Search NASA⌕ Search

SEARCH · Search NASA

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

The MicroBooNE Detector: Status After Three Years of Data Taking

MicroBooNE is a 100-ton scale liquid-argon time projection chamber (LArTPC) neutrino experiment located on the Booster neutrino beamline at Fermilab. The experiment first started collecting neutrino data in October 2015. The detector, the first in the short-baseline neutrino program at Fermilab, is the longest operating LArTPC to date and plays an important role in a phased program towards the construction of massive kiloton scale detectors for future long-baseline neutrino physics (DUNE). We present results on the performance of the detector after three years of data-taking, highlighting operational accomplishments such as the high electron lifetime and signal-to-noise levels achieved. Additionally, we describe the current state of MicroBooNE reconstruction, presenting results which show the detector's ability to perform sub-millimeter tracking and produce accurate momentum and calorimetric measurements capable of enabling the analyses needed to explore the exciting neutrino interaction physics this detector was built for.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Performance of LHCf Detector

In cosmic ray physics, the uncertainty of the hadron interaction model causes systematic errors of air shower simulations in high-energy region. To solve the problem, the LHCf experiment measures energies and transverse momenta of neutral particles emitted in the forward region of 14 TeV p-p collision at CERN LHC. Two LHCf detectors, consisting of sampling and imaging calorimeters, are installed at zero degree collision angle at + 140 m from the interaction point 1 (IP1). The energy resolution is confirmed as to be <5% and the position resolution <0.2 mm for gamma-rays with energies from 100 GeV to 200 GeV by test beam results at the CERN SPS. Use of the Front Counter reduces the beam-gas background by a factor 50.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A flexible event reconstruction based on machine learning and likelihood principles

Event reconstruction is a central step in many particle physics experiments, turning detector observables into parameter estimates; for example estimating the energy of an interaction given the sensor readout of a detector. A corresponding likelihood function is often intractable, and approximations need to be constructed. Here, in our work, we first show how the full likelihood for a many-sensor detector can be broken apart into smaller terms, and secondly how we can train neural networks to approximate all terms solely based on forward simulation. Our technique results in a fast, flexible, and close-to-optimal surrogate model proportional to the likelihood and can be used in conjunction with standard inference techniques allowing for a consistent treatment of uncertainties. We illustrate our technique for parameter inference in neutrino telescopes based on maximum likelihood and Bayesian posterior sampling. Given its great flexibility, we also showcase our method for geometry optimization enabling to learn optimal detector designs. Lastly, we apply our method to realistic simulation of a ton-scale water-based liquid scintillator detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Das ist der HAMMER: consistent new physics interpretations of semileptonic decays

Abstract Precise measurements of $$b\rightarrow c\tau \bar{\nu }$$ b → c τ ν ¯ decays require large resource-intensive Monte Carlo (MC) samples, which incorporate detailed simulations of detector responses and physics backgrounds. Extracted parameters may be highly sensitive to the underlying theoretical models used in the MC generation. Because new physics (NP) can alter decay distributions and acceptances, the standard practice of fitting NP Wilson coefficients to SM-based measurements of the $$R(D^{(*)})$$ R ( D ( ∗ ) ) ratios can be biased. The newly developed software tool enables efficient reweighting of MC samples to arbitrary NP scenarios or to any hadronic matrix elements. We demonstrate how allows avoidance of biases through self-consistent fits directly to the NP Wilson coefficients. We also present example analyses that demonstrate the sizeable biases that can otherwise occur from naive NP interpretations of SM-based measurements. The library is presently interfaced with several existing experimental analysis frameworks and we provide an overview of its structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gain characterization of LGAD sensors with beta particles and 28-MeV protons

Low Gain Avalanche Diodes, also known as LGADs, are widely considered for fast-timing applications in high energy physics, nuclear physics, space science, medical imaging, and precision measurements of rare processes. Such devices are silicon-based and feature an intrinsic gain due to a p + -doped layer that allows the production of a controlled avalanche of carriers, with multiplication on the order of 10–100. This technology can provide time resolution on the order of 20–30 ps, and variants of this technology can provide precision tracking too. The characterization of LGAD performance has so far primarily been focused on the interaction of minimum ionizing particles for high energy and nuclear physics applications. This article expands the study of LGAD performance to highly-ionizing particles, such as 28-MeV protons, which are relevant for several future scientific applications, e.g. in biology and medical physics, among others. These studies were performed with a beam of 28-MeV protons from a tandem Van de Graaff accelerator at Brookhaven National Laboratory and beta particles from a ^90Sr source; these were used to characterize the response and the gain of an LGAD as a function of bias voltage and collected charge. Here, the experimental results are also compared to TCAD simulations.

