Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Extracting single fiber transverse and shear moduli from off-axis misalignment fiber tensile testing

Small diameter (<100 μm) fibers (e.g. carbon fibers, Kevlar, and fiberglass) and wires (e.g. ultrafine copper and aluminum wires) are frequently used in many different engineering applications, such as for light weighting structures, electromagnetic shielding for aircraft/infrastructure/EVs, vibration damping, biological sensors, aerospace electrical devices, and electric windings just to name a few. Due to the manufacturing process, the fibers and wires are pulled and stretched to produce a preferential alignment. Therefore, thin fibers and wires typically display different properties along the length of the fiber as opposed to their cross section and many fibers/wires are considered transversely isotropic. The axial properties of fibers/wires can be ascertained via tensile testing of single-filaments or fiber tows, but the radial properties require much more effort to measure. Knowing these properties is important for the accurate prediction of micromechanical models and manipulation of fibers during micromanufacturing. In this paper, a new technique was developed to determine the transverse/shear moduli and strength of a material by conducting tensile tests of the material at increasing misalignment angles from the tensile axis. Due to the transversely isotropic nature of the material, the transverse/shear moduli and strength influence the experimental results recorded by the test machine to different degrees based on the amount of misalignment in the test setup. An equation was derived to determine the influence of each of the material properties based on the misalignment angle by manipulating the stiffness matrix for transversely isotropic materials using the transformation matrices. Then, curve fitted coefficients were used to identify the material properties. Here, the strengths were similarly determined by curve fitting an off-axis Tsai-Hill failure criteria to determine the influence of transverse, shear, and tensile strengths based on the complex loading condition provided by the off-axis tensile test. Zoltek Panex 35 carbon fibers were used to demonstrate this new technique and the determined properties were then compared to those obtained from nanoindentation and from literature. Fracture surfaces provide insight into the different failure mechanisms at various misalignment angles.

36 MATERIALS SCIENCE↗

The ALICE Electromagnetic Calorimeter

ALICE is the general purpose experiment at the LHC dedicated to the study of heavy-ion collisions. The electromagnetic calorimeter (EMCal) is a late addition to the ALICE suite of detectors with first modules installed in ALICE this year. The EMCal is designed to trigger on high energy gamma-rays and jets, and to enhance the capabilities of ALICE for these measurements. The EMCal is a Pb/scintillator sampling shish-kebab type calorimeter. The EMCal construction, readout, and performance in beam tests at the CERN SPS and PS are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test of fundamental symmetries via the Primakoff effect

The three neutral pseudoscalar mesons, pi^0, eta and eta', represent one of the most interesting systems in strong interaction physics. A study of the electromagnetic properties of these mesons provides a sensitive probe of the symmetry structure of QCD at low energy. A comprehensive experimental program at Jefferson Laboratory (Jlab) is aimed at gathering high precision measurements on the two-photon decay widths and transition form factors at low Q^2 of pi^0, eta and eta' via the Primakoff effect. The completed experiments on the pi^0 radiative decay width at Jlab 6 GeV, and other planned measurements at Jlab 12GeV will provide a rich laboratory to test the chiral anomaly and to study the origin and dynamics of chiral symmetry breaking at the confinement scale of QCD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FEMCAM Analysis of SULTAN Test Results for ITER Nb3SN Cable-conduit Conductors

Performance degradation due to filament fracture of Nb3 Sn cable-in-conduit conductors (CICCs) is a critical issue in large-scale magnet designs such as ITER which is currently being constructed in the South of France. The critical current observed in most SULTAN TF CICC samples is significantly lower than expected and the voltage-current characteristic is seen to have a much broader transition from a single strand to the CICC. Moreover, most conductors exhibit the irreversible degradation due to filament fracture and strain relaxation under electromagnetic cyclic loading. With recent success in monitoring thermal strain distribution and its evolution under the electromagnetic cyclic loading from in situ measurement of critical temperature, we apply FEMCAM which includes strand filament breakage and local current sharing effects to SULTAN tested CICCs to study Nb3 Sn strain sensitivity and irreversible performance degradation. FEMCAM combines the thermal bending effect during cool down and the EM bending effect due to locally accumulating Lorentz force during magnet operation. It also includes strand filament fracture and related local current sharing for the calculation of cable n value. In this paper, we model continuous performance degradation under EM cyclic loading based on strain relaxation and the transition broadening upon cyclic loading to the extreme cases seen in SULTAN test data to better quantify conductor performance degradation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of a LYSO crystal array from threshold to 100 MeV

