Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gate selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

MO-PIS-Exhibit Hall-01: Imaging: CT Dose Optimization Technologies I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Dose Optimization Capabilities of GE Computed Tomography Scanners Presentation Time: 11:15 – 11:45 AM GE Healthcare is dedicated to the delivery of high quality clinical images through the development of technologies, which optimize the application of ionizing radiation. In computed tomography, dose management solutions fall into four categories: employs projection data and statistical modeling to decrease noise in the reconstructed image - creating an opportunity for mA reduction in the acquisition of diagnostic images. Veo represents true Model Based Iterative Reconstruction (MBiR). Using high-level algorithms in tandem with advanced computing power, Veo enables lower pixel noise standard deviation and improved spatial resolution within a single image. Advanced Adaptive Image Filters allow for maintenance of spatial resolution while reducing image noise. Examples of adaptive image space filters include Neuro 3-D filters and Cardiac Noise Reduction Filters. AutomA adjusts mA along the z-axis and is the CT equivalent of auto exposure control in conventional x-ray systems. Dynamic Z-axis Tracking offers an additional opportunity for dose reduction in helical acquisitions while SmartTrack Z-axis Tracking serves to ensure beam, collimator and detector alignment during tube rotation. SmartmA provides angular mA modulation. ECG Helical Modulation reduces mA during the systolic phase of the heart cycle. SmartBeam optimization uses bowtie beam-shaping hardware and software to filter off-axis x-rays - minimizing dose and reducing x-ray scatter. The DICOM Radiation Dose Structured Report (RDSR) generates a dose report at the conclusion of every examination. Dose Check preemptively notifies CT operators when scan parameters exceed user-defined dose thresholds. DoseWatch is an information technology application providing vendor-agnostic dose tracking and analysis for CT (and all other diagnostic x-ray modalities) SnapShot Pulse improves coronary CTA dose management. VolumeShuttle uses two acquisitions to increase coverage, decrease dose, and conserve on contrast administration. Color-Coding for Kids applies the Broselow-Luten Pediatric System to facilitate pediatric emergency care and reduce medical errors. FeatherLight achieves dose optimization through pediatric procedure-based protocols. Adventure Series scanners provide a child-friendly imaging environment promoting patient cooperation with resultant reduction in retakes and patient motion. Philips CT Dose Optimization Tools and Advanced Reconstruction Presentation Time: 11:45 ‘ 12:15 PM The first part of the talk will cover “Dose Reduction and Dose Optimization Technologies” present in Philips CT Scanners. The main Technologies to be presented include: DoseRight and tube current modulation (DoseRight, Z-DOM, 3D-DOM, DoseRight Cardiac) Special acquisition modes Beam filtration and beam shapers Eclipse collimator and ClearRay collimator NanoPanel detector DoseRight will cover automatic tube current selection that automatically adjusts the dose for the individual patient. The presentation will explore the modulation techniques currently employed in Philips CT scanners and will include the algorithmic concepts as well as illustrative examples. Modulation and current selection technologies to be covered include the Automatic Current Selection component of DoseRight, ZDOM longitudinal dose modulation, 3D-DOM (combination of longitudinal and rotational dose modulation), Cardiac Dose right (an ECG based dose modulation scheme), and the DoseRight Index (DRI) IQ index. The special acquisition modes covers acquisition techniques such as prospective gating that is designed to reduce exposure to the patient through the Cardiac Step and Shoot scan mode. This mode can substitute the much higher dose retrospective scan modes for certain types of cardiac imaging. The beam filtration and beam shaper portion will discuss the variety of filtration and beam shaping configurations available on Philips scanners. This topic includes the x-ray beam characteristics, tube filtration as well as dose compensator characteristics. The Eclipse collimator, ClearRay collimator and the NanoPanel detector portion will discuss additional technologies specific to wide coverage CT that address some of the unique challenges encountered and techniques employed to optimize image quality and optimize dose utilization. The Eclipse collimator reduces extraneous exposure by actively blocking the radiation tails at either end of helical scans that do not contribute to the image generation. The ClearRay collimator and the NanoPanel detector optimize the quality of the signal that reaches the detectors by addressing the increased scattered radiation present in wide coverage and the NanoPanel detector adds superior electronic noise characteristics valuable when imaging at a low dose level. The second part of the talk will present “Advanced Reconstruction Technologies” currently available on Philips CT Scanners. The talk will cover filtered back projection (FBP), iDose4 and Iterative Model Reconstruction (IMR). Each reconstruction method will include a discussion of the algorithm as well as similarities and differences between the algorithms. Examples illustrating the merits of each algorithm will be presented, and techniques and metrics to characterize the performance of each type of algorithm will be presented. The Filtered Back projection portion will discuss and provide a brief summary of relevant standard image reconstruction techniques in common use, and discuss the common tradeoffs when using the FBP algorithm. The iDose4 portion will present the algorithms used for iDose4 as well the different levels. The meaning of different levels of iDose4 available will be presented and quantified. Guidelines for selection iDose4 parameters based on the imaging need will be explained. The different image quality goals available with iDose4 and specifically how iDose4 enables noise reduction, spatial resolution improvement or both will be explained. The approaches to leveraging the benefits of iDose4 such as improved spatial resolution, decreased noise, and artifact prevention will be described and quantified; and measurements and metrics behind the improvements will be presented. The image quality benefits in specific imaging situations as well as how to best combine the technology with other dose reduction strategies to ensure the best image quality at a given dose level will be presented. Insight into the IMR algorithm as well as contrast to the iDose4 techniques and performance characteristics will be discussed. Metrics and techniques for characterizing this class of algorithm and IQ performance will be presented. The image quality benefits and the dose reduction capabilities of IMR will be explored. Illustrative examples of the noise reduction, spatial resolution improvement, and low contrast detectability improvements of the reconstruction method will be presented: clinical cases and phantom measurements demonstrating the benefits of IMR in the areas of low dose imaging, spatial resolution and low contrast resolution are discussed and the technical details behind the measurements will be presented compared to both iDose4 and traditional filtered back projection (FBP)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent advancements in chiral spintronics: from molecular-level insights to device applications. A prospect based on the interplay between physical and chemical properties of chiral systems

