Search NASA⌕ Search

SEARCH · Search NASA

Results for “Frequency spectrum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Seedless nonresonant gas-flow velocimetry with single-shot coherent Rayleigh-Brillouin scattering

We demonstrate neutral gas-flow velocimetry by exploiting the optical dipole forces exerted by precisely tailored high-intensity laser fields on polarizable particles, in the form of single-shot coherent Rayleigh-Brillouin scattering (CRBS). This enables mapping of the velocity distribution function of the particles in a single laser shot of approximately 200 ns duration, allowing us to perform spectroscopic measurements in the time, rather than the frequency, domain. Importantly, CRBS results in a coherent signal beam, which renders the technique ideal for measurements in optically noisy environments. By correlating the time shift of the resulting spectrum to the Doppler shift caused by the bulk motion of particles, we perform neutral gas-flow velocimetry without the need to seed the flow, nondestructively, for a variety of gases, atomic or molecular. We demonstrate gas-flow velocimetry at flow velocities as low as 1 m ⁢s −1 , with similar velocity resolution, while temperature and gas density can also be estimated from the same single-shot spectra. To prove the effectiveness of the measurement technique, we benchmark it against Pitot tube measurements, which show excellent agreement.

Gerakis, Alexandros [Luxembourg Institute of Scien↗

Impedance Response Influenced by Variability in the Random Distribution of Physical Properties of Coated Materials in Two-Dimensional Space

Heterogeneous physical characteristics of a system featuring a single-layer film on a metallic surface have been explored via its impedance response. The Nyquist plot showed a distorted semicircle, indicative of the system's unique distribution characteristics. Utilizing a copula-based probability method, a two-dimensional deterministic impedance model was successfully integrated, accounting for spatial physical properties such as permittivity and electrical conductivity. This strategy enabled in-depth exploration and mechanistic quantification of a broad spectrum of properties. A quantitative understanding of impedance signal alterations, characterized by normally or log-normally correlated variables, was achieved through the variation in aspect ratio and characteristic frequency of the impedance spectra. Log-normally distributed electrical properties provided a superior representation of the distorted impedance spectra. As coefficient of variation (CV) values fluctuated, the aspect ratio and characteristic frequency showed heightened sensitivity to log-normal permittivity compared to log-normal electrical conductivity. Notably, a marked positive linear correlation between electrical properties resulted in an impedance response that approximated perfect semicircular spectra. The variability in the electrical properties' distribution was demonstrated by considering the correlation coefficient between electrical conductivity and the z-direction position. Furthermore, the highest aspect ratio of the impedance spectra was observed when the electrical conductivity was randomly distributed across the z-direction space.

36 MATERIALS SCIENCE↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-Time Data Acquisition and Processing System for MHz Repetition Rate Image Sensors

An electro-optic detector is one of the diagnostic setups used in particle accelerators. It employs an electro-optic crystal to encode the longitudinal beam charge profile in the spectrum of a light pulse. The charge distribution is then reconstructed using data captured by a fast spectrometer. The measurement repetition rate should match or exceed the machine bunching frequency, which is often in the range of several MHz. A high-speed optical line detector (HOLD) is a linear camera designed for easy integration with scientific experiments. The use of modern FPGA circuits helps in the efficient collection and processing of data. The solution is based on Xilinx 7-Series FPGA circuits and implements a custom latency-optimized architecture utilizing the AXI4 family of interfaces. HOLD is one of the fastest line cameras in the world. Thanks to its hardware architecture and a powerful KALYPSO sensor from KIT, it outperforms the fastest comparable commercial devices.