47 OTHER INSTRUMENTATION↗

Target jet substructure and correlation

We discuss the reconstruction of target jet and the framework of quantifying its internal substructure. Due to momentum and charge conservation, target and current correlation can be exploited which significantly constrains the event-wide particle distributions. We demonstrate this method using Pythia simulations of electron-proton collisions in the context of determining the flavor and substructure of the struck quark jet. Extensions to electron-ion collisions and target tagging using BeAGLE simulations will be discussed. This study will provide novel physics cases for forward detector designs and promote the synergy with nuclear physics.

Chien, Yang-Ting↗

The Majorana Project

Working as part of a collaborative team, PNNL is bringing its signature capability in ultra-low-level detection to help search for a rare form of radioactive decay-never before detected-called "neutrinoless double beta decay" in germanium. If observed, it would demonstrate neutrinos are Majorana-type particles. This discovery would show neutrinos are unique among fundamental particles, having a property whereby the matter and anti-matter version of this particle are indistinguishable. Physicist John L. Orrell explains how they rely on the Shallow Underground Laboratory to conduct the research.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Short-Baseline Near Detector at Fermilab: Input to the European Strategy for Particle Physics 2026 Update

SBND is a 112 ton liquid argon time projection chamber (LArTPC) neutrino detector located 110 meters from the Booster Neutrino Beam (BNB) target at Fermilab. Its main goals include searches for eV-scale sterile neutrinos as part of the Short-Baseline Neutrino (SBN) program, other searches for physics beyond the Standard Model, and precision studies of neutrino-argon interactions. In addition, SBND is providing a platform for LArTPC neutrino detector technology development and is an excellent training ground for the international group of scientists and engineers working towards the upcoming flagship Deep Underground Neutrino Experiment (DUNE). SBND began operation in July 2024, and started collecting stable neutrino beam data in December 2024 with an unprecedented rate of ~7,000 neutrino events per day. During its currently approved operation plans (2024-2027), SBND is expected to accumulate nearly 10 million neutrino interactions. The near detector dataset will be instrumental in testing the sterile neutrino hypothesis with unprecedented sensitivity in SBN and in probing signals of beyond the Standard Model physics. It will also be used to significantly advance our understanding of the physics of neutrino-argon interactions ahead of DUNE. After the planned accelerator restart at Fermilab (2029+), opportunities are being explored to operate SBND in antineutrino mode in order to address the scarcity of antineutrino-argon scattering data, or in a dedicated beam-dump mode to significantly enhance sensitivity to searches for new physics. SBND is an international effort, with approximately 40% of institutions from Europe, contributing to detector construction, commissioning, software development, and data analysis. Continued European involvement and leadership are essential during SBND's operations and analysis phase for both the success of SBND, SBN and its role leading up to DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Focal Plane Detectors for the Advanced Gamma-Ray Imaging System (AGIS)

The Advanced Gamma-Ray Imaging System (AGIS) is a concept for the next generation observatory in ground-based very high energy gamma-ray astronomy. Design goals are ten times better sensitivity, higher angular resolution, and a lower energy threshold than existing Cherenkov telescopes. Simulations show that a substantial improvement in angular resolution may be achieved if the pixel diameter is reduced to the order of 0.05 deg, i.e. two to three times smaller than the pixel diameter of current Cherenkov telescope cameras. At these dimensions, photon detectors with smaller physical dimensions can be attractive alternatives to the classical photomultiplier tube (PMT). Furthermore, the operation of an experiment with the size of AGIS requires photon detectors that are among other things more reliable, more durable, and possibly higher efficiency photon detectors. Alternative photon detectors we are considering for AGIS include both silicon photomultipliers (SiPMs) and multi-anode photomultipliers (MAPMTs). Here we present results from laboratory testing of MAPMTs and SiPMs along with results from the first incorporation of these devices into cameras on test bed Cherenkov telescopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-pixel integration of signal processing and AI/ML based data filtering for particle tracking detectors

We present the first physical realization of in-pixel signal processing with integrated AI-based data filtering for particle tracking detectors. Building on prior work that demonstrated a physics-motivated edge-AI algorithm suitable for ASIC implementation, this work marks a significant milestone toward intelligent silicon trackers. Our prototype readout chip performs real-time data reduction at the sensor level while meeting stringent requirements on power, area, and latency. The chip is taped-out in 28nm TSMC CMOS bulk process, which has been shown to have sufficient radiation hardness for particle experiments. This development represents a key step toward enabling fully on-detector edge AI, with broad implications for data throughput and discovery potential in high-rate, high-radiation environments such as the High-Luminosity LHC.