This review discusses recent advancements in chiral-based spin-electronic devices achieved using suitable combinations of organic, inorganic and hybrid materials. The focus is on how chirality can be effectively used to control spin in practical applications, particularly in spintronic sensors and consumer devices. Interestingly, the underlying mechanism for this control is the chiral-induced spin selectivity (CISS) effect, which links the structural chirality of a material to its spin-selective electronic transport properties. The CISS effect arises from the observation that charge transmission in chiral systems is spin selective. Experimental evidence suggests a relationship between electron spin and the structural handedness of the material. In conclusion, this unique structure-transport relationship can be exploited to design a wide range of spintronics devices, including memory, transistors, logic gates and molecular q-bits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NASA Electronic Parts and Packaging Field Programmable Gate Array Single Event Effects Test Guideline Update

The following are updated or new subjects added to the FPGA SEE Test Guidelines manual: academic versus mission specific device evaluation, single event latch-up (SEL) test and analysis, SEE response visibility enhancement during radiation testing, mitigation evaluation (embedded and user-implemented), unreliable design and its affects to SEE Data, testing flushable architectures versus non-flushable architectures, intellectual property core (IP Core) test and evaluation (addresses embedded and user-inserted), heavy-ion energy and linear energy transfer (LET) selection, proton versus heavy-ion testing, fault injection, mean fluence to failure analysis, and mission specific system-level single event upset (SEU) response prediction. Most sections within the guidelines manual provide information regarding best practices for test structure and test system development. The scope of this manual addresses academic versus mission specific device evaluation and visibility enhancement in IP Core testing.

