Interaction between Faraday rotation and Cotton-Mouton effects in polarimetry modeling for NSTX

The evolution of electromagnetic wave polarization is modeled for propagation in the major radial direction in the National Spherical Torus Experiment with retroreflection from the center stack of the vacuum vessel. This modeling illustrates that the Cotton-Mouton effect-elliptization due to the magnetic field perpendicular to the propagation direction-is shown to be strongly weighted to the high-field region of the plasma. An interaction between the Faraday rotation and Cotton-Mouton effects is also clearly identified. Elliptization occurs when the wave polarization direction is neither parallel nor perpendicular to the local transverse magnetic field. Since Faraday rotation modifies the polarization direction during propagation, it must also affect the resultant elliptization. The Cotton-Mouton effect also intrinsically results in rotation of the polarization direction, but this effect is less significant in the plasma conditions modeled. The interaction increases at longer wavelength and complicates interpretation of polarimetry measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using high-intensity laser-generated energetic protons to radiograph directly driven implosions

The recent development of petawatt-class lasers with kilojoule-picosecond pulses, such as OMEGA EP [L. Waxer et al., Opt. Photonics News 16, 30 (2005)], provides a new diagnostic capability to study inertial-confinement-fusion (ICF) and high-energy-density (HED) plasmas. Specifically, petawatt OMEGA EP pulses have been used to backlight OMEGA implosions with energetic proton beams generated through the target normal sheath acceleration (TNSA) mechanism. This allows time-resolved studies of the mass distribution and electromagnetic field structures in ICF and HED plasmas. This principle has been previously demonstrated using Vulcan to backlight six-beam implosions [A. J. Mackinnon et al., Phys. Rev. Lett. 97, 045001 (2006)]. The TNSA proton backlighter offers better spatial and temporal resolution but poorer spatial uniformity and energy resolution than previous D{sup 3}He fusion-based techniques [C. Li et al., Rev. Sci. Instrum. 77, 10E725 (2006)]. A target and the experimental design technique to mitigate potential problems in using TNSA backlighting to study full-energy implosions is discussed. The first proton radiographs of 60-beam spherical OMEGA implosions using the techniques discussed in this paper are presented. Sample radiographs and suggestions for troubleshooting failed radiography shots using TNSA backlighting are given, and future applications of this technique at OMEGA and the NIF are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The performance of the LHCf detector

The LHCf experiment is designed to measure energies and transverse momenta of neutral particles emitted in the forward region of {radical}(s) = 14 TeV p-p collision at {+-}140 m away from the interaction point1 (IP1) of LHC. The energy resolution is confirm to be within 5% and the position resolution is better than 0.2 mm for gamma-rays with energies from 100 GeV to 200 GeV by the test beam results at the CERN-SPS. LHCf has taken data at 2009 and 2010 at {radical}(s) = 900 GeV and 7 TeV collision. A brief summary of LHCf operation at LHC is also reported here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Hidden Sector Photons with the ADMX Detector

Hidden U(1) gauge symmetries are common to many extensions of the standard model proposed to explain dark matter. The hidden gauge vector bosons of such extensions may mix kinetically with standard model photons, providing a means for electromagnetic power to pass through conducting barriers. The axion dark matter experiment detector was used to search for hidden vector bosons originating in an emitter cavity driven with microwave power. We exclude hidden vector bosons with kinetic couplings {chi}>3.48x10{sup -8} for masses less than 3 {mu}eV. This limit represents an improvement of more than 2 orders of magnitude in sensitivity relative to previous cavity experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications of the Monte Carlo method in nuclear physics using the GEANT4 toolkit