Parpillon, Benjamin [Fermilab; Illinois U., Chicag↗

Gravitational wave background from Standard Model physics: qualitative features

Because of physical processes ranging from microscopic particle collisions to macroscopic hydrodynamic fluctuations, any plasma in thermal equilibrium emits gravitational waves. For the largest wavelengths the emission rate is proportional to the shear viscosity of the plasma. In the Standard Model at T>160 GeV, the shear viscosity is dominated by the most weakly interacting particles, right-handed leptons, and is relatively large. We estimate the order of magnitude of the corresponding spectrum of gravitational waves. Even though at small frequencies (corresponding to the sub-Hz range relevant for planned observatories such as eLISA) this background is tiny compared with that from non-equilibrium sources, the total energy carried by the high-frequency part of the spectrum is non-negligible if the production continues for a long time. We suggest that this may constrain (weakly) the highest temperature of the radiation epoch. Observing the high-frequency part directly sets a very ambitious goal for future generations of GHz-range detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Segmentation-free empirical beam hardening correction for CT

Purpose: The polychromatic nature of the x-ray beams and their effects on the reconstructed image are often disregarded during standard image reconstruction. This leads to cupping and beam hardening artifacts inside the reconstructed volume. To correct for a general cupping, methods like water precorrection exist. They correct the hardening of the spectrum during the penetration of the measured object only for the major tissue class. In contrast, more complex artifacts like streaks between dense objects need other techniques of correction. If using only the information of one single energy scan, there are two types of corrections. The first one is a physical approach. Thereby, artifacts can be reproduced and corrected within the original reconstruction by using assumptions in a polychromatic forward projector. These assumptions could be the used spectrum, the detector response, the physical attenuation and scatter properties of the intersected materials. A second method is an empirical approach, which does not rely on much prior knowledge. This so-called empirical beam hardening correction (EBHC) and the previously mentioned physical-based technique are both relying on a segmentation of the present tissues inside the patient. The difficulty thereby is that beam hardening by itself, scatter, and other effects, which diminish the image quality also disturb the correct tissue classification and thereby reduce the accuracy of the two known classes of correction techniques. The herein proposed method works similar to the empirical beam hardening correction but does not require a tissue segmentation and therefore shows improvements on image data, which are highly degraded by noise and artifacts. Furthermore, the new algorithm is designed in a way that no additional calibration or parameter fitting is needed. Methods: To overcome the segmentation of tissues, the authors propose a histogram deformation of their primary reconstructed CT image. This step is essential for the proposed algorithm to be segmentation-free (sf). This deformation leads to a nonlinear accentuation of higher CT-values. The original volume and the gray value deformed volume are monochromatically forward projected. The two projection sets are then monomially combined and reconstructed to generate sets of basis volumes which are used for correction. This is done by maximization of the image flatness due to adding additionally a weighted sum of these basis images. sfEBHC is evaluated on polychromatic simulations, phantom measurements, and patient data. The raw data sets were acquired by a dual source spiral CT scanner, a digital volume tomograph, and a dual source micro CT. Different phantom and patient data were used to illustrate the performance and wide range of usability of sfEBHC across different scanning scenarios. The artifact correction capabilities are compared to EBHC. Results: All investigated cases show equal or improved image quality compared to the standard EBHC approach. The artifact correction is capable of correcting beam hardening artifacts for different scan parameters and scan scenarios. Conclusions: sfEBHC generates beam hardening-reduced images and is furthermore capable of dealing with images which are affected by high noise and strong artifacts. The algorithm can be used to recover structures which are hardly visible inside the beam hardening-affected regions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Cylindrical GEM Detector with Analog Readout for the BESIII Experiment

Inner Trackers (IT) are key detectors in Particle Physics experiments; excellent spatial resolution, radiation transparency and hardness, and operability under high occupancies are main requirements. We aim to design, build and commission by 2017 a Cylindrical GEM (CGEM) detector candidate to be the new IT of the BESIII spectrometer, hosted on BEPC2 in IHEP, Beijing; BESIII data taking will last until at least 2020. The IT itself will represent an evolution w.r.t. the state of the art of GEM detectors, since the use of new kind of mechanical supports for the GEM foils will reduce the total radiation length of the detector and improve its tracking performance; an innovative design of the CGEM anode will allow for smaller capacitance and hence for bigger signals. The relatively strong BESIII magnetic field requires a new analogue readout; full custom front-end electronics, including a dedicated ASIC, will be designed and produced for optimal data collection. Prototype Beam Test results showing the measurement of the spatial resolution in a 1 Tesla magnetic field will be presented among with the mechanical design and simulations. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An efficient, movable single-particle detector for use in cryogenic ultra-high vacuum environments