Field Programmable Gate Array (FPGA)↗

Three-phase Four-leg Inverter LabVIEW FPGA Control Code [SWR-16-26]

In the area of power electronics control, Field Programmable Gate Arrays (FPGAs) have the capability to outperform their Digital Signal Processor (DSP) counterparts due to the FPGA’s ability to implement true parallel processing and therefore facilitate higher switching frequencies, higher control bandwidth, and/or enhanced functionality. National Instruments (NI) has developed two platforms, Compact RIO (cRIO) and Single Board RIO (sbRIO), which combine a real-time processor with an FPGA. The FPGA can be programmed with a subset of the well-known LabVIEW graphical programming language. The use of cRIO and sbRIO for power electronics control has developed over the last few years to include control of three-phase inverters. Most three-phase inverter topologies include three switching legs. The addition of a fourth-leg to natively generate the neutral connection allows the inverter to serve single-phase loads in a microgrid or stand-alone power system and to balance the three-phase voltages in the presence of significant load imbalance. However, the control of a four-leg inverter is much more complex. In particular, instead of standard two-dimensional space vector modulation (SVM), the inverter requires three-dimensional space vector modulation (3D-SVM). The candidate software implements complete control algorithms in LabVIEW FPGA for a three-phase four-leg inverter. The software includes feedback control loops, three-dimensional space vector modulation gate-drive algorithms, advanced alarm handling capabilities, contactor control, power measurements, and debugging and tuning tools. The feedback control loops allow inverter operation in AC voltage control, AC current control, or DC bus voltage control modes based on external mode selection by a user or supervisory controller. The software includes the ability to synchronize its AC output to the grid or other voltage-source before connection. The software also includes provisions to allow inverter operation in parallel with other voltage regulating devices on the AC or DC buses. This flexibility allows the Inverter to operate as a stand-alone voltage source, connected to the grid, or in parallel with other controllable voltage sources as part of a microgrid or remote power system. In addition, as the inverter is expected to operate under severe unbalanced conditions, the software includes algorithms to accurately compute real and reactive power for each phase based on definitions provided in the IEEE Standard 1459: IEEE Standard Definitions for the Measurement of Electric Power Quantities Under Sinusoidal, Nonsinusoidal, Balanced, or Unbalanced Conditions. Finally, the software includes code to output analog signals for debugging and for tuning of control loops. The software fits on the Xilinx Virtex V LX110 FPGA embedded in the NI cRIO-9118 FPGA chassis, and with a 40 MHz base clock, supports a modulation update rate of 40 MHz, user-settable switching frequencies and synchronized control loop update rates of tens of kHz, and reference waveform generation, including Phase Lock Loop (PLL), update rate of 100 kHz.

Martin, Gregory↗

NASA Electronic Parts and Packaging (NEPP) Field Programmable Gate Array (FPGA) Single Event Effects (SEE) Test Guideline Update

The following are updated or new subjects added to the FPGA SEE Test Guidelines manual: academic versus mission specific device evaluation, single event latch-up (SEL) test and analysis, SEE response visibility enhancement during radiation testing, mitigation evaluation (embedded and user-implemented), unreliable design and its affects to SEE Data, testing flushable architectures versus non-flushable architectures, intellectual property core (IP Core) test and evaluation (addresses embedded and user-inserted), heavy-ion energy and linear energy transfer (LET) selection, proton versus heavy-ion testing, fault injection, mean fluence to failure analysis, and mission specific system-level single event upset (SEU) response prediction. Most sections within the guidelines manual provide information regarding best practices for test structure and test system development. The scope of this manual addresses academic versus mission specific device evaluation and visibility enhancement in IP Core testing.

Test guidelines↗

Wafer-scale growth of two-dimensional, phase-pure InSe

Two-dimensional (2D) indium monoselenide (InSe) has attracted significant attention as an ultrathin III–VI semiconductor with a combination of favorable attributes that are comparable to those of III–V semiconductors and van der Waals 2D transition-metal dichalcogenides. Nevertheless, there has been no demonstration of large-area synthesis of 2D InSe due to the complexity of the binary In-Se system and the difficulties in promoting lateral growth. Here, we report the polymorph-selective synthesis of epitaxial 2D InSe by metal-organic chemical vapor deposition (MOCVD) over 2-in wafers. We achieve polymorph-selective epitaxial growth of InSe on c-plane sapphire via flow modulation to control the Se/In ratio. The layer-by-layer growth allows thickness control with tunable optical properties comparable to those of bulk crystals. We also demonstrate gate-tunable electrical transport with a field-effect mobility comparable to that of single-crystalline flakes. Importantly, these results indicate that InSe grown by MOCVD could be an effective channel material for back-end-of-line integration in logic transistors.

