At least 451 records · Page 25

L-NAME, a nitric oxide synthase inhibitor, as a potential countermeasure to post-suspension hypotension in rats

A large number of astronauts returning from spaceflight experience orthostatic hypotension. This hypotension may be due to overproduction of vasodilatory mediators, such as nitric oxide (NO) and prostaglandins. To evaluate the role of the NO synthase inhibitor NG-nitro-L-arginine methyl ester (L-NAME) as a countermeasure against the post-suspension reduction in mean arterial pressure (MAP), we assessed the cardiovascular responses and vascular reactivity to 7-day 30 degrees tail-suspension and a subsequent 6 hr post-suspension period in conscious rats. After a pre-suspension reading, direct MAP and heart rate (HR) were measured daily and every 2 hrs post-suspension. The NO synthase inhibitor L-NAME (20 mg/kg, i.v.), or saline, were administered after the 7th day reading prior to release from suspension and at 2 and 4 hrs post-suspension. At 6 hrs post-suspension, vascular reactivity was assessed. While MAP did not change during the suspension period, it was reduced post-suspension. Heart rate was not significantly altered. L-NAME administration reversed the post-suspension reduction in MAP. In addition, the baroreflex sensitivity for heart rate was modified by L-NAME. Thus, the post-suspension reduction in MAP may be due to overproduction of NO and altered baroreflex activity.

NASA Discipline Cardiopulmonary↗

Absence of arterial baroreflex modulation of skin sympathetic activity and sweat rate during whole-body heating in humans

1. Prior findings suggest that baroreflexes are capable of modulating skin blood flow, but the effects of baroreceptor loading/unloading on sweating are less clear. Therefore, this project tested the hypothesis that pharmacologically induced alterations in arterial blood pressure in heated humans would lead to baroreflex-mediated changes in both skin sympathetic nerve activity (SSNA) and sweat rate. 2. In seven subjects mean arterial blood pressure was lowered (approximately 8 mmHg) and then raised (approximately 13 mmHg) by bolus injections of sodium nitroprusside and phenylephrine, respectively. Moreover, in a separate protocol, arterial blood pressure was reduced via steady-state administration of sodium nitroprusside. In both normothermia and heat-stress conditions the following responses were monitored: sublingual and mean skin temperatures, heart rate, beat-by-beat blood pressure, skin blood flow (laser-Doppler flowmetry), local sweat rate and SSNA (microneurography from peroneal nerve). 3. Whole-body heating increased skin and sublingual temperatures, heart rate, cutaneous blood flow, sweat rate and SSNA, but did not change arterial blood pressure. Heart rate was significantly elevated (from 74 +/- 3 to 92 +/- 4 beats x min(-1); P < 0.001) during bolus sodium nitroprusside-induced reductions in blood pressure, and significantly reduced (from 92 +/- 4 to 68 +/- 4 beats x min(-1); P < 0.001) during bolus phenylephrine-induced elevations in blood pressure, thereby demonstrating normal baroreflex function in these subjects. 4. Neither SSNA nor sweat rate was altered by rapid (bolus infusion) or sustained (steady-state infusion) changes in blood pressure regardless of the thermal condition. 5. These data suggest that SSNA and sweat rate are not modulated by arterial baroreflexes in normothermic or moderately heated individuals.

Clinical Trial↗

Fractal fluctuations in cardiac time series

Human heart rate, controlled by complex feedback mechanisms, is a vital index of systematic circulation. However, it has been shown that beat-to-beat values of heart rate fluctuate continually over a wide range of time scales. Herein we use the relative dispersion, the ratio of the standard deviation to the mean, to show, by systematically aggregating the data, that the correlation in the beat-to-beat cardiac time series is a modulated inverse power law. This scaling property indicates the existence of long-time memory in the underlying cardiac control process and supports the conclusion that heart rate variability is a temporal fractal. We argue that the cardiac control system has allometric properties that enable it to respond to a dynamical environment through scaling.

