Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heterogeneous”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Enhancement of output power in spin torque nano-oscillator using heterogeneous layer

The article mainly focuses on the enrichment of the output power obtained from Spin torque nano-oscillator by introducing the heterogeneous structure in multilayer nanopillar device. Here we devised two homogeneous and two heterogeneous devices having NiFe and Co materials. The dynamics of the devices are governed by a famous Landu- Lifshitz -Gilbert-Solencskwei (LLGS) equation which can be solved numerically using embedded RK-4 procedure. The current density and the external magnetic field for four devices are taken as 5×l0{sup 11}A/m{sup 2} and 6×l0{sup −3} A/m respectively. The applied dc current is converted into spin polarized dc current while it passes through pinned layer. The generated spin polarized dc currents produces spin transfer torque with the free layer magnetization via spacer. Thus the magnetization of the free layer gets a sustained oscillation. The results obtained from the heterogeneous STNOs are really fascinating. The frequency of the NiFe/ Cu/NiFe and Co/Cu/NiFe devices have the same frequency but there is a tremendous change in the output power which is exactly twice that the NiFe/Cu/NiFe device. The similar behaviour is also obtained from Co/Cu/Co and NiFe/Cu/Co devices. The line width and the Q-factor of the output microwave signal are also computed. Among the four devices, the NiFe/Cu/Co heterogeneous device has low linewidth (408 MHz) and high Q-factor (4.77).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phenotype heterogeneity in cancer cell populations

Phenotype heterogeneity in cancer cell populations, be it of genetic, epigenetic or stochastic origin, has been identified as a main source of resistance to drug treatments and a major source of therapeutic failures in cancers. The molecular mechanisms of drug resistance are partly understood at the single cell level (e.g., overexpression of ABC transporters or of detoxication enzymes), but poorly predictable in tumours, where they are hypothesised to rely on heterogeneity at the cell population scale, which is thus the right level to describe cancer growth and optimise its control by therapeutic strategies in the clinic. We review a few results from the biological literature on the subject, and from mathematical models that have been published to predict and control evolution towards drug resistance in cancer cell populations. We propose, based on the latter, optimisation strategies of combined treatments to limit emergence of drug resistance to cytotoxic drugs in cancer cell populations, in the monoclonal situation, which limited as it is still retains consistent features of cell population heterogeneity. The polyclonal situation, that may be understood as “bet hedging” of the tumour, thus protecting itself from different sources of drug insults, may lie beyond such strategies and will need further developments. In the monoclonal situation, we have designed an optimised therapeutic strategy relying on a scheduled combination of cytotoxic and cytostatic treatments that can be adapted to different situations of cancer treatments. Finally, we review arguments for biological theoretical frameworks proposed at different time and development scales, the so-called atavistic model (diachronic view relying on Darwinian genotype selection in the coursof billions of years) and the Waddington-like epigenetic landscape endowed with evolutionary quasi-potential (synchronic view relying on Lamarckian phenotype instruction of a given genome by reversible mechanisms), to represent evolution towards heterogeneity, possibly polyclonal, in cancer cell populations and propose innovative directions for therapeutic strategies based on such frameworks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlating structural and photochemical heterogeneity in cyanobacteriochrome NpR6012g4