2D materials↗

Fast BPM data distribution for global orbit feedback using commercial gigabit ethernet technology

In order to correct beam perturbations in RHIC around 10Hz, a new fast data distribution network was required to deliver BPM position data at rates several orders of magnitude above the capability of the existing system. The urgency of the project limited the amount of custom hardware that could be developed, which dictated the use of as much commercially available equipment as possible. The selected architecture uses a custom hardware interface to the existing RHIC BPM electronics together with commercially available Gigabit Ethernet switches to distribute position data to devices located around the collider ring. Using the minimum Ethernet packet size and a field programmable gate array (FPGA) based state machine logic instead of a software based driver, real-time and deterministic data delivery is possible using Ethernet. The method of adapting this protocol for low latency data delivery, bench testing of Ethernet hardware, and the logic to construct Ethernet packets using FPGA hardware will be discussed. A robust communications system using almost all commercial off-the-shelf equipment was developed in under a year which enabled retrofitting of the existing RHIC BPM system to provide 10 KHz data delivery for a global orbit feedback scheme using 72 BPMs. Total latencies from data acquisition at the BPMs to delivery at the controller modules, including very long transmission distances, were kept under 100 {micro}s, which provide very little phase error in correcting the 10 Hz oscillations. Leveraging off of the speed of Gigabit Ethernet and wide availability of Ethernet products enabled this solution to be fully implemented in a much shorter time and at lower cost than if a similar network was developed using a proprietary method.

43 PARTICLE ACCELERATORS↗

Wire like link for cycle reproducible and cycle accurate hardware accelerator

First and second field programmable gate arrays are provided which implement first and second blocks of a circuit design to be simulated. The field programmable gate arrays are operated at a first clock frequency and a wire like link is provided to send a plurality of signals between them. The wire like link includes a serializer, on the first field programmable gate array, to serialize the plurality of signals; a deserializer on the second field programmable gate array, to deserialize the plurality of signals; and a connection between the serializer and the deserializer. The serializer and the deserializer are operated at a second clock frequency, greater than the first clock frequency, and the second clock frequency is selected such that latency of transmission and reception of the plurality of signals is less than the period corresponding to the first clock frequency.

97 MATHEMATICS AND COMPUTING↗

Toward simulating quantum field theories with controlled phonon-ion dynamics: A hybrid analog-digital approach

Quantum field theories are the cornerstones of modern physics, providing relativistic and quantum mechanical descriptions of physical systems at the most fundamental level. Simulating real-time dynamics within these theories remains elusive in classical computing. This provides a unique opportunity for quantum simulators, which hold the promise of revolutionizing our simulation capabilities. Trapped-ion systems are successful quantum-simulator platforms for quantum many-body physics and can operate in digital, or gate-based, and analog modes. Inspired by the progress in proposing and realizing quantum simulations of a number of relativistic quantum field theories using trapped-ion systems, and by the hybrid analog-digital proposals for simulating interacting boson-fermion models, we propose hybrid analog-digital quantum simulations of selected quantum field theories, taking recent developments to the next level. On one hand, the semi-digital nature of this proposal offers more flexibility in engineering generic model interactions compared with a fully-analog approach. On the other hand, encoding the bosonic fields onto the phonon degrees of freedom of the trapped-ion system allows a more efficient usage of simulator resources, and a more natural implementation of intrinsic quantum operations in such platforms. This opens up new ways for simulating complex dynamics of e.g., Abelian and non-Abelian gauge theories, by combining the benefits of digital and analog schemes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Asymmetric Nafion-Coated Nanopore Electrode Arrays as Redox-Cycling-Based Electrochemical Diodes

