A Path to Navigating the Storm: Load Forecasting and Increasing Resilience in Puerto Rico

Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100) provided a comprehensive analysis of pathways for Puerto Rico to achieve its goal of 100% renewable energy by 2050, based on extensive stakeholder input. The study illuminates immediate and longer-term investments needed to achieve reliability while pursuing Puerto Rico's energy goals and addressing critical energy needs. Expected benefits of these investments include improvements in safety, security, health, and economic opportunity.

ENERGY PLANNING, POLICY, AND ECONOMY↗

A cell-centered AMR-ALE framework for 3D multi-material hydrodynamics. Part I: Lagrangian and indirect Euler AMR algorithms

Many applications of physics and engineering involve wide ranges of time and spatial scales. The numerical simulation of localized small scales such as shock waves and material interfaces requires a large number of computational cells in these regions. For these applications, Lagrangian and Arbitrary-Lagrangian-Eulerian (ALE) related methods are engaging since the moving mesh feature naturally brings mesh cells on shock discontinuities and material interfaces are carefully captured. In addition, Adaptive-Mesh-Refinement (AMR) strategies aim to optimize computational resources by concentrating finer mesh cells only in areas of interest while using coarser cells elsewhere. A key but challenging AMR requirement consists in efficiently distributing the computational effort to achieve high accuracy without the prohibitive computational costs associated with uniformly fine grids. Here, in this document, the coupling of the p4est AMR library with a cell-centered Lagrangian scheme is presented with the goal to perform reliable 3D Lagrangian-AMR and indirect Euler-AMR multi-material simulations. In particular, it is shown that starting from a 3D indirect ALE code, the memory management and load balancing requirements can be delegated to an external library (here the p4est library) to unlock ALE-AMR capabilities. First, we present a strategy to transcribe the octant-based connectivity of the 3D AMR framework with that of an unstructured mesh of polygonal cells used in Lagrangian hydrodynamics. Then, we show how refinement and coarsening operations must be adapted to the particular Lagrangian framework to ensure the conservation of volume during those steps. Finally, several numerical test cases are presented that demonstrate the capabilities of the Lagrangian-AMR and indirect Euler-AMR algorithms.

3D cell-centered Lagrangian numerical scheme↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of the Protection Improvements for a Weak Grid Area With High Inverter-Based Resources (IBRs)

This project designs enhanced protection scheme for the real-world weak grid area with a high penetration of IBRs. As the existing protection schemes are originally designed for traditional synchronous machines, we first evaluate if the protection scheme will continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with IBR original equipment manufacturer black-box models is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. Enhanced protection is designed to address the challenge of lack of negative sequence current from IBRs, including increased restraining factors a2 and k2 to block 32Q or using V instead QV ORDER for ground faults, enhanced mho distance element with voltage and phase angle supervision for L-L faults. The efficacy of enhanced protection logic is validated and proven to work reliably. Additionally, IEEE Std. 2800-2022 negative sequence current compliant GFL and GFM IBRs from another vendor are tested and proven to work reliably without need for enhanced logic. Therefore, this work provides valuable decision-making for utilities facing protection system challenges due to IBRs, either designing enhanced protection scheme or requesting their IBRs being IEEE Std. 2800-2022 compliant to produce regulated negative sequence current for protection relay to make correct decision.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy and AI: Evaluating Future Grid and Water Stress Due to Data Centers

Projections of the need for new data centers to support Artificial Intelligence (AI) are large but highly uncertain. Recent projections indicate up to a 15% annual growth rate in data center electricity demand within the next 5-10 years. Given that most electric utilities are required to have a reserve margin of roughly the same magnitude as the projected growth in demand, these new data center loads could soon threaten resource adequacy and reliability unless data centers build their own generation, interruptible loads are negotiated, commensurate new capacity and/or transmission is built, or some combination of these options. Similarly, depending on the cooling technology and geographic location of new data centers, they could threaten water adequacy in water scarce regions. This presentation highlights the grid and water implications of new data centers to support AI.