We report measurements of ten custom-made high-homogeneity LYSO crystals. The investigation is motivated by the need for a compact, high-resolution, and fast electromagnetic calorimeter for a new rare pion decay experiment. Each 2.5 x 2.5 x 18 cm 3 crystal was first characterized for general light yield properties and then its longitudinal response uniformity and energy resolution were measured using low-energy gamma sources. The ten crystals were assembled as an array and subjected to a 30–100 MeV positron beam with excellent momentum definition. The energy and timing resolutions were measured as a function of energy, and the spatial resolution was determined at 70 MeV. An additional measurement using monoenergetic 17.6 MeV gammas produced through a p-Li resonance was later made after the photosensors used in positron testing were improved. Here, as an example of the results, the energy resolution at 70 MeV of (1.52 ± 0.03) % is more than two times better than reported results using previous generation LYSO crystals.

Electromagnetic calorimeter↗

A method to fuse multiphysics waveforms and improve predictive explosion detection: theory, experiment and performance

Natural and human-made sources of transient energy often emit multiple geophysical signatures that include mechanical and electromagnetic waveforms. We present a constructive method to fuse and evaluate statistics that we derive from such multiphysics waveforms that improves our capability to detect small, near-ground explosions over similar methods that consume single signature waveforms. Our method advances Fisher's Combined Probability Test (Fisher's Method) to operate under both hypotheses of a binary test on noisy data and provide researchers with the density functions required to forecast the ability of Fisher's Method to screen fused explosion signatures from noise. We apply this method against 12 d, multisignature explosion and noise records to show (1) that a fused multiphysics waveform statistic that combines radio, acoustic and seismic waveform data can identify explosions roughly 0.8 magnitude units lower than an acoustic emission, STA/LTA detector for the same detection probability and (2) that we can quantitatively predict how this fused, multiphysics statistic performs with Fisher's Method. Our work thereby offers a baseline method for predictive waveform fusion that supports multiphenomenological explosion monitoring (multiPEM) and is applicable to any binary testing problem in observational geophysics.

58 GEOSCIENCES↗

Witten effect in a crystalline topological insulator

It has been noted a long time ago that a term of the form theta(e{sup 2}/2pih)Bcentre dotE may be added to the standard Maxwell Lagrangian without modifying the familiar laws of electricity and magnetism. theta is known to particle physicists as the 'axion' field and whether or not it has a nonzero expectation value in vacuum remains a fundamental open question of the standard model. A key manifestation of the axion term is the Witten effect: a unit magnetic monopole placed inside a medium with thetanot =0 is predicted to bind a (generally fractional) electric charge -e(theta/2pi+n) with n integer. Here we conduct a test of the Witten effect based on the recently established fact that the axion term with theta=pi emerges naturally in the description of the electromagnetic response of a class of crystalline solids called topological insulators--materials distinguished by strong spin-orbit coupling and nontrivial band structures. Using a simple physical model for a topological insulator we demonstrate the existence of a fractional charge bound to a monopole by an explicit numerical calculation. We also propose a scheme for generating an 'artificial' magnetic monopole in a topological insulator film that may be used to facilitate an experimental test of Witten's prediction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved constraints on isotropic shift and anisotropies of the speed of light using rotating cryogenic sapphire oscillators

We demonstrate that Michelson-Morley tests, which detect direction-dependent anisotropies in the speed of light, can also be used to place limits upon isotropic deviations of the vacuum speed of light from c, as described by the photon-sector standard model extension parameter {kappa}-tilde{sub tr}. A shift in the speed of light that is isotropic in one inertial frame implies anisotropic shifts in others. Using observer Lorentz covariance, we derive the time-dependent variations in the relative resonance frequencies of a pair of electromagnetic resonators that would be generated by such a shift in the rest frame of the Sun. A new analysis of a recent experimental test of relativity using this result constrains {kappa}-tilde{sub tr} with a precision of 7.4x10{sup -9}. This represents the first constraint on {kappa}-tilde{sub tr} by a Michelson-Morley experiment and the first analysis of a single experiment to simultaneously set limits on all nine nonbirefringent terms in the photon sector of the minimal standard model extension.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Forward Drift Chamber for the GlueX Experiment at the 12 GeV CEBAF Machine

