Search NASA⌕ Search

SEARCH · Search NASA

Results for “Experimental methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Development, Testing, and Failure Mechanisms of a Replicative Ice Phase Change Material Heat Exchanger

Phase change materials (PCM) may be useful for thermal control systems that involve cyclical heat loads or cyclical thermal environments such as Low Earth Orbit (LEO) and Low Lunar Orbit (LLO). Thermal energy can be stored in the PCM during peak heat loads or in adverse thermal environments. The stored thermal energy can then be released later during minimum heat loads or in more favorable thermal environments. One advantage that PCM s have over evaporators in this scenario is that they do not use a consumable. Wax PCM units have been baselined for the Orion thermal control system and also provide risk mitigation for the Altair Lander. However, the use of water as a PCM has the potential for significant mass reduction since the latent heat of formation of water is approximately 70% greater than that of wax. One of the potential drawbacks of using ice as a PCM is its potential to rupture its container as water expands upon freezing. In order to develop a space qualified ice PCM heat exchanger, failure mechanisms must first be understood. Therefore, a methodical experimental investigation has been undertaken to demonstrate and document specific failure mechanisms due to ice expansion in the PCM. An ice PCM heat exchanger that replicates the thermal energy storage capacity of an existing wax PCM unit was fabricated and tested. Additionally, methods for controlling void location in order to reduce the risk of damage due to ice expansion are investigated. This paper presents the results to date of this investigation.

Leimkuehler, Thomas O.↗

Development, Testing, and Failure Mechanisms of a Replicative Ice Phase Change Material Heat Exchanger

Phase change materials (PCM) may be useful for thermal control systems that involve cyclical heat loads or cyclical thermal environments such as Low Earth Orbit (LEO) and Low Lunar Orbit (LLO). Thermal energy can be stored in the PCM during peak heat loads or in adverse thermal environments. The stored thermal energy can then be released later during minimum heat loads or in more favorable thermal environments. One advantage that PCM's have over evaporators in this scenario is that they do not use a consumable. Wax PCM units have been baselined for the Orion thermal control system and also provide risk mitigation for the Altair Lander. However, the use of water as a PCM has the potential for significant mass reduction since the latent heat of formation of water is approximately 70% greater than that of wax. One of the potential drawbacks of using ice as a PCM is its potential to rupture its container as water expands upon freezing. In order to develop a space qualified ice PCM heat exchanger, failure mechanisms must first be understood. Therefore, a methodical experimental investigation has been undertaken to demonstrate and document specific failure mechanisms due to ice expansion in the PCM. An ice PCM heat exchanger that replicates the thermal energy storage capacity of an existing wax PCM unit was fabricated and tested. Additionally, methods for controlling void location in order to reduce the risk of damage due to ice expansion are investigated. This paper presents the results to date of this investigation. Nomenclature

Leimkuehler, Thomas O.↗

Extraction of Dynamic Inflow Models for Coaxial and Tandem Rotors from CFD Simulations

The dynamic inflow coupling with rotor/body dynamics is crucial in the analysis of stability and control law design for helicopters. Over the past several decades, finite-state inflow models for single rotor configurations in hover, forward flight, and maneuver have developed (Ref.1-3). By capturing the interference effects between rotors, the extension of pressure potential finite state inflow model has promising result for coaxial rotor configuration (Ref.4-6). Recently, the focus of the dynamic inflow modeling has shifted to tandem rotor configurations (Ref.7, 8). The development of the dynamic inflow models for tandem rotor configuration still have some limitations due to the lack of knowledge of rotor-to-rotor interference, and rotor-wake interference. Experimental methods, and computational fluid dynamics methods are commonly used to understand the rotor performance and rotor airload variations, and measure or predict inflow velocity distributions at the rotor desk. The inflow distributions are subsequently used to improve the dynamic inflow models. Tandem rotor configurations have been studied experimentally and computationally for several decades (Ref.9-12). Sweet (Ref.10) observed that a tandem rotor with 76-percent-radius overlap required 14% more induced power at hovering condition, relative to an isolated rotor of equivalent disk area. Sweet also found that, above a shaft-to-shaft distance of 1.03 diameter, the performance of the tandem rotor was nearly the same as two isolated rotors. The objective of the present study is to apply computational fluid dynamics simulations of tandem rotors for the extraction of dynamic inflow models. The extended methodology is first validated by comparing the computed induced power against test data. Subsequently inflow distributions and wake structures are analyzed.