Mongird, Kendall (ORCID:0000000328077088)↗

Dynamic Line Rating Models and Their Potential for a Cost‐Effective Transition to Carbon‐Neutral Power Systems

Most transmission system operators (TSOs) currently use seasonally steady-state models considering limiting weather conditions that serve as reference to compute the transmission capacity of overhead power lines. The use of dynamic line rating (DLR) models can avoid the construction of new lines, market splitting, false congestions, and the degradation of lines in a cost-effective way. DLR can also be used in the long run in grid extension and new power capacity planning. In the short run, it should be used to help operate power systems with congested lines. The operation of the power systems is planned to have the market trading into account; thus, it computes transactions hours ahead of real-time operation, using power flow forecasts affected by large errors. In the near future, within a “smart grid” environment, in real-time operation conditions, TSOs should be able to rapidly compute the capacity rating of overhead lines using DLR models and the most reliable weather information, forecasts, and line measurements, avoiding the current steady-state approach that, in many circumstances, assumes ampacities above the thermal limits of the lines. Here, this work presents a review of the line rating methodologies in several European countries and the United States. Furthermore, it presents the results of pilot projects and studies considering the application of DLR in overhead power lines, obtaining significant reductions in the congestion of internal networks and cross-border transmission lines.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Systems Integration Facility Stewardship Summary: Fiscal Year 2025

A summary of NLR's stewardship of the nationally unique Energy Systems Integration Facility (ESIF) highlighting performance metrics, capability upgrades, and examples of R&D impact. 2025 brought a national focus on energy and ESIF is meeting the moment. All eyes are on data centers and domestic manufacturing and bringing the benefits of artificial intelligence to power system planning and operations. In step with national priorities, ESIF is building out capabilities that advance secure, reliable, and affordable power. ESIF hosted 190 multidisciplinary research projects, 855 high-performance computer users, and collaborated with 81 partners from industry, academia, research, and federal agencies. These research projects resulted in an AI method for detecting high-impedance faults with 90% accuracy, a grid controls demonstration in Connecticut, power quality validation of CorePower's flagship inductor, and a cybersecurity assessment of potential rogue capabilities in digitally connected energy devices. Facility infrastructure improvements enhanced the thermal research network, the SCADA system, the cyber range, power hardware-in-the-loop testing, and more. With support from the U.S Department of Energy (DOE), the ESIF laboratories continue to deliver leading solutions for secure, reliable, and affordable power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Limiter-aware adaptive excitation control for hydropower generators with legacy voltage regulation systems

Hydropower units often rely on legacy excitation systems with fixed automatic voltage regulator (AVR) settings, but parameter drift, changing operating conditions, and evolving grid-service demands can degrade terminal-voltage regulation over time. This problem should be addressed because poor voltage regulation affects reactive-power support, system stability, and reliable plant operation, and replacing installed AVR and limiter logic is costly and disruptive in practice. To address this issue, this paper proposes a retrofit-friendly enhancement for hydropower generator excitation systems that combines adaptive tuning of the AVR middle lead–lag branch with a small proportional-integral correction for removing steady bias and slow drift. The adaptive laws are normalized, projection-bounded, and equipped with leakage, while adaptation is enabled only in the middle branch. Thus, the intent of the underexcitation and overexcitation limiters, as well as legacy current and rate limits, remains unchanged. Stability is analyzed under incremental performance assumptions, yielding boundedness and asymptotic tracking in the absence of saturation. The method is evaluated using real operational data from a utility-scale hydropower unit at Rocky Reach Dam, Unit C-8. Compared with the fixed AVR baseline, the proposed method reduces terminal-voltage mean squared error by about 70%, removes long periods of steady-state bias, and improves transient tracking while coexisting with limiter actions. These results show that substantial voltage-control improvement can be achieved on existing hydropower units with minimal integration effort and without replacing the installed AVR structure.

