Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Spectrometer-free quantitative vapor sensing and classification via spatiotemporal imaging of porous silicon metasurfaces

Metasurfaces offer a compact platform for optical vapor sensing, but their practical deployment has been limited by weak evanescent light–matter interactions and reliance on spectrally resolved instrumentation. Here, we report porous silicon (pSi) metasurfaces for spectrometer-free quantitative detection of volatile organic compounds (VOCs) with strongly enhanced light–matter interaction. The engineered porosity increases sensitivity by >100× relative to non-porous dielectric metasurfaces, enabling limits of detection of 1.65 ppm for methanol and 9.1 ppm for ethanol across a broad dynamic range (<10 ppm to >103 ppm). Imaging-based readout provides a lightweight, spectrometer-free pathway for real-time quantitative sensing. Beyond quantitative detection, the mesoporous architecture introduces adsorption–desorption kinetics as an additional information channel. Analysis of the resulting spatiotemporal signatures enables kinetic fingerprinting without reliance on infrared spectral features or surface functionalization, and a lightweight machine-learning classifier differentiates acetone, methanol, ethanol, and isopropanol with 91.6% accuracy. These results establish porous metasurfaces as spatiotemporal sensing elements that couple quantitative vapor detection with kinetic fingerprinting through real-time dynamical responses, enabling low-cost, high-performance optical sensors.

Dash, Tomoshree [Clemson University]↗

Spectroscopic features of dissolved iodine in pristine and gamma-irradiated nitric acid solutions

While iodine speciation is important for a wide range of nuclear activities, understanding the mechanisms of the transformations of iodine between chemical forms and the sensitivity of these transitions to solution conditions and exposure to radiation remains an active area of research. This work curates spectroscopic data from several experimental techniques and establishes their sensitivity and limitations in detecting changes in iodine speciation in both neutral and acidic regimes. The techniques include Raman spectroscopy, Fourier Transform Infrared (FTIR) spectroscopy, 127 I NMR spectroscopy, and ultraviolet-visible (UV-Vis) spectroscopy. Analysis of these data indicates that these commonly accessible spectroscopies often have dynamic ranges of measurable concentrations that do not always overlap between all techniques. The experimental techniques are disparately sensitive to iodide (I - ), molecular iodine (I 2 ), iodate (IO 3 - ), and periodate (IO 4 - ) species. Raman, FTIR, and NMR spectra were subsequentially analyzed using two-dimensional correlation analyses to generate high-resolution autocorrelation spectra. Here, the use of these spectroscopies is then extended to tracking acidification-induced and gamma irradiation-induced transformations of dissolved sodium iodate in deionized water and concentrated nitric acid. Both dissolution into nitric acid and irradiation with a gamma source are demonstrated to perturb the iodine speciation promoting their assembly into molecular iodine (I 2 ) and/or triiodide (I 3 - ). While I 2 and I 3 - species are undetectable with FTIR spectroscopy and 127 I NMR spectroscopy, the species can be detected with UV-Vis spectroscopy, and in some instances, I 3 - can be detected with Raman spectroscopy in the low wavenumber region. Ultimately, the results of this work provide a path to designing optimal combinations of techniques to detect forms of iodine across a wide range of concentrations and conditions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A general strategy to construct small molecule biosensors in eukaryotes

Biosensors for small molecules can be used in applications that range from metabolic engineering to orthogonal control of transcription. Here, we produce biosensors based on a ligand-binding domain (LBD) by using a method that, in principle, can be applied to any target molecule. The LBD is fused to either a fluorescent protein or a transcriptional activator and is destabilized by mutation such that the fusion accumulates only in cells containing the target ligand. We illustrate the power of this method by developing biosensors for digoxin and progesterone. Addition of ligand to yeast, mammalian, or plant cells expressing a biosensor activates transcription with a dynamic range of up to ~100-fold. We use the biosensors to improve the biotransformation of pregnenolone to progesterone in yeast and to regulate CRISPR activity in mammalian cells. This work provides a general methodology to develop biosensors for a broad range of molecules in eukaryotes.