Phytochrome photoreceptors control plant growth, development, and the shade avoidance response that limits crop yield in high-density agricultural plantings. Cyanobacteriochromes (CBCRs) are distantly related photosensory proteins that control cyanobacterial metabolism and behavior in response to light. Photoreceptors in both families reversibly photoconvert between two photostates via photoisomerization of linear tetrapyrrole (bilin) chromophores. Spectroscopic and biochemical reprorts have demonstrated heterogeneity in both photostates, but the structural basis for such heterogeneity remains unclear. We discuss solution NMR structures for both photostates of the red/green CBCR NpR6012g4 from Nostoc punctiforme . In addition to identifying structural changes accompanying photoconversion, these structures reveal structural heterogeneity for residues Trp655 and Asp657 in the red-absorbing NpR6012g4 dark state, yielding two distinct environments for the phycocyanobilin chromophore. We use site-directed mutagenesis and fluorescence and absorbance spectroscopy to assign an orange-absorbing population in the NpR6012g4 dark state to the minority configuration for Asp657. This population does not undergo full, productive photoconversion, as shown by time-resolved spectroscopy and absorption spectroscopy at cryogenic temperature. Our research thus elucidate the spectral and photochemical consequences of structural heterogeneity in a member of the phytochrome superfamily, insights that should inform efforts to improve photochemical or fluorescence quantum yields in the phytochrome superfamily.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Particle-to-particle heterogeneous nature of coals. A case of large coal particles

In the present paper, the results of investigation of the heterogeneous nature of coals are given. Microscopic observations of coals of different rank and mineral matter content were performed. The content of minerals and macerals and the size of their grains were determined in the coal samples. Two samples of lignite rich in minerals were analyzed in detail by measuring the ash content for each particle and batches containing numerous (100) coal particles. The additional analyses were performed with the particles before and after sink-float separation. The obtained results showed an increase of heterogeneity with mineral matter content. The statistical analysis showed that many particles should be used for an experiment for obtaining reliable data with a desired level of certainty. In the case of batch experiments with 5 g Kolubara B coal (about 100 particles, size 4.76-7.0 mm), the experiment should be repeated at least 7, 19, and 100 times in order to obtain a mean value in the confidence intervals 5.0%, 2.5%, and 1.0%, respectively, for a 95% probability (if sample heterogeneity is the only cause for variations in results). However, regardless of increase of reproducibility and repeatability of obtained results, a large amount of samples and numerous repetitions of experiments cannot exclude differences in experimental results between homogenous and heterogeneous samples.

01 COAL, LIGNITE, AND PEAT↗

Anomalous transport on regular fracture networks: Impact of conductivity heterogeneity and mixing at fracture intersections

We investigate here transport on regular fracture networks that are characterized by heterogeneity in hydraulic conductivity. We discuss the impact of conductivity heterogeneity and mixing within fracture intersections on particle spreading. We show the emergence of non-Fickian transport due to the interplay between the network conductivity heterogeneity and the degree of mixing at nodes. Specifically, lack of mixing at fracture intersections leads to subdiffusive scaling of transverse spreading but has negligible impact on longitudinal spreading. An increase in network conductivity heterogeneity enhances both longitudinal and transverse spreading and leads to non-Fickian transport in longitudinal direction. Based on the observed Lagrangian velocity statistics, we develop an effective stochastic model that incorporates the interplay between Lagrangian velocity correlation and velocity distribution. The model is parameterized with a few physical parameters and is able to capture the full particle transition dynamics.

58 GEOSCIENCES↗

IRIS-DMEM: Efficient Memory Management for Heterogeneous Computing

This paper proposes an efficient data memory management approach for the Intelligent RuntIme System (IRIS) heterogeneous computing framework along with new data transfer policies. IRIS provides a task-based programming model for extreme heterogeneous computing (e.g., CPU, GPU, DSP, FPGA) with support for today's most important programming languages (e.g., OpenMP, OpenCL, CUDA, HIP, OpenACC). However, the IRIS framework either forces the programmer to introduce data transfer commands for each task or relies on suboptimal memory management for automatic and transparent data transfers. The work described here extends IRIS with novel heterogeneous memory handling and introduces novel data transfer policies by employing the Distributed data MEMory handler (DMEM) for efficient and optimal movement of data among the various computing resources. The proposed approach achieves performance gains of up to 7× for tiled LU factorization and tiled DGEMM (i.e., matrix multiplication) benchmarks. Moreover, this approach also reduces data transfers by up to 71% when compared to previous IRIS heterogeneous memory management handlers. This work compares the performance results of the IRIS framework's novel DMEM with the StarPU runtime and MAGMA math library for GPUs. Experiments show a performance gain of up to 1.95× over StarPU and 2.1× over MAGMA.

