Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Gradient Accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Cryogenic testing of the 2.1 GHz five-cell superconducting RF cavity with a photonic band gap coupler cell

We present results from cryogenic tests of the multi-cell superconducting radio frequency (SRF) cavity with a photonic band gap (PBG) coupler cell. Achieving high average beam currents is particularly desirable for future light sources and particle colliders based on SRF energy-recovery-linacs (ERLs). Beam current in ERLs is limited by the beam break-up instability, caused by parasitic higher order modes (HOMs) interacting with the beam in accelerating cavities. A PBG cell incorporated in an accelerating cavity can reduce the negative effect of HOMs by providing a frequency selective damping mechanism, thus allowing significantly higher beam currents. The multi-cell cavity was designed and fabricated of niobium. Two cryogenic (vertical) tests were conducted. The high unloaded Q-factor was demonstrated at a temperature of 4.2 K at accelerating gradients up to 3 MV/m. The measured value of the unloaded Q-factor was 1.55 × 10 8 , in agreement with prediction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical shock-enhanced self-photon acceleration

Photon accelerators can spectrally broaden laser pulses with high efficiency in moving electron density gradients driven in a rapidly ionizing plasma. When driven by a conventional laser pulse, the group velocity walk-off experienced by the accelerated photons and deterioration of the gradient from diffraction and plasma-refraction limit the extent of spectral broadening. In this work, we show that a laser pulse with a shaped space-time and transverse intensity profile overcomes these limitations by creating a guiding density pro le at a tunable velocity. Self-photon acceleration in this profile leads to dramatic spectral broadening and intensity steepening, forming an optical shock that further enhances the rate of spectral broadening. In this new regime, multi-octave spectra extending from 400nm to 60nm wavelengths, which support near-transform limited < 400 as pulses, are generated over < 100 μm of interaction length.

74 ATOMIC AND MOLECULAR PHYSICS↗

Magnetic Measurements of the First Nb 3 Sn Model Quadrupole (MQXFS) for the High-Luminosity LHC

The US LHC Accelerator Research Program (LARP) and CERN are developing high-gradient Nb 3 Sn magnets for the High Luminosity LHC interaction regions. Magnetic measurements of the first 1.5 m long, 150 mm aperture model quadrupole, MQXFS1, were performed during magnet assembly at LBNL, as well as during cryogenic testing at Fermilab’s Vertical Magnet Test Facility. This paper reports on the results of these magnetic characterization measurements, as well as on the performance of new probes developed for the tests.

43 PARTICLE ACCELERATORS↗

Compac carbon ion LINAC

The invention provides a method for accelerating protons and carbon ions up to 450 MeV/u in a very compact linac, the method comprising subjecting the particles to a radio frequency quadrupole field to accelerate the particles to at least 3 MeV/u, a drift tube linac (DTL) to an energy of 20 MeV/u, followed by a coupled DTL to 45 MeV/u and finally a high-gradient section made of CCL-type standing wave cavities or negative harmonic traveling wave cavities operating at S-band frequencies and capable of delivering voltage gradients of 40 to 60 MV/m. Focusing the accelerated particles while accelerated to higher energy is provided by appropriately placed constant field permanent magnets and electromagnetic quadrupoles. The compactness and power efficiency of the linac is enabled by using high-gradient structure in the S-band frequencies for lower energy particles than ever before. The low-intensity required for hadron therapy allows the use of small-aperture S-band structures and the operation at very high gradient compared to high-intensity machines for research. Operating with very short sub-microsecond pulses at repetition rates up to 400 Hz allows the fast and flexible beam energy and intensity tuning not provided by existing hadron therapy machines. The designed linac is capable of accelerating ions as heavy as neon to the full 450 MeV/u energy, therefore allowing fast beam switching if different ion sources are installed in the front-end of the linac.

