Search NASA⌕ Search

SEARCH · Search NASA

Results for “DETAILS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Detailed characterization of laser-produced astrophysically-relevant jets formed via a poloidal magnetic nozzle

We report that the collimation of astrophysically-relevant plasma ejecta in the form of narrow jets via a poloidal magnetic field is studied experimentally by irradiating a target situated in a 20 T axial magnetic field with a 40 J, 0.6 ns, 0.7 mm diameter, high-power laser. The dynamics of the plasma shaping by the magnetic field are studied over 70 ns and up to 20 mm from the source by diagnosing the electron density, temperature and optical self-emission. These show that the initial expansion of the plasma is highly magnetized, which leads to the formation of a cavity structure when the kinetic plasma pressure compresses the magnetic field, resulting in an oblique shock [A. Ciardi et al., Phys. Rev. Lett. 110, 025002 (2013)]. The resulting poloidal magnetic nozzle collimates the plasma into a narrow jet [B. Albertazzi et al., Science 346, 325 (2014)]. At distances far from the target, the jet is only marginally magnetized and maintains a high aspect ratio due to its high Mach-number (M~20) and not due to external magnetic pressure. The formation of the jet is evaluated over a range of laser intensities (10 12 –10 13 W/cm 2 ), target materials and orientations of the magnetic field. Lastly, plasma cavity formation is observed in all cases and the viability of long-range jet formation is found to be dependent on the orientation of the magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantifying CO 2 storage efficiency factors in hydrocarbon reservoirs. A detailed look at CO 2 Enhanced Oil Recovery

Carbon dioxide (CO 2 ) enhanced oil recovery (EOR) will likely be the primary means of geologic CO 2 storage during the early stages of commercial-scale carbon capture and storage (CCS) because of the inherent economic incentives as well as the abundant experience and demonstrated success in the United States, where CO 2 EOR has been employed since 1974. The work presented here estimates CO 2 storage efficiency factors in CO 2 EOR operations using a unique industry database of CO 2 EOR sites and 12 different reservoir simulation models. The simulation models encompass fluvial clastic and shallow shelf carbonate depositional environments for reservoir depths of 1219 and 2438 m (4000 and 8000 feet) and 7.6-, 20-, and 64-m (25-, 66-, and 209-foot)-thick pay zones. A novel statistical modeling technique incorporating the Michaelis–Menten function is used to generate empirical percentile estimates of CO 2 storage efficiency factors. West Texas San Andres dolomite water alternating gas (WAG) CO 2 flood performance data were used to derive P10, P50, and P90 CO 2 storage efficiency factors of 0.76, 1.28, and 1.74 Mscf/STB (stock tank barrel) of original oil in place. Median CO 2 storage efficiency factors from continuous CO 2 injection following conventional waterflood varied from 15% to 61% and 8% to 40% for fluvial clastic and shallow shelf carbonate simulation models, respectively, while those from WAG injection varied from 14% to 42% and 8% to 31%, respectively. Variation in the CO 2 storage efficiency factors was largely attributable to reservoir depth (a surrogate for reservoir pressure and temperature) and lithology (clastic versus carbonate). The results of this work provide practical information that can be used to quantify CO 2 storage resource estimates in oil reservoirs during CO 2 EOR operations (as opposed to storage following depletion) and the uncertainty associated with those estimates.

54 ENVIRONMENTAL SCIENCES↗

Gaseous jet through an outward opening injector: Details of mixing characteristic and turbulence scales

Direct injection (DI) strategy of natural gas (NG) into internal combustion engines (ICE) has led to higher thermal efficiency and lower exhaust emissions. In order to thoroughly understand the most relevant phenomena affecting the performances of such engines, computational fluid dynamics (CFD) plays a key role as an accurate description of the jet evolution and interaction within the combustion chamber is required to that aim. Accurate description of high-pressure gaseous jets is rather challenging at high Mach numbers, as the injected gas is strongly under-expanded once in the ambient, giving room to shocks due to compressibility effects. Also the interaction between shock waves and mixing layers needs to be carefully represented with a multi-dimensional model, calling for substantial computational resources requirements. In this paper a numerical investigation of the behavior of a gaseous jet (Argon) through an outward opening injector has been carried out. A Large Eddy Simulation (LES) approach has been used in order to track the structures derived by the interaction of the injected fuel with the surrounding ambient. Although already good results were obtained using a Reynolds Averaged Navier-Stokes (RANS) approach, the adoption of LES is required to characterize more accurately the jet properties in terms of vortex structures and mixing effectiveness. Finally, the effect of the Nozzle Pressure Ratio (NPR) on the jet evolution has been highlighted in the paper, showing how a higher NPR would give a faster injection process, compromising however the homogeneity of the mixture.

