Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Evaluating the purity of a {sup 57}Co flood source by PET

Purpose: Flood sources of {sup 57}Co are commonly used for quality control of gamma cameras. Flood uniformity may be affected by the contaminants {sup 56}Co and {sup 58}Co, which emit higher energy photons. Although vendors specify a maximum combined {sup 56}Co and {sup 58}Co activity, a convenient test for flood source purity that is feasible in a clinical environment would be desirable. Methods: Both {sup 56}Co and {sup 58}Co emit positrons with branching 19.6% and 14.9%, respectively. As is known from {sup 90}Y imaging, a positron emission tomography (PET) scanner is capable of quantitatively imaging very weak positron emission in a high single-photon background. To evaluate this approach, two {sup 57}Co flood sources were scanned with a clinical PET/CT multiple times over a period of months. The {sup 56}Co and {sup 58}Co activity was clearly visible in the reconstructed PET images. Total impurity activity was quantified from the PET images after background subtraction of prompt gamma coincidences. Results: Time-of-flight PET reconstruction was highly beneficial for accurate image quantification. Repeated measurements of the positron-emitting impurities showed excellent agreement with an exponential decay model. For both flood sources studied, the fit parameters indicated a zero intercept and a decay half-life consistent with a mixture of {sup 56}Co and {sup 58}Co. The total impurity activity at the reference date was estimated to be 0.06% and 0.07% for the two sources, which was consistent with the vendor’s specification of <0.12%. Conclusions: The robustness of the repeated measurements and a thorough analysis of the detector corrections and physics suggest that the accuracy is acceptable and that the technique is feasible. Further work is needed to validate the accuracy of this technique with a calibrated high resolution gamma spectrometer as a gold standard, which was not available for this study, and for other PET detector models.

07 ISOTOPE AND RADIATION SOURCES↗

A Virtual Frame System for Stereotactic Radiosurgery Planning

Purpose: We describe a computerized (or virtual) model of a stereotactic head frame to enable planning prior to the day of radiosurgery. The location of the virtual frame acts as a guide to frame placement on the day of the procedure. Methods and Materials: The software consists of a triangular mesh representation of the essential frame hardware that can be overlaid with any MR scan of the patient and manipulated in three dimensions. The software calculates regions of the head that will actually be accessible for treatment, subject to the geometric constraints of the Leksell Gamma Knife hardware. DICOM-compliant MR images with virtual fiducial markers overlaid onto the image can then be generated for recognition by the treatment planning system. Results: Retrospective evaluation of the software on 24 previously treated patients shows a mean deviation of the position of the virtual frame from the actual frame position of 1.6 {+-} 1.3 mm. Initial clinical use on five patients indicates an average discrepancy of the virtual frame location and the actual frame location of <1 mm. MR images with virtual fiducial markers can be imported into radiosurgical treatment planning software and used to generate an initial treatment plan. Conclusions: The virtual frame provides a tool for prospective determination of lesion accessibility, optimization of the frame placement, and treatment planning before the day of the procedure. This promises to shorten overall treatment times, improve patient comfort, and reduce the need for repeat treatments due to suboptimally placed frames.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Dose Reconstruction for Scanned Proton Therapy Using Liver 4DCT-MRI

Purpose: Four-dimensional computed tomography-magnetic resonance imaging (4DCT-MRI) is an image-processing technique for simulating many 4DCT data sets from a static reference CT and motions extracted from 4DMRI studies performed using either volunteers or patients. In this work, different motion extraction approaches were tested using 6 liver cases, and a detailed comparison between 4DCT-MRI and 4DCT was performed. Methods and Materials: 4DCT-MRI has been generated using 2 approaches. The first approach used motion extracted from 4DMRI as being “most similar” to that of 4DCT from the same patient (subject-specific), and the second approach used the most similar motion obtained from a motion library derived from 4DMRI liver studies of 13 healthy volunteers (population-based). The resulting 4DCT-MRI and 4DCTs were compared using scanned proton 4D dose calculations (4DDC). Results: Dosimetric analysis showed that 93% ± 8% of points inside the clinical target volume (CTV) agreed between 4DCT and subject-specific 4DCT-MRI (gamma analysis: 3%/3 mm). The population-based approach however showed lower dosimetric agreement with only 79% ± 14% points in the CTV reaching the 3%/3 mm criteria. Conclusions: 4D CT-MRI extends the capabilities of motion modeling for dose calculations by accounting for realistic and variable motion patterns, which can be directly employed in clinical research studies. We have found that the subject-specific liver modeling appears more accurate than the population-based approach. The former is particularly interesting for clinical applications, such as improved target delineation and 4D dose reconstruction for patient-specific QA to allow for inter- and/or intra-fractional plan corrections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Invisible Higgs decays from Higgs-graviscalar mixing

