust are also of potential climatic importance. At present, the only global monitoring of tropospheric aerosols is a NOAA operational product, aerosol optical thickness, obtained using channel-1 (0.58-0.68 mu m) radiances from the AVHRR. With this single channel radiance data, one must use an approach which is based on the inferred excess of reflected radiance owing to scattering by the aerosols over that expected from theoretical calculations. This approach is suited only for situations where the surface has a low albedo that is well known a priori. Thus, the NOAA operational product is restricted to coverage over the ocean at AVHRR scan angles well away from sun glint, and aerosol changes are subject to confusion with changes caused by either optically thin or subpixel clouds. Because optically thin aerosols have only a small effect on the radiance, accurate measurements for optical thickness less than 0.1 (which is a typical background level) are precluded. Moreover, some of the largest and most important aerosol changes are expected over land. The Earth Observing Scanning Polarimeter (EOSP) instrument, based upon design heritage and analysis techniques developed for planetary missions, will retrieve tropospheric aerosol characteristics from measurements of multispectral radiance and polarization. Moreover, the same radiance and polarization measurements will also provide very precise information on cloud properties and maps of surface characteristics for cloud-free regions. These capabilities also give EOSP the unique ability to discriminate aerosol from clouds and surface.

Travis, Larry↗

Hydrogen film/conductive cooling

Small scale nozzle tests using heated nitrogen were run to obtain effectiveness and wall heat transfer data with hydrogen film cooling. Effectiveness data are compared with an entrainment model developed from planar, unaccelerated flow data. Results indicate significant effects due to flow turning and acceleration. With injection velocity effects accounted for explicitly, heat transfer correlation coefficients were found to be the same with and without film cooling when properties are evaluated at an appropriate reference temperature for the local gas composition defined by the coolant effectiveness. A design study for an O2/H2 application with 300 psia (207 N/sq cm) chamber pressure and 1500 lbs (6670 N) thrust indicates an adiabatic wall design requires 4 to 5 percent of the total flow as hydrogen film cooling. Internal regenerative cooling designs were found to offer no reduction in coolant requirements.

Ewen, R. L.↗

Prediction of Film Cooling on Gas Turbine Airfoils

A three-dimensional Navier-Stokes analysis tool has been developed in order to study the effect of film cooling on the flow and heat transfer characteristics of actual turbine airfoils. An existing code (Arnone et al., 1991) has been modified for the purpose. The code is an explicit, multigrid, cell-centered, finite volume code with an algebraic turbulence model. Eigenvalue scaled artificial dissipation and variable-coefficient implicit residual smoothing are used with a full-multigrid technique. Moreover, Mayle's transition criterion (Mayle, 1991) is used. The effects of film cooling have been incorporated into the code in the form of appropriate boundary conditions at the hole locations on the airfoil surface. Each hole exit is represented by several control volumes, thus providing an ability to study the effect of hole shape on the film-cooling characteristics. Comparison is fair with near mid-span experimental data for four and nine rows of cooling holes, five on the shower head, and two rows each on the pressure and suction surfaces. The computations, however, show a strong spanwise variation of the heat transfer coefficient on the airfoil surface, specially with shower-head cooling.

Garg, Vijay K.↗

Mechano-caloric cooling device

The mechano-caloric effect is potentially useful in the He II temperature range. Aside from demonstration work, little quantification effort appears to have been known since other refrigeration possibilities have been available for some time. Successful He II use-related system examples are as follows: in space, the utilization of the latent heat of vaporization has been quite successful in vapor-liquid phase separation (VLPS) in conjunction with thermomechanical force application in plugs. In magnet cooling systems, the possibility of using the mechano-caloric cooling effect in conjunction with thermo-mechanical circulation pump schemes, has been assessed (but not quantified yet to the extent desirable). A third example is quoted in conjunction with superfluid wind tunnel studies and liquid helium tow tank for surface vessels respectively. In all of these (partially future) R and D areas, the question of refrigerator effectiveness using the mechano-caloric effect appears to be relevant, possibly in conjunction with questions of reliability and simplicity. The present work is concerned with quantification of phenomena including simplified thermodynamic cycle calculations.

Frederking, T. H. K.↗

Effect of neck warming and cooling on thermal comfort

The potential use of local neck cooling in an area superficial to the cerebral arteries was evaluated by circulating cold or hot water through two copper disks held firmly against the neck. Subjective responses indicated that neck cooling improves the thermal comfort in a hot environment.