Inspired by the functioning of cellular ion channels, pore-based structures with nanoscale openings, have been fabricated and integrated into ionic circuits, e.g. ionic diodes and transistors, for signal processing and detection. In these systems, the nonlinear current responses arise either because asymmetric nanopore geometries break the symmetry of the ion distribution, creating unequal surface charge across the nanopore, or by coupling unidirectional electron transfer within a nanopore electrode. Here, we develop a high-performance redox cycling-based electrochemical diode by coating an asymmetric ion-exchange membrane, i.e. Nafion, on the top surface of a nanopore electrode array (Nafion@NEA), in which each pore in the array exhibits one or more annular electrodes. Nafion@NEAs exhibit highly sensitive and charge-selective electroanalytical measurements due to efficient redox cycling reaction, the permselectivity of Nafion, and strong confinement of redox species in the nanopore array. In addition, the top electrode of dual electrode Nafion@NEAs can serve as a voltage-controlled switch to gate ion transport within the nanopore. Thus, Nafion@NEAs can be operated as a diode by switching voltages applied to the top and bottom electrodes of the NEA, leading to a large rectification ratio, fast response times, and simplified circuitry without the need for external electrodes. Here by taking advantage of closely spaced and individually addressable electrodes, the redox cycling electrochemical diode has the potential for application to large-scale production and electrochemically-controlled circuit operations which go well beyond conventional electronic diodes or transistors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using G4FETs as a Data Router for In-Plane Crossing of Signal Paths

Theoretical analysis and some experiments have demonstrated that siliconon- insulator (SOI) 4-gate transistors the type known as G(exp 4)FETs could be efficiently used for in-plane crossing of signal paths. Much of the effort of designing very-large-scale integrated (VLSI) circuits is focused on area-efficient routing of signals. The main source of difficulty in VLSI signal routing is the requirement to prevent crossing, in the same plane, of wires that are meant to be kept electrically insulated from each other. Consequently, it often becomes necessary to design and build VLSI circuits in multiple layers with vias (connections between conductors in different layers at selected locations). Suitable devices that would prevent, or at least sufficiently suppress, undesired electrical coupling (cross-talk) between wires crossing in the same plane would enable compact, simpler implementation complex interconnection networks with in-plane crossings that, heretofore, have not been possible in VLSI circuitry. The use of G4FETs as in-plane signal-crossing devices or routers, in combination with the use of G(exp 4)FETs as universal programmable logic gates, would create opportunities for reducing complexity in VLSI design.

Fijany, Amir↗

X-ray Characterization of a Multichannel Smart-Pixel Array Detector

The Voxtel VX-798 is a prototype X-ray pixel array detector (PAD) featuring a silicon sensor photodiode array of 48 x 48 pixels, each 130 mu m x 130 mu m x 520 mu m thick, coupled to a CMOS readout application specific integrated circuit (ASIC). The first synchrotron X-ray characterization of this detector is presented, and its ability to selectively count individual X-rays within two independent arrival time windows, a programmable energy range, and localized to a single pixel is demonstrated. During our first trial run at Argonne National Laboratory's Advance Photon Source, the detector achieved a 60 ns gating time and 700 eV full width at half-maximum energy resolution in agreement with design parameters. Each pixel of the PAD holds two independent digital counters, and the discriminator for X-ray energy features both an upper and lower threshold to window the energy of interest discarding unwanted background. This smart-pixel technology allows energy and time resolution to be set and optimized in software. It is found that the detector linearity follows an isolated dead-time model, implying that megahertz count rates should be possible in each pixel. Measurement of the line and point spread functions showed negligible spatial blurring. When combined with the timing structure of the synchrotron storage ring, it is demonstrated that the area detector can perform both picosecond time-resolved X-ray diffraction and fluorescence spectroscopy measurements.