Miniskar, Narasinga Rao↗

SharP: Towards Programming Extreme-Scale Systems with Hierarchical Heterogeneous Memory

The pre-exascale systems are expected to have a significant amount of hierarchical and heterogeneous on-node memory, and this trend of system architecture in extreme-scale systems is expected to continue into the exascale era. Along with hierarchical-heterogeneous memory, the system typically has a high-performing network and a compute accelerator. This system architecture is not only effective for running traditional High Performance Computing (HPC) applications (Big-Compute), but also running data-intensive HPC applications and Big-Data applications. As a consequence, there is a growing desire to have a single system serve the needs of both Big-Compute and Big-Data applications. Though the system architecture supports the convergence of the Big-Compute and Big-Data, the programming models have yet to evolve to support either hierarchical-heterogeneous memory systems or the convergence. In this work, we propose and develop the programming abstraction called SHARed data-structure centric Programming abstraction (SharP) to address both of these goals, i.e., provide (1) a simple, usable, and portable abstraction for hierarchical-heterogeneous memory and (2) a unified programming abstraction for Big-Compute and Big-Data applications. To evaluate SharP, we implement a Stencil benchmark using SharP, port QMCPack, a petascale-capable application, and adapt Memcached ecosystem, a popular Big-Data framework, to use SharP, and quantify the performance and productivity advantages. Additionally, we demonstrate the simplicity of using SharP on different memories including DRAM, High-bandwidth Memory (HBM), and non-volatile random access memory (NVRAM).

97 MATHEMATICS AND COMPUTING↗

Time Utility Functions for Modeling and Evaluating Resource Allocations in a Heterogeneous Computing System

This study considers a heterogeneous computing system and corresponding workload being investigated by the Extreme Scale Systems Center (ESSC) at Oak Ridge National Laboratory (ORNL). The ESSC is part of a collaborative effort between the Department of Energy (DOE) and the Department of Defense (DoD) to deliver research, tools, software, and technologies that can be integrated, deployed, and used in both DOE and DoD environments. The heterogeneous system and workload described here are representative of a prototypical computing environment being studied as part of this collaboration. Each task can exhibit a time-varying importance or utility to the overall enterprise. In this system, an arriving task has an associated priority and precedence. The priority is used to describe the importance of a task, and precedence is used to describe how soon the task must be executed. These two metrics are combined to create a utility function curve that indicates how valuable it is for the system to complete a task at any given moment. This research focuses on using time-utility functions to generate a metric that can be used to compare the performance of different resource schedulers in a heterogeneous computing system. The contributions of this paper are: (a) a mathematical model of a heterogeneous computing system where tasks arrive dynamically and need to be assigned based on their priority, precedence, utility characteristic class, and task execution type, (b) the use of priority and precedence to generate time-utility functions that describe the value a task has at any given time, (c) the derivation of a metric based on the total utility gained from completing tasks to measure the performance of the computing environment, and (d) a comparison of the performance of resource allocation heuristics in this environment.

99 GENERAL AND MISCELLANEOUS↗

Designing a unified programming model for heterogeneous machines

While high-efficiency machines are increasingly embracing heterogeneous architectures and massive multithreading, contemporary mainstream programming languages reflect a mental model in which processing elements are homogeneous, concurrency is limited, and memory is a flat undifferentiated pool of storage. Moreover, the current state of the art in programming heterogeneous machines tends towards using separate programming models, such as OpenMP and CUDA, for different portions of the machine. Both of these factors make programming emerging heterogeneous machines unnecessarily difficult. We describe the design of the Phalanx programming model, which seeks to provide a unified programming model for heterogeneous machines. It provides constructs for bulk parallelism, synchronization, and data placement which operate across the entire machine. Our prototype implementation is able to launch and coordinate work on both CPU and GPU processors within a single node, and by leveraging the GASNet runtime, is able to run across all the nodes of a distributed-memory machine.