The capabilities of the personal computers allow the application of Monte Carlo methods to simulate very complex problems that involve the transport of particles through matter. Among the several codes commonly employed in nuclear physics problems, the GEANT4 has received great attention in the last years, mainly due to its flexibility and possibility to be improved by the users. Differently from other Monte Carlo codes, GEANT4 is a toolkit written in object oriented language (C++) that includes the mathematical engine of several physical processes, which are suitable to be employed in the transport of practically all types of particles and heavy ions. GEANT4 has also several tools to define materials, geometry, sources of radiation, beams of particles, electromagnetic fields, and graphical visualization of the experimental setup. After a brief description of the GEANT4 toolkit, this presentation reports investigations carried out by our group that involve simulations in the areas of dosimetry, nuclear instrumentation and medical physics. The physical processes available for photons, electrons, positrons and heavy ions were used in these simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Designing Klod detector prototypes and results of their experimental tests

The projected KLOD facility is intended for finding and investigating the ultrarare decay K{sub L}{sup 0} {sup {yields} {pi}0{nu}{nu}}-bar; its branching ratio predicted by the Standard Model is Br = (3.0 {+-} 0.6) x 10{sup -11}. Designing and testing the prototype of the decay-volume veto system and beam veto calorimeter, which are the most important detectors of the facility, are considered. It is shown that the proposed beam veto calorimeter is able to detect {gamma} rays with a high efficiency at the neutron flux of 300 MHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CoSyR: A novel beam dynamics code for the modeling of synchrotron radiation effects

The self-consistent nonlinear dynamics of a relativistic charged particle beam interacting with its complete self-fields is a fundamental problem underpinning many of the accelerator design issues in high brightness beam applications, as well as the development of advanced accelerators. Particularly, synchrotron radiation induced effects in a magnetic dispersive beamline element can lead to collective beam instabilities and emittance growth. A novel beam dynamics code is developed based on a Lagrangian method for the calculation of the particles’ radiation near-fields using wavefront/wavelet meshes via the Green’s function of the Maxwell equations. These fields are then interpolated onto a moving mesh for dynamic update of the beam. This method allows radiation co-propagation and self-consistent interaction with the beam in 2D/3D simulations at greatly reduced numerical errors. Multiple levels of parallelisms are inherent in this method and implemented in our code CoSyR to enable at-scale simulations of nonlinear beam dynamics on modern computing platforms using MPI, multi-threading, and GPUs. Here, the current 2D implementation of CoSyR has been used to evaluate the transverse and longitudinal coherent radiation effects on the beam and to investigate beam optics designs proposed for mitigation of beam brightness degradation in a magnetic bunch compressor. In this paper, the design of CoSyR, as well as the benchmark with other coherent synchrotron radiation models, are described and discussed. Extension of the core algorithms to 3D is possible and planned.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomalous photoresponse of GaN x-ray Schottky detectors

GaN based materials are believed to be very stable materials, in particular, under irradiation by high energy photons such as x rays. We have studied x-ray detectors based on GaN Schottky diodes. Vertical Schottky diodes were fabricated based on a 20 mum thick undoped GaN layer grown on a conductive GaN substrate. Their photoresponse to near UV light and to x rays was measured. While the response to near UV light was fast and linear as expected, anomalous behaviors were observed under x-ray illumination. The photocurrent increases as the third power of the incident x-ray flux. The photocurrent transient when the x rays is turned on are long and nonexponential (S shape) and strongly differs from the off transient which is fast and exponential. Also, a very strong quenching of the x-ray photoresponse is observed when the detector is simultaneously illuminated with visible light. All of these anomalous behaviors are explained in the frame of a complete model involving traps and tunnel currents. A reasonable quantitative agreement between the model and the experimental data is obtained.

36 MATERIALS SCIENCE↗

Thrust Generation with Low-Power Continuous-Wave Laser and Aluminum Foil Interaction

The micro-newton thrust generation was observed through low-power continuous-wave laser and aluminum foil interaction without any remarkable ablation of the target surface. To evaluate the thrust characteristics, a torsion-balance thrust stand capable for the measurement of the thrust level down to micro-Newton ranges was developed. In the case of an aluminum foil target with 12.5 micrometer thickness, the maximum thrust level was 15 micro-newtons when the laser power was 20 W, or about 0.75 N/MW. It was also found that the laser intensity, or laser power per unit area, irradiated on the target was significantly important on the control of the thrust even under the low-intensity level.

