Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrical detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Mie scattering of the interplanetary magnetic field by the whole moon

It is known from the Apollo magnetometer experiments that significant electromagnetic induction takes place in the lunar interior. This induction is excited by fluctuations of the interplanetary magnetic field and is detected by the induced fields on the surface of the moon. These results are reviewed briefly and the formal properties of the theory are discussed. It is shown that the mathematical treatment parallels that for classical electromagnetic scattering. Further the wavelength spectrum of the fluctuations of the interplanetary magnetic field include scales consistent with the radius of the moon. The consequence is that the moon is excited in several modes. Quadrupole and possibly octupole magnetic multipoles are found in the data. The electric type radiation corresponding to transverse magnetic excitation appears suppressed and far below the detection threshold of the magnetometers.

Sonett, C. P.↗

Electron concentrations calculated from the lower hybrid resonance noise band observed by Ogo 3.

A noise band at the lower hybrid resonance (LHR) is often detected by the VLF and ELF receivers on Ogo 3, using the electric antenna. In some cases the noise band is at the geometric mean gyrofrequency as measured by the Goddard Space Flight Center (GSFC) magnetometer, and local LHR in a dense H(+) plasma is indicated; in such cases, electron concentration can be calculated, if it is assumed that heavy ions are negligible. Observations at midlatitudes and altitudes of a few earth radii show local concentrations as low as 1.4 electrons/cu cm. In one case the concentrations obtained from the LHR noise band agree with those measured simultaneously by the GSFC ion mass spectrometer within a factor of 2. In another case the concentration is observed to fall by a factor of 2 in 150 km and then to decrease roughly as R to the minus fourth power, in agreement with whistler measurements outside the plasmapause.

Burtis, W. J.↗

Design and performance of heart assist or artificial heart control systems

The factors leading to the design of a controlled driving system for either a heart assist pump or artificial heart are discussed. The system provides square pressure waveform to drive a pneumatic-type blood pump. For assist usage the system uses an R-wave detector circuit that can detect the R-wave of the electrocardiogram in the presence of electrical disturbances. This circuit provides a signal useful for synchronizing an assist pump with the natural heart. It synchronizes a square wave circuit, the output of which is converted into square waveforms of pneumatic pressure suitable for driving both assist device and artificial heart. The pressure levels of the driving waveforms are controlled by means of feedback channels to maintain physiological regulation of the artificial heart's output flow. A more compact system that could achieve similar regulatory characteristics is also discussed.

Webb, J. A., Jr.↗

Preprototype vapor compression distillation subsystem

A three-person capacity preprototype vapor compression distillation subsystem for recovering potable water from wastewater aboard spacecraft was designed, assembled, and tested. The major components of the subsystem are: (1) a distillation unit which includes a compressor, centrifuge, central shaft, and outer shell; (2) a purge pump; (3) a liquids pump; (4) a post-treat cartridge; (5) a recycle/filter tank; (6) an evaporator high liquid level sensor; and (7) the product water conductivity monitor. A computer based control monitor instrumentation carries out operating mode change sequences, monitors and displays subsystem parameters, maintains intramode controls, and stores and displays fault detection information. The mechanical hardware occupies 0.467 m3, requires 171 W of electrical power, and has a dry weight of 143 kg. The subsystem recovers potable water at a rate of 1.59 kg/hr, which is equivalent to a duty cycle of approximately 30% for a crew of three. The product water has no foul taste or odor. Continued development of the subsystem is recommended for reclaiming water for human consumption as well as for flash evaporator heat rejection, urinal flushing, washing, and other on-board water requirements.

Ellis, G. S.↗

EMI characteristics of a potential control system

With the development and use of charged particle sources for controlling spacecraft potentials there is a need to better understand the effects of these systems on spacecraft operations. The emission of charged particles perturbs the spacecraft environment and signals are generated which may interfere with other vehicle functions. In particular, the generated signals are apt to interfere with detectors for observing waves that exist naturally in the space environment. Examples of this type of interference are presented from the SCATHA satellite during a period when the vehicle was highly charged. A plasma source on board the spacecraft succeeded in discharging the vehicle with each of four different operating modes. The VLF broadband receiver on SCATHA detected interference over the entire 0-5 kHz range of both the electric and magnetic field detectors during these charged particle emissions. This frequency range includes the 2 kHz electron gyrofrequency but is below the 9 kHz electron plasma frequency. The observations suggest that interference occurs through introduction of anomalous signals, and through suppression of background field measurements.