33 ADVANCED PROPULSION SYSTEMS↗

Detailed mixing measurements from single-hole converging ECN injectors using Rayleigh scattering

Time resolved liquid and vapor fields of dodecane and oxymethylene ethers are measured from Spray A-3 and Spray D using high speed Rayleigh scattering and diffuse back illumination at the Engine Combustion Network (ECN) Spray A condition of 900 K and 22.8 kg/m 3 . Global quantities including mixture fraction, vapor and liquid penetration, as well as spreading angle are measured. The mixture fraction fields and vapor penetration profiles are well predicted by the 1-D Musculus-Kattke model. The mixture fraction field and vapor penetration from Spray A-3 are similar to those measured from Spray A in previous works. Spray D exhibits higher mixture fraction fields and vapor penetration due to its larger nozzle diameter. The quasi-steady mixture fraction fields from these injectors scale well when distance from the injector is normalized by the nozzle diameter. The turbulent dissipation structures were also analyzed based on the orientation, thickness, and magnitude of the mixing layers. Furthermore, the orientation and thickness are similar to other measurements in atmospheric gas jets, while the magnitude is lower. The thickness and magnitude are subject to uncertainties due to limitations in the imaging resolution of the system but still provide an order of magnitude as a useful reference for comparison against computational fluid dynamic simulations.

33 ADVANCED PROPULSION SYSTEMS↗

Detailed assessment of diesel spray atomization models using visible and X-ray extinction measurements

The physical mechanisms characterizing the breakup of a diesel spray into droplets are still unknown. This gap in knowledge has largely been due to the challenges of directly imaging this process or quantitatively measuring the outcomes of spray breakup, such as droplet size. Recent x-ray measurements by Argonne National Laboratory, utilized in this work, provide needed information about the spatial evolution of droplet sizes in selected regions of the spray under a range of injection pressures (50–150 MPa) and ambient densities (7.6–22.8 kg/m3) relevant for diesel operating conditions. Ultra-small angle x-ray scattering (USAXS) measurements performed at the Advanced Photon Source are presented, which quantify Sauter mean diameters (SMD) within optically thick regions of the spray that are inaccessible by conventional droplet sizing measurement techniques, namely in the near-nozzle region, along the spray centerline, and within the core of the spray. To quantify droplet sizes along the periphery of the spray, a complementary technique is proposed and introduced, which leverages the ratio of path-integrated x-ray and visible laser extinction (SAMR) measurements to quantify SMD. The SAMR and USAXS measurements are then utilized to evaluate current spray models used for engine computational fluid dynamic (CFD) simulations. We explore the ability of a carefully calibrated spray model, premised on aerodynamic wave growth theory, to capture the experimentally observed trends of SMD throughout the spray. The spray structure is best predicted with an aerodynamic primary and secondary breakup process that is represented with a slower time constant and larger formed droplet size than conventionally recommended for diesel spray models. Additionally, spray model predictions suggest that droplet collisions may not influence the resultant droplet size distribution along the spray centerline in downstream regions of the spray.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study to Determine Adequate Margins in Radiotherapy Planning for Esophageal Carcinoma by Detailing Patterns of Recurrence After Definitive Chemoradiotherapy

Purpose: To ascertain the adequacy of radiotherapy (RT) margins by studying the relapse patterns after definitive chemoradiotherapy for carcinoma of the esophagus. Methods and Materials: We performed a retrospective study assessing the first site of disease relapse after definitive chemoradiotherapy that included four 3-weekly cycles of cisplatin and continuous infusion 5-fluorouracil, with conformal RT (50 Gy in 25 fractions) concurrent with Cycles 3 and 4. The RT planning target volume was the endoscopic ultrasonography/computed tomography-defined gross tumor volume with 1.5-cm lateral and 3-cm superoinferior margins. Results: A total of 145 patients were included. Their average age was 65.4 years, 45% had adenocarcinoma, 61% had lower third esophageal tumors, and 75% had Stage III-IVA disease. After RT, of 142 patients, 85 (60%) had evidence of relapse at a median follow-up of 18 months. The relapse was local (within the RT field) in 55; distant (metastatic) in 13, and a combination of local and distant in 14. The local relapse rates were not influenced by tumor stage, lymph node status, or disease length. Three patients developed a relapse in regions adjacent to the RT fields; however, it is unlikely that larger field margins would have been clinically acceptable or effective in these cases. The median overall survival was 15 months. Conclusion: The gross tumor volume-planning target volume margins in this study appeared adequate. Future efforts to improve outcomes using definitive chemoradiotherapy should be directed toward reducing the high rates of in-field and distant relapses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detailed Characterization of the Early Response of Head-Neck Cancer Xenografts to Irradiation Using {sup 18}F-FDG-PET Imaging