ESST5B model↗

A Data-Driven Exploration of the Impact of Renewable Energy on Inter-Area Oscillations in the U.S. Eastern Interconnection

As increasing amounts of renewable energy (RE) resources are incorporated into the bulk-power grid, power system oscillations are expected to change. This work investigates how RE generation impacts the frequency and damping ratio (DR) of two dominant inter-area modes in the U.S. Eastern Interconnection (EI) using regularly updated estimates collected over a 12-month period. Quantile regression is used to derive the correlation between operating conditions and mode properties, and a bootstrap method is used to quantify the uncertainty associated with the correlation estimates. Results show that with an increase in system load, the frequency of a mode decreases and DR increases. Evidence that increasing RE generation results in an increase in frequency and decline in DR was found for one of the two modes studied. This work shows that increasing RE levels will impact the properties of inter-area oscillations in the EI, but it does not indicate the presence of immediate threats to grid stability. The outlined approach can be used to periodically assess changing mode properties as RE levels continue to grow and flag stability concerns before they become serious reliability threats.

Inter-area oscillation, mode meters, quantile regr↗

Raccoon density estimation from camera traps for raccoon rabies management

Abstract Density estimation for unmarked animals is particularly challenging, yet density estimates are often necessary for effective wildlife management. Raccoons ( Procyon lotor ) are the primary terrestrial wildlife reservoir for Lyssavirus rabies within the United States. The raccoon rabies variant (RRVV) is actively managed at landscape scales using oral rabies vaccination (ORV) within the eastern United States. To effectively manage RRVV, it is important to know the density of raccoons to appropriately scale the density of ORV baits distributed on the landscape. We compared methods to estimate raccoon densities from camera‐trap data versus more intensive capture‐mark‐recapture (CMR) estimates across 2 land cover types (upland pine and bottomland hardwood) in the southeastern United States during 2019 and 2020. We evaluated the effect of alternative camera configurations and durations of camera trapping on density estimates and used an N‐mixture model to estimate raccoon densities, including covariates on abundance and detection. We further compared different methods of scaling camera‐based counts, with the maximum number of raccoons seen on any given image within a day best explaining density. Camera‐trap density estimates were moderately correlated with CMR estimates ( r = 0.56). However, densities from camera‐trap data were more reliable when classifying category of density as an index used to inform management (83% correct when compared to CMR estimates), although the densities in our study fell into the 2 lowest density classes only. Using more cameras reduced bias and uncertainty around density estimates; however, if ≤6 camera traps were used at a site, a line transect approach proved less biased than a grid design. Camera trapping should be conducted for at least 3 weeks for more accurate estimates of raccoon population density in our study area (<5% bias). We show that camera‐trap data can be used to assign raccoon densities to management‐relevant density index bins, but more studies are needed to ensure reliability across a greater range of environmental conditions and raccoon densities.

Davis, Amy J.↗

A Hybrid Fuel Cell and Battery Storage Power Management for Grid-Interactive EV Charging Station

With the increasing adoption of renewable energy sources in grid-interactive Electric Vehicle (EV) charging stations, the role of energy storage systems has become critical. While large energy storage systems have mitigated the intermittency of renewable energy, integrating multi-source energy management with prioritized charging can further enhance the reliability of charging stations (CS). This paper presents a decentralized energy management (DEM) approach combining battery energy storage (BES) and fuel cell (FC) systems using a rule-based line resistance correction droop (LRCD) control technique. The proposed droop control dynamically adjusts the gain to balance the state-of-charge (SoC) of the BES, enhancing power support longevity and improving battery life under varying capacity conditions by reducing current stress. Additionally, the paper addresses the challenges of using fuel cells in linear regions to optimize efficiency and manage various charging scenarios. The CS integrates unity power factor grid interaction, and power support for auxiliary loads, maintaining harmonic distortion within 5% during grid islanding. The approach evaluates DC bus voltage regulation under various scenarios of PV array power fluctuations and dynamic load variations, in both grid-connected and standalone operations. In conclusion, the proposed control strategy is validated on a laboratory prototype through various dynamic load variation and grid islanding scenarios.