Donatelli, D. E.↗

Nickel hydrogen multicell common pressure vessel battery development update

The technology background and design qualification of the multicell common pressure vessel nickel hydrogen battery are described. The results of full flight qualification, including random vibration at 19.5 g for two minutes in each axis, electrical characterization in a thermal vacuum chamber, and mass spectroscopy vessel leak detection are reviewed and 12.7 cm qualification and 25.4 cm design adaptation are discussed.

Zagrodnik, Jeffrey P.↗

Remote tire pressure sensing technique

A remote tire pressure sensing technique is provided which uses vibration frequency to determine tire pressure. A vibration frequency measuring device is attached to the external surface of a tire which is then struck with an object, causing the tire to vibrate. The frequency measuring device measures the vibrations and converts the vibrations into corresponding electrical impulses. The electrical impulses are then fed into the frequency analyzing system which uses the electrical impulses to determine the relative peaks of the vibration frequencies as detected by the frequency measuring device. The measured vibration frequency peaks are then compared to predetermined data describing the location of vibration frequency peaks for a given pressure, thereby determining the air pressure of the tire.

Robinson, Howard H.↗

Lightning Studies Using VHF Waveform Data

Several atmospheric electricity studies were begun utilizing VHF lightning data obtained with the lightning detection and ranging system (LDAR) at the Kennedy Space Center (KSC). The LDAR system uses differences in the time of arrival of electromagnetic noise generated by the lightning process to seven antennas to calculate very accurate three dimensional locations of lightning. New software was developed to obtain the source location of multiple, simultaneous, and spatially separate lightning signatures. Three studies utilizing these data were begun this summer: (1) VHF observations of simultaneous lightning, (2) ground based VHF observations of transionospheric pulse pairs (TIPPs), and (3) properties of intra-cloud recoil streamers. The principal result of each of these studies are: (1) lightning commonly occurs in well separated (2-50 km) regions simultaneously, (2) large amplitude pairs of VHF pulses are commonly observed on the ground but had not been previously identified due to the large number of signals usually observed in the VHF noise of close lightning, and (3) the VHF Q-noise and pulse signatures associated with K-changes within intra-cloud lightning propagate at velocities of more than 10(exp 8) m/s. The interim results of these three studies are reviewed in this brief report.

Moldwin, Mark↗

Fuel Line Based Acoustic Flame-Out Detection System

An acoustic flame-out detection system that renders a large high pressure combustor safe in the event of a flame-out and possible explosive reignition. A dynamic pressure transducer is placed in the fuel and detects the stabilizing fuel pressure oscillations, caused by the combustion process. An electric circuit converts the signal from the combustion vortices, and transmitted to the fuel flow to a series of pulses. A missing pulse detector counts the pulses and continuously resets itself. If three consecutive pulses are missing, the circuit closes the fuel valve. With fuel denied the combustor is shut down or restarted under controlled conditions.

Puster, Richard L.↗

Multi-Dimensional Damage Detection

Methods and systems may provide for a structure having a plurality of interconnected panels, wherein each panel has a plurality of detection layers separated from one another by one or more non-detection layers. The plurality of detection layers may form a grid of conductive traces. Additionally, a monitor may be coupled to each grid of conductive traces, wherein the monitor is configured to detect damage to the plurality of interconnected panels in response to an electrical property change with respect to one or more of the conductive traces. In one example, the structure is part of an inflatable space platform such as a spacecraft or habitat.