Garland, Michael↗

Pursuing sources of heterogeneity in modeling clustered population

Abstract Researchers often have to deal with heterogeneous population with mixed regression relationships, increasingly so in the era of data explosion. In such problems, when there are many candidate predictors, it is not only of interest to identify the predictors that are associated with the outcome, but also to distinguish the true sources of heterogeneity , that is, to identify the predictors that have different effects among the clusters and thus are the true contributors to the formation of the clusters. We clarify the concepts of the source of heterogeneity that account for potential scale differences of the clusters and propose a regularized finite mixture effects regression to achieve heterogeneity pursuit and feature selection simultaneously. We develop an efficient algorithm and show that our approach can achieve both estimation and selection consistency. Simulation studies further demonstrate the effectiveness of our method under various practical scenarios. Three applications are presented, namely, an imaging genetics study for linking genetic factors and brain neuroimaging traits in Alzheimer's disease, a public health study for exploring the association between suicide risk among adolescents and their school district characteristics, and a sport analytics study for understanding how the salary levels of baseball players are associated with their performance and contractual status.

Li, Yan↗

The origin of the heterogeneous distribution of bismuth in aluminosilicate laser glasses

Abstract As one kind of novel and burgeoning laser materials, bismuth‐doped silicate glasses have aroused increasing attention for the super broadband near‐infrared (NIR) emission. However, the large optical scattering loss, resulting from optical heterogeneity in glass color and refractive index, limits their further applications in telecommunication system. Thus, it is urgent to uncover the essence of heterogeneity in Bi‐doped silicate glasses and subsequently improve glass optical performance. It will give us some hint to homogenize the glass component and Bi active centers so as to boost the development of Bi‐based glass materials. Here, taking 1 typical Bi‐doped calcium aluminosilicate glass as an example, we revealed the origin of the optical heterogeneities in glass color and refractive index through the NIR emission spectra, electron probe microanalyzer (EPMA) of elements and X‐ray photoelectron spectroscopy (XPS) of Bi 4f 5/2 , Bi 4f 7/2 , and Al 2p. The inhomogeneous distribution of Bi and aluminum components is responsible for the heterogeneity in this glass system. In addition, we found that tetrahedral coordinated aluminum favors the existence of Bi NIR centers, consequently resulting in enhanced Bi NIR emissions. Furthermore, based on our results and the role of Al 3+ in glass network, we demonstrate the homogenizing of glass component by finely tuning glass composition. This work will enrich the understanding of Bi‐doped laser glass and provide a guideline for the design of component‐derived Bi‐doped silicate glasses and fibers with efficient NIR emission and high optical quality.

Li, Xiaoman↗

Experimental verification of the Acuros XB and AAA dose calculation adjacent to heterogeneous media for IMRT and RapidArc of nasopharygeal carcinoma