CMOS ASIC↗

ARETE: Accurate Error Assessment via Machine Learning-Guided Dynamic-Timing Analysis

Nanometer circuits are increasingly prone to timing errors, escalating the need for fault injection frameworks to accurately evaluate their impact on applications. Here in this paper, we propose ARETE, a novel cross-layer, fault-injection framework that combines dynamic-binary instrumentation with machine learning-guided dynamic-timing analysis. ARETE enables accurate fault-injection into any application by estimating the location of the injecting errors via dynamic-timing analysis. To accelerate fault-injection, we develop a novel, data-aware, machine learning-based mechanism that dynamically pre-selects the error-prone instructions and limits the application of the costly dynamic-timing analysis only to them. To evaluate ARETE's accuracy, our fully automated toolflow is configured to support fault-injection based on detailed post-layout gate-level simulations as well as via existing workload-agnostic error models. Our results for various workloads, including an autonomous-driving library, show that the location and time of injected errors performed by ARETE, is 89.9% consistent with fault-injection based on full gate-level simulation. On average, ARETE executes 84.6x faster than gate-level simulation and at a cost of 3.4% loss in the program output quality estimation. When compared to the existing statistical fault-injection tools that are based on workload-agnostic error models, ARETE improves the accuracy of fault-injection rate and output quality estimation by 143.9% and 40.4% on average, respectively.

97 MATHEMATICS AND COMPUTING↗

One-dimensional air temperature measurements by air resonance enhanced multiphoton Ionization thermometry (ART)

In this work, a detailed calibration study is performed to establish non-intrusive one-dimensional (1D) rovibrational temperature measurements in unseeded air, based on air resonance enhanced multiphoton ionization thermometry (ART). ART is generated by REMPI (resonance enhanced multi-photon ionization) of molecular oxygen and subsequent avalanche ionization of molecular nitrogen in a single laser pulse. ART signal, the fluorescence from the first negative band of molecular nitrogen, is directly proportional to the 2-photon transition of molecular oxygen C 3 Π (v = 2) ← X 3 Σ (v’=0), which is used to determine temperature. Experimentally, hyperfine structures of the O 2 rotational branches with high temperature sensitivity are selectively excited through a frequency-doubled dye laser. Electron-avalanche ionization of N 2 results in the fluorescence emissions from the first negative bands of N 2 + near 390, 425, and 430nm, which are captured as a 1D line by a gated intensified camera. Post processing of the N 2 + fluorescence yields a 1D thermometry line that is representative of the air temperature. It is demonstrated that the technique provides ART fluorescence of ∼5cm in length in the unseeded air, presenting an attractive thermometry solution for high-speed wind tunnels and other ground test facilities.

42 ENGINEERING↗

Tandem Mass Spectrometry on a Miniaturized Laser Desorption Time-of-Flight Mass Spectrometer

Tandem mass spectrometry (MSMS) is a powerful and widely-used technique for identifying the molecular structure of organic constituents of a complex sample. Application of MSMS to the study of unknown planetary samples on a remote space mission would contribute to our understanding of the origin, evolution, and distribution of extraterrestrial organics in our solar system. Here we report on the realization of MSMS on a miniaturized laser desorption time-of-flight mass spectrometer (LD-TOF-MS), which is one of the most promising instrument types for future planetary missions. This achievement relies on two critical components: a curved-field reflectron and a pulsed-pin ion gate. These enable use of the complementary post-source decay (PSD) and laser-assisted collision induced dissociation (L-CID) MSMS methods on diverse measurement targets with only modest investment in instrument resources such as volume and weight. MSMS spectra of selected molecular targets in various organic standards exhibit excellent agreement when compared with results from a commercial, laboratory-scale TOF instrument, demonstrating the potential of this powerful technique in space and planetary environments.