59 BASIC BIOLOGICAL SCIENCES↗

Small molecule biosensors

Biosensors for small molecules can be used in applications that range from metabolic engineering to orthogonal control of transcription. Biosensors are produced based on a ligand-binding domain (LBD) using a method that, in principle, can be applied for any target molecule. The LBD is fused to either a fluorescent protein or a transcriptional activator and is destabilized by mutation such that the fusion accumulates only in cells containing the target ligand. The power of this method is illustrated by developing biosensors for digoxin and progesterone. Addition of ligand to cells expressing a biosensor activates transcription in yeast, mammalian cells and plants, with a dynamic range of up to about 100-fold or more. The biosensors are used to improve the biotransformation of pregnenolone to progesterone in yeast and to regulate CRISPR activity in mammalian cells. This work provides a general methodology to develop biosensors for a broad range of molecules.

Mandell, Daniel J.↗

Cryogenic loss monitors with FPGA TDC signal processing

Radiation hard helium gas ionization chambers capable of operating in vacuum at temperatures ranging from 5K to 350K have been designed, fabricated and tested and will be used inside the cryostats at Fermilab's Superconducting Radiofrequency beam test facility. The chamber vessels are made of stainless steel and all materials used including seals are known to be radiation hard and suitable for operation at 5K. The chambers are designed to measure radiation up to 30 kRad/hr with sensitivity of approximately 1.9 pA/(Rad/hr). The signal current is measured with a recycling integrator current-to-frequency converter to achieve a required measurement capability for low current and a wide dynamic range. A novel scheme of using an FPGA-based time-to-digital converter (TDC) to measure time intervals between pulses output from the recycling integrator is employed to ensure a fast beam loss response along with a current measurement resolution better than 10-bit. This paper will describe the results obtained and highlight the processing techniques used.

36 MATERIALS SCIENCE↗

HO x radical chemistry in oxidation flow reactors with low-pressure mercury lamps systematically examined by modeling

Oxidation flow reactors (OFRs) using OH produced from low-pressure Hg lamps at 254 nm (OFR254) or both 185 and 254 nm (OFR185) are commonly used in atmospheric chemistry and other fields. OFR254 requires the addition of externally formed O 3 since OH is formed from O 3 photolysis, while OFR185 does not since O 2 can be photolyzed to produce O 3 , and OH can also be formed from H 2 O photolysis. In this study, we use a plug-flow kinetic model to investigate OFR properties under a very wide range of conditions applicable to both field and laboratory studies. We show that the radical chemistry in OFRs can be characterized as a function of UV light intensity, H 2 O concentration, and total external OH reactivity (OHR ext , e.g., from volatile organic compounds (VOCs), NO x , and SO 2 ). OH exposure is decreased by added external OH reactivity. OFR185 is especially sensitive to this effect at low UV intensity due to low primary OH production. OFR254 can be more resilient against OH suppression at high injected O 3 (e.g., 70 ppm), as a larger primary OH source from O 3 , as well as enhanced recycling of HO 2 to OH, make external perturbations to the radical chemistry less significant. However if the external OH reactivity in OFR254 is much larger than OH reactivity from injected O 3 , OH suppression can reach 2 orders of magnitude. For a typical input of 7 ppm O 3 (OHR O 3 = 10 s −1 ), 10-fold OH suppression is observed at OHR ext ~ 100 s −1 , which is similar or lower than used in many laboratory studies. The range of modeled OH suppression for literature experiments is consistent with the measured values except for those with isoprene. The finding on OH suppression may have important implications for the interpretation of past laboratory studies, as applying OH exp measurements acquired under different conditions could lead to over a 1-order-of-magnitude error in the estimated OH exp . The uncertainties of key model outputs due to uncertainty in all rate constants and absorption cross-sections in the model are within ±25 % for OH exposure and within ±60 % for other parameters. These uncertainties are small relative to the dynamic range of outputs. Uncertainty analysis shows that most of the uncertainty is contributed by photolysis rates of O 3 , O 2 , and H 2 O and reactions of OH and HO 2 with themselves or with some abundant species, i.e., O 3 and H 2 O 2 . OH exp calculated from direct integration and estimated from SO 2 decay in the model with laminar and measured residence time distributions (RTDs) are generally within a factor of 2 from the plug-flow OH exp . However, in the models with RTDs, OH exp estimated from SO 2 is systematically lower than directly integrated OH exp in the case of significant SO 2 consumption. We thus recommended using OH exp estimated from the decay of the species under study when possible, to obtain the most appropriate information on photochemical aging in the OFR. Using HO x -recycling vs. destructive external OH reactivity only leads to small changes in OH exp under most conditions. Changing the identity (rate constant) of external OH reactants can result in substantial changes in OH exp due to different reductions in OH suppression as the reactant is consumed. We also report two equations for estimating OH exposure in OFR254. We find that the equation estimating OH exp from measured O 3 consumption performs better than an alternative equation that does not use it, and thus recommend measuring both input and output O 3 concentrations in OFR254 experiments. This study contributes to establishing a firm and systematic understanding of the gas-phase HO x and O x chemistry in these reactors, and enables better experiment planning and interpretation as well as improved design of future reactors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical Synchrotron Radiation Beam Imaging with a Digital Mask

