Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Positron Emission Tomography in Water Resources and Subsurface Energy Resources Engineering Research

Recent studies have demonstrated that positron emission tomography (PET) is a valuable tool for in-situ characterization of fluid transport in porous and fractured geologic media at the laboratory scale. While PET imaging is routinely used for clinical cancer diagnosis and preclinical medical research—and therefore imaging facilities are available at most research institutes—widespread adoption for applications in water resources and subsurface energy resources engineering have been limited by real and perceived challenges of working with this technique. In this study we discuss and address these challenges, and provide detailed analysis highlighting how positron emission tomography can complement and improve laboratory characterization of different subsurface fluid transport problems. The physics of PET are reviewed to provide a fundamental understanding of the sources of noise, resolution limits, and safety considerations. We then layout the methodology required to perform laboratory experiments imaged with PET, including a new protocol for radioactivity dosing optimization for imaging in geologic materials. Signal-to-noise and sensitivity analysis comparisons between PET and clinical X-ray computed tomography are performed to highlight how PET data can complement more traditional characterization methods, particularly for solute transport problems. Lastly, prior work is critically reviewed and discussed to provide a better understanding of the strengths and weakness of PET and how to best utilize PET-derived data for future studies.

02 PETROLEUM↗

Convergence of hepcidin deficiency, systemic iron overloading, heme accumulation, and REV-ERBα/β activation in aryl hydrocarbon receptor-elicited hepatotoxicity

Persistent aryl hydrocarbon receptor (AhR) agonists elicit dose-dependent hepatic lipid accumulation, oxidative stress, inflammation, and fibrosis in mice. Iron (Fe) promotes AhR-mediated oxidative stress by catalyzing reactive oxygen species (ROS) production. To further characterize the role of Fe in AhR-mediated hepatotoxicity, male C57BL/6 mice were orally gavaged with sesame oil vehicle or 0.01–30 μg/kg 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) every 4 days for 28 days. Duodenal epithelial and hepatic RNA-Seq data were integrated with hepatic AhR ChIP-Seq, capillary electrophoresis protein measurements, and clinical chemistry analyses. TCDD dose-dependently repressed hepatic expression of hepcidin (Hamp and Hamp2), the master regulator of systemic Fe homeostasis, resulting in a 2.6-fold increase in serum Fe with accumulating Fe spilling into urine. Total hepatic Fe levels were negligibly increased while transferrin saturation remained unchanged. Furthermore, TCDD elicited dose-dependent gene expression changes in heme biosynthesis including the induction of aminolevulinic acid synthase 1 (Alas1) and repression of uroporphyrinogen decarboxylase (Urod), leading to a 50% increase in hepatic hemin and a 13.2-fold increase in total urinary porphyrins. Consistent with this heme accumulation, differential gene expression suggests that heme activated BACH1 and REV-ERBα/β, causing induction of heme oxygenase 1 (Hmox1) and repression of fatty acid biosynthesis, respectively. Collectively, these results suggest that Hamp repression, Fe accumulation, and increased heme levels converge to promote oxidative stress and the progression of TCDD-elicited hepatotoxicity. - Highlights: • TCDD represses hepatic hepcidin expression, leading to systemic iron overloading. • Dysregulation of heme biosynthesis is consistent with heme and porphyrin accumulation. • Heme-activated REV-ERBα/β repress circadian-regulated hepatic lipid metabolism. • Disruption of iron homeostasis promotes TCDD-elicited steatohepatitis with fibrosis.

60 APPLIED LIFE SCIENCES↗

SU-F-T-10: Validation of ELP Dosimetry Using PRESAGE Dosimeter: Feasibility Test and Practical Considerations