NASA Discipline Cardiopulmonary↗

Effects of 12 days exposure to simulated microgravity on central circulatory hemodynamics in the rhesus monkey

Central circulatory hemodynamic responses were measured before and during the initial 9 days of a 12-day 10 degrees head-down tilt (HDT) in 4 flight-sized juvenile rhesus monkeys who were surgically instrumented with a variety of intrathoracic catheters and blood flow sensors to assess the effects of simulated microgravity on central circulatory hemodynamics. Each subject underwent measurements of aortic and left ventricular pressures, and aortic flow before and during HDT as well as during a passive head-up postural test before and after HDT. Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure were measured, and dP/dt and left ventricular elastance was calculated from hemodynamic measurements. The postural test consisted of 5 min of supine baseline control followed by 5 minutes of 90 degrees upright tilt (HUT). Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure showed no consistent alterations during HDT. Left ventricular elastance was reduced in all animals throughout HDT, indicating that cardiac compliance was increased. HDT did not consistently alter left ventricular +dP/dt, indicating no change in cardiac contractility. Heart rate during the post-HDT HUT postural test was elevated compared to pre-HDT while post-HDT cardiac output was decreased by 52% as a result of a 54% reduction in stroke volume throughout HUT. Results from this study using an instrumented rhesus monkey suggest that exposure to microgravity may increase ventricular compliance without alternating cardiac contractility. Our project supported the notion that an invasively-instrumented animal model should be viable for use in spaceflight cardiovascular experiments to assess potential changes in myocardial function and cardiac compliance.

NASA Discipline Cardiopulmonary↗

Nonlinear dynamics in cardiac conduction

Electrical conduction in the heart shows many phenomena familiar from nonlinear dynamics. Among these phenomena are multiple basins of attraction, phase locking, and perhaps period-doubling bifurcations and chaos. We describe a simple cellular-automation model of electrical conduction which simulates normal conduction patterns in the heart as well as a wide range of disturbances of heart rhythm. In addition, we review the application of percolation theory to the analysis of the development of complex, self-sustaining conduction patterns.

NASA Discipline Cardiopulmonary↗

Physiological basis for human autonomic rhythms

Oscillations of arterial pressures, heart periods, and muscle sympathetic nerve activity have been studied intensively in recent years to explore otherwise obscure human neurophysiological mechanisms. The best-studied rhythms are those occurring at breathing frequencies. Published evidence indicates that respiratory fluctuations of muscle sympathetic nerve activity and electrocardiographic R-R intervals result primarily from the action of a central 'gate' that opens during expiration and closes during inspiration. Parallel respiratory fluctuations of arterial pressures and R-R intervals are thought to be secondary to arterial baroreflex physiology: changes in systolic pressure provoke changes in the R-R interval. However, growing evidence suggests that these parallel oscillations result from the influence of respiration on sympathetic and vagal-cardiac motoneurones rather than from baroreflex physiology. There is a rapidly growing literature on the use of mathematical models of low- and high-frequency (respiratory) R-R interval fluctuations in characterizing instantaneous 'sympathovagal balance'. The case for this approach is based primarily on measurements made with patients in upright tilt. However, the strong linear relation between such measures as the ratio of low- to high-frequency R-R interval oscillations and the angle of the tilt reflects exclusively the reductions of the vagal (high-frequency) component. As the sympathetic component does not change in tilt, the low- to high-frequency R-R interval ratio provides no proof that sympathetic activity increases. Moreover, the validity of extrapolating from measurements performed during upright tilt to measurements during supine rest has not been established. Nonetheless, it is clear that measures of heart rate variability provide important prognostic information in patients with cardiovascular diseases. It is not known whether reduced heart rate variability is merely a marker for the severity of disease or a measurement that identifies functional reflex abnormalities contributing to terminal dysrhythmias.

Review, Tutorial↗

Sympathetic adaptations to one-legged training

The purpose of the present study was to determine the effect of leg exercise training on sympathetic nerve responses at rest and during dynamic exercise. Six men were trained by using high-intensity interval and prolonged continuous one-legged cycling 4 day/wk, 40 min/day, for 6 wk. Heart rate, mean arterial pressure (MAP), and muscle sympathetic nerve activity (MSNA; peroneal nerve) were measured during 3 min of upright dynamic one-legged knee extensions at 40 W before and after training. After training, peak oxygen uptake in the trained leg increased 19 +/- 2% (P < 0.01). At rest, heart rate decreased from 77 +/- 3 to 71 +/- 6 beats/min (P < 0.01) with no significant changes in MAP (91 +/- 7 to 91 +/- 11 mmHg) and MSNA (29 +/- 3 to 28 +/- 1 bursts/min). During exercise, both heart rate and MAP were lower after training (108 +/- 5 to 96 +/- 5 beats/min and 132 +/- 8 to 119 +/- 4 mmHg, respectively, during the third minute of exercise; P < 0.01). MSNA decreased similarly from rest during the first 2 min of exercise both before and after training. However, MSNA was significantly less during the third minute of exercise after training (32 +/- 2 to 22 +/- 3 bursts/min; P < 0.01). This training effect on MSNA remained when MSNA was expressed as bursts per 100 heartbeats. Responses to exercise in five untrained control subjects were not different at 0 and 6 wk. These results demonstrate that exercise training prolongs the decrease in MSNA during upright leg exercise and indicates that attenuation of MSNA to exercise reported with forearm training also occurs with leg training.