A compact, highly efficient single-particle counting detector for ions of keV/u kinetic energy, movable by a long-stroke mechanical translation stage, has been developed at the Max-Planck-Institut für Kernphysik (Max Planck Institute for Nuclear Physics, MPIK). Both, detector and translation mechanics, can operate at ambient temperatures down to ∼10 K and consist fully of ultra-high vacuum compatible, high-temperature bakeable, and non-magnetic materials. The set-up is designed to meet the technical demands of MPIK’s Cryogenic Storage Ring. We present a series of functional tests that demonstrate full suitability for this application and characterise the set-up with regard to its particle detection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space-time development of electromagnetic and hadronic showers and perspectives for novel calorimetric techniques

The performance of hadronic calorimeters will be a key parameter at the next generation of High Energy Physics accelerators. A detector combining fine granularity with excellent timing information would prove beneficial for the reconstruction of both jets and electromagnetic particles with high energy resolution. In this work, the space and time structure of high energy showers is studied by means of a Geant4-based simulation toolkit. In particular, the relevant time scales of the different physics phenomena contributing to the energy loss are investigated. A correlation between the fluctuations of the energy deposition of high energy hadrons and the time development of the showers is observed, which allows for an event-by-event correction to be computed to improve the energy resolution of the calorimeter. Lastly, these studies are intended to set the basic requirements for the development of a new-concept, total absorption time-imaging calorimeter, which seems now within reach thanks to major technological advancements in the production of fast scintillating materials and compact photodetectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements and searches for new physics in diboson processes with the D0 detector

This dissertation describes a comprehensive study of the Zγ → eeγ/μμγ/v$\bar{v}$γ process. The data have been collected with the DØ detector at the Fermilab Tevatron p¯p collider with the center-of-mass energy of 1.96 TeV, and correspond to up to 3.6 fb -1 of integrated luminosity. Firstly, in this study we perform a measurement of the Z production cross section. The measured cross sections in both ℓℓγ (ℓ= e or μ) and /v$\bar{v}$γ channels are the most precise cross sections measured at hadron colliders to date, and they agree within uncertainties with the theoretical calculations to the next-to-leading order. We claim the first observation of the Zγ → eeγ/μμγ/v$\bar{v}$γ process at hadron colliders at 5.1 standard deviations statistical significance. We also conduct a search for anomalous Zγ processes. Such anomalous Zγ processes, where a Z boson couples to a photon, result in an increased cross section and an enhancement of the production of high-energetic photons. Thus, an observation of this kind might possibly indicate the presence of new physics. Having found no excess of data over the SM expectations, we set the most restrictive 95% C.L. limits on the anomalous trilinear Z and ZZ gauge couplings (ATGC) at hadron colliders to date: |h$γ\atop{30}$| < 0.033, |h$γ\atop{40}$| < 0.0017, |h$Z\atop{30}$| < 0.033, and |h$Z\atop{40}$| < 0.0017, which mark almost three times improvement over the most recent results published to date. Three out of four current limits improve on the LEP limits, and are the tightest limits on ATGC in the world. Finally, we performed a search for narrow vector and scalar resonances that decay to Zγ . Many extensions of the SM predict such resonances, thus making this search a test of the gauge sector of the SM. We found no significant deviation of data from the SM predictions, and hence we set 95% C.L upper limits on the production cross section of the resonances.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hadron Physics with CLAS12

Hadron spectroscopy has been an essential part of the physics program with the CLAS detector in experimental Hall B at Jefferson Lab. Production of baryon and meson resonances with high energy (polarized) electron and photon beams was studied on a veriety of targets, ranging from hydrogen to lead. Physics topics of interest include: investigation of the spectrum of baryon and meson resonances, transition form-factors, meson-nucleon couplings (mesons in nuclei), and search for exotic and missing states. With the 12 GeV upgrade of the CEBAF machine, hadron spectroscopy in Hall B will be extended to a new domain of higher mass resonances and the range of higher transferred momentum using up to 11 GeV electron beams and the upgraded CLAS12 detector. In this paper a brief description of the CLAS12 detector and the physics program adopted for 12 GeV with emphasis to baryon and meson spectroscopy is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