Purpose: To validate the use of a PRESAGE dosimeter as a method to quantitatively measure dose distributions of injectable brachytherapy based on elastin-like polypeptide (ELP) nanoparticles. PRESAGE is a solid, transparent polyurethane-based dosimeter whose dose is proportional to a change in optical density, making it useful for visualizing the dose from a radionuclide-tagged-ELP injection. Methods: A PRESAGE dosimeter was designed to simulate an ELP injection. To calibrate, cuvette samples from the batch of PRESAGE were exposed to varying levels of radiation from 0–35.9Gy applied via a linear accelerator, then placed into a spectrophotometer to obtain the optical density change as a function of dose. A pre-optical-CT scan was acquired of the phantom to obtain a baseline tomographic optical density. A 1cc saline solution of I-125 tagged-ELP with and activity concentration of 1mCi/cc was injected into the phantom and left for five days. After five days, the ELP was removed and the cavity cleaned of all remaining radioactive material. Post tomographic optical images were acquired to obtain a differential optical density dataset. Results: Initial results after the 5-day exposure revealed an opaque white film that resembled the volume of the ELP solution injected into the phantom. We think this is possibly due to the saline solution diffusing into the PRESAGE and causing a change in the index of refraction at this shallow depth. Therefore, initially the optical scanner yielded inconclusive results. After several more days, the saline seemed to have evaporated out of the injection site and the ELP dose distribution was visible via color change in the dosimeter. Conclusion: We have created the first experimental design to measure the dose distribution of I-125-tagged-ELP. The PRESAGE formulation proves to be a feasible option for such measurements. Future experimental measurements need to be obtained to further characterize ELP dosimetry.

60 APPLIED LIFE SCIENCES↗

A Comparison of Model Calculation and Measurement of Absorbed Dose for Proton Irradiation

With the increase in the amount of time spent EVA that is necessary to complete the construction and subsequent maintenance of ISS, it will become increasingly important for ground support personnel to accurately characterize the radiation exposures incurred by EVA crewmembers. Since exposure measurements cannot be taken within the organs of interest, it is necessary to estimate these exposures by calculation. To validate the methods and tools used to develop these estimates, it is necessary to model experiments performed in a controlled environment. This work is such an effort. A human phantom was outfitted with detector equipment and then placed in American EMU and Orlan-M EVA space suits. The suited phantom was irradiated at the LLUPTF with proton beams of known energies. Absorbed dose measurements were made by the spaceflight operational dosimetrist from JSC at multiple sites in the skin, eye, brain, stomach, and small intestine locations in the phantom. These exposures are then modeled using the BRYNTRN radiation transport code developed at the NASA Langley Research Center, and the CAM (computerized anatomical male) human geometry model of Billings and Yucker. Comparisons of absorbed dose calculations with measurements show excellent agreement. This suggests that there is reason to be confident in the ability of both the transport code and the human body model to estimate proton exposure in ground-based laboratory experiments.

Zapp, N.↗

Radiation: Physical Characterization and Environmental Measurements

In this session, Session WP4, the discussion focuses on the following topics: Production of Neutrons from Interactions of GCR-Like Particles; Solar Particle Event Dose Distributions, Parameterization of Dose-Time Profiles; Assessment of Nuclear Events in the Body Produced by Neutrons and High-Energy Charged Particles; Ground-Based Simulations of Cosmic Ray Heavy Ion Interactions in Spacecraft and Planetary Habitat Shielding Materials; Radiation Measurements in Space Missions; Radiation Measurements in Civil Aircraft; Analysis of the Pre-Flight and Post-Flight Calibration Procedures Performed on the Liulin Space Radiation Dosimeter; and Radiation Environment Monitoring for Astronauts.