Khalid, Mohd [Oak Ridge National Laboratory (ORNL)↗

Challenges and Opportunities for Electric Utility Modeling and Asset Valuation Frameworks: Case Study on Valuing New Pumped Storage Hydropower

Asset valuation by electric utilities is becoming increasingly difficult in the rapidly changing electric sector. Rapid deployment of variable generation and inverter-based storage systems along with uncertain demand growth, climate, policies, and other factors create a challenging environment for understanding the value proposition of a new potential asset. This report describes an effort between the Tennessee Valley Authority (TVA) and three U.S. Department of Energy laboratories to perform a detailed review of utility modeling and analysis practices for asset valuation and identify challenges and opportunities for advancing its methods into the future. It focuses on a case study of new potential pumped storage hydropower (PSH) because of growing interest in new PSH capacity to provide energy balancing, firm capacity, and a range of ancillary services. Staff from the DOE labs conducted systematic interviews about current practices in capacity expansion modeling, production-cost modeling, hydrological modeling, and transmission stability modeling while also discussing how scenario analysis is conducted and how models and data are integrated. The effort resulted in a set of model, integration, and scenario recommendations that could be valuable to TVA, other utilities, system operators, and other stakeholders conducting integrated grid analysis. Individual model recommendations suggest exploring computational tradeoffs with detail and resolution across spatiotemporal structure, supply- and demand-side details, transmission overlays, market interactions, and ancillary services. Automated processes to pass data between models and conduct larger scenario suites could also enhance valuation practices by enabling a more consistent study of asset value across a broader range of uncertain future grid conditions where PSH could be particularly valuable. TVA and other industry stakeholders can learn from and adapt applied research-grade methods developed by DOE laboratories and other research institutions to improve decision making and accelerate progress towards a reliable, economic, sustainable energy system.

13 HYDRO ENERGY↗

A Sequential Model Predictive and Deep Reinforcement Learning-Based Controller for Distribution System Outage Mitigation under Hurricane Events

This paper proposes a proactive outage mitigation framework for power distribution networks to withstand hurricane-induced disruptions. It leverages Model Predictive Control (MPC) to identify safe lines for proactive switching during hurricanes, minimizing the risk of cascading failures and voltage violations. The switching strategies optimized by MPC are sequentially integrated with a Deep Reinforcement Learning agent using the Advantage Actor-Critic algorithm, enabling dynamic line switching to maximize connected buses and minimize voltage violations in real time. Using a probabilistic hurricane model, the framework predicts line failures and adapts to varying conditions to enhance grid resilience. Simulations on the IEEE 123-bus system demonstrate its effectiveness in maintaining high connectivity and minimizing disruptions. Real-time testing with an RTDS confirms the practicality and reliability of the proposed approach.

Selim, Alaa [University of Connecticut]↗

Data-driven Modeling for Grid Edge IBRs: A Digital Twin Perspective of User-Defined Models

Recent events in Odessa have brought attention to the challenges associated with the interaction between Inverter- Based Resources (IBRs) and the transmission and distribution system. The NERC event diagnosis report has highlighted sev- eral issues, emphasizing the need for continuous performance monitoring of these IBRs by system operators. Key areas of concern include the mismatch of control and protection perfor- mance of IBRs between the original equipment manufacturer (OEM)-provided models and field measurements. The inability to replicate the realistic response can result in incorrect reliability and resilience studies. In this paper, we developed an approach on how to emulate the behavior of an IBR using measurement data obtained for system operators to utilize in real-time and long- term planning. Two experiments are conducted in the phasor domain and electromagnetic transients (EMT) domain to emulate the behavior for grid forming and grid following inverters under various operating conditions and the effectiveness of the proposed model is demonstrated in terms of accuracy and ease of utilizing user-defined models (UDMs)

