Search NASA⌕ Search

SEARCH · Search NASA

Results for “FOCUSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A Transmittance-optimized, Point-focus Fresnel Lens Solar Concentrator

The development of a point-focus Fresnel lens solar concentrator for high-temperature solar thermal energy system applications is discussed. The concentrator utilizes a transmittance-optimized, short-focal-length, dome-shaped refractive Fresnel lens as the optical element. This concentrator combines both good optical performance and a large tolerance for manufacturing, deflection, and tracking errors. The conceptual design of an 11-meter diameter concentrator which should provide an overall collector efficiency of about 70% at an 815 C (1500 F) receiver operating temperature and a 1500X geometric concentration ratio (lens aperture area/receiver aperture area) was completed. Results of optical and thermal analyses of the collector, a discussion of manufacturing methods for making the large lens, and an update on the current status and future plans of the development program are included.

Oneill, M. J.↗

Orbiter radiator panel solar focusing test

Test data are presented which define the area around the Orbiter radiator panels for which the solar reflections are concentrated to one-sun or more. The concave shape of the panels and their specular silver/Teflon coating causes focusing of the reflected solar energy which could have adverse heating effects on equipment or astronaut extravehicular activity (EVA) in the vicinity of the radiator panels. A room ambient test method was utilized with a one-tenth scale model of the radiator panels.

Howell, H. R.↗

The effect of concentrator field layout on the performance of point-focus distributed receiver systems

The effect of concentrator field layout on the technical-economic performance of a point-focusing distributed receiver (PFDR) solar thermal power plant is presented. The plant design is based on the small community prototype system currently under development for JPL/DOE; parabolic dish concentrators are employed, and small heat engines are used to generate electricity at each dish. The effect of field size, array proportions, dish-to-dish spacing and packing fraction (concentrator-land area ratio) are presented for typical PFDR layouts. Economic analyses are carried out to determine optimum packing fraction as a function of site cost.

Pons, R. L.↗

Oblique focus ICCD laboratory evaluation

An oblique focus intensified charge coupled device (ICCD) was constructed and operated in a vacuum system. Special gratings were obtained and an optical system set up to try to model a candidate UV spectrometer (Milieu Interstellaire et Intergalactique-MISIG), and to produce small enough images to test the theoretical subpixel resolution capability of the ICCD system. The efforts were only partly successful. Based on the results, a similar detector was built and flown successfully on a Princeton rocket program.

York, D. G.↗

High-performance double-focusing mass spectrometer

Double focusing was first employed when mass spectrometers of a simpler design were not capable any longer to satisfy increasing demands in mass spectroscopy. One of the successful instruments of the 1930's was the mass spectrometer designed by Mattauch and Herzog (1934). The compactness of the Mattauch-Herzog geometry became particularly important in connection with studies involving the employment of rockets, satellites, or space probes. Another advantage of the considered spectrometer is related to the capability of measuring several masses of ions simultaneously. The instrument design was, therefore adopted for some rocket flights to the upper atmosphere, the investigation of the upper atmosphere of Mars, and for studying the upper atmosphere of Venus. Attention is given to laboratory applications involving the instrument in a somewhat enlarged version, and aspects of instrument operation and performance.

Nier, A. O.↗

Rotating Apparatus for Isoelectric Focusing

Remixing of separated fractions prevented. Improved isoelectric focusing apparatus helps to prevent electro-osmosis and convection, both of which cause remixing of separated fractions. Fractionating column segmented and rotated about horizontal axis: Only combined effects of both features fully effective in making good separations. Improved apparatus slowly rotated continuously or rocked (at rotational amplitude of at least 180 degrees) about its horizontal axis so average gravitational vector experienced by fluid is zero and convection is therefore suppressed. Electro-osmosis suppressed and convection further suppressed by separating column into disklike compartments along its length with filters. Experiments have shown dimensions of apparatus not critical. Typical compartment and column volumes are 2 and 40 ml, respectively. Rotation speeds lie between 3 and 30 rpm.