Extraction of Dynamic Inflow Models↗

Methods for determining the internal thrust of scramjet engine modules from experimental data

Methods for calculating zero-fuel internal drag of scramjet engine modules from experimental measurements are presented. These methods include two control-volume approaches, and a pressure and skin-friction integration. The three calculation techniques are applied to experimental data taken during tests of a version of the NASA parametric scramjet. The methods agree to within seven percent of the mean value of zero-fuel internal drag even though several simplifying assumptions are made in the analysis. The mean zero-fuel internal drag coefficient for this particular engine is calculated to be 0.150. The zero-fuel internal drag coefficient when combined with the change in engine axial force with and without fuel defines the internal thrust of an engine.

Voland, Randall T.↗

Durable, Impermeable Brazes for Solid Oxide Fuel Cells (Final Report)

To develop a new braze to replace the current state-of-the-art Ag-CuO reactive air braze (RAB), two approaches were proposed: 1) development of a new, self-passivating, silver-free braze and 2) development of a CuO-free, silver-based braze. For the first approach, an integrated computational-experimental method was used. Thermo-Calc® was utilized to quickly screen through hundreds of alloy systems to identify candidate braze compositions with the appropriate melting ranges. Material compositions, melting ranges, mechanical properties, oxidation resistance, and wetting characteristics of the candidate alloys were then analyzed experimentally. Substrate surface pre-treatments, active element additions, and novel brazing schemes were also investigated. Unfortunately, the current study failed to identify new silver-free braze compositions suitable for SOFC applications. To help measure the passivation characteristics of surface passivating braze oxide coatings, work was conducted to demonstrate, for the first time, that a variety of disparate and technologically-relevant thermal, mechanical, and electrochemical oxygen-exchange thin film material properties could all be obtained from in situ , current-collector-free wafer curvature measurements. Specifically, temperature or oxygen partial pressure induced changes in the curvature of 230 nm thick (100)-oriented Pr 0.1 Ce 0.9 O 1.95_x (10PCO) films atop 200 mm thick single crystal yttria stabilized zirconia or magnesium oxide substrates were used to measure the biaxial modulus, Young’s modulus, thermal expansion coefficient, thermochemical expansion coefficient, oxygen nonstoichiometry, chemical oxygen surface exchange coefficient, oxygen surface exchange resistance, thermal stress, chemical stress, thermal strain, and chemical strain of the model mixed ionic electronic conducting material 10PCO. The (100)-oriented thin film 10PCO thermal expansion coefficient, thermo-chemical expansion coefficient, oxygen nonstoichiometry, and Young’s modulus (which is essentially constant, at ~200 MPa, over the entire 280–700 °C temperature range in air) measured here were similar to those from other bulk and thin film 10PCO studies. In addition, the measured PCO10 oxygen surface coefficients were in agreement with those reported by other in situ , current collector- free techniques. However, the measured PCO10 oxygen surface exchange coefficients were significantly lower than those obtained from literature studies with large amounts of intentional or inadvertent precious metal surface coverage/contamination (suggesting that uncontaminated (100)-oriented 10PCO may not be a desirable SOFC cathode material). Taken together, this highlighted the advantages of using a sample’s mechanical response, instead of the more traditional electrical response, to probe the electrochemical properties of the ion-exchange materials used in solid oxide fuel cell, solid oxide electrolysis cell, gas-sensing, battery, emission control, water splitting, water purification, and other electrochemically-active devices. For the second approach, a novel silver-nickel brazing method was developed. It was demonstrated that transient porous nickel interlayers, instead of reactive element additions, could be used to promote Ag wetting on yttria stabilized zirconia (YSZ) and produce high-quality YSZ stainless steel (SS) braze joints. Mechanical tests on these reactive-element-free, silver-based SOFC braze joints, both before and after 500 hours of 750°C oxidation in air, showed that the braze and braze interface strength were higher than the underlying YSZ|NiO-YSZ substrate. The microstructural and compositional evolution of SS|Ag-Ni|YSZ braze joints exposed to dual atmosphere (air on one side and 4%H 2 -96%N 2 on the other side) for 300 hours of isothermal 750 °C aging and 300 25°C/min 35-830 °C rapid thermal cycles were compared to a Ag-3CuO braze joint. In contrast to conventional Ag-CuO RAB brazes, the Ag-Ni brazes remained pore free and well bonded, suggesting that Ag-Ni brazes may be more suitable for long term SOFC operation than Ag-CuO brazes. Other applications inspired by the silver-nickel wetting process on various ceramic substrates were also explored. In support of efforts to identify new CuO-free Ag-based brazes, density functional theory and ab initio molecular dynamics calculations were performed to 1) understand silver wetting on YSZ, and 2) identify new oxides to promote silver wetting on YSZ. These simulations found that while the formation of dissolved oxygen clusters within molten silver at the YSZ interface promoted wetting, much greater wetting angle reductions came from the formation of metal oxide interlayers at the Ag-YSZ interface. Through the development of a simple descriptor, many simple metal oxides (single cation) were examined. Unfortunately, their ability to promote Ag wetting were less than that of CuO. However, expanding the search to multi-cation oxides led to several promising candidates, such as CuAlO 2 , CuGaO 2 , and Cu 3 TiO 4 ; all of which are also stable in the reducing SOFC conditions. Depending upon their solubility in molten Ag, these newly-identified oxides could either be pre-applied as wetting promoting interlayers or directly incorporated into Ag to form new reactive air brazes.