Purpose: To compare the doses calculated by the Acuros XB (AXB) algorithm and analytical anisotropic algorithm (AAA) with experimentally measured data adjacent to and within heterogeneous medium using intensity modulated radiation therapy (IMRT) and RapidArc{sup Registered-Sign} (RA) volumetric arc therapy plans for nasopharygeal carcinoma (NPC). Methods: Two-dimensional dose distribution immediately adjacent to both air and bone inserts of a rectangular tissue equivalent phantom irradiated using IMRT and RA plans for NPC cases were measured with GafChromic{sup Registered-Sign} EBT3 films. Doses near and within the nasopharygeal (NP) region of an anthropomorphic phantom containing heterogeneous medium were also measured with thermoluminescent dosimeters (TLD) and EBT3 films. The measured data were then compared with the data calculated by AAA and AXB. For AXB, dose calculations were performed using both dose-to-medium (AXB{sub Dm}) and dose-to-water (AXB{sub Dw}) options. Furthermore, target dose differences between AAA and AXB were analyzed for the corresponding real patients. The comparison of real patient plans was performed by stratifying the targets into components of different densities, including tissue, bone, and air. Results: For the verification of planar dose distribution adjacent to air and bone using the rectangular phantom, the percentages of pixels that passed the gamma analysis with the {+-} 3%/3mm criteria were 98.7%, 99.5%, and 97.7% on the axial plane for AAA, AXB{sub Dm}, and AXB{sub Dw}, respectively, averaged over all IMRT and RA plans, while they were 97.6%, 98.2%, and 97.7%, respectively, on the coronal plane. For the verification of planar dose distribution within the NP region of the anthropomorphic phantom, the percentages of pixels that passed the gamma analysis with the {+-} 3%/3mm criteria were 95.1%, 91.3%, and 99.0% for AAA, AXB{sub Dm}, and AXB{sub Dw}, respectively, averaged over all IMRT and RA plans. Within the NP region where air and bone were present, the film measurements represented the dose close to unit density water in a heterogeneous medium, produced the best agreement with the AXB{sub Dw}. For the verification of point doses within the target using TLD in the anthropomorphic phantom, the absolute percentage deviations between the calculated and measured data when averaged over all IMRT and RA plans were 1.8%, 1.7%, and 1.8% for AAA, AXB{sub Dm} and AXB{sub Dw}, respectively. From all the verification results, no significant difference was found between the IMRT and RA plans. The target dose analysis of the real patient plans showed that the discrepancies in mean doses to the PTV component in tissue among the three dose calculation options were within 2%, but up to about 4% in the bone content, with AXB{sub Dm} giving the lowest values and AXB{sub Dw} giving the highest values. Conclusions: In general, the verification measurements demonstrated that both algorithms produced acceptable accuracy when compared to the measured data. GafChromic{sup Registered-Sign} film results indicated that AXB produced slightly better accuracy compared to AAA for dose calculation adjacent to and within the heterogeneous media. Users should be aware of the differences in calculated target doses between options AXB{sub Dm} and AXB{sub Dw}, especially in bone, for IMRT and RA in NPC cases.

60 APPLIED LIFE SCIENCES↗

SU-E-J-63: Estimating the Effects of Respiratory Motion On Dose Heterogeneity for ITV-Based Treatments

Purpose: To quantify the relationship between the amount of dose heterogeneity in a treatment plan that uses an internal target volume (ITV) to account for respiratory motion and the true amount of heterogeneity in the dose delivered to the tumor contained within that ITV. Methods: We develop a convolution-based framework for calculating dose delivered to a tumor moving inside an ITV according to a common sinusoid-based breathing model including asymmetry. We model the planned ITV dose distribution as a centrally peaked analytic function approximating the profile of clinical stereotactic body radiotherapy treatments. Expressions for the minimum and maximum dose received by the tumor are derived and evaluated for a range of clinically relevant parameters. Results of the model are validated with phantom measurements using an ion chamber array. Results: An analytic expression is presented for the maximum and minimum doses received by the tumor relative to the planned ITV dose. The tumor dose heterogeneity depends solely on the ratio of tumor size to ITV size, the peak dose in the planned ITV dose distribution, and the respiratory asymmetry parameter. Under the assumptions of this model, using a typical breathing asymmetry parameter and a dose distribution with a fixed size ITV covered by the 100% line and with a 130% hotspot, the maximum dose to the tumor varies between 113%–130%, and the minimum dose varies between 100%–116% depending on the amount of tumor motion. Conclusion: This modeling exercise demonstrates the interplay between motion and dose heterogeneity. Tumors that exhibit large amounts of respiratory motion relative to their size will receive a more homogeneous dose and a larger minimum dose than would be inferred from the ITV dose distribution. This effect is not captured in current clinical treatment planning methods unless 4D dose calculation techniques are used. This work was partially supported by a Varian Medical Systems research grant.