Purpose: To investigate the metabolic information provided by {sup 18}F-fluorodeoxyglucose-positron emission tomography (FDG-PET) during the early response of head-and-neck squamous cell carcinoma (HNSCC) xenografts to radiotherapy (RT). Methods and Materials: Low-passage HNSCC cells (UT14) were injected into the rear flanks of female nu/nu mice to generate xenografts. After tumors grew to 400-500 mm{sup 3}, they were treated with either 15 Gy in one fraction (n = 18) or sham RT (n = 12). At various time points after treatment, tumors were assessed with 2-h dynamic FDG-PET and immediately harvested for direct histological correlation. Different analytical parameters were used to process the dynamic PET data: kinetic index (Ki), standard uptake value (SUV), sensitivity factor (SF), and retention index (RI). Tumor growth was assessed using the specific growth rate (SGR) and correlated with PET parameters using the Pearson correlation coefficient (r). Receiver operating characteristic (ROC) and the area under the ROC curve (AUC) were used to test PET parameters for their ability to predict for radiation necrosis and radiation change. Results: Tumor growth was arrested for the first 20 days after RT and recovered thereafter. Histologically, radiation change was observed in the peripheral regions of tumors between days 7 and 23 after RT, and radiation necrosis were observed in the central regions of tumors between days 7 and 40. Ki provided the best correlation with SGR (r = 0.51) and was the optimal parameter to predict for early radiation necrosis (AUC = 0.804, p = 0.07). SUV{sub 30min} was the strongest predictor for late radiation necrosis (AUC = 0.959, p = 0.004). Both RI{sub 30-60min} and SF{sub 12-70min} were very accurate in predicting for radiation change (AUC = 0.891 and 0.875, p = 0.009 and 0.01, respectively). Conclusions: Dynamic FDG-PET analysis (such as Ki or SF) may provide informative assessment of early radiation necrosis or radiation change of HNSCC xenografts after RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk Factors for Neovascular Glaucoma After Proton Beam Therapy of Uveal Melanoma: A Detailed Analysis of Tumor and Dose–Volume Parameters

Purpose: To determine neovascular glaucoma (NVG) incidence and identify contributing tumor and dosing factors in uveal melanoma patients treated with proton beam radiation therapy (PBRT). Methods and Materials: A total of 704 PBRT patients treated by a single surgeon (DHC) for uveal melanoma (1996-2010) were reviewed for NVG in our prospectively maintained database. All patients received 56 GyE in 4 fractions. Median follow-up was 58.3 months. Analyses included the Kaplan-Meier method to estimate NVG distributions, univariate log–rank tests, and Cox's proportional hazards multivariate analysis using likelihood ratio tests to identify independent risk factors of NVG among patient, tumor, and dose–volume histogram parameters. Results: The 5-year PBRT NVG rate was 12.7% (95% confidence interval [CI] 10.2%-15.9%). The 5-year rate of enucleation due to NVG was 4.9% (95% CI 3.4%-7.2%). Univariately, the NVG rate increased significantly with larger tumor diameter (P<.0001), greater height (P<.0001), higher T stage (P<.0001), and closer proximity to the disc (P=.002). Dose–volume histogram analysis revealed that if >30% of the lens or ciliary body received ≥50% dose (≥28 GyE), there was a higher probability of NVG (P<.0001 for both). Furthermore, if 100% of the disc or macula received ≥28 GyE, the NVG rate was higher (P<.0001 and P=.03, respectively). If both anterior and posterior doses were above specified cut points, NVG risk was highest (P<.0001). Multivariate analysis confirmed significant independent risk factors to include tumor height (P<.0001), age (P<.0001), %disc treated to ≥50% Dose (<100% vs 100%) (P=.0007), larger tumor diameter (P=.01), %lens treated to ≥90% Dose (0 vs >0%-30% vs >30%) (P=.01), and optic nerve length treated to ≥90% Dose (≤1 mm vs >1 mm) (P=.02). Conclusions: Our current PBRT patients experience a low rate of NVG and resultant enucleation compared with historical data. The present analysis shows that tumor height, diameter, and anterior as well as posterior critical structure dose–volume parameters may be used to predict NVG risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Course of Quality of Life After Radiation Therapy for Painful Bone Metastases: A Detailed Analysis From the Dutch Bone Metastasis Study

Purpose: To study the course of quality of life (QoL) after radiation therapy for painful bone metastases. Patients and Methods: The Dutch Bone Metastasis Study randomized 1157 patients with painful bone metastases between a single fraction of 8 Gy and 6 fractions of 4 Gy between 1996 and 1998. The study showed a comparable pain response of 74%. Patients filled out weekly questionnaires for 13 weeks, then monthly for 2 years. In these analyses, physical, psychosocial, and functional QoL domain scores and a score of general health were studied. Mixed modeling was used to model the course of QoL and to study the influence of several characteristics. Results: In general, QoL stabilized after 1 month. Psychosocial QoL improved after treatment. The level of QoL remained stable, steeply deteriorating at the end of life. For most QoL domains, a high pain score and intake of opioids were associated with worse QoL, with small effect sizes (−0.11 to −0.27). A poor performance score was associated with worse functional QoL, with a medium effect size (0.41). There is no difference in QoL between patients receiving a single fraction of 8 Gy and 6 fractions of 4 Gy, except for a temporary worsening of physical QoL after 6 fractions. Conclusion: Although radiation therapy for painful bone metastases leads to a meaningful pain response, most domains of QoL do not improve after treatment. Only psychosocial QoL improves slightly after treatment. The level of QoL is related to the actual survival, with a rather stable course of QoL for most of the remaining survival time and afterward a sharp decrease, starting only a few weeks before the end of life. Six fractions of 4 Gy lead to a temporary worse physical QoL compared with a single fraction of 8 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