MicroTCA↗

Spectrally reconfigurable quantum emitters enabled by optimized fast modulation

The ability to shape photon emission facilitates strong photon-mediated interactions between disparate physical systems, thereby enabling applications in quantum information processing, simulation and communication. Spectral control in solid state platforms such as color centers, rare earth ions, and quantum dots is particularly attractive for realizing such applications on-chip. Here we propose the use of frequency-modulated optical transitions for spectral engineering of single photon emission. Using a scattering-matrix formalism, we find that a two-level system, when modulated faster than its optical lifetime, can be treated as a single-photon source with a widely reconfigurable photon spectrum that is amenable to standard numerical optimization techniques. To enable the experimental demonstration of this spectral control scheme, we investigate the Stark tuning properties of the silicon vacancy in silicon carbide, a color center with promise for optical quantum information processing technologies. We find that the silicon vacancy possesses excellent spectral stability and tuning characteristics, allowing us to probe its fast modulation regime, observe the theoretically-predicted two-photon correlations, and demonstrate spectral engineering. Our results suggest that frequency modulation is a powerful technique for the generation of new light states with unprecedented control over the spectral and temporal properties of single photons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing the electronic structure and spectroscopy of pyrrolyl and imidazolyl radicals using high-resolution photoelectron imaging of cryogenically cooled anions

High-resolution photoelectron imaging and photodetachment spectroscopy of cryogenically cooled pyrrolide and imidazolide anions are used to probe the electronic structure and spectroscopy of pyrrolyl and imidazolyl radicals. The high-resolution data allow the ground state vibronic structures of the two radicals to be completely resolved, yielding accurate electron affinities of 2.1433 ± 0.0008 eV and 2.6046 ± 0.0006 eV for pyrrolyl and imidazolyl radicals, respectively. Fundamental frequencies for eight vibrational modes of pyrrolyl and ten vibrational modes of imidazolyl are measured, including several nonsymmetric Franck–Condon-forbidden modes. Two electronic excited states are also observed for the two radicals, displaying diffuse spectral features in both systems. The observations of nonsymmetric vibrational modes in the ground states and the diffuse excited state features provide strong evidence for vibronic couplings between the ground state and the two close-by excited states. The 2-pyrrolide isomer is also observed as a minor species from the electrospray ionization source and the electron affinity of 2-pyrrolyl is measured to be 1.6690 ± 0.0030 eV along with five vibrational frequencies. Even though the HOMOs of both pyrrolide and imidazolide anions are p orbitals, photodetachment spectroscopy reveals completely different threshold behaviors for the two anions: a d-wave-dominated spectrum for pyrrolide and an s-wave-dominated spectrum for imidazolide. Furthermore, the current study provides a wealth of electronic and spectroscopic information, which is ideal to compare with more accurate vibronic coupling calculations for these two important radicals, as well as interesting information about the photodetachment dynamics of the two anions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Planck constraints on the tensor-to-scalar ratio

In this work, we present constraints on the tensor-to-scalar ratio r using Planck data. We use the latest release of Planck maps (PR4), processed with the NPIPE code, which produces calibrated frequency maps in temperature and polarization for all Planck channels from 30 GHz to 857 GHz using the same pipeline. We computed constraints on r using the BB angular power spectrum, and we also discuss constraints coming from the TT spectrum. Given Planck's noise level, the TT spectrum gives constraints on r that are cosmic-variance limited (with $\sigma$ r = 0.093), but we show that the marginalized posterior peaks towards negative values of r at about the 1.2$\sigma$ level. We derived Planck constraints using the BB power spectrum at both large angular scales (the 'reionization bump') and intermediate angular scales (the 'recombination bump') from $\ell$=2 to 150, and find a stronger constraint than that from TT, with $\sigma$ r = 0.069. The Planck BB spectrum shows no systematic bias, and is compatible with zero, given both the statistical noise and the systematic uncertainties. The likelihood analysis using B modes yields the constraint r < 0.158 at 95% confidence using more than 50% of the sky. This upper limit tightens to r < 0.069 when Planck EE, BB, and EB power spectra are combined consistently, and it tightens further to r < 0.056 when the Planck TT power spectrum is included in the combination. Finally, combining Planck with BICEP2/Keck 2015 data yields an upper limit of r < 0.044.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical investigation of gas-filled multipass cells in the enhanced dispersion regime for clean spectral broadening and pulse compression