Non-NASA Center↗

System identification of closed-loop cardiovascular control mechanisms: diabetic autonomic neuropathy

We applied cardiovascular system identification (CSI) to characterize closed-loop cardiovascular regulation in patients with diabetic autonomic neuropathy (DAN). The CSI method quantitatively analyzes beat-to-beat fluctuations in noninvasively measured heart rate, arterial blood pressure (ABP), and instantaneous lung volume (ILV) to characterize four physiological coupling mechanisms, two of which are autonomically mediated (the heart rate baroreflex and the coupling of respiration, measured in terms of ILV, to heart rate) and two of which are mechanically mediated (the coupling of ventricular contraction to the generation of the ABP wavelet and the coupling of respiration to ABP). We studied 37 control and 60 diabetic subjects who were classified as having minimal, moderate, or severe DAN on the basis of standard autonomic tests. The autonomically mediated couplings progressively decreased with increasing severity of DAN, whereas the mechanically mediated couplings were essentially unchanged. CSI identified differences between the minimal DAN and control groups, which were indistinguishable based on the standard autonomic tests. CSI may provide a powerful tool for assessing DAN.

Non-NASA Center↗

Electrical alternans during rest and exercise as predictors of vulnerability to ventricular arrhythmias

This investigation was performed to evaluate the feasibility of detecting repolarization alternans with the heart rate elevated with a bicycle exercise protocol. Sensitive spectral signal-processing techniques are able to detect beat-to-beat alternation of the amplitude of the T wave, which is not visible on standard electrocardiogram. Previous animal and human investigations using atrial or ventricular pacing have demonstrated that T-wave alternans is a marker of vulnerability to ventricular arrhythmias. Using a spectral analysis technique incorporating noise reduction signal-processing software, we evaluated electrical alternans at rest and with the heart rate elevated during a bicycle exercise protocol. In this study we defined optimal criteria for electrical alternans to separate patients from those without inducible arrhythmias. Alternans and signal-averaged electrocardiographic results were compared with the results of vulnerability to ventricular arrhythmias as defined by induction of sustained ventricular tachycardia or fibrillation at electrophysiologic evaluation. In 27 patients alternans recorded at rest and with exercise had a sensitivity of 89%, specificity of 75%, and overall clinical accuracy of 80% (p <0.003). In this patient population the signal-averaged electrocardiogram was not a significant predictor of arrhythmia vulnerability. This is the first study to report that repolarization alternans can be detected with heart rate elevated with a bicycle exercise protocol. Alternans measured using this technique is an accurate predictor of arrhythmia inducibility.

Clinical Trial↗

Comparison of cardiovascular function during the early hours of bed rest and space flight

This paper reviews the cardiovascular responses of six healthy male subjects to 6 hours in a 5 degrees head-down bed rest model of weightlessness, and compares these responses to those obtained when subjects were positioned in head-up tilts of 10 degrees, 20 degrees, and 42 degrees, simulating 1/6, 1/3, and 2/3 G, respectively. Thoracic fluid index, cardiac output, stroke volume, and peak flow were measured using impedance cardiography. Cardiac dimensions and volumes were determined from two-dimensional guided M-mode echocardiograms in the left lateral decubitus position at 0, 2, 4, and 6 hours. Cardiovascular response to a stand test were compared before and after bed rest. The impedance values were related to tilt angle for the first 2 hours of tilt; however, after 3 hours, at all four angles, values began to converge, indicating that cardiovascular homeostatic mechanisms seek a common adapted state, regardless of effective gravity level (tilt angle) up to 2/3 G. Echocardiography revealed that left ventricular end-diastolic and end-systolic volume, stroke volume, ejection fraction, heart rate, and cardiac output had returned to control values by hour 6 for all tilt angles. The lack of a significant immediate change in left ventricular end-diastolic volume, despite decrements in stroke volume (P < .05) and heart rate (not significant), indicates that multiple factors may play a role in the adaptation to simulated hypogravity. The echocardiography data indicated that no angle of tilt, whether head-down or head-up for 4 to 6 hours, mimicked exactly the changes in cardiovascular function recorded after 4 to 6 hours of space flight. Changes in left ventricular end-diastolic volume during space flight and tilt may be similar, but follow a different time course. Nevertheless, head-down tilt at 5 degrees for 6 hours mimics some (stroke volume, systolic and diastolic blood pressure, mean arterial blood pressure, and total resistance), but not all, of the changes occurring in an equivalent time of space flight. The magnitude of the change in the mean heart rate response to standing was greater after six hours of tilt at -5 degrees or 10 degrees. Thus, results from the stand test after 6 hours of bed rest at -5 degrees and 10 degrees, but not at 20 degrees or 42 degrees, are similar to those obtained after space flight.