43 PARTICLE ACCELERATORS↗

Toward Emittance Measurements at 11.7 GHz Short-Pulse High-Gradient RF Gun

A short pulse high gradient RF gun has been recently tested at Argonne Wakefield Accelerator (AWA) facility. The carried-out test showed that the 1,5-cell gun was able to inject 3 MeV, up to 100 pC bunches at room tem-perature being fed by 9 ns up to 300 MW 11.7 GHz puls-es. The cathode field was as high as about 400 MV/m. So high field is aimed to mitigate repealing Coulomb forces substantially. In accordance with simulations the emit-tance could be as low as less than 0.2 mcm. To obtain so low emittance in the experiment, the gun is assumed to be equipped with a downstream linac to be fed from the same power extractor as the gun itself. Here we report design of the RF power distribution system splitting RF power among the gun and the linac, results of low-power tests, and emittance measurement plans for upcoming new experiment at AWA.

43 PARTICLE ACCELERATORS↗

High-Gradient Wien Spin Rotators at Jefferson Lab

Nuclear physics experiments performed in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) require spin manipulation of electron beams. Two Wien spin rotators in the injector keV region are essential at CEBAF to establish longitudinal polarization at the end station target, and to flip the polarization direction by ? rad to rule out false asymmetries. In a Wien filter, the homogeneous and independent electric and magnetic fields, along with the velocity vectors of the electrons that traverse it, form a mutually orthogonal system. The magnitude of the electrostatic field, established by biasing two highly-polished electrodes, defines the desired spin angle at the target yet deviates the beam trajectory due to the Lorentz force. The beam trajectory in the Wien is then re-established by adjusting the magnetic field, induced by an electromagnet encasing the device vacuum chamber. This contribution describes the evolution design and high voltage testing of Wien filters for spin manipulation at increased beam energies in the keV injector region, required by high precision parity violation experiments like MOLLER.

Palacios Serrano, G. G.↗

High-Gradient Wien Spin Rotators at Jefferson Lab

Nuclear physics experiments performed in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) require spin manipulation of electron beams. Two Wien spin rotators in the injector keV region are essential at CEBAF to establish longitudinal polarization at the end station target, and to flip the polarization direction by ? rad to rule out false asymmetries. In a Wien filter, the homogeneous and independent electric and magnetic fields, along with the velocity vectors of the electrons that traverse it, form a mutually orthogonal system. The magnitude of the electrostatic field, established by biasing two highly-polished electrodes, defines the desired spin angle at the target yet deviates the beam trajectory due to the Lorentz force. The beam trajectory in the Wien is then re-established by adjusting the magnetic field, induced by an electromagnet encasing the device vacuum chamber. This contribution describes the evolution design and high voltage testing of Wien filters for spin manipulation at increased beam energies in the keV injector region, required by high precision parity violation experiments like MOLLER.

Palacios Serrano, G. G.↗

Superconducting DC and RF properties of ingot Niobium used in SRF cavity fabrication

Bulk niobium (Nb) has been the material of choice for the superconducting radiofrequency (SRF) cavity used in particle accelerator because of its highest transition temperature (Tc) and highest lower critical field (Hc1~ 190 mT) among the elemental type-II superconductors. The overall performance of these SRF cavities is measured by its quality factor, Q0 as a function of the accelerating gradient, Eacc. Higher Q0 for the reduction of cryogenic loss and higher Eacc for the use of high energy accelerators are desired. SRF cavities fabricated from ingot niobium have become a viable alternative to standard high-purity fine-grain Nb for the fabrication of high-performing SRF cavities with the possibility of significant cost reduction. In this contribution, we present the results on DC, low-frequency and RF measurements of Nb rods machined from ingots with different impurity concentrations, provided by CBMM, Brazil. The rods have been subjected to different treatments typically applied to SRF cavities. In addition, single-cell cavities are being fabricated from the same ingot material and initial results on one of them showed high Q0-values at 2 K up to peak surface magnetic fields of about 110 mT. Residual resistance values below 5 n have been consistently achieved on this cavity. A new induction furnace was commissioned for the heat treatment of these single-cells, which allows avoiding subsequent chemical etching of the cavity surface.