Source record↗

Modulation of lens cell adhesion molecules by particle beams

Cell adhesion molecules (CAMs) are proteins which anchor cells to each other and to the extracellular matrix (ECM), but whose functions also include signal transduction, differentiation, and apoptosis. We are testing a hypothesis that particle radiations modulate CAM expression and this contributes to radiation-induced lens opacification. We observed dose-dependent changes in the expression of beta 1-integrin and ICAM-1 in exponentially-growing and confluent cells of a differentiating human lens epithelial cell model after exposure to particle beams. Human lens epithelial (HLE) cells, less than 10 passages after their initial culture from fetal tissue, were grown on bovine corneal endothelial cell-derived ECM in medium containing 15% fetal bovine serum and supplemented with 5 ng/ml basic fibroblast growth factor (FGF-2). Multiple cell populations at three different stages of differentiation were prepared for experiment: cells in exponential growth, and cells at 5 and 10 days post-confluence. The differentiation status of cells was characterized morphologically by digital image analysis, and biochemically by Western blotting using lens epithelial and fiber cell-specific markers. Cultures were irradiated with single doses (4, 8 or 12 Gy) of 55 MeV protons and, along with unirradiated control samples, were fixed using -20 degrees C methanol at 6 hours after exposure. Replicate experiments and similar experiments with helium ions are in progress. The intracellular localization of beta 1-integrin and ICAM-1 was detected by immunofluorescence using monoclonal antibodies specific for each CAM. Cells known to express each CAM were also processed as positive controls. Both exponentially-growing and confluent, differentiating cells demonstrated a dramatic proton-dose-dependent modulation (upregulation for exponential cells, downregulation for confluent cells) and a change in the intracellular distribution of the beta 1-integrin, compared to unirradiated controls. In contrast, there was a dose-dependent increase in ICAM-1 immunofluorescence in confluent, but not exponentially-growing cells. These results suggest that proton irradiation downregulates beta 1-integrin and upregulates ICAM-1, potentially contributing to cell death or to aberrant differentiation via modulation of anchorage and/or signal transduction functions. Quantification of the expression levels of the CAMs by Western analysis is in progress.

NASA Discipline Radiation Health↗

Setup and Characterization of a 137 CS Dosimetry Calibration Source in a Space-constrained Environment

Proper characterization of 137 Cs sources used for dosimeter calibration and performance testing is crucial for accurate and precise knowledge of air kerma rate and delivered dose. A 269 GBq 137 Cs source was relocated to a new facility, which had a footprint of approximately 2.8 m × 3.6 m and a 3.4 m high ceiling. A small room size, such as in the new facility, may significantly increase backscatter from the walls or room return. Due to the limited source strength, a relatively close irradiation position of 1.00 m from the source was selected to decrease required exposure times. Proximity to the small but cylindrical source has the potential to alter the 1/r 2 relationship (inverse square law) of air kerma rate with distance associated with point sources. Practical tutorials concerning dosimetry irradiation facilities are largely absent from the archival literature. For those reasons, standard characterization experiments were repeated multiple times, great care was taken with positioning, several experiments were added to the standard ones, an ion chamber and dosimeters were used rather than film for greater accuracy and precision, and practical details of the process were recorded. The impacts of room size and finite source dimensions were quantified and mitigated by the efforts reported here. Finally, recommendations for simple but thorough facility characterization, beam calibration, and quality control resulted.

42 ENGINEERING↗

Characteristics of trapped proton anisotropy at Space Station Freedom altitudes

The ionizing radiation dose for spacecraft in low-Earth orbit (LEO) is produced mainly by protons trapped in the Earth's magnetic field. Current data bases describing this trapped radiation environment assume the protons to have an isotropic angular distribution, although the fluxes are actually highly anisotropic in LEO. The general nature of this directionality is understood theoretically and has been observed by several satellites. The anisotropy of the trapped proton exposure has not been an important practical consideration for most previous LEO missions because the random spacecraft orientation during passage through the radiation belt 'averages out' the anisotropy. Thus, in spite of the actual exposure anisotropy, cumulative radiation effects over many orbits can be predicted as if the environment were isotropic when the spacecraft orientation is variable during exposure. However, Space Station Freedom will be gravity gradient stabilized to reduce drag, and, due to this fixed orientation, the cumulative incident proton flux will remain anisotropic. The anisotropy could potentially influence several aspects of Space Station design and operation, such as the appropriate location for radiation sensitive components and experiments, location of workstations and sleeping quarters, and the design and placement of radiation monitors. Also, on-board mass could possible be utilized to counteract the anisotropy effects and reduce the dose exposure. Until recently only omnidirectional data bases for the trapped proton environment were available. However, a method to predict orbit-average, angular dependent ('vector') trapped proton flux spectra has been developed from the standard omnidirectional trapped proton data bases. This method was used to characterize the trapped proton anisotropy for the Space Station orbit (28.5 degree inclination, circular) in terms of its dependence on altitude, solar cycle modulation (solar minimum vs. solar maximum), shielding thickness, and radiation effect (silicon rad and rem dose).