We have applied a new imaging/optical masking technique, which employs a digital micro-mirror device (DMD) and optical synchrotron radiation (OSR), to perform high dynamic range (DR) beam imaging at the JLAB Energy Recovery Linac and the SLAC/SPEAR3 Synchrotron Light Source. The OSR from the beam is first focused onto the DMD to produce a primary image; selected areas of this image are spatially filtered by controlling the state of individual micro-mirrors; and finally, the filtered image is refocused onto a CCD camera. At JLAB this technique has been used successfully to view the beam halo with a DR ~ 105. At SPEAR3 the DMD was used to filter out the bright core of the stored beam to study the turn-by-turn dynamics of the 10-3 weaker injected beam. We describe the optical performance, present limitations and our plans to improve the DR of both experimental systems.

43 PARTICLE ACCELERATORS↗

An in-vacuum x-ray diffraction microscope for use in the 0.7-2.9 keV range

A dedicated in-vacuum coherent x-ray diffraction microscope was installed at the 2-ID-B beamline of the Advanced Photon Source for use with 0.7-2.9 keV x-rays. The instrument can accommodate three common implementations of diffractive imaging; plane wave illumination; defocused-probe (Fresnel diffractive imaging) and scanning (ptychography) using either a pinhole, focused or defocused probe. The microscope design includes active feedback to limit motion of the optics with respect to the sample. Upper bounds on the relative optics-to-sample displacement have been measured to be 5.8 nm(v) and 4.4 nm(h) rms/h using capacitance micrometry and 27 nm/h using x-ray point projection imaging. The stability of the measurement platform and in-vacuum operation allows for long exposure times, high signal-to-noise and large dynamic range two-dimensional intensity measurements to be acquired. Finally, we illustrate the microscope's stability with a recent experimental result.

43 PARTICLE ACCELERATORS↗

Evaluation of a lithium formate EPR dosimetry system for dose measurements around {sup 192}Ir brachytherapy sources

A dosimetry system using lithium formate monohydrate (HCO{sub 2}Li{center_dot}H{sub 2}O) as detector material and electron paramagnetic resonance (EPR) spectroscopy for readout has been used to measure absorbed dose distributions around clinical {sup 192}Ir sources. Cylindrical tablets with diameter of 4.5 mm, height of 4.8 mm, and density of 1.26 g/cm{sup 3} were manufactured. Homogeneity test and calibration of the dosimeters were performed in a 6 MV photon beam. {sup 192}Ir irradiations were performed in a PMMA phantom using two different source models, the GammaMed Plus HDR and the microSelectron PDR-v1 model. Measured absorbed doses to water in the PMMA phantom were converted to the corresponding absorbed doses to water in water phantoms of dimensions used by the treatment planning systems (TPSs) using correction factors explicitly derived for this experiment. Experimentally determined absorbed doses agreed with the absorbed doses to water calculated by the TPS to within {+-}2.9%. Relative standard uncertainties in the experimentally determined absorbed doses were estimated to be within the range of 1.7%-1.3% depending on the radial distance from the source, the type of source (HDR or PDR), and the particular absorbed doses used. This work shows that a lithium formate dosimetry system is well suited for measurements of absorbed dose to water around clinical HDR and PDR {sup 192}Ir sources. Being less energy dependent than the commonly used thermoluminescent lithium fluoride (LiF) dosimeters, lithium formate monohydrate dosimeters are well suited to measure absorbed doses in situations where the energy dependence cannot easily be accounted for such as in multiple-source irradiations to verify treatment plans. Their wide dynamic range and linear dose response over the dose interval of 0.2-1000 Gy make them suitable for measurements on sources of the strengths used in clinical applications. The dosimeter size needs, however, to be reduced for application to single-source dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Linear Viscoelastic Properties of Putative Cyclic Polymers Synthesized by Reversible Radical Recombination Polymerization (R3P)

