Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Gravitational Wave Search with the Clock Mission (abstract)

Doppler tracking of distant spacecraft is the only method currently available for search for gravitational waves in the low-frequency band. Experiments to date and those planned for the near future all involve.

clocks gravitational waves doppler frequency stand↗

Reply to Mr. Silvertooth's Letter

The JPL experiment is indeed similar in spirit to that of Cialdea, but not the earlier MIT experiments (which involved the comparison of laser cavities).

Cialdea MIT experiments atomic frequency standards↗

Measurements of Line Positions and Strengths of HD O-18 and D2 O-18 in the 2500-4280 cm(exp -1) Region

Measurements of line positions and strengths of D2 O-18 and HD O-18 were obtained with a Fourier transform spectrometer. The data were analyzed to obtain energy levels of the (100), (020), and (001) vibrational states of HD O-18 and the (001) and (011) states of D2 O-18 and the vibrational bands of these states connected to the ground state covered the spectral region from 2500 to 4278 cm(exp -1). 456 absorption lines of D2 O-18 and 856 lines of HD O-18 were assigned from the spectra. The measurements were of oxygen-18 enriched samples of deuterated water vapor and the spectra also contained features of HD O-16, D2 O-16, H2 O-16, H2 O-17 and H2 O-18 of which several were used as frequency calibration standards.

Fourier transform spectrometer (FTS)↗

The Transitional Protoplanetary Disk Frequency as a Function of Age: Disk Evolution in the Coronet Cluster, Taurus, and Other 1--8 Myr-old Regions

We present Spitzer 3.6-24 micron photometry and spectroscopy for stars in the 1-3 Myr-old Coronet Cluster, expanding upon the survey of Sicilia-Aguilar et al. (2008). Using sophisticated radiative transfer models, we analyze these new data and those from Sicilia-Aguilar et al. (2008) to identify disks with evidence for substantial dust evolution consistent with disk clearing: transitional disks. We then analyze data in Taurus and others young clusters - IC 348, NGC 2362, and eta Cha -- to constrain the transitional disk frequency as a function of time. Our analysis confirms previous results finding evidence for two types of transitional disks -- those with inner holes and those that are homologously depleted. The percentage of disks in the transitional phase increases from approx.15-20% at 1-2 Myr to > 50% at 5-8 Myr; the mean transitional disk lifetime is closer to approx. 1 Myr than 0.1-0.5 Myr, consistent with previous studies by Currie et al. (2009) and Sicilia-Aguilar et al. (2009). In the Coronet Cluster and IC 348, transitional disks are more numerous for very low-mass M3--M6 stars than for more massive K5-M2 stars, while Taurus lacks a strong spectral type-dependent frequency. Assuming standard values for the gas-to-dust ratio and other disk properties, the lower limit for the masses of optically-thick primordial disks is Mdisk approx. 0.001-0.003 M*. We find that single color-color diagrams do not by themselves uniquely identify transitional disks or primordial disks. Full SED modeling is required to accurately assess disk evolution for individual sources and inform statistical estimates of the transitional disk population in large samples using mid-IR colors.

Currie, Thayne↗

Sub-mm Scale Fiber Guided Deep/Vacuum Ultra-Violet Optical Source for Trapped Mercury Ion Clocks

We demonstrate the functionality of a mercury capillary lamp with a diameter in the sub-mm range and deep ultraviolet (DUV)/ vacuum ultraviolet (VUV) radiation delivery via an optical fiber integrated with the capillary. DUV spectrum control is observed by varying the fabrication parameters such as buffer gas type and pressure, capillary diameter, electrical resonator design, and temperature. We also show spectroscopic data of the 199Hg+ hyper-fine transition at 40.5GHz when applying the above fiber optical design. We present efforts toward micro-plasma generation in hollow-core photonic crystal fiber with related optical design and theoretical estimations. This new approach towards a more practical DUV optical interface could benefit trapped ion clock developments for future ultra-stable frequency reference and time-keeping applications.

lamps↗

Time and Laser Ranging: A Window of Opportunity for Geodesy, Navigation and Metrology