Mahapatra, Kaveri [BATTELLE (PACIFIC NW LAB)]↗

Assessing Photovoltaic Capacity Factor Variability Using Long-Term Satellite Derived Solar Resource Data Under Brazilian Climate

Accurate estimation of photovoltaic (PV) energy yield and its variability is essential for reducing financial risk and supporting reliable system planning for rapidly expanding PV markets. In Brazil, high solar adoption and increasing levels of distributed energy resources are beginning to introduce operational challenges such as curtailment and evolving grid requirements. Understanding how natural variability in solar resource propagates into PV system performance is therefore increasingly important for both project design and grid integration. Modern PV yield assessments commonly rely on multi-year meteorological datasets and probabilistic exceedance metrics (e.g., P50/P90) to quantify energy yield uncertainty for project financing. However, the implications of long-term solar resource variability for PV system design choices and high-adoption grid conditions remain less well characterized for rapidly expanding markets such as Brazil. In particular, understanding how weather-driven variability propagates into PV production distributions and capacity factor expectations is important for evaluating curtailment exposure, deployment strategies, and storage requirements in regions experiencing rapid growth of distributed and utility-scale PV. Seasonal and interannual variability in atmospheric conditions can produce substantial fluctuations in monthly PV energy production, which propagate into uncertainty in annual energy yield and capacity factor expectations. Characterizing this variability using long-term meteorological datasets allows probabilistic estimation of PV system performance and provides improved insight into the range of expected PV energy outcomes. This study explores the use of long-term satellite-derived meteorological data from the National Solar Radiation Database (NSRDB) to evaluate the variability of photovoltaic system performance across multiple locations in Brazil. Using a 27-year dataset (1998-2024), PV system simulations are performed to characterize the distribution of annual and seasonal capacity factors and energy yield outcomes, while propagating key sources of meteorological variability and model uncertainty through the PV modeling chain. The analysis also investigates the sensitivity of PV performance outcomes to key system design assumptions within the PV modeling chain, including tracking configuration and system sizing parameters. The resulting probabilistic performance characterization provides insight into how weather-driven variability influences PV production expectations and capacity factor distributions. These results provide a foundation for evaluating how weather-driven variability interacts with high PV adoption and potential storage or curtailment mitigation strategies.

14 SOLAR ENERGY↗

Average and Marginal Capacity Credit Values of Renewable Energy and Battery Storage in the United States Power System

As deployment of renewable resources and storage continue to significantly grow in the coming decades, these technologies will play increasingly important roles in maintaining power systems' resource adequacy. Few analyses so far offer comprehensive comparisons of forward-looking average and marginal capacity credits of variable renewable energy and storage in the U.S. interconnections across a wide range of possible futures. To fill this research gap, we quantify the average and marginal capacity credits of solar PV, onshore and offshore wind, and batteries between 2026 and 2050 across the U.S power systems to examine the temporal trends, spatial patterns, and trade-offs between these two capacity accreditation approaches. Across technologies, capacity credits of solar PV most clearly follow downward trends over time, reflecting the significant rise in solar PV generation share as the grid decarbonizes. While battery storages' generation shares also rise significantly over time, their capacity credits always remain stably high due to their capabilities to be dispatched strategically during critical periods to maintain reliability. On the other hand, capacity credits of wind technologies in general follow slight upward trends as their generation shares level off. There are strong spatial variabilities of both average and marginal capacity credits across technologies, but capacity credits of solar PV displaying the most obvious spatial patterns with high capacity credits concentrating in wind-rich, solar-poor regions in SPP, PJM, and MISO, suggesting potential reliability benefits of interconnection-wide planning for renewable energy deployments. Additionally, except for offshore wind, average capacity credits of all other renewable technologies tend to be higher than their marginal capacity credits, indicating that existing renewable resources tend to be accredited higher than new resources at almost any time.