Gibson, Tracy L.↗

Multi-Dimensional Damage Detection

Methods and systems may provide for a structure having a plurality of interconnected panels, wherein each panel has a plurality of detection layers separated from one another by one or more non-detection layers. The plurality of detection layers may form a grid of conductive traces. Additionally, a monitor may be coupled to each grid of conductive traces, wherein the monitor is configured to detect damage to the plurality of interconnected panels in response to an electrical property change with respect to one or more of the conductive traces. In one example, the structure is part of an inflatable space platform such as a spacecraft or habitat.

Gibson, Tracy L.↗

Multi-Dimensional Damage Detection

Methods and systems may provide for a structure having a plurality of interconnected panels, wherein each panel has a plurality of detection layers separated from one another by one or more non-detection layers. The plurality of detection layers may form a grid of conductive traces. Additionally, a monitor may be coupled to each grid of conductive traces, wherein the monitor is configured to detect damage to the plurality of interconnected panels in response to an electrical property change with respect to one or more of the conductive traces. In one example, the structure is part of an inflatable space platform such as a spacecraft or habitat.

Gibson, Tracy L.↗

Analog Environments for Venus Aerosol Instrument and Mission Concept Testing

The most common hypothesis discussed for life on Venus is a habitat in the dense, persistent clouds, which are primarily sulfuric acid with a secondary water component. Although Earth lacks a complete Venus analog environment, several partial analogs exist which can inform our understanding of the requirements for cloud habitability as well as serving as potential testbeds for future Venus instruments or missions. Earth’s tropospheric clouds have larger particles, more water, and shorter lifetimes than Venus’s; however, they have a partial overlap in pressure and temperature, and are our only example of an airborne habitat.They can inform how particle residence time and microbial generation time constrain habitable atmospheric regions. On the biological side, this includes available nutrients and energy, environmental stressors such as radiation, osmotic potential and acidity, and time spent in protective but inactive forms (endospores, cysts, akinetes); on the physical side, gravity, air density and viscosity, thermal lofting, gravity waves, scavenging due to precipitation, and other airflow dynamics, as well as effective particle radius and electrical charge. They can also enable sampling strategy tests for airborne life detection, ranging from10 2 to10 8 viable cells/mL (10 -3 to 10 -9 cells/particle). Conversely, Earth's stratospheric sulfate layer lacks an active microbial presence, and is at a colder and less dense altitude but has partially analogous values in terms of H2SO4 and water concentration, particle size, and number density. These aerosols are accessible to aircraft and high-altitude balloons. Even more accessible potential analogs include sea spray, which overlaps with the smaller (haze) particle sizes and densities at Venus and contains trace organic constituents; marine fog, which at higher densities can match Venus’s larger (Mode 2) particle properties and contains a range of trace compounds including ammonia, phosphates, sulfates, and nitrates; and spray from acidic hydrothermal systems, which can cover a wide variety of sizes, densities, and chemical compositions. These analogs could improve the development of Venus cloud sampling instruments or sondes, including field tests of material compatibility, particle capture efficiency, and analysis sensitivity.

Analog↗

Detection and Use of Load and Gage Output Repeats of Wind Tunnel Strain-Gage Balance Data

Criteria are discussed that may be used for the detection of load and gage output repeats of wind tunnel strain-gage balance data. First, empirical thresholds are introduced that help determine if the loads or electrical outputs of a pair of balance calibration or check load data points match. A threshold of 0.01 percent of the load capacity is suggested for the identification of matching loads. Similarly, a threshold of 0.1 microV/V is recommended for the identification of matching electrical outputs. Two examples for the use of load and output repeats are discussed to illustrate benefits of the implementation of a repeat point detection algorithm in a balance data analysis software package. The first example uses the suggested load threshold to identify repeat data points that may be used to compute pure errors of the balance loads. This type of analysis may reveal hidden data quality issues that could potentially be avoided by making calibration process improvements. The second example uses the electrical output threshold for the identification of balance fouling. Data from the calibration of a six-component force balance is used to illustrate the calculation of the pure error of the balance loads.

strain-gage balance↗

Determine Optimal Stimulus Amplitude for Using Vestibular Stochastic Stimulation to Improve Balance Function