We show via numerical simulations that the regime of enhanced frequency chirp can be achieved in gas-filled multipass cells. Our results demonstrate that there exists a region of pulse and cell parameters for which a broad and flat spectrum with a smooth parabolic-like phase can be generated. This spectrum is compatible with clean ultrashort pulses, whose secondary structures are always below the 0.5% of its peak intensity such that the energy ratio (the energy contained within the main peak of the pulse) is above 98%. This regime makes multipass cell post-compression one of the most versatile schemes to sculpt a clean intense ultrashort optical pulse.

Segundo Staels, V. W. (ORCID:0000000200056157)↗

Near Optimality of Matched Filter Detection for Cyclic Prefix Direct Sequence Spread Spectrum

Abstract—Cyclic Prefix Direct Sequence Spread Spectrum -DSSS) has been presented as a potential solution for ultrareliable low latency communications (URLLC) and massive machine type communication (mMTC), where the CP-DSSS waveform would operate as a secondary network at the same frequencies as the primary network but at much lower SNR. In this paper, we show that when operating in the low SNR regime, CP-DSSS achieves near optimum performance when using a matched filter (MF) detector at the receiver. Time reversal (TR) precoding at the transmitter is also analyzed. These results also carry forward into multi-antenna scenarios where array gain is preserved. With nearly optimal performance of MF detection, CP-DSSS can be implemented with simple device transceiver structures, reducing per-unit cost for massively deployed networks.

5G and Beyond Communications↗

First constraints on causal sources of primordial gravitational waves from BICEP/Keck, SPTpol, SPT-3G, Planck and WMAP $B$-mode data

Non-inflationary sources of gravitational waves in the early Universe generically predict causality-limited tensor power spectra at low frequencies. We report the first-ever constraints on such sources based on cosmic microwave background (CMB) $B$-mode polarization measurements. Using data from BICEP/Keck, SPTpol, SPT-3G, Planck, and WMAP, we constrain the amplitude of an early causal tensor (ECT) power spectrum parameterized by $r_{ect}$, the ratio of causal tensor power to total scalar power at $k~=~0.01$ Mpc$^{-1}$, and obtain a 95% CL upper limit of $r_{ect}<$ 0.0077. Since $r_{ect}$ can easily be related to the parameters of a given theory, our bound robustly constrains a broad class of well-motivated gravitational wave sources in the early universe, including first-order cosmological phase transitions, enhanced small-scale density perturbations, and various topological defects. Finally, we translate our limit into a bound on the present-day energy density in gravitational waves at ultra-low frequencies otherwise inaccessible to traditional gravitational wave detection strategies, including pulsar timing arrays, interferometers, and resonant cavities.

Zebrowski, Jessica A. [Fermilab; Chicago U., KICP]↗

Computationally Guided Investigation of the Optical Spectra of Pure β-UO 3

Single-phase β-UO 3 is synthesized by flash heating UO 2 (NO 3 )·6H 2 O in air to 450 °C and annealing for 60 h under the same conditions. For the first time, we report the Raman spectra of pure β-UO 3 . To facilitate the assignment of Raman and infrared vibrational modes, we use density functional theory with density functional perturbation theory. By employing a novel analysis scheme that includes the mode frequencies as well as a quantitative analysis of the mode eigenvectors, we assign the observed spectral features to individual chemical modes. In particular, the density functional theory optimized structure, observed Raman spectrum, and eigenvector analysis suggest the presence of four crystallographically distinct uranyl ions, one more than has previously been suggested.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vibrational Properties of a Naturally Occurring Semiconducting van der Waals Heterostructure