We recompute the invisible Higgs decay width arising from Higgs-graviscalar mixing in the Arkani-Hamed, Dimopoulos, Dvali model, comparing the original derivation in the nondiagonal mass basis to that in a diagonal mass basis. The results obtained are identical (and differ by a factor of 2 from the original calculation) but the diagonal-basis derivation is pedagogically useful for clarifying the physics of the invisible width from mixing. We emphasize that both derivations make it clear that a direct scan in energy for a process such as WW{yields}WW mediated by Higgs plus graviscalar intermediate resonances would follow a single Breit-Wigner form with total width given by {gamma}{sup tot}={gamma}{sub h}{sup SM}+{gamma}{sub invisible}. We also compute the additional contributions to the invisible width due to direct Higgs to graviscalar-pair decays. We find that the invisible width due to the latter is relatively small, unless the Higgs mass is comparable to or larger than the effective extra-dimensional Planck mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity and variability of Presage dosimeter formulations in sheet form with application to SBRT and SRS QA

Purpose: To measure sensitivity and stability of the Presage dosimeter in sheet form for various chemical concentrations over a range of clinical photon energies and examine its use for stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) QA. Methods: Presage polymer dosimeters were formulated to investigate and optimize their sensitivity and stability. The dosimeter is composed of clear polyurethane base, leucomalachite green (LMG) reporting dye, and bromoform radical initiator in 0.9–1.0 mm thick sheets. The chemicals are mixed together for 2 min, cast in an aluminum mold, and left to cure at 60 psi for a minimum of two days. Dosimeter response was characterized at energies Co-60, 6 MV, 10 MV flattening-filter free, 15 MV, 50 kVp (mean 19.2 keV), and Ir-192. The dosimeters were scanned by a Microtek Scanmaker i800 at 300 dpi, 2{sup 16} bit depth per color channel. Red component images were analyzed with ImageJ and RIT. SBRT QA was done with gamma analysis tolerances of 2% and 2 mm DTA. Results: The sensitivity of the Presage dosimeter increased with increasing concentration of bromoform. Addition of tin catalyst decreased curing time and had negligible effect on sensitivity. LMG concentration should be at least as high as the bromoform, with ideal concentration being 2% wt. Gamma Knife SRS QA measurements of relative output and profile widths were within 2% of manufacturer’s values validated at commissioning, except the 4 mm collimator relative output which was within 3%. The gamma pass rate of Presage with SBRT was 73.7%, compared to 93.1% for EBT2 Gafchromic film. Conclusions: The Presage dosimeter in sheet form was capable of detecting radiation over all tested photon energies and chemical concentrations. The best sensitivity and photostability of the dosimeter were achieved with 2.5% wt. LMG and 8.2% wt. bromoform. Scanner used should not emit any UV radiation as it will expose the dosimeter, as with the Epson 10000 XL scanner. Presage dosimeter in this form was sensitive enough for use in SRS and SBRT QA. The lower gamma pass rate for Presage compared to Gafchromic film can be attributed to the simple equipment used in the fabrication process, which limited the dosimeter’s sensitivity uniformity by agglomeration of air bubbles in the material, nonuniform concentration of chemicals throughout the material, and thickness variations. This demands improvements in mixing tools and molds.

60 APPLIED LIFE SCIENCES↗

Initial OSSE Sky Survey Observation: Deep Survey in the Virgo Region

The OSSE Virgo survey covered about 1% of the sky, using eight weeks of observing time on the Compton Gamma Ray Observatory, and was performed in conjunction with the EGRET and COMPTEL instruments on CGRO. A fundamental aspect of the survey was the development of data reduction techniques for the scanning data from the OSSE detectors. A direct algebraic approach for spatially deconvolving the data was developed. For the survey work, no background observations isolated from the survey region were acquired, unlike normal discrete source observations. The survey, reduction method covers the mapped region with a grid of pixels, and estimates the flux from each pixel by least-squares agreement with the data, assuming positivity constraints. This technique has led to the detection of compact sources at hard X-ray energies within the Virgo region, and the OSSE survey studies have been extended to the south galactic pole and north Ecliptic pole, with similar analysis techniques.