The GlueX experiment will search for exotic mesons produced by 9 GeV linearly polarized photons from the upgraded CEBAF machine. It is critical to detect and measure the four-momenta of all the charged particles and photons resulting from the decays of the mesons. The solenoid-based detector system includes tracking detectors and calorimeters. The Forward Drift Chamber, FDC, consists of 24 circular planar drift chambers of 1m diameter. Additional cathode readout is required to achieve efficient pattern recognition. The detection of photons by the electromagnetic calorimeters imposes constraints on the amount of material used in the FDC. The specific features of the detector and the readout electronics will be described. Results from the tests of the full scale prototype will be presented, as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of the CMS hadron calorimeters using proton-proton collision data at √ s = 13 TeV

Methods are presented for calibrating the hadron calorimeter system of the CMS detector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities |η| < 3 and are positioned inside the solenoidal magnet. An outer calorimeter, outside the magnet coil, covers |η| < 1.26, and a steel and quartz-fiber Cherenkov forward calorimeter extends the coverage to |η| < 5.19. The initial calibration of the calorimeters was based on results from test beams, augmented with the use of radioactive sources and lasers. The calibration was improved substantially using proton-proton collision data collected at √ s = 7 , 8, and 13 TeV, as well as cosmic ray muon data collected during the periods when the LHC beams were not present. The present calibration is performed using the 13 TeV data collected during 2016 corresponding to an integrated luminosity of 35.9 fb -1 . The intercalibration of channels exploits the approximate uniformity of energy collection over the azimuthal angle. The absolute energy scale of the central and endcap calorimeters is set using isolated charged hadrons. The energy scale for the electromagnetic portion of the forward calorimeters is set using Z→ ee data. The energy scale of the outer calorimeters has been determined with test beam data and is confirmed through data with high transverse momentum jets. In this paper, we present the details of the calibration methods and accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Functionalizing magnet additive manufacturing with in-situ magnetic field source

Additive manufacturing via 3-D printing technologies have become a frontier in materials research, including its application in the development and recycling of permanent magnets. This work addresses the opportunity to integrate magnetic field sources into 3-D printing process in order to enable printing, alignment of anisotropic permanent magnets or magnetizing of magnetic filler materials, without requiring further processing. Specifically, a nonaxisymmetric electromagnet-type field source architecture was designed, modelled, constructed, installed to a fused filament commercial 3-D printer, and tested. The testing was performed by applying magnetic field while printing composite anisotropic Nd-Fe-B + Sm-Fe-N powders bonded in Nylon12 (65 vol.%) and recycled Sm-Co powder bonded in PLA (15 vol.%). Magnetic characterization indicated that the degree-of-alignment of the magnet powders increased both with alignment field strength (controlled by the electric current applied to the magnetizing system) and the printing temperature. Both coercivity and remanence were found to be strongly dependent on the degree-of-alignment, except for printing performed below but near the Curie temperature of Nd-Fe-B (310 ° C). At applied field of 0.15 kOe, Sm-Co and hybrid Nd-Fe-B/Sm-Fe-N printed samples showed degrees-of-alignment of 83 % and 65 %, respectively. The variations in coercivity were consistent with previous observations in bonded magnet materials. This work verifies that integration of magnetic field sources into 3-D printing processes will result in magnetic alignment of particles while ensuring that other advantages of 3-D printing are retained.