Armstrong, T. W.↗

Adsorption of Methylene Blue, Brilliant Green and Rhodamine B from Aqueous Solution Using Collagen-g-p(AA-co-NVP)/Fe{sub 3}O{sub 4}@SiO{sub 2} Nanocomposite Hydrogel

In this study, the collagen-g-poly(acrylic acid-co-N-vinylpyrrolidone)/Fe{sub 3}O{sub 4}@SiO{sub 2} (collagen-g-p(AA-co-NVP)/Fe{sub 3}O{sub 4}@SiO{sub 2}) as magnetic nanocomposite hydrogel was synthesized by graft copolymerization of acrylic acid (AA) and N-vinylpyrrolidone (NVP) onto collagen in the presence of the Fe{sub 3}O{sub 4}@SiO{sub 2} using ammonium persulfate as a free radical initiator and bis[2-(methacryloyloxy)ethyl] phosphate as a crosslinker under ultrasound-assisted condition. The blank collagen-g-p(AA-co-NVP) hydrogel and its composite with the Fe{sub 3}O{sub 4}@SiO{sub 2} nanoparticles were characterized by means of FTIR, SEM-EDS, XRD, VSM and TGA methods. The effects of different parameters such as pH, dose of adsorbent and time on swelling behavior were examined. The swelling ratio of the collagen-g-p(AA-co-NVP) hydrogel increased in the presence of the Fe{sub 3}O{sub 4}@SiO{sub 2} nanoparticles. Adsorption behavior of magnetic nanocomposite hydrogel was investigated for the adsorption of dyes and it was found to remove about 93% for methylene blue, 96% for brilliant green and 89% for rhodamine B in 50 mg/L of dyes solutions at pH 7. Kinetic study revealed the applicability of pseudo-first-order and pseudo-second-order models for the adsorption of mentioned dyes. The adsorption isotherm was studied in 25, 35, 45 and 55 °C using Langmuir, Freundlich, Temkin and Sips models and the adsorption data were well described by Langmuir isotherm model. Negative values of ΔG{sup º} for all three dyes suggested the feasibility of dyes removal and support for spontaneous adsorption of mentioned dyes on magnetic nanocomposite hydrogel. Desorption of dyes from the dye loaded nanocomposite hydrogel was simply done in ethanol. The results indicate that the prepared magnetic nanocomposite hydrogel is an efficient adsorbent with high adsorption capacity for the aforementioned dyes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Multiscale characterization of irradiation behaviour of ion-irradiated SiC/SiC composites

Here, the irradiation tolerance of SiC/SiC composites was studied using 10 MeV Au ion irradiations at 350 °C, for surface doses between 1 and 50 displacements per atom (dpa). Atomic force microscopy and optical profilometry revealed irradiation-induced axial and radial shrinkage of SiC-fibers. At 50 dpa, net fiber shrinkage reached 2.8 ± 0.3%. We conclude that the primary cause of SiC-fiber shrinkage in SiC/SiC composites is the irradiation-induced loss of pre-existing carbon packets, which had occupied 2–3% fiber volume in unirradiated state. A compelling evidence of the carbon packet loss was revealed using a combination of state-of-art conventional transmission electron microscopy (TEM), high resolution TEM, energy-filtered TEM and electron energy loss spectroscopy. Additionally, the carbon packet volume fraction decreased with increasing dose, reaching near-complete loss after 50 dpa. Carbon packet loss was further confirmed using Raman spectroscopy where the carbon D and G peaks disappeared after irradiation. In contrast, irradiation-induced swelling of 1 ± 0.5% was observed in the matrix after 50 dpa. The study also shows that up to 50 dpa, the multilayer pyrolytic-carbon (PyC) interface in the composite is highly irradiation tolerant as it maintained its morphology, graphitic nature and showed no signs of amorphization. Additionally, Raman spectroscopy revealed a saturation of TEM invisible disorder at 1 dpa for both ultra-fine grains of the fiber and the larger SiC-matrix grains. However, TEM visible extended defect formation such as dislocation loops were only detected in the larger matrix grains, thereby revealing a potential role of grain size on defect accumulation in SiC.