36 MATERIALS SCIENCE↗

Microwave diagnostics of femtosecond laser-generated plasma filaments

We present a simple non-intrusive experimental method allowing a complete single shot temporal measurement of laser produced plasma filament conductivity. The method is based on filament interaction with low intensity microwave radiation in a rectangular waveguide. The suggested diagnostics allow a complete single shot temporal analysis of filament plasma decay with resolution better than 0.3 ns and high spatial resolution along the filament. The experimental results are compared to numerical simulations, and an initial electron density of 7 x 10{sup 16 }cm{sup -3} and decay time of 3 ns are obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observed physical processes in mechanical tests of PBX9501 and recomendations for experiments to explore a possible plasticity/damage threshold

This memo discusses observations that have been made in regards to a series of monotonic and cyclic uniaxial experiments performed on PBX9501 by Darla Thompson under Enhanced Surveilance Campaign support. These observations discussed in Section Cyclic compression observations strongly suggest the presence of viscoelastic, plastic, and damage phenomena in the mechanical response of the material. In Secton Uniaxial data analysis and observations methods are discussed for separating out the viscoelastic effects. A crude application of those methods suggests the possibility of a critical stress below which plasticity and damage may be negligible. The threshold should be explored because if it exists it will be an important feature of any constitutive model. Additionally, if the threshold exists then modifications of experimental methods may be feasible which could potentially simplify future experiments or provide higher quality data from those experiments. A set of experiments to explore the threshold stress are proposed in Section Exploratory tests program for identifying threshold stress.

36 MATERIALS SCIENCE↗

Acoustic Treatment Design Scaling Methods: Overview, Results, and Recommendations - Volume 1

Scale model fan rigs that simulate new generation ultra-high-bypass engines at about 1/5-scale are achieving increased importance as development vehicles for the design of low-noise aircraft engines. Testing at small scale allows the tests to be performed in existing anechoic wind tunnels, which provides an accurate simulation of the important effects of aircraft forward motion on the noise generation. The ability to design, build, and test miniaturized acoustic treatment panels on scale model fan rigs representative of the fullscale engine provides not only a cost-savings, but an opportunity to optimize the treatment by allowing tests of different designs. The primary objective of this study was to develop methods that will allow scale model fan rigs to be successfully used as acoustic treatment design tools. The study focuses on finding methods to extend the upper limit of the frequency range of impedance prediction models and acoustic impedance measurement methods for subscale treatment liner designs, and confirm the predictions by correlation with measured data. This phase of the program had as a goal doubling the upper limit of impedance measurement from 6 kHz to 12 kHz. The program utilizes combined analytical and experimental methods to achieve the objectives.

Kraft, R. E.↗

Computer Simulation and Experimental Validation on the Oxidation and Sulfate Corrosion Resistance of Novel Chromium Based High Temperature Alloys

This report summarizes our recent works of ab initio molecular dynamics inter-atomic potentials development on dilute rare earth element yttrium (Y) etc. doped chromium (Cr) alloy systems, its applications in oxidation and corrosion resistance simulation, and experiment validation on the candidate systems. The simulation methods, experimental validation techniques, achievements already reached, students training, and future improvement are briefly introduced.

