At least 451 records · Page 25

The Challenges of Using Real-Time Detection Systems: From Data Gathering to Actionable Information [Slides]

This session will discuss challenges and real life examples associated with Real-Time Detection Systems (RTDS) used in exposure assessment strategies. This first presentation will provide an overview of RTDS as used as part of an overall exposure assessment strategy and to document regulatory compliance. Managing OH consequences has been problematic when it comes to actionable information gleaned from sensor data. The judgement of regulatory entities, can be at odds with IH practitioners implementing an exposure strategy that creates exposure profiles and judges workplace exposures.

61 RADIATION PROTECTION AND DOSIMETRY↗

Advanced CMOS Reliability Update: Sub 20nm FinFET Assessment

Advances in FinFET design and fabrication enable manufacturing of denser, more compact integrated circuits (ICs) with substantially reduced leakage while shortening the channel-lengths. The same stress-induced leakage and breakdown degradation mechanisms that affect planar transistors also impact FinFET devices. Reliability concerns such as Bias Temperature Instability (BTI), Time Dependent Dielectric Breakdown (TDDB), and Hot Carrier Injection (HCI) become very important with changes to transistor geometry and fin sidewall crystal orientation. Recent testing has shown that FinFETs respond differently to radiation (radiation effects such as total ionizing dose) when compared to planar transistors. These reliability and radiation effects issues become very important when changing transistor geometry and scaling FinFETs towards smaller feature sizes (22-nm, 16-nm, 14- nm, 10-nm, and smaller critical dimensions). The comparable 2019 state of the art transistor densities in current high-volume manufacturing silicon-based foundries is 7-nm (ISMC, Samsung) and 10-nm (Intel) [www.anandtech.com,fuse.wikichip.org]. Released products include supporting components for the cellphone and commercial microprocessor markets respectively. Extensive development in the foundry industry is driving to a 5-nm technology node in late 2020.

47 OTHER INSTRUMENTATION↗

Compendium of Material Composition Data for Radiation Transport Modeling

In 2011, Pacific Northwest National Laboratory (PNNL) produced a document known as the Materials Compendium, or Compendium of Material Composition Data for Radiation Transport Modeling, PNNL 15870, Rev. 1, that contains material information useable for modeling purposes for properties of 372 materials. This information is used in several modeling programs used by the radiological/nuclear community, though it is primarily tailored for the Monte-Carlo-N-Particle code produced by Los Alamos National Laboratory. This new document Revision 2 includes a complete review and update of all materials data and references, addressing discrepancies and changes in materials data or references that have occurred since the first revision, an additional 40 materials have been added, primarily newer detector materials developed since the last revision, and isotopic specificity.

07 ISOTOPE AND RADIATION SOURCES↗

RCT Continuing Training (Q2 2021) [Slides]

This quarter’s training assignment is split into two sections. Section one will review the fundamental elements of removing items from controlled areas. This section discusses each decision point and the required actions to determine if an item is suitable for release. Section two briefly reviews Area Radiation Monitors, commonly referred to as ‘ARMs’, and discusses the required actions to take in the event of an ARM alarm.” Report includes slides and transcript.

61 RADIATION PROTECTION AND DOSIMETRY↗

B332 & B151 ACL Events

In September 2019, two Unexpected Radiological Event (HP-FO-601) reports were submitted to document the exceedance of a worker's default Administrative Control Level (ACL) of 100 mrem/y. One involved work in B332; the second in B151. B332 event: The worker was new to B332 and had completed qualification as an Associate Fissile Material Handler (FMH) in April of 2019. The worker received 61 mrem in June and an additional 100 mrem in July. The worker was on a monthly TLD exchange cycle. B151 event: A PLS radiochemist received ~20 mrem for the 1st quarter of the year and ~120 mrem for the 2nd quarter of the year. The worker was on a quarterly TLD exchange cycle.

61 RADIATION PROTECTION AND DOSIMETRY↗

ESH-ASI-2021-004 DOE Annual Letter (redacted markings)

File LLNL2020_DOE_GI_ANNUAL.txt was submitted electronically to the REIRS file submission. The file contains positive and zero doses for 3,308 Lawrence Livermore National Security (LLNS) and subcontractor employees. There were 96 individuals with a collective Total Effective Dose (TED) of 6,886 mrem. The 2020 data follow the DOE Radiation Exposure Monitoring Systems (REMS) format per instructions in the REMS Reporting Guide.