36 MATERIALS SCIENCE↗

A neutron fluence map of the Los Alamos National Laboratory Godiva IV critical assembly

A neutron fluence map and a total ionizing dose map of the Los Alamos National Laboratory Godiva IV fast burst critical assembly was generated using passive reactor dosimetry, comprised of sulfur pellets and thermoluminescent dosimeters. Godiva IV is an unmoderated, fast burst, critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5 % molybdenum for strength. The mapping was performed during a single 75.6 ºC temperature rise burst operation, with the top and sides of the cylindrical Godiva-IV Top Hat covered in passive dosimetry. Dosimetry was placed in a symmetric pattern around the Top Hat, with higher concentrations near the control rods and burst rod. A specific portion of the lower quadrant of the burst rod was mapped to confirm a testing region where the neutron fluence varied by no more than ± 5%. The results will be used to assess the neutron, gamma, and total ionizing dose environment in three-dimensional space around the assembly for higher fidelity experiment placement, active dosimetry positioning, and radiation field characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of simultaneous thermal/gamma radiation aging of cross-linked polyethylene (XLPE) insulation—interim status report

Cross-linked polyethylene (XLPE) is the most common cable insulation found in nuclear containment, and is therefore a priority material for investigation of long term aging effect from elevated temperature combined with gamma radiation exposure. Prior work has identified the possibility of anomalous aging behavior in XLPE such as the inverse temperature effect in which radiation exposure is more damaging at lower temperatures than at higher temperatures. We explored simultaneous aging of XLPE insulation from modern Firewall® III nuclear cables at 60, 90, and 115 °C, at gamma dose rates from 116 to 540 Gy/h, for exposure periods up to 25 d. XLPE samples exposed in this way were characterized using the percent gel and uptake factor method. For the conditions and material examine, degradation behavior was seen to track proportionally with increasing temperature, rather than to exhibit greater degradation at lower temperatures. Ongoing work including similar aging at 25 °C and characterization of the XLPE samples using other methods will further elucidate these initial results

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of colorless polyimide film for thermal control coating applications

A series of essentially colorless aromatic polyimide films was synthesized and characterized with the objective of obtaining maximum optical transparency for applications in space. Optical transparency is a requirement for high performance polymeric films used in second surface mirror coatings on thermal control systems. The intensity in color of aromatic polyimide films was lowered by reducing the electronic interaction between chromophoric centers in the polymer molecular structure and by using highly purified monomers. The resulting lightly colored to colorless polyimide films were characterized by UV-visible and infrared spectroscopy before and after exposure to 300 equivalent solar hours UV irradiation and varying doses of 1 MeV electron irradiation. After irradiation, the films were found to be 2 to 2.5 times more transparent than commercial polyimide film of the same thickness.

St.clair, A. K.↗

Evaluation of colorless polyimide film for thermal control coating applications

A series of essentially colorless aromatic polyimide films was synthesized and characterized with the objective of obtaining maximum optical transparency for applications in space. Optical transparency is a requirement for high performance polymeric films used in second surface mirror coatings on thermal control systems. The intensity in color of aromatic polyimide films was lowered by reducing the electronic interaction between chromophoric centers in the polymer molecular structure and by using highly purified monomers. The resulting lightly colored to colorless polyimide films were characterized by UV-visible and infrared spectroscopy before and after exposure to 300 equivalent solar hours UV irradiation and varying doses of 1 MeV electron irradiation. After irradiation, the films were found to be 2 to 2.5 times more transparent than commercial polyimide film of the same thickness.

St. Clair, A. K.↗

Evaluation of colorless polyimide film for thermal control coating applications

A series of essentially colorless aromatic polyimide films has been synthesized and characterized with the objective of obtaining maximum optical transparency for applications in space. Optical transparency is a requirement for high performance polymeric films used in second surface mirror coatings on thermal control systems. The intensity in color of aromatic polyimide films was lowered by reducing the electronic interaction between chromophoric centers in the polymer molecular structure and by using highly purified monomers. The resulting lightly colored to colorless polyimide films have been characterized by UV-visible and infrared spectroscopy before and after exposure to 300 equivalent solar hours UV irradiation and varying doses of 1 MeV electron irradiation. After irradiation, the films were found to be 2 to 2.5 times more transparent than commercial polyimide film of the same thickness.