3-D printing↗

Gemma

Gemma is a linear electromagnetic code developed at Sandia National Laboratories based on the method of moments in the frequency domain, with the objective of supporting next-generation high-performance computing (HPC) platforms. Gemma provides full-wave computational electromagnetic modeling. As an example, Gemma models electromagnetic radiation (EMR) environments, including those resulting from radar (both hostile and friendly) and high-power-electromagnetic (HPEM) sources. Gemma refers to a suite of source code and scripts that aid in compiling, running, and testing the primary Gemma executable, which can be compiled for diverse platforms including CPUs, GPUs, and MICs by leveraging Sandia's Kokkos library.SAND2019-15221 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Zinser, Brian↗

A compact electromagnetic neutron nutator for precise neutron spin manipulation

A superconducting electromagnetic nutator (EMN) capable of generating a magnetic field vector along an arbitrary direction on a 2D plane has been designed. Its performance in precisely manipulating the neutron polarization vector has been tested at the HB2-D polarized development beamline at the High Flux Isotope Reactor. Unlike mechanical nutators that require physical handling or motor-driven actuation to rotate the magnetic field, the magnitude and orientation of the magnetic field produced by the EMN can be controlled electromagnetically. Further, the compact design (~15 mm depth, not including cryogenic housing) of this device ensures ease of coupling within existing superconducting neutron spin manipulation devices, such as magnetic Wollaston prisms (MWP), resonant radio frequency (RF) flippers, spherical neutron polarimetry (SNP) devices, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test of Ion Cyclotron Resonance Instability Using Proton Distributions Obtained From Van Allen Probe-A Observations

Anisotropic velocity distributions of protons have long been considered as free energy sources for exciting electromagnetic ion cyclotron (EMIC) waves in the Earth's magnetosphere. Here we rigorously calculated the proton anisotropy parameter using proton data obtained from Van Allen Probe–A observations. The calculations are performed for times during EMIC wave events (distinguishing the times immediately after and before EMIC wave onsets) and for times exhibiting no EMIC waves. We find that the anisotropy values are often larger immediately after EMIC wave onsets than the times just before EMIC wave onsets and the non–EMIC wave times. The increase in anisotropy immediately after the EMIC wave onsets is rather small but discernible, such that the average increase is by ~15% relative to the anisotropy values during the non–EMIC wave times and ~8% compared to those just before the EMIC wave onsets. Based on the calculated anisotropy values, we test the criterion for ion cyclotron instability suggested by Kennel and Petschek by applying it to the EMIC wave events. We find that despite the weak increase in anisotropy, the majority of the EMIC wave events satisfy the instability criterion. We suggest that the proton distributions often remain close to the marginal state to ion cyclotron instability, and consequently, the proton anisotropy values should often be observed near threshold values for ion cyclotron instability. In conclusion, we demonstrate the usefulness and limitation of the instability criteria expressed in the form of an inverse relation between the anisotropy and plasma beta.

79 ASTRONOMY AND ASTROPHYSICS↗

Peculiar velocity field: Constraining the tilt of the Universe

A large bulk flow, which is in tension with the Lambda cold dark matter ({Lambda}CDM) cosmological model, has been observed. In this paper, we provide a physically plausible explanation of this bulk flow, based on the assumption that some fraction of the observed dipole in the cosmic microwave background is due to an intrinsic fluctuation, so that the subtraction of the observed dipole leads to a mismatch between the cosmic microwave background defined rest frame and the matter rest frame. We investigate a model that takes into account the relative velocity (hereafter the tilted velocity) between the two frames, and develop a Bayesian statistic to explore the likelihood of this tilted velocity. By studying various independent peculiar velocity catalogs, we find that (1) the magnitude of the tilted velocity u is around 400 km/s, and its direction is close to what is found from previous bulk flow analyses; for most catalogs analyzed, u=0 is excluded at about the 2.5{sigma} level; (2) constraints on the magnitude of the tilted velocity can result in constraints on the duration of inflation, due to the fact that inflation can neither be too long (no dipole effect) nor too short (very large dipole effect); (3) under the assumption of a superhorizon isocurvature fluctuation, the constraints on the tilted velocity require that inflation lasts at least 6 e-folds longer (at the 95% confidence interval) than that required to solve the horizon problem. This opens a new window for testing inflation and models of the early universe from observations of large scale structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low Frequency Electromagnetic Pulse and Explosions