60 APPLIED LIFE SCIENCES↗

SU-E-T-162: Evaluation of Dose Calculation of RayStation Planning System in Heterogeneous Media

Purpose: To investigate the clinical reliability of heterogeneity-based dose algorithm using RayStation treatment planning system v.4.0. Methods: The collapsed cone dose calculations in RayStation (RaySearch, Sweden) were compared with the measurements (ion chamber and EBT2 film) and with an in-house Monte Carlo algorithm. A heterogeneous multi-layer phantom and CT images of 4 lung cancer patients were used here. The phantom, composed of multiple solid water slabs and Styrofoams, was irradiated with 6MV beams perpendicular to the layers. The MLC-defined field sizes were 5×5, 10×10, 15×15 and 20×20cm{sup 2}. The chamber was positioned at center of central solid water layer, and the films were placed at interfaces of solid water and Styrofoam. The RayStation dose and Monte Carlo dose were compared by performing absolute gamma analysis (3mm/3%): 1D gamma for PDD in the phantom and 3D gamma for patient volumes receiving dose above 10% of maximum dose. Results: The point dose differences between RayStation and ion chamber measurement were smaller than 1% for all of the field sizes. Between RayStation and film measurement, 5×5cm2 field had the maximum differences : <4mm for the penumbra and <0.3mm for the field width at all Styrofoam-and-solid-water interfaces. The absolute gamma analysis showed good agreement between RayStation and Monte Carlo. For PDD along beam axis in the phantom, the 1D gamma was 95.4, 98.6, 99.6 and 99.3% for field size 5×5, 10×10, 15×15 and 20×202 respectively. For dose comparison using patient CT images, 3D gamma was > 95% for all the patients. Conclusion: With respect to ion chamber/film measurement and Monte Carlo calculation, the collapsed cone algorithm in RayStation computed reasonable dose in both phantom and patient cases. Heterogeneity-based dose calculation of RayStation is clinically acceptable in heterogeneous media.

60 APPLIED LIFE SCIENCES↗

SU-E-T-283: Dose Perturbations Near Heterogeneity Junctions for Modulated-Scanning Protons

Purpose: To compare calculated and measured doses near heterogeneity junctions of tissue-substitute materials for modulated-scanning protons. Methods: Three heterogeneous phantoms were configured using slabs of various plastics to simulate lung, fat, soft-tissue (polystyrene), and bone with known relative linear stopping powers (RLSPs). Each phantom consisted of soft-tissue and a single heterogeneity of a 5 or 10 cm thickness of a non-soft-tissue material. CT images were loaded into a Syngo treatment planning system and each material contoured and assigned its RLSP. Planning target volumes (PTVs) were drawn such that a beam would partially traverse the heterogeneity and partially only soft-tissue. Lateral profiles were measured using EDR2 films at a minimum of six depths between the phantom surface and the depth corresponding to the beam range. Absolute doses were measured inside and distal to the PTV in all phantoms using either a parallel plate or thimble chamber. Additional dose measurements were made between two lung slabs. Results: Profiles measured by film generally agreed with calculations except for depths distal to lung and fat junctions. Measured lateral penumbras for depths at the distal junction of lung were found to be wider than calculated ones. Compared with calculated doses, measured doses in the PTVs were 5.19% and 2.51% lower for lung and fat respectively but for bone were 0.2% higher. Measured doses for depths distal to the PTV were up to 29.65% and 10.58% higher for lung and fat, respectively but 6.30% lower for bone. Conclusion: The low measured doses in the PTVs for lung and fat might be due to underestimation of lateral scattering of protons. The higher measured doses distal to the PTV for the lung and fat are a Result of a shortened calculated beam range whereas the higher dose distal to the bone junction is within uncertainties.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-J-01: Acoustic Range Verification of Proton Beams: Simulation of Heterogeneity and Clinical Proton Pulses