Recent progress in the domain of time and frequency (T/F) standards requires important improvements of existing time distribution links. Among these, the accuracy of time transfer is actually an important part of the concerns in order to establish and maintain time & space references from ground and/or space facilities. Several time transfers by laser link projects have been carried out over the past 10 years with numerous scientific and metrological objectives. Satellite Laser ranging (SLR) has proven to be a fundamental tool, offering a straightforward, conceptually simple, highly accurate and unambiguous observable. Depending on the mission, LR is used to transmit time over two-way or one-way distances from 500 to several millions of km. The following missions and their objectives employed this technique: European Laser Timing (ELT) at 450 km, Time Transfer by Laser Link (T2L2) at 1,336 km, Laser Time Transfer (LTT) at 36,000 km, Lunar Reconnaissance Orbiter (LRO) at 350,000 km, and MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) at tens of million km. This article describes the synergy between SLR and T/F technologies developed on the ground and in space and as well as the state of the art of their exploitation. The performance and sources of limitation of such space missions are analyzed. It shows that current and future challenges lie in the improvement of the time accuracy and stability of the time for ground geodetic observatories. The role of the next generation of SLR systems is emphasized both in space and at ground level, from the point of view of GGOS and valuable exploitation of the synergy between time synchronization, ranging and data transfer.

P. Exertier↗

Time and Laser Ranging: A Window of Opportunity for Geodesy, Navigation, and Meteorology

Recent progress in the domain of time and frequency (T/F) standards requires important improvements in existing timedistribution links, in term of accuracy in particular. Satellite Laser Ranging (SLR) has proven to be a fundamental tool,offering a straightforward, conceptually simple, highly accurate, and unambiguous observable. Several time transfers by laserlink projects have been carried out over the past 10 years with numerous scientific and metrological objectives. Depending on the mission, SLR is used to transmit time over two-way or one-way distances from 500 to several millions of kilometers.The following missions and their objectives employed this technique: European Laser Timing (ELT, expected in 2020) at 450 km, Time Transfer by Laser Link (T2L2) at 1336 km, Laser Time Transfer at 36,000 km, Lunar Reconnaissance Orbiter at 350,000 km, and MErcury Surface, Space ENvironment, GEochemistry, and Ranging at tens of million km. This article describes the synergy between SLR and T/F technologies developed on the ground and in space and as well as the state of the art of their exploitation. The performance and sources of limitation of such space missions are analyzed. It shows that currentand future challenges lie in the improvement in the time accuracy and stability of the time for ground geodetic observatories.The role of the next generation of SLR systems is emphasized both in space and at ground level, from the point of view of Global Geodetic Observing System and valuable exploitation of the synergy between time synchronization, ranging, and data transfer.

Laser ranging↗

In Situ Chemical Reduction Interim Measures Work Plan Hot Spot 3 Mobile Launcher Platform Rehabilitation Sites / Vehicle Assembly Building Area (SWMU 056) Kennedy Space Center, Florida

This document presents the design details of an In Situ Chemical Reduction (ISCR) Interim Measures Work Plan for Hot Spot 3 within Mobile Launcher Platform Rehabilitation Sites/Vehicle Assembly Building Area, Solid Waste Management Unit (SWMU) 056 (SWMU 056), located at the John F. Kennedy Space Center, Florida. The interim measures (IM) treatment zone encompasses an area identified as the High Concentration Plume (HCP), which is defined as the area with chlorinated volatile organic compound (CVOC) groundwater concentrations greater than their respective Natural Attenuation Default Concentration (NADC). The objective of the IM is to remove CVOC mass within the treatment area to levels that facilitate a transition to natural attenuation monitoring. The IM design consists of the selected ISCR amendment, Provect-IR, which is a mixture of solid reagents in a single product that promotes enhanced reductive dechlorination and ISCR. ProvectIR includes natural antimethanogenic compounds; multiple hydrophilic, nutrient-rich organic carbon sources; zero valent iron; chemical oxygen scavengers; and vitamin and mineral sources. The proposed treatment area for this IM encompasses less than 1 acre and includes three vertical treatment intervals to reach the NADC plumes that vary per CVOC and depth: 4 to 10 feet below land surface (bls), 10 to 18 feet bls, and 42 to 52 feet bls. The amendment will be distributed through 16 injection points (IP01 through IP16) using dosing rates ranging from 0.4% to 0.6% of soil mass within the treatment interval and a 15% or 20% slurry strength. Dosage rates and slurry strength are based on groundwater geochemistry, soil characteristics, and contaminant concentrations. To aid in the evaluation of the ISCR IM performance, six performance monitoring wells will be installed following injections and sampled semiannually. CVOC parameters will be sampled until concentrations reduce to below their NADC. Underground Injection Control parameters will be sampled until concentrations decrease to background levels or to levels that meet respective groundwater standards. Sampling frequency will be evaluated annually and modified as needed. The path forward for the ISCR IM implementation includes preparing the IM Implementation Work Plan, ISCR injections, monitoring well installation, performance monitoring, and reporting.

Randall K. Sillan↗