This paper reviews and summarizes prior work related to low frequency (< 100 Hz) EMP (ElectroMagnetic Pulse) observed from explosions. It focuses on how EMP signals might, or might not, be useful in monitoring underground nuclear tests, based on the limits of detection, and physical understanding of these signals. In summary: (1) Both chemical and nuclear explosions produce an EMP. (2) The amplitude of the EMP from underground explosions is at least two orders of magnitude lower than from above ground explosions and higher frequency components of the signal are rapidly attenuated due to ground conductivity. (3) In general, in the near field, that is distances (r) of less than 10s of kilometers from the source, the amplitude of the EMP decays approximately as 1/r{sup 3}, which practically limits EMP applications to very close (<{approx}1km) distances. (4) One computational model suggests that the EMP from a decoupled nuclear explosion may be enhanced over the fully coupled case. This has not been validated with laboratory or field data. (5) The magnitude of the EMP from an underground nuclear explosion is about two orders of magnitude larger than that from a chemical explosion, and has a larger component of higher frequencies. In principle these differences might be used to discriminate a nuclear from a chemical explosion using sensors at very close (<{approx}1 km) distances. (6) Arming and firing systems (e.g. detonators, exploding bridge wires) can also produce an EMP from any type of explosion. (7) To develop the understanding needed to apply low frequency EMP to nuclear explosion monitoring, it is recommended to carry out a series of controlled underground chemical explosions with a variety of sizes, emplacements (e.g. fully coupled and decoupled), and arming and firing systems.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Effects of Cell Phone Radiofrequency Signal Exposure on Brain Glucos Metabolism

The dramatic increase in use of cellular telephones has generated concern about possible negative effects of radiofrequency signals delivered to the brain. However, whether acute cell phone exposure affects the human brain is unclear. To evaluate if acute cell phone exposure affects brain glucose metabolism, a marker of brain activity. Randomized crossover study conducted between January 1 and December 31, 2009, at a single US laboratory among 47 healthy participants recruited from the community. Cell phones were placed on the left and right ears and positron emission tomography with ({sup 18}F)fluorodeoxyglucose injection was used to measure brain glucose metabolism twice, once with the right cell phone activated (sound muted) for 50 minutes ('on' condition) and once with both cell phones deactivated ('off' condition). Statistical parametric mapping was used to compare metabolism between on and off conditions using paired t tests, and Pearson linear correlations were used to verify the association of metabolism and estimated amplitude of radiofrequency-modulated electromagnetic waves emitted by the cell phone. Clusters with at least 1000 voxels (volume >8 cm{sup 3}) and P < .05 (corrected for multiple comparisons) were considered significant. Brain glucose metabolism computed as absolute metabolism ({micro}mol/100 g per minute) and as normalized metabolism (region/whole brain). Whole-brain metabolism did not differ between on and off conditions. In contrast, metabolism in the region closest to the antenna (orbitofrontal cortex and temporal pole) was significantly higher for on than off conditions (35.7 vs 33.3 {micro}mol/100 g per minute; mean difference, 2.4 [95% confidence interval, 0.67-4.2]; P = .004). The increases were significantly correlated with the estimated electromagnetic field amplitudes both for absolute metabolism (R = 0.95, P < .001) and normalized metabolism (R = 0.89; P < .001). In healthy participants and compared with no exposure, 50-minute cell phone exposure was associated with increased brain glucose metabolism in the region closest to the antenna. This finding is of unknown clinical significance.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

CMS Full Simulation for Run 3

We report the status of the CMS full simulation for Run 3. During the long shutdown of the LHC a significant update has been introduced to the CMS code for simulation. The CMS geometry description is reviewed. Several important modifications were needed. CMS detector description software is migrated to the DD4Hep community developed tool. We will report on our experience obtained during the process of this migration. Geant4 10.7 is the CMS choice for Run 3 simulation productions. We will discuss arguments for this choice, the strategy of adaptation of a new Geant4 version, and will report on the physics performance of the CMS simulation. A special Geant4 Physics List configuration FTFP_BERT_EMM will be described, which provides a compromise between simulation accuracy and CPU performance. A significant fraction of time for simulation of CMS events is spent on tracking of charged particles in a magnetic field. In the CMS simulation a dynamic choice of Geant4 parameters for tracking in field is implemented. A new method is introduced into simulation of electromagnetic components of hadronic showers in the electromagnetic calorimeter of CMS. For low-energy electrons and positrons a parametrization of GFlash type is applied. Results of tests of this method will be discussed. In summary, we expect about 25% speedup of the CMS simulation production for Run 3 compared to the Run 2 simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