Linear viscoelastic properties in both melt and solution states are reported for a series of poly(3,6-dioxa-1,8-octanedithiol) (polyDODT) made by reversible radical recombination polymerization (R 3 P) under conditions designed to produce linear (LDODT), cyclic (RDODT) and linear-cyclic mixtures (LRDODT). PolyDODT is amorphous (T g < -50 °C) and highly flexible (entanglement molecular weight M e,lin ≈ 1850 g/mol for LDODT). PolyDODT’s low T g and low M e,lin enable characterization over a wide dynamic range and a wide range of dimensionless weight-average molecular weight Z w = M w /M e,lin . Measurements at temperatures from -57 °C to 100 °C provide up to 18 deades of reduced frequency, which is necessary to characterize RDODT melts with Z w from 23 to 300. The two highest molecular weight polymers in the present RDODT series have such high M w (406k and 556k g/mol) that mass spectrometry, NMR spectroscopy, and even chemical assays for chain ends are unable to rule out up to 2 mol% linear contaminant. By studying the samples in solution (using dilution to reduce Z w ) we could compare their dynamics with those of previously established high-purity polystyrene (PS) rings (limited to Z w ≤ 13.6). RDODT solutions with Z w < 15 (concentrations <5wt% for RDODT-406k and 556k) have dynamic moduli G^* that accord with LCCC-purified PS rings in terms of the frequency dependence (including the absence of a plateau), the progression of shapes of G* as a function of Z w , and the linear scaling of their zero-shear viscosity η0 with M w . The shape of G* as a function of Z w for solutions of RDODT-406k and -556k also accord with lower M w RDODT melts (which have ≤ 1.3mol% linear contaminant). Thus, measurement of the linear viscoelastic properties of appropriate concentrations of high M w (>200k g/mol) putative cyclic polymers, in which linear chains evade spectroscopic detection, may provide an alternative means (though not fully proven) of validation of sample purity. When Z w > 15 (including all seven RDODT melts and eight of their solutions), G* has a rubbery plateau. This suggests that the onset of entanglement-like behavior in rings requires 4-5-fold greater Z w than is required for linear chains. Further, the plateau moduli of RDODT samples are indistinguishable from G N o of the corresponding LDODT (melt or matched-concentration solutions). In entangled linear polymers, the observation that G N o is independent of Z w follows from limitations on lateral fluctuations due to neighboring chains becoming independent of position along a given chain. The present results for RDODT suggest that this holds for sufficiently long endless chains, too. While the RDODT have the same G N o as entangled LDODT, when Z w > 60 the terminal relaxation, if reached at all, of RDODT extends to orders of magnitude lower frequency than an entangled linear polymer of the same Z w . Consequently, the viscosity of RDODT with Z w > 60 increases with Z w much more strongly than the 3.4-power observed for entangled linear polymers. Lastly, these novel polymers, with disulfide-linked backbone and broad relaxation time distribution may prove important in relation to biodegradable elastomers and materials with exceptional low-frequency dissipation, extending at least 12 decades below the onset of the rubbery plateau.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Momentum-Space Observation of Optically Excited Nonthermal Electrons in Graphene with Persistent Pseudospin Polarization