Cameron, Robert↗

Radiolytic Gas Production from Aluminum Coupons (Alloy 1100 and 6061) in Helium Environments—Assessing the Extended Storage of Aluminum Clad Spent Nuclear Fuel

Corrosion of aluminium alloy clad nuclear fuel, during reactor operation and under subsequent wet storage conditions, promotes the formation of aluminium hydroxide and oxyhydroxide layers. These hydrated mineral phases and the chemisorbed and physisorbed waters on their surfaces are susceptible to radiation-induced processes that yield molecular hydrogen gas (H 2 ), which has the potential to complicate the long-term storage and disposal of aluminium clad nuclear fuel through flammable and explosive gas mixture formation, alloy embrittlement, and pressurization. Here, we present a systematic study of the radiolytic formation of H 2 from aluminium alloy 1100 (AA1100) and 6061 (AA6061) coupons in “dry” (~0% relative humidity) and “wet” (50% relative humidity) helium environments. Cobalt-60 gamma irradiation of both aluminium alloy types promoted the formation of H 2 , which increased linearly up to ~2 MGy, and afforded G-values of 1.1 ± 0.1 and 2.9 ± 0.1 for “dry” and “wet” AA1100, and 2.7 ± 0.1 and 1.7 ± 0.1 for “dry” and “wet” AA6061. The negative correlation of H 2 production with relative humidity for AA6061 is in stark contrast to AA1100 and is attributed to differences in the extent of corrosion and varying amounts of adsorbed water in the two alloys, as characterized using optical profilometry, scanning electron microscopy, Raman spectroscopy, and X-ray diffraction techniques.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Technical Note: Experimental carbon ion range verification in inhomogeneous phantoms using prompt gammas

Purpose: The purpose of this study was to experimentally assess the possibility to monitor carbon ion range variations—due to tumor shift and/or elongation or shrinking—using prompt-gamma (PG) emission with inhomogeneous phantoms. Such a study is related to the development of PG monitoring techniques to be used in a carbon ion therapy context. Methods: A 95 MeV/u carbon ion beam was used to irradiate phantoms with a variable density along the ion path to mimic the presence of bone and lung in homogeneous humanlike tissue. PG profiles were obtained after a longitudinal scan of the phantoms. A setup comprising a narrow single-slit collimator and two detectors placed at 90° with respect to the beam axis was used. The time of flight technique was applied to allow the selection between PG and background events. Results: Using the positions at 50% entrance and 50% falloff of the PG profiles, a quantity called prompt-gamma profile length (PGPL) is defined. It is possible to observe shifts in the PGPL when there are absolute ion range shifts as small as 1–2 mm. Quantitatively, for an ion range shift of −1.33 ± 0.46 mm (insertion of a Teflon slab), a PGPL difference of −1.93 ± 0.58 mm and −1.84 ± 1.27 mm is obtained using a BaF{sub 2} and a NaI(Tl) detector, respectively. In turn, when an ion range shift of 4.59 ± 0.42 mm (insertion of a lung-equivalent material slab) is considered, the difference is of 4.10 ± 0.54 and 4.39 ± 0.80 mm for the same detectors. Conclusions: Herein, experimental evidence of the usefulness of employing PG to monitor carbon ion range using inhomogeneous phantoms is presented. Considering the homogeneous phantom as reference, the results show that the information provided by the PG emission allows for detecting ion range shifts as small as 1–2 mm. When considering the expected PG emission from an energy slice in a carbon ion therapy scenario, the experimental setup would allow to retrieve the same PGPL as the high statistics of the full experimental dataset in 58% of the times. However, this success rate increases to 93% when using a better optimized setup by means of Monte Carlo simulations.

60 APPLIED LIFE SCIENCES↗

Crystallization kinetics and thermal properties of 20Li{sub 2}O-80TeO{sub 2} glass