61 RADIATION PROTECTION AND DOSIMETRY↗

RCT: 2.01 Radiological Documentation [Slides]

10 CFR 835 establishes radiation protection standards, limits, and program requirements for protecting individuals from ionizing radiation resulting from the conduct of DOE activities. It is important to maintain the proper documentation to ensure that these standards and requirements are being met. An RCT plays a vital role in supporting these requirements through proper documentation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reference document for LANL stack sampling and ANSI N13.1 (Article) Gielow RL and McNamee MR 1993. Numerical Flue Gas Flow Modeling for Continuous Emissions Monitoring Applications. EPRI CEM Users Group Meeting. Baltimore. RP1961-13

American National Standard N13.1 “sets forth guidelines and performance criteria for sampling the emissions of airborne radioactive substances in the air discharge ducts and stacks of nuclear facilities. Emphasis is on extractive sampling from a location in a stack or duct where the contaminant is well mixed. At such a location, sampling may be conducted at a single point. This standard provides performance-based criteria for the use of air sampling probes, transport lines, sample collectors, sample monitoring instruments, and gas flow measuring methods. This standard also covers sampling program objectives, quality assurance issues, developing air sampling action levels, system optimization, and system performance verification. Workplace, containment, and environmental air monitoring are not addressed. Specific sample analysis methods and the reporting or interpreting of results are also not addressed.” (HPS 2011).

61 RADIATION PROTECTION AND DOSIMETRY↗

NCERC Capabilities [Slides]

NCERC is our nation’s only generalpurpose critical experiments facility and is one of only a few that remain operational throughout the world. The mission of the National Criticality Experiments Research Center (NCERC) is to conduct experiments and training with critical assemblies and fissionable material at or near criticality in order to explore reactivity phenomena, and to operate the assemblies in the regions from subcritical through delayed critical. One critical assembly, Godiva-IV, is designed to operate above prompt critical.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gamma Dose Measurements in ZPPR-15

Gamma doses were measured in the Zero Power Plutonium Reactor (ZPPR) to provide data for validation of calculations of gamma heating in important reactor components. Stainless steel-encapsulated LiF thermoluminescent dosimeters (TLDs) were irradiated in two configurations in ZPPR-15B and one configuration in ZPPR-15D to provide gamma heating data for the Integral Fast Reactor design in the mid-1980s. The ZPPR-15 experimental records were used to develop detailed as-built Monte Carlo models for the gamma dose measurements in ZPPR-15B and ZPPR-15D. These Monte Carlo models can be converted to deterministic models for calculations with deterministic codes. The reported uncertainty in the published gamma dose measurements is just the statistical uncertainty in the TLD readout. In addition to this statistical uncertainty in the TLD readout, several corrections and other factors contribute to the total uncertainty for the gamma dose measurements. The total uncertainty for the gamma dose measurements can be significantly larger than the published statistical uncertainty for the TLD readout. All known contributions to the total uncertainty were analyzed, and a total uncertainty was derived for the ZPPR-15 gamma dose measurements.

36 MATERIALS SCIENCE↗

Notice of Submittal – 2020 Radionuclide Air Emissions Report for Los Alamos National Laboratory

Enclosed is the Calendar Year 2020 Radionuclide Air Emissions Report for the Los Alamos National Laboratory (LANL). The submittal is in compliance with 40 CFR 61 Subpart H. The highest effective dose equivalent to any member of the public from LANL operations in 2020 is 0.29 millirem. This maximally exposed individual location is a business at 132 DP Road, Los Alamos, NM. The annual dose is well below the EPA standard of 10 millirem per year as established in Subpart H.

54 ENVIRONMENTAL SCIENCES↗

Basics of Radiation Safety [Slides]

This report explains the basics of radioactive decay, the four main types of radiation and the three phases to acute radiation syndrome. Emergency response health physics and helpful rules to the first responder follow. Tips are given for radiation detection and surveying of personnel or equipment. Several additional resources are provided.

61 RADIATION PROTECTION AND DOSIMETRY↗