Space Flight↗

Override of spontaneous respiratory pattern generator reduces cardiovascular parasympathetic influence

We investigated the effects of voluntary control of breathing on autonomic function in cardiovascular regulation. Variability in heart rate was compared between 5 min of spontaneous and controlled breathing. During controlled breathing, for 5 min, subjects voluntarily reproduced their own spontaneous breathing pattern (both rate and volume on a breath-by-breath basis). With the use of this experimental design, we could unmask the effects of voluntary override of the spontaneous respiratory pattern generator on autonomic function in cardiovascular regulation without the confounding effects of altered respiratory pattern. Results from 10 subjects showed that during voluntary control of breathing, mean values of heart rate and blood pressure increased, whereas fractal and spectral powers in heart rate in the respiratory frequency region decreased. End-tidal PCO2 was similar during spontaneous and controlled breathing. These results indicate that the act of voluntary control of breathing decreases the influence of the vagal component, which is the principal parasympathetic influence in cardiovascular regulation.

NASA Discipline Cardiopulmonary↗

Chapter 6: Evaluation of Cardiothermal Model Prediction of Simulated Lunar Extravehicular Activity

Fewer than 20 extravehicular activities were completed during the Apollo program. The lunar environment has consistent unknowns to address particularly that of suited performance in partial gravity. The moon has altered gravity that is 1/6th that of Earth’s. This study is focused to investigate validation of the regression techniques identified in subsequent chapters and look to improve predictive outcomes during simulated lunar EVA tasks. Heart rate predictions of metabolic energy expenditure are investigated to predict workload throughout simulated lunar EVA conducted in the active response gravity offload system (ARGOS) with in the NASA Mark III space suit. Heart rate variability metrics are utilized to identify periods of high workload. Continually, the lunar offload capacity is further characterized to aid in improving the cardiothermal prediction models including predictions of core temperature, skin temperature and heat storage using heart rate, metabolic rates and suit thermal data during the simulated EVA. The outcome of this model provides an application for future use in contingency predictions of energy expenditure during Lunar EVAs and provide a suite of instrumentation to predict workload during training scenarios.

Simulated EVA↗

Altered Cardiac Energetics and Mitochondrial Dysfunction in Hypertrophic Cardiomyopathy

Background: Hypertrophic cardiomyopathy (HCM) is a complex disease partly explained by the effects of individual gene variants on sarcomeric protein biomechanics. At the cellular level, HCM mutations most commonly enhance force production, leading to higher energy demands. Despite significant advances in elucidating sarcomeric structure–function relationships, there is still much to be learned about the mechanisms that link altered cardiac energetics to HCM phenotypes. Here, we test the hypothesis that changes in cardiac energetics represent a common pathophysiologic pathway in HCM. Methods: We performed a comprehensive multiomics profile of the molecular (transcripts, metabolites, and complex lipids), ultrastructural, and functional components of HCM energetics using myocardial samples from 27 HCM patients and 13 normal controls (donor hearts). Results: Integrated omics analysis revealed alterations in a wide array of biochemical pathways with major dysregulation in fatty acid metabolism, reduction of acylcarnitines, and accumulation of free fatty acids. HCM hearts showed evidence of global energetic decompensation manifested by a decrease in high energy phosphate metabolites (ATP, ADP, and phosphocreatine) and a reduction in mitochondrial genes involved in creatine kinase and ATP synthesis. Accompanying these metabolic derangements, electron microscopy showed an increased fraction of severely damaged mitochondria with reduced cristae density, coinciding with reduced citrate synthase activity and mitochondrial oxidative respiration. These mitochondrial abnormalities were associated with elevated reactive oxygen species and reduced antioxidant defenses. However, despite significant mitochondrial injury, HCM hearts failed to upregulate mitophagic clearance. Conclusions: Overall, our findings suggest that perturbed metabolic signaling and mitochondrial dysfunction are common pathogenic mechanisms in patients with HCM. These results highlight potential new drug targets for attenuation of the clinical disease through improving metabolic function and reducing mitochondrial injury.