In this work, X-ray diffraction, Raman spectroscopy and differential scanning calorimetry techniques were used to understand the crystallization process on 20Li{sub 2}O-80TeO{sub 2} glass. X-ray diffraction results reveal the presence of three distinct alpha {gamma}-TeO{sub 2}, {alpha}-TeO{sub 2} and {alpha}-Li{sub 2}Te{sub 2}O{sub 5} crystalline phases in the glass matrix. The Raman spectroscopy band structure of this glass is similar to the one observed in glassy TeO{sub 2}. Raman results clearly reveal the metastable character of the {gamma}-TeO{sub 2} phase in the 20Li{sub 2}O-80TeO{sub 2} glass, whose associated vibration modes disappear completely at temperatures higher than 315 deg. C. On the other hand, the Raman modes associated to {alpha}-TeO{sub 2} and {alpha}-Li{sub 2}Te{sub 2}O{sub 5} phases persists up to temperatures close to the final stages of the crystallization in the studied glass (around 420 deg. C). From DSC measurements, the activation energies 296 {+-} 3 and 298 {+-} 1 kJ mol{sup -1} were associated to {gamma}-TeO{sub 2} and {alpha}-TeO{sub 2} phases crystallization, indicating that these phases crystallizes at temperatures very close in the studied glass.

36 MATERIALS SCIENCE↗

Microstructure Evolution of Alloy 625 Foil and Sheet During Creep at 750 o C

Creep-rupture tests in air of foils and sheets of the nickel-based superalloy 625 at 750oC and 100 MPa have been conducted, and indicate the additional processing required to achieve foil form reduces creep life compared to thicker-section wrought product forms. Both scanning and transmission electron microscopy were employed to examine as-processed and creep-tested specimens to correlate observed microstructures and creep behavior. Prior to creep testing, the morphology consists of gamma phase with M6C precipitates. This morphology changes during creep to one consisting of orthorhombic delta phase extending across gamma grains, and grain boundaries dominated by the presence of rhombohedral mu phase, delta phase, and a diamond-cubic eta phase. Additionally, temperature ranges of equilibrium phase field stability were calculated using JMatPro. The phases predicted and their compositions generally agree with those observed within the superalloy after creep testing.

analytical electron microscopy↗

PIE on Five Irradiated AGR-1 Compacts

Post-irradiation examination (PIE) is in progress on coated particle fuel compacts from the first Advanced Gas Reactor irradiation experiment (AGR-1). PIE has been completed on five compacts at the Oak Ridge National Laboratory (ORNL). Three compacts (Compacts 6-1-1, 4-4-2, and 5-2-3) were examined in the as-irradiated condition and two compacts (Compacts 6-4-3 and 3-3-2) were subjected to safety testing at 1600°C, followed by post-safety testing examination similar to the PIE performed on the as-irradiated compacts. All compacts were subjected to a standard set of analyses that included the following: (1) detection of exposed fission products by Deconsolidation-Leach-Burn-Leach (DLBL), (2) measurement of gamma-emitting fission product inventory using the Irradiated Microsphere Gamma Analyzer (IMGA), and (3) microstructural examination by x-ray tomography and materialography. The equipment and methods used are reported in detail in ORNL/TM-2012/233, AGR-1 Irradiated Compact 6-1-1 PIE Report, and have been summarized in the next section of this report. This report also provides a brief summary of the results of the completed PIE. Preliminary trends are discussed in this report, but final conclusions will require the support of additional data and further analysis. A separate report is being generated for each AGR-1 compact after PIE is complete that describes in detail the examinations performed and fully documents the data obtained. A final AGR-1 PIE summary report will compile all available data and provide a more comprehensive analysis of the AGR-1 fuel performance. In general, it was observed that the tristructural isotropic (TRISO) coated particles remained intact during irradiation and subsequent safety testing to 1600°C. No significant gaseous 85 Kr release was detected during the irradiation or high temperature safety testing, which would be indicative of simultaneous failure of all three outer layers of the TRISO coating. Only three particles with defective SiC layers were detected in the five compacts included in this summary. These particles were detected because they released a significant fraction of their cesium inventory, which was generally well retained. Two particles from Compact 5-2-3 released cesium during irradiation and one particle from Compact 3-3-2 released cesium during safety testing. However, it is evident that some fission products were released through intact SiC during irradiation. Most of these fission products were trapped in the compact matrix, where they could be analyzed by PIE. In terms of fractional release, the main fission products detected outside intact SiC were silver, palladium, and europium. The main impact of irradiation on the microstructure of the TRISO-coating layers was densification and shrinkage of the buffer layer, which often led to buffer fracture and subsequent enhanced swelling of the kernel. Some inner pyrocarbon (IPyC) layers were cracked by the radiation-induced changes in the buffer layer, and on rare occasion these cracks propagated into the SiC. In the two particles that released cesium during irradiation, these SiC cracks penetrated through the entire layer. The particle from Compact 3-3-2 that released cesium was not directly related to irradiation damage. Its SiC layer was determined to be porous as a result of a fabrication defect that occurs when a particle is over-fluidized in the coater, causing it to pick up carbon soot on the surface of the IPyC prior to SiC deposition. This porous SiC layer remained sufficiently intact during irradiation to retain cesium, but finally cracked during high temperature testing. Analysis of fission products remaining in the coated particles showed that the retention of silver varied dramatically from particle-to-particle within each compact. Examination with the IMGA determined that some particles contained a level of 110m Ag equivalent to that calculated to have been generated over the three-year irradiation period, while other particles contained too little to be detected by the gamma analysis. The mechanism for silver release is still being investigated. Attempts to correlate the varied release behavior to obvious radiation-induced changes in the coating layers have not been successful. Scanning electron microscopy (SEM) has provided some evidence that particles with higher silver release also show greater penetration of palladium silicide into the SiC layer, and this should be studied further.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultra-high molecular weight silphenylene-siloxane polymers