Purpose: Through simulation, to assess acoustic-based range verification of proton beams (protoacoustics) under clinical conditions. Methods: Pressure waves generated by the energy deposition of a 150 MeV, 8 mm FWHM pulsed pencil proton beam were numerically simulated through two Methods: 1) For a homogeneous water medium, an analytical wave-equation solution was used to calculate the time-dependent pressure measured at detector points surrounding the proton Bragg peak. 2) For heterogeneity studies, a CT tissue image was used to calculate the proton dose deposition and define the acoustic properties of the voxels through which numerical pressure wave propagation was simulated with the k-Wave matlab toolbox. The simulations were used to assess the dependence of the acoustic amplitude and range-verification accuracy on proton pulse rise time and tissue heterogeneity. Results: As the proton pulse rise time is increased from 1 to 40 µs, the amplitude of the expected acoustic emission decreases (a 60% drop distal to the Bragg peak), the central frequency of the expected signal decreases (from 45 to 6 kHz), and the accuracy of the range-verification decreases (from <1 mm to 16 mm at 5 cm distal to the Bragg peak). For a 300 nA pulse, the expected pressure range is on the order of 0.1 Pa, which is observable with commercial detectors. For the heterogeneous medium, our test case shows that pressure waves emitted by an anterior pencil beam directed into the abdomen and detected posteriorly can determine the Bragg peak range to an accuracy of <2mm for a 1 µs proton pulse. Conclusion: For proton pulses with fast rise-times, protoacoustics is a promising potential method for monitoring penetration depth through heterogeneous tissue. The loss of range-verification accuracy with increasing rise-times, however, suggests the need for comparisons to modeling to improve accuracy for slower cyclotron proton sources.

07 ISOTOPE AND RADIATION SOURCES↗

Computational Modeling of Heterogeneity of Stress, Charge, and Cyclic Damage in Composite Electrodes of Li-Ion Batteries

Charge heterogeneity is a prevalent feature in many electrochemical systems. In a commercial cathode of Li-ion batteries, the composite is hierarchically structured across multiple length scales including the sub-micron single-crystal primary-particle domains up to the macroscopic particle ensembles. The redox kinetics of charge transfer and mass transport strongly couples with mechanical stresses. This interplay catalyzes substantial heterogeneity in the charge (re)distribution, stresses, and mechanical damage in the composite electrode during charging and discharging. We assess the heterogeneous electrochemistry and mechanics in a LiNi x Mn y Co z O 2 (NMC) cathode using a fully coupled electro-chemo-mechanics model at the cell level. A microstructure-resolved model is constructed based on the synchrotron X-ray tomography data. We calculate the stress field in the composite and then quantitatively evaluate the kinetics of surface charge transfer and Li transport biased by mechanical stresses. We further model the cyclic behavior of the cell. The repetitive deformation of the active particles and the weakening of the interfacial strength cause gradual increase of the interfacial debonding. The mechanical damage impedes electron transfer, incurs more charge heterogeneity, and results in the capacity degradation in batteries over cycles.

25 ENERGY STORAGE↗

Interplay of Electrode Heterogeneity and Lithium Plating

Lateral microstructure heterogeneity in anodes is known to induce nonuniform current density, state of charge, and lithium plating. This means that such electrode heterogeneity can limit the fast charging of lithium-ion batteries. In this work, a combination of experiments and simulation is employed to understand the effect of mm scale lateral heterogeneity on cell aging. A previously developed model was extended to efficiently simulate SEI formation and Li plating for independent regions of an electrode. The model consists of three parallel regions each described under a P2D framework and with a distinct ionic resistance and possibly active material loading. The results suggest that during fast charge when the active material is uniformly distributed across the three regions, the region with the highest resistance reaches the end of life sooner than the other regions. There is also positive feedback from Li metal filling the pores near the separator interface that further accelerates lithium plating. Lastly, when there is a non-uniform active material distribution associated with the ionic resistance heterogeneity, tight competition between regions can occur, leading to less overall lithium plating and plating that is more uniform between regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