Williams, B. A.↗

Molecular-beam gas-sampling system

A molecular beam mass spectrometer system for rocket motor combustion chamber sampling is described. The history of the sampling system is reviewed. The problems associated with rocket motor combustion chamber sampling are reported. Several design equations are presented. The results of the experiments include the effects of cooling water flow rates, the optimum separation gap between the end plate and sampling nozzle, and preliminary data on compositions in a rocket motor combustion chamber.

Young, W. S.↗

Ultraviolet photometry from the Orbiting Astronomical Observatory. VIII

A comprehensive ultraviolet photometric survey of the blue Ap stars was conducted in order to determine whether the close similarity, deduced from ground observations, between the blue Ap stars and normal B stars with similar UBV colors is maintained at wavelengths shortward of 3000 A. Data are presented for 24 Ap stars and 31 normal comparison standard dwarfs and giants observed by the Wisconsin Experiment Package on OAO 2. Both normal and peculiar stars were chosen, with a few exceptions, for their minimal interstellar reddening and for the absence of known bright companions. The similarity between blue Ap stars and normal B stars of similar UBV colors is not maintained in the ultraviolet. The blue Ap stars emit less ultraviolet flux than normal stars of like UBV colors. They are underluminous and cool in effective temperature for their colors.

Leckrone, D. S.↗

A computer program for full-coverage film-cooled blading analysis including the effects of a thermal barrier coating

The program input, coolant flow and heat transfer model, and the program output are discussed. As an example, sections of the suction and pressure sides of a high temperature, high pressure turbine vane are analyzed to show the effects of a thermal barrier coating. Compared to the uncoated design, the coating halves the required coolant flow, while simultaneously reducing metal outer temperatures by over 111 K.

Source record↗

The effect of direct heating and cooling of heat regulation centers on body temperature

Experiments were done on 28 rabbits in which puncture instruments were left in the brain for 1-2 days until the calori-puncture hyperthermia had passed and the body temperature was again normal. The instrument remaining in the brain was then used as a galvanic electrode and a second fever was produced, this time due to the electrical stimulus. It was concluded that heat is a centrally acting antipyretic and that cold is a centrally acting stimulus which produces hyperpyrexia cold-induced fever.

Barbour, H. G.↗

Compositional variation in late-stage differentiates in mare lavas, as indicated by silicate melt inclusions

Questions regarding an interpretation of data from silicate melt inclusions are considered, taking into account the fragmental nature of the record, the possible effects of cooling rate on late-stage melt composition, and the crystallization of the trapped melt. New data related to 484 new analyses are provided in a separate table. Textural and mineralogical features and bulk chemical composition for an overall characterization of late-stage differentiates are discussed. A description is presented of a grouping and recognition of rock types on the basis of late-stage inclusion analyses. Attention is given to the bimodality of potassium values and the delineation of differentiation trends. It is found that many of the problems in interpretation and much of the scatter found in the composition of silicate melt inclusions in lunar samples can be attributed to the incomplete nature of the record and to crystallization after trapping.

Roedder, E.↗

Performance of computer-optimized tapered-roller bearings to 2.4 million DN

The performance of 120.65 mm bore high speed design tapered roller bearings was investigated at shaft speeds to 20,000 rpm under combined thrust and radial load. The test bearing design was computer optimized for high speed operation. Temperature distribution and bearing heat generation were determined as a function of shaft speed, radial and thrust loads, lubricant flow rates, and lubricant inlet temperature. The roller bearing operated successfully at shaft speeds up to 20,000 rpm under heavy thrust and radial loads. Cup cooling was effective in decreasing the high cup temperatures to levels equal to the cone temperature.

Parker, R. J.↗

Lubrication of optimized-design tapered-roller bearings to 2.4 million DN

The performance of 120.65 mm (4.75 in.) bore high speed design, tapered roller bearings was investigated at shaft speeds to 20,000 rpm (2.4 million DN) under combined thrust and radial load. The test bearing design was computer optimized for high speed operation. Temperature distribution bearing heat generation were determined as a function of shaft speed, radial and thrust loads, lubricant flow rates, and lubricant inlet temperature. The high speed design, tapered roller bearing operated successfully at shaft speeds up to 20,000 rpm under heavy thrust and radial loads. Bearing temperatures and heat generation with the high speed design bearing were significantly less than those of a modified standard bearing tested previously. Cup cooling was effective in decreasing the high cup temperatures to levels equal to the cone temperature.

Parker, R. J.↗