Silphenylene-siloxane copolymers with molecular weights above one million were prepared using a two stage polymerization technique. The technique was successfully scaled up to produce 50 grams of this high polymer in a single run. The reactive monomer approach was also investigated using the following aminosilanes: bis(dimethylamino)dimethylsilane, N,N-bis(pyrrolidinyl)dimethylsilane and N,N-bis(gamma-butyrolactam)dimethylsilane). Thermal analyses were performed in both air and nitrogen. The experimental polymers decomposed at 540 to 562 C, as opposed to 408 to 426 C for commercial silicones. Differential scanning calorimetry showed a glass transition (Tg) at -50 to -55 C for the silphenylene-siloxane copolymer while the commercial silicones had Tg's at -96 to -112 C.

Patterson, W. J.↗

Solvent-drop Assisted Mechanochemical Synthesis of the Black and Green Polymorphs of the Tetrathiafulvalene-chloranil Charge Transfer Salt

This work describes the synthesis of the green and black polymorphic forms of the tetrathiafulvalene-chloranil (TTF-CA) charge transfer salt as pure phases, by solvent-assisted mechanochemistry. Both materials were characterized using laboratory and high-resolution X-ray powder diffraction (XRPD), elemental analysis and scanning electron microscopy (SEM). The high-resolution XRPD pattern of the TTF-CA black polymorph was indexed with a triclinic lattice a = 10.756(5) {angstrom}, b = 11.057(4) {angstrom}, c = 6.614(2) {angstrom}, {alpha} = 101.36(2){sup o}, {beta} = 93.69(3){sup o}, {gamma} = 89.37(3){sup o}, V = 769.6(5) {angstrom}{sup 3}. The chemical stability of these phases upon heating was investigated using thermogravimetric analysis (TGA), elemental analysis and X-ray powder diffraction (XRPD), indicating that both polymorphs undergo chemical decomposition, and ruling out the transition to an air-stable high temperature polymorph.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-626: Accuracy of Dose Calculation Algorithms in MultiPlan Treatment Planning System in Presence of Heterogeneities

Purpose: Advanced stereotactic radiotherapy (SRT) treatments require accurate dose calculation for treatment planning especially for treatment sites involving heterogeneous patient anatomy. The purpose of this study was to evaluate the accuracy of dose calculation algorithms, Raytracing and Monte Carlo (MC), implemented in the MultiPlan treatment planning system (TPS) in presence of heterogeneities. Methods: First, the LINAC of a CyberKnife radiotherapy facility was modeled with the PENELOPE MC code. A protocol for the measurement of dose distributions with EBT3 films was established and validated thanks to comparison between experimental dose distributions and calculated dose distributions obtained with MultiPlan Raytracing and MC algorithms as well as with the PENELOPE MC model for treatments planned with the homogenous Easycube phantom. Finally, bones and lungs inserts were used to set up a heterogeneous Easycube phantom. Treatment plans with the 10, 7.5 or the 5 mm field sizes were generated in Multiplan TPS with different tumor localizations (in the lung and at the lung/bone/soft tissue interface). Experimental dose distributions were compared to the PENELOPE MC and Multiplan calculations using the gamma index method. Results: Regarding the experiment in the homogenous phantom, 100% of the points passed for the 3%/3mm tolerance criteria. These criteria include the global error of the method (CT-scan resolution, EBT3 dosimetry, LINAC positionning …), and were used afterwards to estimate the accuracy of the MultiPlan algorithms in heterogeneous media. Comparison of the dose distributions obtained in the heterogeneous phantom is in progress. Conclusion: This work has led to the development of numerical and experimental dosimetric tools for small beam dosimetry. Raytracing and MC algorithms implemented in MultiPlan TPS were evaluated in heterogeneous media.