36 MATERIALS SCIENCE↗

Test Study for Generation of Short Pulsed Synchrotron Radiation by Kicker Magnet in SPring-8 Storage Ring

A shorter pulse of synchrotron radiation is desired to measure a fast dynamic process exploration with a better resolution by material structure physics users. Among many complex schemes proposed for this purpose, we tested a simple scheme which makes use of a head-tail oscillation of a circulating electron beam with a small beam emittance. We have developed a new kicker magnet system which generated a short pulsed horizontal field of about 4.19 mT in 1.4 {mu}s pulse width with 1 Hz repetition. With this new developed kicker magnet system, we observed a bunch profile which leaned impressively between head and tail position by a visible light streak camera. Then we succeeded in achieving the shorter X-ray pulse width than the original one after a vertical slit being sliced by {approx}6 times. The observed X-ray pulse width was 7.38{+-}2.35 ps in FWHM.

43 PARTICLE ACCELERATORS↗

Machine Protection System for the Stepper Motor Actuated SyLMAND Mirrors

SyLMAND, the Synchrotron Laboratory for Micro and Nano Devices at the Canadian Light Source, consists of a dedicated X-ray lithography beamline on a bend magnet port, and process support laboratories in a clean room environment. The beamline includes a double mirror system with flat, chromium-coated silicon mirrors operated at varying grazing angles of incidence (4 mrad to 45 mrad) for spectral adjustment by high energy cut-off. Each mirror can be independently moved by two stepper motors to precisely control the pitch and vertical position. We present in this paper the machine protection system implemented in the double mirror system to allow for safe operation of the two mirrors and to avoid consequences of potential stepper motor malfunction.

43 PARTICLE ACCELERATORS↗

Area-selected Ion Milling for Reflection Wavefront Error Correction of Soft X-ray Multilayer Mirrors

For accurate reflection wavefront error correction of imaging soft X-ray multilayer mirrors, a period-by-period ion milling system was developed. A stable and homogenized radial distribution of ion beam was realized for an ion milling over a whole area of 100 mm-wide multilayer. To demonstrate the wavefront error correction principle, a dielectric multilayer mirror for visible light was locally milled by our system. Wavefront as measured by a phase shifting interferometer showed the reflection phase of local milling multilayer advanced. Area-selected ion millings with mask templates made of Mo and Si, and by photoresist contact masks were carried out. Although striped patterns generated by the difference of spectroscopic reflectance between Mo and Si were observed at peripherals of milling area when templates were used, a clear and sharp edge pattern was obtained with contact mask. Soft X-ray reflectance of a Mo/Si multilayer milled with photoresist contact mask showed good feasibility of precise wavefront error correction of multilayers. These results proved our phase correction method is promising and practical for the 0.1 nm-period correction of soft X-ray multilayer mirror.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

500-MHz x-ray counting with a Si-APD and a fast-pulse processing system

We introduce a counting system of up to 500 MHz for synchrotron x-ray high-rate measurements. A silicon avalanche photodiode detector was used in the counting system. The fast-pulse circuit of the amplifier was designed with hybrid ICs to prepare an ASIC system for a large-scale pixel array detector in near future. The fast amplifier consists of two cascading emitter-followers using 10-GHz band transistors. A count-rate of 3.25x10{sup 8} s{sup -1} was then achieved using the system for 8-keV x-rays. However, a baseline shift by adopting AC-coupling in the amplifier disturbed us to observe the maximum count of 4.49x10{sup 8} s{sup -1}, determined by electron-bunch filling into a ring accelerator. We also report that an amplifier with a baseline restorer was tested in order to keep the baseline level to be 0 V even at high input rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-accuracy X-ray detector calibration based on cryogenic radiometry