Myneni, Ganapati↗

Beryllium–tungsten graded density inner shells in double shell capsules for improved hydrodynamic stability

The outer surface of the high-Z inner shell in the double shell configuration of inertial confinement fusion experiments experiences Rayleigh–Taylor instability growth during the implosion process due to inverted density and pressure gradients between a highly compressed foam interstitial layer and the accelerating dense inner shell. Graded density layers have long been known to reduce instability growth rates. In this study, we employ high-fidelity radiation hydrodynamic simulations to demonstrate this improved stability when grading beryllium into tungsten. We first characterize the response to L-band preheat of these layers using a newly calibrated radiation drive. While graded layer capsules suffer reduced performance (here, measured as DD neutron yield from a CD foam fuel) in 1D simulations due to reduced kinetic energy coupling and reduced fuel compression, they suffer less of a performance drop when 2D instabilities are accounted for. With the improved stability of graded layers, we explore the performance of capsules with larger fuel radii and thinner shells as a preliminary study to find new designs in which graded layers produce the highest yields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-Dimensional Reconstruction of Nb 3 Sn Films by Focused Ion Beam Cross Sectional Microscopy

Niobium has been the material of choice for SRF cavities for several decades due to its formability and superconducting properties. The accelerating gradient of niobium cavities is, however, rapidly approaching a theoretical limit. To achieve higher accelerating gradients a new material is needed that can sustain high fields. Nb 3 Sn is a promising competitor with a higher superconducting transition temperature and a higher critical field than pure niobium. However, Nb 3 Sn is very brittle and cannot be formed readily into a cavity. The main method for creating Nb 3 Sn cavities is to form a Nb 3 Sn film into a niobium surface using a tin vapor-diffusion method. This technique creates a microcrystalline Nb 3 Sn thin film on the inner surface of the cavity. Tin depleted regions are known to form in the film during this process. Previous studies have analyzed these regions using transmission electron microscopy on cross-sectional lamellae prepared by focused ion beam/scanning electron microscope (FIB/SEM). This method does not provide any three-dimensional (3-D) information about the distribution of tin-deficient regions. In this study we employ a focused ion beam tomographic technique to analyze the 3-D structure of the film. Electron dispersive X-ray spectroscopy is used to image the tin concentration of the film in 3-D. Tin-deficient regions are discovered close to the surface of the Nb 3 Sn film.

Viklund, E.↗

Exploration of very high gradient cavities

Several of the 9-cell ILC cavities processed at Jlab within ongoing ILC R&D program have shown interesting behavior at high fields, such as mode mixing and sudden field emission turn-on during quench. Equipped with thermometry and oscillating superleak transducer (OST) system for quench detection, we couple our RF measurements with local dissipation measurements. In this contribution we report on our findings with high gradient SRF cavities.

43 PARTICLE ACCELERATORS↗

Gradient Limitations in Room Temperature and Superconducting Acceleration Structures

Accelerating gradient is a key parameter of the accelerating structure in large linac facilities, like future Linear Collider. In room temperature accelerating structures the gradient is limited mostly by breakdown phenomena, caused by high surface electric fields or pulse surface heating. High power processing is a necessary procedure to clean surface and improve the gradient. In the best tested X-band structures the achieved gradient is exceed 100 MV/m in of {approx}200 ns pulses for breakdown rate of {approx}10{sup -7}. Gradient limit depends on number of factors and no one theory which can explain all sets of experimental results and predict gradient in new accelerating structure. In paper we briefly overview the recent experimental results of breakdown studies, progress in understanding of gradient limitations and scaling laws. Although superconducting rf technology has been adopted throughout the world for ILC, it has frequently been difficult to reach the predicted performance in these structures due to a number of factors: multipactoring, field emission, Q-slope, thermal breakdown. In paper we are discussing all these phenomena and the ways to increase accelerating gradient in SC cavity, which are a part of worldwide R and D program.