60 APPLIED LIFE SCIENCES↗

Addendum to the Survey Report for the Characterization of the Five Tanks Located Near the Old Salvage Yard at the Y-12 National Security Complex, Oak Ridge, Tennessee

The purpose if this addendum is to provide clarifying information related to two issues delaying disposal of Tank 2, located west of the Old Salvage Yard at the Y-12 National Security Complex. The two issues are as follows: 1. The discovery and documentation of apparent elevated results on the external rusty surface of Tank 2; 2. The proper interpretation and use of scan data. Oak Ridge Associated Universities (ORAU) health physics technicians (HPTs), operating under the Oak Ridge Institute for Science and Education contract, performed 100% scans over accessible interior and exterior surfaces of the five tanks located near the Old Salvage Yard, per the stakeholder-approved project-specific plan. Three types of measurements were collected, including gamma radiation measurements using a Ludlum model 44-10 gamma scintillation detector connected to a Ludlum model 2221 ratemeter/scaler; alpha radiation measurements using a Ludlum model 43-68 gas proportional detector connected to a 2221 ratemeter/scaler; and alpha-plus-beta radiation measurements also using a Ludlum model 43-68 connected to a 2221 ratermeter/scaler. The alpha-plus-beta characterization data is the primary subject of this addendum.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cross-linking of polytetrafluoroethylene during room-temperature irradiation

Exposure of polytetrafluoroethylene (PTFE) to {alpha}-radiation was investigated to detennine the physical and chemical effects, as well as to compare and contrast the damage mechanisms with other radiation types ({beta}, {gamma}, or thermal neutron). A number of techniques were used to investigate the chemical and physical changes in PTFE after exposure to {alpha}-radiation. These techniques include: Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), and fluorescence spectroscopy. Similar to other radiation types at low doses, the primary damage mechanism for the exposure of PTFE to {alpha}-radiation appears to be chain scission. Increased doses result in a change-over of the damage mechanism to cross-linking. This result is not observed for any radiation type other than {alpha} when irradiation is performed at room temperature. Finally, at high doses, PTFE undergoes mass-loss (via smallfluorocarbon species evolution) and defluorination. The amount and type of damage versus sample depth was also investigated. Other types of radiation yield damage at depths on the order of mm to cm into PTFE due to low linear energy transfer (LET) and the correspondingly large penetration depths. By contrast, the {alpha}-radiation employed in this study was shown to only induce damage to a depth of approximately 26 {mu}m, except at very high doses.

36 MATERIALS SCIENCE↗

SU-E-CAMPUS-T-06: Initial Experience of Patient-Specific QA Using a Pencil Beam Scanning Proton Therapy System

Purpose: To illustrate patient QA results for the first 10 patients treated at Scripps Proton Center by comparing point dose measurement using an ion chamber and in-house developed secondary MU program, and the measurement of 2D dose distribution using an ion chamber array. Methods: At the time of writing, 10 patient plans were approved for treatment using Varian ProBeam pencil beam scanning system and Eclipse treatment planning software. We used the IBA CC04 0.04 cm3 ion chamber and PTW Unidos E electrometer for point dose measurement in a small water tank (Sun Nuclear 1D scanner). We developed independent MU check software based on measured pencil beam dose profiles for various energies. We used PTW Octavius 729 XDR array to evaluate 2D planar dose distribution. The 3D gamma at 3%/3 mm local dose was used to compare a 3D calculated dose plan with a 2D measured dose distribution using PTW Verisoft software. All fields were exported to a verification phantom plan and delivered at 0 degrees for simplicity. Results: Comparisons between the CC04 ion chamber measurement and calculated dose agree well within 1%. The PTW Octavius 729 XDR array exhibited some dose rate dependence in high dose rate pencil beam delivery. Nevertheless, the results, used as a relative measurement, passed the gamma criteria of 3%/3mm for greater than 90% of area in all patient fields. Visual inspection showed good agreement between ion chamber dose profile and the calculated plan. The in-house secondary check for MU agreed very well with the plan dose and measurement. The results will be updated with more patients treated. Conclusion: The initial patient specific QA results are encouraging for a new pencil beam scanning only proton therapy system.

60 APPLIED LIFE SCIENCES↗