Cryogenic electrical substitution radiometers (ESRs) are absolute thermal detectors, based on the equivalence of electrical power and radiant power. Their core piece is a cavity absorber, which is typically made of copper to achieve a short response time. At higher photon energies, the use of copper prevents the operation of ESRs due to increasing transmittance. A new absorber design for hard X-rays has been developed at the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the electron storage ring BESSY II. The Monte Carlo simulation code Geant4 was applied to optimize its absorptance for photon energies of up to 60 keV. The measurement of the radiant power of monochromatized synchrotron radiation was achieved with relative standard uncertainties of less than 0.2 %, covering the entire photon energy range of three beamlines from 50 eV to 60 keV. Monochromatized synchrotron radiation of high spectral purity is used to calibrate silicon photodiodes against the ESR for photon energies up to 60 keV with relative standard uncertainties below 0.3 %. For some silicon photodiodes, the photocurrent is not linear with the incident radiant power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluorescence-type Monochromatic X-ray Beam-position Monitor with High-spatial Resolution for the NSLS-II Beamlines

We developed a fluorescence-type monochromatic X-ray beam-position monitor (X-BPM) with high-spatial resolution for end-station experiments at the initial project beamlines of the NSLS-II. We designed a ring array of multi-segmented Si PIN-junction photodiodes to use as a position sensor. Further, we integrated a low-noise charge-preamplification HERMES4 ASIC chip into an electronic readout system for photon-counting application. A series of precision measurements to characterize electronically the Si-photodiode sensor and the ASIC chip demonstrated that the inherent noise from the detector system is sufficiently low to meet our stringent requirements. Using a Gaussian beam, we parametrically modeled the optimum working distance to ensure the detector's best performance. Based upon the results from the parametric modeling, prototypes of the next versions of the X-BPM are being developed. In this paper, we describe the methodology for developing the new compact monochromatic X-ray BPM, including its instrumentation, detector modeling, and future plan.

43 PARTICLE ACCELERATORS↗

The RIKEN Materials Science Beamline at SPring-8: Towards Visualization of Electrostatic Interaction

In order to visualize molecular interaction by the experimental electrostatic potential analysis we have optimized the optical parameters and developed the high-resolution Debye-Scherrer camera at the RIKEN materials science beamline, BL44B2 of SPring-8. For the purpose the camera was designed to be equipped with the hybrid X-ray detector system. One is the conventional detector, the imaging plate readout off-line to carry out high d(interplanar spacing)-resolution measurements and the other is the CCD detector, which can be operated in a camera at variable distances for high angle-resolution measurements. In addition we have been developing an in-situ properties measurement system to visualize the electrostatic interaction completely synchronized with material functions.

43 PARTICLE ACCELERATORS↗

Dual energy phase contrast x-ray imaging with Talbot-Lau interferometer

In weakly absorbing materials such as polymers and soft tissue, x-ray phase sensitive imaging methods can provide substantially enhanced contrast compared to classical, absorption based radiography. For specific applications, the latter can be applied in a dual energy scheme that helps to identify, discriminate and/or quantify materials. In this paper, we report on a new method that combines the idea of dual energy with x-ray phase contrast imaging and thus provides material sensitivity among poor absorbers. The dual energy modality cannot be applied in common phase contrast imaging schemes because of their demand for limited bandwidth or even monochromatic x-ray sources. Our new interferometric method based on diffraction gratings can overcome this shortcoming and thus simultaneously deliver x-ray phase contrast images for two distinct x-ray energy intervals. It has been shown that high quality images can be obtained with the dual energy phase setup. Energy spectra with 40 kV and 70 kV were applied to obtain low- and high-energy images, respectively. Furthermore, an estimation of the effective energy in the image formation process for absorption and phase contrast was experimentally determined. Examples are shown for which the dual energy phase contrast modality delivers complementary information on material composition when compared with the conventional dual energy scheme.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extraction of the Compton Form Factor H from DVCS Measurements in the Quark Sector

Working at twist 2 accuracy and assuming the dominance of the Generalized Parton Distribution H we study the helicity-dependent and independent cross sections measured in Hall A, the beam spin asymmetries measured in Hall B at Jefferson Laboratory and beam charge, beam spin and target spin asymmetries measured by Hermes. We extract the real and imaginary parts of the Compton Form Factor H, the latter being obtained with a 20-50 % uncertainty. We pay extra attention to the estimation of systematic errors on the extraction of H. We discuss our results and compare to other extractions as well as to the popular VGG model.