60 APPLIED LIFE SCIENCES↗

Pharmacologic or genetic interference with atrogene signaling protects against glucocorticoid-induced musculoskeletal and cardiac disease

Despite their beneficial actions as immunosuppressants, glucocorticoids (GC) have devastating effects on the musculoskeletal and cardiac systems, as long-term treated patients exhibit high incidence of falls, bone fractures, and cardiovascular events. Herein, we show that GC upregulate simultaneously in bone, skeletal muscle, and the heart the expression of E3 ubiquitin ligases (atrogenes), known to stimulate the proteasomal degradation of proteins. Activation of vitamin D receptor (VDR) signaling with the VDR ligands calcitriol or eldecalcitol prevented GC-induced atrogene upregulation in vivo and ex vivo in bone/muscle organ cultures and preserved tissue structure/mass and function of the 3 tissues in vivo. Direct pharmacologic inhibition of the proteasome with carfilzomib also conferred musculoskeletal protection. Genetic loss of the atrogene MuRF1-mediated protein ubiquitination in ΔRING mice afforded temporary or sustained protection from GC excess in bone or skeletal and heart muscle. We concluded that the atrogene pathway downstream of MuRF1 underlies GC action in bone, muscle, and the heart, and it can be pharmacologically or genetically targeted to confer protection against the damaging actions of GC simultaneously in the 3 tissues.

Research & Experimental Medicine↗

Design and execution of a verification, validation, and uncertainty quantification plan for a numerical model of left ventricular flow after LVAD implantation

Left ventricular assist devices (LVADs) are implantable pumps that act as a life support therapy for patients with severe heart failure. Despite improving the survival rate, LVAD therapy can carry major complications. Particularly, the flow distortion introduced by the LVAD in the left ventricle (LV) may induce thrombus formation. While previous works have used numerical models to study the impact of multiple variables in the intra-LV stagnation regions, a comprehensive validation analysis has never been executed. The main goal of this work is to present a model of the LV-LVAD system and to design and follow a verification, validation and uncertainty quantification (VVUQ) plan based on the ASME V&V40 and V&V20 standards to ensure credible predictions. The experiment used to validate the simulation is the SDSU cardiac simulator, a bench mock-up of the cardiovascular system that allows mimicking multiple operation conditions for the heart-LVAD system. The numerical model is based on Alya, the BSC’s in-house platform for numerical modelling. Alya solves the Navier-Stokes equation with an Arbitrary Lagrangian-Eulerian (ALE) formulation in a deformable ventricle and includes pressure-driven valves, a 0D Windkessel model for the arterial output and a LVAD boundary condition modeled through a dynamic pressure-flow performance curve. The designed VVUQ plan involves: (a) a risk analysis and the associated credibility goals; (b) a verification stage to ensure correctness in the numerical solution procedure; (c) a sensitivity analysis to quantify the impact of the inputs on the four quantities of interest (QoIs) (average aortic root flow $Q^{avg}_{Ao}$, maximum aortic root flow $Q^{max}_{Ao}$, average LVAD flow $Q^{avg}_{VAD}$, and maximum LVAD flow $Q^{max}_{VAD}$; (d) an uncertainty quantification using six validation experiments that include extreme operating conditions. Numerical code verification tests ensured correctness of the solution procedure and numerical calculation verification showed a grid convergence index (GCI)95% <3.3%. The total Sobol indices obtained during the sensitivity analysis demonstrated that the ejection fraction, the heart rate, and the pump performance curve coefficients are the most impactful inputs for the analysed QoIs. The Minkowski norm is used as validation metric for the uncertainty quantification. It shows that the midpoint cases have more accurate results when compared to the extreme cases. The total computational cost of the simulations was above 100 [core-years] executed in around three weeks time span in Marenostrum IV supercomputer. This work details a novel numerical model for the LV-LVAD system, that is supported by the design and execution of a VVUQ plan created following recognised international standards. We present a methodology demonstrating that stringent VVUQ according to ASME standards is feasible but computationally expensive.