We present vibrational properties of Franckeite, which is a naturally occurring van der Waals heterostructure consisting of two different semiconducting layers. Franckeite is a complex layered crystal composed of alternating SnS 2 -like pseudohexagonal and PbS-like pseudotetragonal layers stacked on top of each other, providing a unique platform to study vibrational properties and thermal transport across layers with mass density and phonon mismatches. Using micro-Raman spectroscopy and first-principles Raman simulations, we found that the PbS-like pseudotetragonal structure is mostly composed of Pb 3 SbS 4 . We also discovered several low-frequency Raman modes that originate from the intralayer vibrations of the pseudotetragonal layer. Using density functional theory, we determined all vibrational patterns of Franckeite, whose signatures are observed in the Raman spectrum. By studying temperature-dependent Raman spectroscopy (300–500 K), we have found different temperature coefficients for both pseudotetragonal and pseudohexagonal layers. Here, we believe that our study will help understand the vibration modes of its complex heterostructure and the thermal properties at the nanoscale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron cyclotron emission measurements and modeling in optically semi-transparent plasma on the HSX stellarator

On the Helically Symmetric Experiment (HSX), electron cyclotron emission (ECE) at the second harmonic of the electron gyrofrequency is measured with a 16-channel heterodyne receiver. An ECE radiometer diagnostic has been calibrated with a broadband frequency source, allowing independent measurements of the electron temperature. The antenna pattern has a significant impact on the measurements, and modeling its effect is necessary to produce an ECE radiation temperature spectrum. Measurements, calibration results, and modeling of the ECE data are presented in this paper. At a relatively high plasma density, HSX plasmas are thermal, and the radiation temperature measured by the radiometer is in good agreement with the electron temperature measured by a Thomson scattering diagnostic. At a relatively low plasma density, the deviation from a Maxwellian distribution is large, and asymmetry in the radiation temperature profile is measured. These measurements are supported by single-pass and multi-pass ray tracing calculations of the electron cyclotron emission using the TRAVIS ray tracing code. Thermal and nonthermal electron populations exist in HSX, and the effect of these populations on the asymmetry in the measured emission is presented.

Cyclotron radiation↗

Electron Affinity and Electronic Structure of Hexafluoroacetone (HFA) Revealed by Photodetaching the [HFA] •– Radical Anion

A great deal of effort has been focused on developing a metal-free catalytic system for epoxidation of unreactive alkenes. Fluoroketones are thought as remarkably promising catalysts for epoxidation reactions. The combination of fluorinated alcohols and catalytic amounts of hexafluoroacetone (HFA) gives a versatile and effective medium for epoxidation of various olefins with hydrogen peroxide. However, the fundamental physicochemical properties of HFA remained largely unclear, although they were very important to understand the related interactions. Here, in this study, we performed a joint study on the electron affinity and electronic structure of HFA employing negative ion photoelectron (NIPE) spectroscopy and quantum chemistry calculations. Two distinct bands with complicated vibrational progressions were observed in the 193 nm NIPE spectrum. The adiabatic/vertical detachment energies (ADE/VDE) were derived to be 1.42/2.06 and 4.43/4.86 eV for the ground singlet state and excited triplet state, respectively. Using the optimized geometries and vibrational frequencies of the anion and the neutral, the Franck–Condon factors were calculated for electron detachments to produce HFA in its lowest singlet and triplet states. Good agreements are obtained hereby for both bands between the experimental and calculated NIPE spectra, when taking into account combination vibrational excitations, unequivocally revealing that HFA possesses a singlet ground state with a giant singlet–triplet energy difference (ΔE ST ). The electron affinity (EA) and ΔE ST of HFA were therefore determined to be EA = 1.42 ± 0.02 eV and ΔE ST = −3.01 eV.