Li, Xiang↗

Disentangling interlayer confinement and pore surface adsorption in functionalized smectites for tunable ethylene gas capture

Smectite-based adsorbents are increasingly being studied as sustainable packaging materials for scavenging ethylene, a plant hormone that accelerates fruit ripening. However, the mechanisms governing their uptake and retention remain poorly understood. Here, to tackle this question we systematically investigate ethylene gas-solid interactions in pristine, acid-activated, and choline-functionalized montmorillonites using a complementary combination of structural, gravimetric, and spectroscopic techniques, including inelastic neutron scattering. We experimentally distinguish ethylene populations associated with interlayer confinement, mesopore, and external surface adsorption. We show that chemical functionalization distinctly controls adsorption pathways: acid activation enhances total uptake by generating mesoporous adsorption sites and promoting partial interlayer intercalation, yielding capacities comparable to those of leading smectite-based adsorbents, while choline functionalization promotes preferential confinement and stabilization of guest molecules within the interlayer galleries. Advanced spectroscopic analysis provides molecular-level insight into confinement environments and interaction strengths. We also establish clear structure-property relationships by correlating uptake values derived from independent techniques, linking chemical modification, accessible adsorption domains, and retention behavior. These findings provide general design principles for tuning gas-solid interactions in functionalized layered silicates and highlight their potential as adaptable platforms for sustainable ethylene gas capture and selective adsorption technologies.

Ethylene adsorption mechanism↗

Temporal Gating of Synaptic Competition in the Amygdala by Cannabinoid Receptor Activation

Abstract The acquisition of fear memories involves plasticity of the thalamic and cortical pathways to the lateral amygdala (LA). In turn, the maintenance of synaptic plasticity requires the interplay between input-specific synaptic tags and the allocation of plasticity-related proteins. Based on this interplay, weakly activated synapses can express long-lasting forms of synaptic plasticity by cooperating with strongly activated synapses. Increasing the number of activated synapses can shift cooperation to competition. Synaptic cooperation and competition can determine whether two events, separated in time, are associated or whether a particular event is selected for storage. The rules that determine whether synapses cooperate or compete are unknown. We found that synaptic cooperation and competition, in the LA, are determined by the temporal sequence of cortical and thalamic stimulation and that the strength of the synaptic tag is modulated by the endocannabinoid signaling. This modulation is particularly effective in thalamic synapses, supporting a critical role of endocannabinoids in restricting thalamic plasticity. Also, we found that the availability of synaptic proteins is activity-dependent, shifting competition to cooperation. Our data present the first evidence that presynaptic modulation of synaptic activation, by the cannabinoid signaling, functions as a temporal gating mechanism limiting synaptic cooperation and competition.

Madeira, Natália↗

Synthesis, crystal structure and optical property of three coordination polymer constructed from m-phenylenediacrylate acid

Three new complexes of the wholly deprotonated flexible ligand m-phenylenediacrylate acid (H{sub 2}mpda), namely, [Zn (mpda) (H{sub 2}O)] [1], [Pr{sub 2}(mpda){sub 2}(H{sub 2}O){sub 2}(CHOO){sub 2}] [2], and [Mn{sub 2}(mpda){sub 2} (H{sub 2}O){sub 4}] [3], were synthesized by the solvothermal reaction. The complexes were characterized by IR spectroscopy, thermogravimetric analysis, and X-ray single-crystal diffraction. A mixed sample [Nd(mpda)(H{sub 2}O)(CHOO)·Pr(mpda)(H{sub 2}O)(CHOO)] [2{sup ]} was also synthesized and studied. Compounds [1] and [2] exhibit a selective sensing function with respect to acetone, and they are a potential luminescent sensory material for the selective detection of Zn{sup 2+} and Ni{sup 2+} ions, respectively. Furthermore, the fluorescent changes of compound [1] upon the addition of cations (Fe{sup 3+} and Zn{sup 2+}, Bi{sup 2+} and Zn{sup 2+}) are utilized to construct two logic gates at the molecular level. - Graphical abstract: Three new complexes of flexible ligand m-phenylenedicarboxylic acid were synthesized by solvothermal reaction. Three metal−organic frameworks exhibiting 1D, 2D, 3D structures, respectively. - Highlights: • Three new complexes of m-phenylenedicarboxylic acid were synthesized. • Three metal−organic frameworks exhibiting 1D, 2D, 3D structures, respectively. • [1] and [2] exhibits a very high quenching effect with acetone. • [1] and [2] are a potential luminescent sensory material for Zn{sup 2+}, Ni{sup 2+} ions. • Two logic gates have been constructed using compound [1].

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