59 BASIC BIOLOGICAL SCIENCES↗

Improving the performance of medical imaging applications using SYCL

As opposed to the Open Computing Language (OpenCL) programming model, in which host and device codes are generally written in different programming languages, SYCL can combine host and device codes for an application in a type-safe way to improve development productivity and performance portability. Hence, this report shows the experimental results of applying the SYCL programming model to medical imaging applications for a study on performance portability and programming productivity between OpenCL and SYCL. Rodinia is a widely used open-source benchmark suite for heterogeneous computing. We choose two medical imaging applications (Heart Wall and Particle Filter) in the benchmark suite, migrate the OpenCL implementations of the applications to the SYCL implementations, and evaluate their performance and productivity on Intel® microprocessors that contain a central processing unit (CPU) and an integrated graphics processing unit (GPU). The maturing SYCL compilers, which are based on a conformant implementation of the SYCL 1.2.1 Khronos specification, have been actively optimized for Intel® computing platforms. The experimental results are promising in terms of the raw performance and productivity. Although the SYCL implementation of the Heart Wall application does not execute successfully on a CPU, the SYCL implementations of the application can achieve comparable or better performance than the OpenCL implementation on Intel® integrated GPUs. For the Particle Filter application, the performance difference between the SYCL and OpenCL implementations is comparable on the GPUs for most cases, but the SYCL implementations are on average 4X faster than the OpenCL implementations on Intel® Xeon® CPUs. For programming productivity, we arguably use lines of code as a way to measure programming productivity in software. The SYCL programs reduce the lines of code of the OpenCL programs by 52% and 38% for the Heart Wall and Particle Filter, respectively. The results indicate that SYCL is a promising programming model for heterogeneous computing with the maturing compilers. We organize the remainder of the report as follows. Section II introduces the SYCL programming model, compares the major differences between an OpenCL program and a SYCL program, and describes the characteristics of the two applications. Section III describes the SYCL programming model in more details, and shows the SYCL implementation of a kernel function in the Particle Filter application as an example. In Section IV, we evaluate the performance of the applications on the CPUs and GPUs. Section V concludes the report.

59 BASIC BIOLOGICAL SCIENCES↗

Characterizing Hydraulic Fracture Propagation Before Fracture Hits

Estimating the distance from hydraulic fracture tip to monitor well can be very useful for fracture characterization, well spacing optimization, and preventing parent-child well interference. Heart-shape signal is referred to as the extensional precursor of fracture hit recorded by cross-well strain measurements and can be served as a vital tool to make such estimation. This study incorporates the 3D Displacement Discontinuity Method to understand the impact of fracture geometry and monitor well offset on the heart-shape signal’s characteristics. Results from numerical simulation and analytical solutions reveal a strong linear correlation between the spatial extent of heart shape signal and fracture tip distance. This relationship was further developed to predict tip distance using field data from the Hydraulic Fracture Test Site 2. A reasonable approximation result from field data further validates the methodology. In addition, it is worth noting that the estimation accuracy depends on the ratio between fracture dimension and tip distance. The findings of this study offer a novel approach for real-time monitoring and characterizing hydraulic fracture propagation, which can be further used for well spacing optimization in unconventional and Enhanced Geothermal System reservoir development, as well as cap rock integrity monitoring for carbon sequestration projects.

Jin, Ge↗

EMD-57033 Augments the Contractility in Porcine Myocardium by Promoting the Activation of Myosin in Thick Filaments

Sufficient cardiac contractility is necessary to ensure the sufficient cardiac output to provide an adequate end-organ perfusion. Inadequate cardiac output and the diminished perfusion of vital organs from depressed myocardium contractility is a hallmark end-stage of heart failure. There are no available therapeutics that directly target contractile proteins to improve the myocardium contractility and reduce mortality. The purpose of this study is to present a proof of concept to aid in the development of muscle activators (myotropes) for augmenting the contractility in clinical heart failure. Here we use a combination of cardiomyocyte mechanics, the biochemical quantification of the ATP turnover, and small angle X-ray diffraction on a permeabilized porcine myocardium to study the mechanisms of EMD-57033 (EMD) for activating myosin. We show that EMD increases the contractility in a porcine myocardium at submaximal and systolic calcium concentrations. Biochemical assays show that EMD decreases the proportion of myosin heads in the energy sparing super-relaxed (SRX) state under relaxing conditions, which are less likely to interact with actin during contraction. Structural assays show that EMD moves the myosin heads in relaxed muscles from a structurally ordered state close to the thick filament backbone, to a disordered state closer to the actin filament, while simultaneously inducing structural changes in the troponin complex on the actin filament. The dual effects of EMD on activating myosin heads and the troponin complex provides a proof of concept for the use of small molecule muscle activators for augmenting the contractility in heart failure.