36 MATERIALS SCIENCE↗

Consideration of temperature-dependent emissivity of selective emitters in thermophotovoltaic systems

Spectral emissivity control is paramount for designing a high-efficiency selective emitter surface required for thermophotovoltaic (TPV) applications. Owing to the temperature dependency of materials optical constants, the spectral properties of a selective emitter surface changes with the emitter temperature. This paper presents the fabrication of a multilayer metal-dielectric ( ${\rm Si}_{3}{\rm N}_{4}/\rm W/Si_{3}{\rm N_{4}}$ ) coated tungsten selective emitter aimed for GaSb-based TPV systems and studies the dependence of its surface spectral emissivity, $\varepsilon (\lambda)$ , upon a temperature ranging from 300 K to 1500 K. Both the simulation and experimental methods were used to characterize $\varepsilon (\lambda)$ as a function of temperature. For wavelengths less than 1.4 µm, $\varepsilon (\lambda)$ was found to have a minimal dependence on temperature. Beyond 1.4 µm, $\varepsilon (\lambda)$ increases with the temperature. At 1.55 µm, the simulation and experimental data estimated a ${\sim}{{4}}\%$ greater emissivity at 1500 K than at room temperature. At 1500 K, the increased $\varepsilon (\lambda)$ at longer wavelengths lowered the spectral conversion efficiency of the selective emitter from 58% to 47%. The output power density, sub-bandgap loss, and TPV conversion efficiency ( ${\eta _{\rm TPV}}$ ) for a GaSb cell illuminated by the selective thermal emitter at 1500 K were estimated. ${\eta _{\rm TPV}}$ drops from 13.7% to 11% due to the increased sub-bandgap emission at 1500 K. Essential approaches for mitigating the sub-bandgap losses to further improve ${\eta _{\rm TPV}}$ are also discussed.

42 ENGINEERING↗

Ring Resonator for Detection of Melting Brine Under Shallow Subsurface of Mars

Laboratory experimental evidence using Raman spectroscopy has shown that liquid brine may form below the shallow subsurface of Mars. A simpler experimental method to verify the presence of liquid brine or liquid water below Mars surface is needed. In this paper, a ring resonator is used to detect the phase change between frozen water and liquid water below a sandy soil that simulates the Mars surface. Experimental data shows that the ring resonator can detect the melting of thin layers of frozen brine or water up to 15 mm below the surface.

brine↗

Ring Resonator for Detection of Melting Brine Under Shallow Subsurface of Mars

Laboratory experimental evidence using Raman spectroscopy has shown that liquid brine may form below the shallow subsurface of Mars. A simpler experimental method to verify the presence of liquid brine or liquid water below Mars surface is needed. In this paper, a ring resonator is used to detect the phase change between frozen water and liquid water below a sandy soil that simulates the Mars surface. Experimental data shows that the ring resonator can detect the melting of thin layers of frozen brine or water up to 15 mm below the surface.

Mars↗

Construction and Commissioning of Gas Electron Multiplier (GEM) Detectors in Advanced Assembly Design for Low-Energy Applications at High Rates and Analysis of GEM Data From the Muse Experiment at PSI

The search beyond the Standard Model explores dark matter and a potential fifth force. DarkLight@ARIEL investigates the dark photon as a mediator between ordinary and dark matter. The experiment aims to measure the process e?Ta ? e?TaX ? e?Ta(e?e+), by detecting a charged lepton pair in the final state. The spectrometers will be instrumented with Gas Electron Multiplier (GEM) detectors with minimal material budget for tracking. A novel GEM construction technique is employed for fabricating 25 cm x 40 cm GEM detectors, where all layers are mechanically stretched and assembled within a double frame. The dissertation outlines physics motivation, methods, experimental setup, and the role of GEM detectors in DarkLight. A comprehensive discussion on GEM detectors, focusing on the "NS2" technique, including design, parts, assembly, testing, and performance evaluation will be discussed. The proton has garnered attention due to discrepancies in measuring its charge radius using muonic hydrogen and electron-based methods. The 2010 muonic hydrogen measurement of the proton charge radius Rp = 0.84184(67) fm, showed a significant 7? discrepancy compared to the previously known value of Rp = 0.8775(51) fm, giving rise to the proton radius puzzle. Through simultaneous measurements of e ? p and ? ? p elastic scattering, MUSE facilitates a precise and direct comparison of the proton radius. The physics background of the proton radius puzzle, measurement techniques, the approach adopted by the MUSE experiment, its significance and the experimental setup will be discussed. Furthermore, the role of GEM detectors, along with an in-depth analysis of their data and efficiency will be discussed and evaluated.