St. Clair, A. K.↗

Optical Transmission Characterization of Fused Silica Materials Irradiated at the CERN Large Hadron Collider

The Target Absorbers for Neutrals (TANs) represent one of the most radioactive regions in the Large Hadron Collider (LHC). Seven 40 cm long fused silica rods with different dopant specifications, manufactured by Heraeus, were irradiated in one of the TANs located around the ATLAS experiment by the Beam RAte of Neutrals (BRAN) detector group. This campaign took place during the Run 2 p+p data taking, which occurred between 2016 and 2018. This paper reports a complete characterization of optical transmission per unit length of irradiated fused silica materials as a function of wavelength (240 nm - 1500 nm), dose (up to 18 MGy), and level of OH and H$_2$ dopants introduced in the manufacturing process. The dose delivered to the rods was estimated using Monte Carlo simulations performed by the CERN FLUKA team.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-202: Secondary Radiation Measurements for Charged Particle Therapy Monitoring: Fragmentation of Therapeutic He, C and O Ion Beams Impinging On a PMMA Target

Purpose: In Charged Particle Therapy (CPT), besides protons, there has been recently a growing interest in 4He, 12C and 16O beams. The secondary radiation produced in the interaction of those beams with a patient could be potentially used for on-line monitoring of range uncertainties in order to fully exploit the advantages of those light ions resulting from increased Radio Biological Effectiveness, reduced multiple scattering and Oxygen Enhancement Ratio. The study and precise characterization of secondary radiation (beta+, prompt gamma, charged fragments) is the cornerstone of any R&D activity aiming for online monitoring development and purpose of the analysis presented here. Methods: We present the measurements of the secondary radiation generated by He, C and O beams impinging on a beam stopping PMMA target. The data has been collected at the Heidelberg Ionbeam Therapy center (HIT), where several millions of collisions were recorded at different energies, relevant for therapeutical applications. Results: The experimental setup, as well as the analysis strategies will be reviewed. The detected particle fluxes as a function of the primary beam energy and the emission angle with respect to the beam direction will be presented and compared to the results of other available measurements. In addition, the energy spectra and emission shapes of charged secondary particles will be shown and discussed in the context of the primary beam range monitoring technique that is being developed by the ARPG collaboration, within the INSIDE project funded by the Italian research ministry. The implications for dose monitoring applications will be discussed, in the context of the current (or planned) state-of- the-art detector solutions. Conclusion: The characterization of the radiation produced by 12C, 4He and 16O beams fully supports the feasibility of on-line range monitoring in the clinical practice of CPT by means of secondary particles detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In Situ Characterization of the Initial Effect of Water on Molecular Interactions at the Interface of Organic/Inorganic Hybrid Systems

Probing initial interactions at the interface of hybrid systems under humid conditions has the potential to reveal the local chemical environment at solid/solid interfaces under real-world, technologically relevant conditions. Here in this paper, we show that ambient pressure X-ray photoelectron spectroscopy (APXPS) with a conventional X-ray source can be used to study the effects of water exposure on the interaction of a nanometer-thin polyacrylic acid (PAA) layer with a native aluminum oxide surface. The formation of a carboxylate ionic bond at the interface is characterized both with APXPS and in situ attenuated total reflectance Fourier transform infrared spectroscopy in the Kretschmann geometry (ATR-FTIR Kretschmann). When water is dosed in the APXPS chamber up to 5 Torr (~28% relative humidity), an increase in the amount of ionic bonds at the interface is observed. To confirm our APXPS interpretation, complementary ATR-FTIR Kretschmann experiments on a similar model system, which is exposed to an aqueous electrolyte, are conducted. These spectra demonstrate that water leads to an increased wet adhesion through increased ionic bond formation.

36 MATERIALS SCIENCE↗