Wang, Lei↗

Shivalik Plasma Device-I, a glow discharge device to study the collective dynamics of dusty plasma

Using a uniquely configured glow discharge-based Shivalik Plasma Device-I, we demonstrate a variety of collective phenomena in dusty plasma away from the glow discharge region. The cylindrical glass device produces plasma using parallel disc-shaped electrodes with a smaller anode size than the cathode. The dust microparticles are initially sprinkled over the grounded cathode. These particles acquire a significant negative charge upon plasma formation, resulting in their levitation due to the balance between the Coulomb force and gravity. The new device supports the levitation of a big-sized (10 × 8 × 5 cm 3 ) three-dimensional dust cloud over the glass surface. It contrasts the dusty plasma formations in-between electrodes reported earlier. As the discharge voltage varies from high to low, the dust cloud travels from over the glass surface to between the electrodes. A complex interplay of dust void over the cathode, a sharp density gradient, and gravity lead to self-excitation of collective dust phenomena. It includes dust density waves (phase velocity, v ph ~4 cm/s), dust cloud oscillation (frequency, f = 5 Hz), sheared flow (flow velocity, v f ~ 1 cm/s), and multiple-sized dust vortices. These dust vortices provided an excellent platform for studying turbulent mixing phenomena. The power spectrum analysis agreed with two-dimensional Kolmogorov power-law scaling. This is an ideal dusty plasma apparatus where we can create or move the dust cloud to a location of choice from the glass surface to in-between the electrodes and excite one among many collective dust dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Missing-Data Nonparametric Coherency Estimation

Chave recently proposed an estimator for multitaper spectral density where the time series contains missing values. In this article we generalize this technique to a multitaper estimator of coherence and phase and show that one can also obtain bootstrapped confidence intervals. Additionally, we give two examples. The first is a toy example in which the true coherence is known. In the second example we show that the multitaper missing-data coherence estimator computed on real data with a single gap comprising 11% of the data outperforms the Daniell-smoothed coherence estimator where there are no gaps. The case where the two time series have different missing indices is also discussed.

42 ENGINEERING↗

Augmented Human Analysis (AHA)

Radio frequency (RF) signal monitoring generally emphasizes intentionally generated signals, such as WiFi, Bluetooth, or cellular transmissions. However, electronic devices also produce unintended radiated emissions (UREs), which could also be useful in RF spectrum analysis. In either case, deriving intelligence from RF signals is typically a human-intensive process requiring significant domain knowledge. In the Augmented Human Analysis (AHA) project, we investigate the utility of dimensionally aligned signal projection (DASP) and machine learning (ML) algorithms for accelerating RF analysis workflows. We find that while DASP algorithms can indeed highlight signal characteristics relevant for classification tasks, the choice of algorithmic hyperparameters greatly affects performance. To address this challenge, we evaluate the quality of DASP outputs using the silhouette score, which measures how well data points cluster; high silhouette scores indicate good clustering, and thus good hyperparameter values. This approach is critical for machine learning pipelines as the DASP parameters cannot be directly optimized during model training. By identifying good DASP parameters, and thus good DASP outputs, as a preprocessing step, we can decrease the amount of effort required for downstream ML model training. We demonstrate our workflow using a dataset of UREs from common household devices, showing that even without the aid of ML, proper selection of DASP parameters enables clustering by device type.

42 ENGINEERING↗

Universally high transcript error rates in bacteria

Errors can occur at any level during the replication and transcription of genetic information. Genetic mutations derived mainly from replication errors have been extensively studied. However, fundamental details of transcript errors, such as their rate, molecular spectrum, and functional effects, remain largely unknown. To globally identify transcript errors, we applied an adapted rolling-circle sequencing approach to Escherichia coli, Bacillus subtilis, Agrobacterium tumefaciens, and Mesoplasma florum, revealing transcript-error rates 3 to 4 orders of magnitude higher than the corresponding genetic mutation rates. The majority of detected errors would result in amino-acid changes, if translated. With errors identified from 9929 loci, the molecular spectrum and distribution of errors were uncovered in great detail. A G→A substitution bias was observed in M. florum, which apparently has an error-prone RNA polymerase. Surprisingly, an increased frequency of nonsense errors towards the 3' end of mRNAs was observed, suggesting a Nonsense-Mediated Decay-like quality-control mechanism in prokaryotes.

59 BASIC BIOLOGICAL SCIENCES↗