Sensorimotor changes such as postural and gait instabilities can affect the functional performance of astronauts when they transition across different gravity environments. We are developing a method, based on stochastic resonance (SR), to enhance information transfer by applying non-zero levels of external noise on the vestibular system (vestibular stochastic resonance, VSR). Our previous work has shown the advantageous effects of VSR in a balance task of standing on an unstable surface [1]. This technique to improve detection of vestibular signals uses a stimulus delivery system that provides imperceptibly low levels of white noise-based binaural bipolar electrical stimulation of the vestibular system. The goal of this project is to determine optimal levels of stimulation for SR applications by using a defined vestibular threshold of motion detection. A series of experiments were carried out to determine a robust paradigm to identify a vestibular threshold that can then be used to recommend optimal stimulation levels for sensorimotor adaptability (SA) training applications customized to each crewmember. The amplitude of stimulation to be used in the VSR application has varied across studies in the literature such as 60% of nociceptive stimulus thresholds [2]. We compared subjects' perceptual threshold with that obtained from two measures of body sway. Each test session was 463s long and consisted of several 15s long sinusoidal stimuli, at different current amplitudes (0-2 mA), interspersed with 20-20.5s periods of no stimulation. Subjects sat on a chair with their eyes closed and had to report their perception of motion through a joystick. A force plate underneath the chair recorded medio-lateral shear forces and roll moments. Comparison of threshold of motion detection obtained from joystick data versus body sway suggests that perceptual thresholds were significantly lower. In the balance task, subjects stood on an unstable surface and had to maintain balance, and the stimulation was administered from 20-400% of subjects' vestibular threshold. Optimal stimulation amplitude was determined at which the balance performance was best compared to control (no stimulation). Preliminary results show that, in general, using stimulation amplitudes at 40-60% of perceptual motion threshold significantly improved the balance performance. We hypothesize that VSR stimulation will act synergistically with SA training to improve adaptability by increasing utilization of vestibular information and therefore will help us to optimize and personalize a SA countermeasure prescription. This combination may help to significantly reduce the number of days required to recover functional performance to preflight levels after long-duration spaceflight.

Goel, R.↗

Laboratory Radar Measurements in Support of the NASA Orbital Debris Program Office’s Size Estimation Model

The NASA Orbital Debris Program Office (ODPO) relies on ground-based radar measurements from both the Haystack Ultrawideband Satellite Imaging Radar (HUSIR) and the Goldstone Solar System Radar (Goldstone) to characterize mm to cm debris population in low Earth orbit (LEO). Radar measurements help characterize the size of orbital debris objects, particularly fragmentation debris. However, debris size is not directly measured by radar but inferred from the measured radar cross section (RCS) which depends on several parameters in addition to physical size including electrical conductivity and polarization. To interpret the observed RCS of orbital debris objects detected by radar measurements as physical sizes, NASA uses an empirical size estimation model (SEM) based on laboratory RCS measurements of breakup fragments generated during hypervelocity impact tests as well as some pieces of non-impact-generated “artificial” debris-like objects expected to be representative of the debris population. Since the development of the ODPO SEM, many new materials have been introduced to spacecraft construction. Consequently, ODPO plans to update the radar SEM based on planned laboratory RCS measurements of debris fragments from DebriSat, a ground-based hypervelocity impact experiment conducted in 2014 that consisted of a high-fidelity spacecraft model characteristic of a modern LEO spacecraft. Prior to measuring DebriSat fragments, a set of calibration targets with well-defined geometries and material compositions were measured at The Ohio State University’s ElectroScience Laboratory (OSU-ESL) compact radar range. These calibration measurements help to validate, and understand any limitations of, laboratory measurements of RCS. Calibration targets include idealizations of typical shape categories seen in DebriSat fragments such as nuggets, flat plates, and cylinders. As with DebriSat, calibration target materials were chosen to represent typical modern-day spacecraft components and include stainless steel, aluminum, printed circuit board (PCB) substrate, and carbon fiber-reinforced polymer (CFRP). These materials also represent a wide range of electrical conductivities, which strongly influences measured RCS and inferred target size. The RCS calibration measurements were collected over a frequency sweep from 2 to 18 GHz and stepping through different azimuth angles from 0 to 360 degrees at an elevation of 0 degrees. A second set of calibration measurements is in work consisting of more complex shapes such as bent rods and plates as well as different mounting options including epoxy and a 3D printed holder. These further measurements along with our initial calibration set will inform selection of representative DebriSat fragments for laboratory RCS measurements that will contribute to the planned update to the ODPO radar SEM. An appropriate subset of both the radar calibration and DebriSat samples will also be measured in the ODPO Optical Measurements Center to cross-calibrate size estimates over these different wavelength regimes.