43 PARTICLE ACCELERATORS↗

Gradient limitations in room temperature and superconducting acceleration structures

Accelerating gradient is a key parameter of the accelerating structure in large linac facilities, like future Linear Collider. In room temperature accelerating structures the gradient is limited mostly by breakdown phenomena, caused by high surface electric fields or pulse surface heating. High power processing is a necessary procedure to clean surface and improve the gradient. In the best tested X-band structures the achieved gradient is exceed 100 MV/m in of {approx}200 ns pulses for breakdown rate of {approx} 10{sup -7}. Gradient limit depends on number of factors and no one theory which can explain all sets of experimental results and predict gradient in new accelerating structure. In paper we briefly overview the recent experimental results of breakdown studies, progress in understanding of gradient limitations and scaling laws. Although superconducting rf technology has been adopted throughout the world for ILC, it has frequently been difficult to reach the predicted performance in these structures due to a number of factors: multipactoring, field emission, Q-slope, thermal breakdown. In paper we are discussing all these phenomena and the ways to increase accelerating gradient in SC cavity, which are a part of worldwide R&D program.

43 PARTICLE ACCELERATORS↗

Dispersion And Energy Compensation in High-Gradient Linacs for Lepton Colliders

The shape of an rf pulse is distorted due to dispersion encountered in acceleration through traveling-wave linear accelerator structures. Simulations are made to ascertain the severity of this distortion in cavities designed to operate at various group velocities. The pulse suffers maximum degradation when propagated through accelerating cavities with a phase advance per cell in the vicinity of {pi}, where the group velocity reaches its minimum value. Several cavities are simulated to study the pulse distortion and compared with experiments performed on a high phase advance structure H60VG3, which has a phase advance of 5{pi}/6 per cell. A circuit model and a mode matching code are used to perform these simulations on accelerating structures consisting of multiple cells. Beam loading is taken into account and the implications on energy dispersion are also analyzed. Means of mitigating for this energy deviation are discussed.

43 PARTICLE ACCELERATORS↗

Schemes of Laser Muon Acceleration: Ultra-Short, Micron-Scale Beams

Experimentally accessible schemes of laser muon (μ±) acceleration are introduced and modeled using a novel technique of controlled laser-driven post-processing of cascade showers (or pair plasmas). The proposed schemes use propagating structures in plasma, driven as wakefields of femtosecond-scale high-intensity laser, to capture particles of divergent cascade shower of: (a) hadronic type from proton-nucleon or photo-production reactions or, (b) electromagnetic type. Apart from the direct trapping and acceleration of particles of a raw shower in laser-driven plasma, a conditioning stage is proposed to selectively focus only one of the charge states. Not only is the high gradient that is sustained by laser-driven plasma structures well suited for rapid acceleration to extend the lifetime of short-lived muons but their inherent spatiotemporal scales also make possible production of unprecedented ultrashort, micron-scale muon beams. Compact laser muon acceleration schemes hold the promise to open up new avenues for applications.

43 PARTICLE ACCELERATORS↗

Structural Properties of Niobium Thin Films Deposited on Metallic Substrates by ECR

Particle accelerator technologies rely on SRF cavities to create the accelerating gradient for beam lines. Solid niobium cavities are widely employed throughout the community despite high material, fabrication, and operation cost. New thin film technologies are being explored for the suitability of niobium coatings for accelerating cavities. Thin layers of high-quality niobium would be deposited on a base material that has lower material and fabrication cost. Copper is a strong candidate for the cavity base due to availability, cost, machinability, and potentially improved performance characteristics of the niobium SRF surface. Initial results of TEM, EBSD and XRD analyses of niobium thin films grown on copper substrates under controlled conditions are presented to demonstrate the feasibility of the technology and establish lower limits of performance characteristics. Correlation of RRR data with the structure of niobium thin films will demonstrate the importance of thin film structural quality. *Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177.

Spradlin, Joshua↗