Search NASA⌕ Search

SEARCH · Search NASA

Results for “Determination and Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Trajectory Optimization via Unsupervised Probabilistic Learning On Manifolds

This report investigates the use of unsupervised probabilistic learning techniques for the analysis of hypersonic trajectories. The algorithm first extracts the intrinsic structure in the data via a diffusion map approach. Using the diffusion coordinates on the graph of training samples, the probabilistic framework augments the original data with samples that are statistically consistent with the original set. The augmented samples are then used to construct conditional statistics that are ultimately assembled in a path-planing algorithm. In this framework the controls are determined stage by stage during the flight to adapt to changing mission objectives in real-time. A 3DOF model was employed to generate optimal hypersonic trajectories that comprise the training datasets. The diffusion map algorithm identfied that data resides on manifolds of much lower dimensionality compared to the high-dimensional state space that describes each trajectory. In addition to the path-planing worflow we also propose an algorithm that utilizes the diffusion map coordinates along the manifold to label and possibly remove outlier samples from the training data. This algorithm can be used to both identify edge cases for further analysis as well as to remove them from the training set to create a more robust set of samples to be used for the path-planing process.

42 ENGINEERING↗

Monitoring Helium Cryogen Usage with iFix Software at IB1 Test Facility

At the IB1 facility of the Applied Physics and Superconducting Technology Directorate within the Cryogenic Division at Fermilab, liquid helium is essential to the testing activities. The test stands used require large amounts of Helium to test the thermal and superconducting cavities and magnets. The liquid helium that enters the test stand is monitored through a series of valves and controls to determine the start and stop for monitoring time. There are 3 phases of cryogen usage that must be considered for each stand, cooldown, warming and overnight mode. With a new system in place, cold hour tracking will be more objective and precise within each test stand ensuring better calculations for user s fees that will provide funding for the replenishment of helium and continual operation at IB1.

Trillo, Angelica↗

A Physical Metric for Inertial Confinement Fusion Capsules

The performance of fusion capsules on the National Ignition Facility (NIF) is strongly affected by the physical properties of the hot deuterium–tritium (DT) fuel, such as the mass, areal density, and pressure of the hot spot at the stagnation time. All of these critical quantities depend on one measured quantity, which is the ratio of the specific peak implosion energy to the specific internal energy of the hot spot. This unique physical quantity not only can measure the incremental progress of the inertial confinement fusion capsules towards ignition but also measures the conversion of the peak implosion kinetic energy of the pusher shell into the internal energy of the hot fuel in a capsule. Analysis of existing NIF shots to date are performed. The ratio metric is compared quantitatively with the ignition criterion. Results provide new perspectives on the NIF experiments by which the performance of the burning plasma can be determined and controlled through the fine tune of the implosion parameters, which improves future designs and predictions of the ignition capsules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electronic Origin of T c in Bulk and Monolayer FeSe

FeSe is classed as a Hund’s metal, with a multiplicity of d bands near the Fermi level. Correlations in Hund’s metals mostly originate from the exchange parameter J, which can drive a strong orbital selectivity in the correlations. The Fe-chalcogens are the most strongly correlated of the Fe-based superconductors, with d xy the most correlated orbital. Yet little is understood whether and how such correlations directly affect the superconducting instability in Hund’s systems. By applying a recently developed ab initio theory, we show explicitly the connections between correlations in d xy and the superconducting critical temperature T c . Starting from the ab initio results as a reference, we consider various kinds of excursions in parameter space around the reference to determine what controls T c . We show small excursions in J can cause colossal changes in T c . Additionally we consider changes in hopping by varying the Fe-Se bond length in bulk, in the free standing monolayer M-FeSe, and M-FeSe on a SrTiO 3 substrate (M-FeSe/STO). The twin conditions of proximity of the dxy state to the Fermi energy, and the strength of J emerge as the primary criteria for incoherent spectral response and enhanced single- and two-particle scattering that in turn controls T c . Using c-RPA, we show further that FeSe in monolayer form (M-FeSe) provides a natural mechanism to enhance J. We explain why M-FeSe/STO has a high T c , whereas M-FeSe in isolation should not. Our study opens a paradigm for a unified understanding what controls Tc in bulk, layers, and interfaces of Hund’s metals by hole pocket and electron screening cloud engineering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A SYNCOM SATELLITE PROGRAM

Launching of syncom satellite to determine if control system and communications equipment can be used for advanced sychronous orbit satellites

COMMUNICATIONS SATELLITE↗

Automatic battery formation cycler and controller

Automatic battery formation cycler and controller to determine charge capacity and to perform charge-discharge operations for electrochemical cells intended for satellite power sources

CHARGE DISTRIBUTION↗

Calibration-interval adjustment indicator - A concept

Circuit, when used with decision table, permits relatively unskilled personnel to maintain effective quality control. Design determines required changes in calibration intervals. Interval readings are recorded to nearest integer, making high precision unnecessary. Specific required performance-history information is discussed.

Hedene, P. S.↗

Mechanisms of oxidation in the Co-Cr system.

Oxidation has been studied both as a function of temperature in the range from 900 to 1300 C and of the partial pressure of oxygen in the range from 0.05 to 760 torr. In addition, microstructures of oxide scales have been studied and characterized in more detail utilizing metallographic and X-ray techniques combined with electron microprobe analysis. The parabolic rate constants in 1100 C and at 100 and 10 torr oxygen are presented in a graph as a function of chromium content. Three main different mechanisms of oxidation in the Co-Cr system have been identified. In two of these, the rate determining process controlling the oxidation is the solid state diffusion of cobalt through the oxide CoO. The rate controlling process governing the oxidation for the third mechanism is chromium diffusion in dichromium trioxide.

Kofstad, P. K.↗