The unique optical properties of graphene, with broadband absorption and ultrafast response, make it a critical component of optoelectronic and spintronic devices. Using time-resolved momentum microscopy with high data rate and high dynamic range, we report momentum-space measurements of electrons promoted to the graphene conduction band with visible light and their subsequent relaxation. Here, we observe a pronounced nonthermal distribution of nascent photoexcited electrons with lattice pseudospin polarization in remarkable agreement with results of simple tight-binding theory. By varying the excitation fluence, we vary the relative importance of electron-electron vs electron-phonon scattering in the relaxation of the initial distribution. Increasing the excitation fluence results in increased noncollinear electron-electron scattering and reduced pseudospin polarization, although up-scattered electrons retain a degree of polarization. These detailed momentum-resolved electron dynamics in graphene demonstrate the capabilities of high-performance time-resolved momentum microscopy in the study of 2D materials and can inform the design of graphene devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Shadowgraphy and X-Ray Phase Contrast Methods for Characterizing a DT Ice Layer in an Inertial Confinement Fusion Target

Shadowgraphy and x-ray phase contrast (XPC) imaging are two techniques that are used for characterizing the deuterium-tritium ice layer in Inertial Confinement Fusion targets. Each technique has limitations that affect how accurately they can characterize small crystalline defects and measure the ice-thickness non-uniformities that may be only a few micrometers in height. The concern is that shadowgraphy may be overly sensitive to the shape and depth of defects in the surface and insufficiently sensitive to the shape of longer-wavelength roughness, while x-ray phase contrast may be too insensitive to defects in the ice surface. Multiple ice layers with different thicknesses (40 to 63 μm), thickness uniformities (peak-valley variations that range from <2- to 12 μm), and crystal defects were analyzed using shadowgraphy and x-ray phase contrast techniques. The results from each method agree when the ice layer is uniformly thick and the crystal lacks defects. That agreement worsens as the number of defects in the surface of the ice layer increases and the roughness that is determined from a shadowgram image of the target’s limb is greater than can be justified by the number of defects that are seen in the target’s front and rear surfaces. The XPC technique is considerably less sensitive to surface defects, in part due to the poorer dynamic range and image resolution compared to shadowgraphy. Localized regions of the ice layer that are thicker or thinner than the average thickness of the layer are reported by shadowgraphy to be smaller in height and footprint (by up to 30%) than by XPC. As a result, the two techniques report different ice layer thicknesses that can vary by up to 10%. Shadowgraphy results from two caustics that trace different paths through the target, and, in theory, image the same ice-vapor surface (but reflect from either the vapor or ice side of the interface) did not consistently characterize the size or shape of ice features to be the same magnitude. Here, the XPC technique provides the best assessment of low-mode (l < 7) roughness in the ice layer. Shadowgraphy results using the strongest caustic is best for detecting the presence of grooves in the ice, though not for quantifying the size of them. If multiple grooves are present it is best to discard and reform the ice layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Morphological Properties of the Crab Nebula: A Detailed Multiwavelength Study Based on New VLA, HST, Chandra, and XMM-Newton Images

We present a detailed analysis of the morphological properties of the Crab Nebula across the electromagnetic spectrum based on new and previous high-quality data from radio to X-rays. In the radio range we obtained an image of the entire nebula at 3 GHz with subarcsecond angular resolution using the VLA (NRAO) and an image at 100 GHz of the central region using the ALMA array. Simultaneously with the VLA observations we performed HST WFPC3 near-infrared (λ∼1.5 μm) and Chandra X-ray (0.5–8 keV band) observations of the central region of the nebula. In addition we produced a new UV image of the Crab Nebula at 291 nm by co-adding 75 individual exposures of the Optical-UV Monitor on board XMM-Newton. The high-angular resolution and high-dynamic range radio image at 3 GHz allowed us to improve the detection and characterization of peculiar morphological features including arches with foot brightening and intercrossed loop-like structures, likely originating in plasma confined to magnetic field lines. Based on the new radio image, we carried out a detailed multiwavelength correlation. In the central area, the comparison of the almost simultaneous images confirms that the wisps in the three spectral ranges do not generally coincide in location, the radio emission being the most discordant, which is suggestive of the existence of two different synchrotron components. The X-ray pulsar jet does not have a radio counterpart. Instead, another jet-like feature is seen in radio, though with different curvature and starting point.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of ocean glint and ozone absorption using LCROSS Earth observations