Mohammed Prem Nazeer, Sahara↗

X-ray Methods in High-Intensity Discharges and Metal-Halide Lamps: X-ray Induced Fluorescence

We describe the use of x-ray induced fluorescence to study metal-halide high-intensity discharge lamps and to measure equilibrium vapor pressures of metal-halide salts. The physical principles of metal-halide lamps, relevant aspects of x-ray-atom interactions, the experimental method using synchrotron radiation, and x-ray induced fluorescence measurements relevant to metal-halide lamps are covered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method To Determine MgO and MgOHCl in Chloride Molten Salts

A commercial blend of mainly carnallite (KCl∙MgCl 2 ∙6H 2 O) is considered as a next-generation heat transfer fluid in solar thermal plants. Corrosive properties of MgCl2 hydrates must be addressed at the operating temperatures of 500-720 degrees C. For successful chemical monitoring of the carnallite heat transfer fluid, an experimental method was developed to separate and titrate for MgO and MgOHCl from solid carnallite. This new method was assessed for error and accuracy. The method's relative error for MgOHCl was -7.0% for a mass fraction of 9.0 wt % MgOHCl in the carnallite salt. The method's relative error for MgO was less than +1.0% for a mass fraction of 12.0 wt % MgO in the carnallite salt. Titration results were used to track changes in the MgOHCl concentration in carnallite salt through the carnallite's dehydration and purification.

14 SOLAR ENERGY↗

Simple method for highlighting the temperature distribution into a liquid sample heated by microwave power field

Microwave induced heating is widely used in medical treatments, scientific and industrial applications. The temperature field inside a microwave heated sample is often inhomogenous, therefore multiple temperature sensors are required for an accurate result. Nowadays, non-contact (Infra Red thermography or microwave radiometry) or direct contact temperature measurement methods (expensive and sophisticated fiber optic temperature sensors transparent to microwave radiation) are mainly used. IR thermography gives only the surface temperature and can not be used for measuring temperature distributions in cross sections of a sample. In this paper we present a very simple experimental method for temperature distribution highlighting inside a cross section of a liquid sample, heated by a microwave radiation through a coaxial applicator. The method proposed is able to offer qualitative information about the heating distribution, using a temperature sensitive liquid crystal sheet. Inhomogeneities as smaller as 1°-2°C produced by the symmetry irregularities of the microwave applicator can be easily detected by visual inspection or by computer assisted color to temperature conversion. Therefore, the microwave applicator is tuned and verified with described method until the temperature inhomogeneities are solved.

36 MATERIALS SCIENCE↗

A comparison of temperature and humidity effects on phosphor-converted LED packages and the prediction of remaining useful life with state estimation

This paper focuses on the failure mechanisms and color stability of a commercially available high power LED under harsh environmental conditions. 3 groups of the same pc-HB warm white LED were used in the experiment. The first group was subjected to both high temperature and high relative humidity (85°C/85%RH) with a 350mA bias current. The second group was subjected to only temperature stress at 105°C with a 350mA bias current. The last group was subjected to extreme high temperature 175°C and high bias current (500mA). Samples were taken out from the chamber for both photometric and colorimetric analysis at periodic intervals to investigate the change of the optical parameters. The physics of failure due to the material degradation has been correlated with the change in the photometric and colorimetric parameters of the LED packages. At the end of the experiment, 6000 hours of data is projected forward with state estimation methods to compare with projections made with the TM-21 method. Experimental results shows that only optical parts degrades at high temperature conditions. However, at both high temperature and high relative humidity condition, the phosphor layer of the pc-LED can swell and the color stability of LEDs degrades significantly. Also, comparison between TM-21 method and state estimation method shows that state estimation can achieve the same goal with a relatively easy method.

Lall, Pradeep↗