Bier, M.↗

Hormone Purification by Isoelectric Focusing

Various ground-based research approaches are being applied to a more definitive evaluation of the natures and degrees of electroosmosis effects on the separation capabilities of the Isoelectric Focusing (IEF) process. A primary instrumental system for this work involves rotationally stabilized, horizontal electrophoretic columns specially adapted for the IEF process. Representative adaptations include segmentation, baffles/screens, and surface coatings. Comparative performance and development testing are pursued against the type of column or cell established as an engineering model. Previously developed computer simulation capabilities are used to predict low-gravity behavior patterns and performance for IEF apparatus geometries of direct project interest. Three existing mathematical models plus potential new routines for particular aspects of simulating instrument fluid patterns with varied wall electroosmosis influences are being exercised.

Bier, M.↗

SS focused technology: Gateways and NOS's

The extensions and enhancements of the fiber optic data bus technology supported by the Space Station Focused Technology Program are discussed. This includes the operating software for the network called the Network Operating System (NOS); gateways and bridges for multiple network topologies; and very large scale topology implimentations to shrink the size and power of the Bus Interface Unit (BIU) down to more manageable dimensions. CMOS is being investigated for the lower speed (parallel) logic. Gallium arsendide is being studied for the high speed (serial) logic.

Hartenstein, R.↗

Focusing anisotropy of solar cosmic rays

Analysis of 50-MeV particle data from ICE and 1-GeV data from eight high-latitude neutron monitors of the February 16, 1984 solar cosmic ray event indicates that an exponential with scattering mean free path of greater than 2 AU and with index in the 1.3-1.7 range provides a better description of particle anisotropies than the first-order form, confirming the prediction from cosmic ray transport theories which incorporate the effect of adiabatic focusing into the usual pitch angle scattering formalism. The time profile of the event is largely a reflection of coronal transport processes, with good fits provided by a coronal diffusion coefficient of about 10 to the 18th sq cm/s and with velocity-dependent escape. The simple method of predicting the interplanetary scattering parameters has application where particle injection is nearly continuous, but where previously accelerated particles have filled the heliosphere with a large omnidirectional background.

Bieber, J. W.↗

Isoelectric focusing of dansylated amino acids in immobilized pH gradients

The 21 free amino acids commonly encountered in proteins have been transformed into 'carrier ampholyte' species by reacting their primary amino groups with dansyl chloride. These derivatives can thus be focused in an immobilized pH gradient covering the pH interval 3.1 to 4.1, except for arginine, which still retains a pI of 8.8. Due to their inherent fluorescence, the dansyl derivatives are revealed in UV light, with a sensitivity of the order of 2-4 ng/sq mm. All nearest neighbors are separated except for the following couples: Asn-Gln, Gly-Thr, Val-Ile and Cys-Cys2, with a resolving power, in a Delta(pI) scale, of the order of 0.0018 pH units. Except for a few cases (notably the aromatic amino acids), the order of pI values is well correlated with the pK values of carboxyl groups, suggesting that the latter are not altered by dansylation. From the set of pK(COOH)-pI values of the different amino acids, the pK of the tertiary amino group in the dansyl label has been calculated to be 5.11 + or - 0.06. Knowing the pK of the amino-dansyl and the pI of the excess, free dansyl label (pI = 3.34), a pK of 1.57 is derived for its sulfonic acid group.

Bianchi-Bosisio, Adriana↗

Computer simulation of two electrophoretic columns coupled for isoelectric focusing in simple buffers

Computer simulation is used to analyze a system of two electrophoretic columns coupled by mixing the anolyte of one with the catholyte of the other. A mathematical model is presented which is used to predict the pH gradients formed by monovalent buffers in this system, when the currents in the columns are unequal. In the column with the higher current a pH gradient is created which increases from anode to cathode and is potentially useful for isoelectric focusing. The breadth of this gradient is dependent upon the ratio of the currents. The function of the second column is the compensation of buffer migration which occurs in the first column, thereby maintaining constant electrolyte composition. The effects of buffer pKs and mobilities are evaluated.

Tsai, Amos↗

The formation of stable pH gradients with weak monovalent buffers for isoelectric focusing in free solution

Two methods which utilize simple buffers for the generation of stable pH gradients (useful for preparative isoelectric focusing) are compared and contrasted. The first employs preformed gradients comprised of two simple buffers in density-stabilized free solution. The second method utilizes neutral membranes to isolate electrolyte reservoirs of constant composition from the separation column. It is shown by computer simulation that steady-state gradients can be formed at any pH range with any number of components in such a system.