Radar↗

Global Electric Circuit Implications of Combined Aircraft Storm Electric Current Measurements and Satellite-Based Diurnal Lightning Statistics

Using rotating vane electric field mills and Gerdien capacitors, we measured the electric field profile and conductivity during 850 overflights of thunderstorms and electrified shower clouds (ESCs) spanning regions including the Southeastern United States, the Western Atlantic Ocean, the Gulf of Mexico, Central America and adjacent oceans, Central Brazil, and the South Pacific. The overflights include storms over land and ocean, and with positive and negative fields above the storms. Over three-quarters (78%) of the land storms had detectable lightning, while less than half (43%) of the oceanic storms had lightning. Integrating our electric field and conductivity data, we determined total conduction currents and flash rates for each overpass. With knowledge of the storm location (land or ocean) and type (with or without lightning), we determine the mean currents by location and type. The mean current for ocean thunderstorms is 1.7 A while the mean current for land thunderstorms is 1.0 A. The mean current for ocean ESCs 0.41 A and the mean current for land ESCs is 0.13 A. We did not find any significant regional or latitudinal based patterns in our total conduction currents. By combining the aircraft derived storm currents and flash rates with diurnal flash rate statistics derived from the Lightning Imaging Sensor (LIS) and Optical Transient Detector (OTD) low Earth orbiting satellites, we reproduce the diurnal variation in the global electric circuit (i.e., the Carnegie curve) to within 4% for all but two short periods of time. The agreement with the Carnegie curve was obtained without any tuning or adjustment of the satellite or aircraft data. Given our data and assumptions, mean contributions to the global electric circuit are 1.1 kA (land) and 0.7 kA (ocean) from thunderstorms, and 0.22 kA (ocean) and 0.04 (land) from ESCs, resulting in a mean total conduction current estimate for the global electric circuit of 2.0 kA. Mean storm counts are 1100 for land thunderstorms, 530 for ocean ESCs, 390 for ocean thunderstorms, and 330 for land ESCs.

Mach, Douglas M.↗

Qualification of a Multi-Channel Infrared Laser Absorption Spectrometer for Monitoring CO, HCl, HCN, HF, and CO2 Aboard Manned Spacecraft

Monitoring of specific combustion products can provide early-warning detection of accidental fires aboard manned spacecraft and also identify the source and severity of combustion events. Furthermore, quantitative in situ measurements are important for gauging levels of exposure to hazardous gases, particularly on long-duration missions where analysis of returned samples becomes impractical. Absorption spectroscopy using tunable laser sources in the 2 to 5 micrometer wavelength range enables accurate, unambiguous detection of CO, HCl, HCN, HF, and CO2, which are produced in varying amounts through the heating of electrical components and packaging materials commonly used aboard spacecraft. Here, we report on calibration and testing of a five-channel laser absorption spectrometer designed to accurately monitor ambient gas-phase concentrations of these five compounds, with low-level detection limits based on the Spacecraft Maximum Allowable Concentrations. The instrument employs a two-pass absorption cell with a total optical pathlength of 50 cm and a dedicated infrared semiconductor laser source for each target gas. We present results from testing the five-channel sensor in the presence of trace concentrations of the target compounds that were introduced using both gas sources and oxidative pyrolysis (non-flaming combustion) of solid material mixtures.

environmental monitoring↗