The Lunar CRater Observation and Sensing Satellite (LCROSS) observed the distant Earth on three occasions in 2009. These data span a range of phase angles, including a rare crescent phase view. For each epoch, the satellite acquired near-infrared and mid-infrared full-disk images, and partial-disk spectra at 0.26-0.65 μm (λ/Δλ ∼ 500) and 1.17-2.48 μm (λ/Δλ ∼ 50). Spectra show strong absorption features due to water vapor and ozone, which is a biosignature gas. We perform a significant recalibration of the UV-visible spectra and provide the first comparison of high-resolution visible Earth spectra to the NASA Astrobiology Institute's Virtual Planetary Laboratory three-dimensional spectral Earth model. We find good agreement with the observations, reproducing the absolute brightness and dynamic range at all wavelengths for all observation epochs, thus validating the model to within the ∼10% data calibration uncertainty. Data-model comparisons reveal a strong ocean glint signature in the crescent phase data set, which is well matched by our model predictions throughout the observed wavelength range. This provides the first observational test of a technique that could be used to determine exoplanet habitability from disk-integrated observations at visible and near-infrared wavelengths, where the glint signal is strongest. We examine the detection of the ozone 255 nm Hartley and 400-700 nm Chappuis bands. While the Hartley band is the strongest ozone feature in Earth's spectrum, false positives for its detection could exist. Finally, we discuss the implications of these findings for future exoplanet characterization missions.

79 ASTRONOMY AND ASTROPHYSICS↗

Achromatic registration of quadrature components of the optical spectrum in spectral domain optical coherence tomography

We have thoroughly investigated the method of simultaneous reception of spectral components with the achromatised quadrature phase shift between two portions of a reference wave, designed for the effective suppression of the 'mirror' artefact in the resulting image obtained by means of spectral domain optical coherence tomography (SD OCT). We have developed and experimentally tested a phase-shifting element consisting of a beam divider, which splits the reference optical beam into the two beams, and of delay lines being individual for each beam, which create a mutual phase difference of π/2 in the double pass of the reference beam. The phase shift achromatism over a wide spectral range is achieved by using in the delay lines the individual elements with different dispersion characteristics. The ranges of admissible adjustment parameters of the achromatised delay line are estimated for exact and inexact conformity of the geometric characteristics of its components to those calculated. A possibility of simultaneous recording of the close-to-quadrature spectral components with a single linear photodetector element is experimentally confirmed. The suppression of the artefact mirror peak in the OCT-signal by an additional 9 dB relative to the level of its suppression is experimentally achieved when the air delay line is used. Two-dimensional images of the surface positioned at an angle to the axis of the probe beam are obtained with the correction of the 'mirror' artefact while maintaining the dynamic range of the image. (laser biophotonics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Digital Miniature Cathode Ray Magnetometer

In this study, we introduce the concept and construction of an innovative Digital Miniature Cathode Ray Magnetometer designed for the precise detection of magnetic fields. This device addresses several limitations inherent to magnetic probes such as D.C. offset, nonlinearity, temperature drift, sensor aging, and the need for frequent recalibration, while capable of operating in a wide range of magnetic fields. The core principle of this device involves the utilization of a charged particle beam as the sensitivity medium. The system leverages the interaction of an electron beam with a scintillator material, which then emits visible light that is captured by an imager. The emitted scintillation light is captured by a CMOS sensor. This sensor not only records the scintillation light but also accurately determines the position of the electron beam, providing invaluable spatial information crucial for magnetic field mapping. The key innovation lies in the combination of electron beam projection, CMOS imager scintillation-based detection, and digital image signal processing. By employing this synergy, the magnetometer achieves remarkable accuracy, sensitivity and dynamic range. The precise position registration enabled by the CMOS sensor further enhances the device’s utility in capturing complex magnetic field patterns, allowing for 2D field mapping. In this work, the optimization of the probe’s performance is tailored for applications related to the characterization of insertion devices in light sources, including undulators.

Turqueti, Marcos↗