Mosher, Richard A.↗

Scale-up of isoelectric focusing

The paper describes some applications to large scale protein fractionation using a recycling isoelectric focusing apparatus. Separation is achieved in free solution without the use of supporting media. Various alternatives for the formation of the pH gradient are discussed and results of a computer simulation are presented.

Bier, Milan↗

Isoelectric focusing-affinity immunoblot analysis of mouse monoclonal antibodies to the four human IgG subclasses

Isoelectric focusing (IEF)/affinity immunoblotting and enzyme-linked immunosorbent assay (ELISA) were used for parallel analysis of murine monoclonal antihuman IgG-subclass antisera (MoAbs). Coomassie Blue-stained protein bands in the pH region 5.5-8.0 were shown to be murine IgG by direct blotting onto nitrocellulose followed by detection with conjugated antimouse IgG. Use of IgG myeloma antigen-coated nitrocellulose in the IEF-affinity immunoblot allowed detection of the charge microheterogeneity of MoAbs. The MoAb group contained one to five major dense bands flanked by up to four minor fainter bands, all with pIs ranging from 6.1 to 7.8. Semiquantitative estimates of binding specificity in the IEF-affinity blot compared well with cross-reactivity data obtained from a quantitative ELISA.

Hamilton, Robert G.↗

Affinity immunoblotting - High resolution isoelectric focusing analysis of antibody clonotype distribution

A sensitive and specific method is proposed for the analysis of specific antibody clonotype changes occurring during an immune response and for comparing multiple sera for antibody clonotype similarities. Polyclonal serum antibodies separated by isoelectric focusing (IEF) were analyzed by an affinity immunoblotting method using antigen-coated nitrocellulose membranes. Antibodies present on the surface of the acrylamide gels following IEF bind the antigen on the nitrocellulose when the coated nitrocellulose is laid over the gels. The technique has been used to analyze Ig clonotypes specific for five protein antigens and two carbohydrate antigens. Optimal antigen concentrations for coating the nitrocellulose membranes were found to range from 10-100 microgram/ml.

Knisley, Keith A.↗

Statistical treatment of fluctuations in the gravitational focusing of light due to stellar masses within a gravitational lens

When light from small, distant sources in the universe is gravitationally focused by an intervening galaxy, the gravitational lens can be influenced by the granularity of the matter distribution which is caused by the stellar (or other compact) masses in the galaxy. A largely analytic, statistical calculation for a gravitational lens due to a collection of compact masses - valid for sources of finite size and for large (as well as small) 'optical depths' for the lens - is developed to treat fluctuations in the light caused by such 'microfocusing' effects. Previous treatments have been either numerical simulations of the Monte Carlo type or limited to single-star (i.e., low-optical-depth) effects.

Deguchi, Shuji↗

Characterization of synthetic carrier ampholytes by repetitive scanning of the electric field during focusing

This paper reports the utilization of a potential gradient array detector for monitoring the dynamics of the electric field during isoelectric focusing. Transient and steady state electric field profiles are presented for synthetic carrier ampholyte mixtures with a wide (about 3-10) pH range. Two available commercial products (Ampholine and Pharmalyte) and a laboratory synthesized mixture (PEHA ampholytes) are compared. The formation of conductivity gaps and their migration toward the cathode in extended experiments (cathodic drift) can be visualized with this system.

Thormann, W.↗

Space Station - A focus for the development of structural dynamics scale model technology for large flexible space structures

The paper discusses the scale model technology being developed at the NASA Langley Research Center in support of the development of structural dynamic prediction methods for large flexible space structures. Space Station is used as a focus. The Dynamic Scale Model Technology (DSMT) Program is described; results of the effect of scaling Space Station components are presented; and supporting scale model technology development activities are described and results presented. The conceptual design of a hybrid-scale Pathfinder model for developing test techniques and suspension methods is also discussed, and a summary of the broad application of the scale model technology being developed is presented.

Letchworth, Robert↗