Search NASA⌕ Search

SEARCH · Search NASA

Results for “High current density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Domain wall-magnetic tunnel junction spin–orbit torque devices and circuits for in-memory computing

There are pressing problems with traditional computing, especially for accomplishing data-intensive and real-time tasks, that motivate the development of in-memory computing devices to both store information and perform computation. Magnetic tunnel junction memory elements can be used for computation by manipulating a domain wall, a transition region between magnetic domains, but the experimental study of such devices has been limited by high current densities and low tunnel magnetoresistance. Here, we study prototypes of three-terminal domain wall-magnetic tunnel junction in-memory computing devices that can address data processing bottlenecks and resolve these challenges by using perpendicular magnetic anisotropy, spin–orbit torque switching, and an optimized lithography process to produce average device tunnel magnetoresistance TMR = 171% and average resistance-area product RA = 29 Ω μm2, close to the RA of the unpatterned film. Device initialization variation in switching voltage is shown to be curtailed to 7%–10% by controlling the domain wall initial position, which we show corresponds to 90%–96% accuracy in a domain wall-magnetic tunnel junction full adder simulation. Repeatability of writing and resetting the device is shown. A circuit shows an inverter operation between two devices, showing that a voltage window is large enough, compared to the variation noise, to repeatably operate a domain wall-magnetic tunnel junction circuit. These results make strides in using magnetic tunnel junctions and domain walls for in-memory and neuromorphic computing applications.

Alamdar, Mahshid (ORCID:0000000221732935)↗

A round bobbin critical current measurement and thermal runaway simulation of REBCO coated conductors

A round bobbin test has been widely used to measure critical current Ic of practical superconductors including Nb–Ti, Nb3Sn, and Bi-2212 round strands at 4.2 K and in high magnetic fields but rarely used for rare earth-barium-copper-oxide (REBCO) coated conductor tapes. Here, we applies this method to REBCO tapes and test their Ic at 77 K, self-field, and 4.2 K with a magnetic field of 14 T applied parallel to the tape. The sample carries very high current densities; it is 1.3 m long and has a dense array of voltage taps that allows probing localized thermal runaways and correlation with Ic variations along the length. At 77 K, the Ic values of all sections were measured and found to be rather uniform. However, at 4.2 K, we found that a 3 cm section has 90% of the overall voltage drop and it went into thermal runaways upon further increasing current. Thus, at 4.2 K, we were prevented by localized thermal runaways and unable to determine Ic of most of the REBCO conductor sections; this behavior is different from Bi-2212 and Bi-2223 for which Ic of all turns of a round barrel sample can be determined. We simulate REBCO tapes during current ramping to a thermal runaway and analyze impacts of various factors including cooling, conductor n-values, and thickness of stabilizer on the thermal runaway current Iq. The combined experiments and simulations identify n-value as a crucial factor that leads to the observed differences between Bi-2212 and REBCO. Together with cooling and the standard deviation of Ic variations along the length, the n-value determines whether Iq is above or below the average Ic of a long piece of conductor and their ratio Iq/Ic,ave, greatly affecting quench detection and thermal runaway prevention strategies of Bi-2212 and REBCO magnets.

Mosat, Marek↗

Inertially enhanced mass transport using 3D-printed porous flow-through electrodes with periodic lattice structures

Significance The efficient utilization of electrical energy is an increasingly important challenge, especially as renewable energy sources become cheaper and demand increases. Electrochemical reactors utilizing flow-through electrodes (FTEs) provide an attractive path toward the efficient utilization of electrical energy. Their commercial viability and ultimate adoption hinge on attaining high current densities to drive cost competitiveness. There are limited opportunities for engineering FTE materials, as these are often random, disordered media. Alternatively, three-dimensional (3D)–printed FTEs provide the opportunity to quickly explore the impact of engineered electrode architectures on device performance. We demonstrate that 3D-printed FTEs have the potential to exceed the performance of conventional materials by using the expanded design freedom to engineer the internal flow.

30 DIRECT ENERGY CONVERSION↗

Seawater alkalization via an energy-efficient electrochemical process for CO 2 capture

Electrochemical pH-swing strategies offer a promising avenue for cost-effective and energy-efficient carbon dioxide (CO 2 ) capture, surpassing the traditional thermally activated processes and humidity-sensitive techniques. The concept of elevating seawater’s alkalinity for scalable CO 2 capture without introducing additional chemical as reactant is particularly intriguing due to its minimal environmental impact. However, current commercial plants like chlor-alkali process or water electrolysis demand high thermodynamic voltages of 2.2 V and 1.23 V, respectively, for the production of sodium hydroxide (NaOH) from seawater. These high voltages are attributed to the asymmetric electrochemical reactions, where two completely different reactions take place at the anode and cathode. Here, we developed a symmetric electrochemical system for seawater alkalization based on a highly reversible and identical reaction taking place at the anode and cathode. We utilize hydrogen evolution reaction at the cathode, where the generated hydrogen is looped to the anode for hydrogen oxidation reaction. Theoretical calculations indicate an impressively low energy requirement ranging from 0.07 to 0.53 kWh/kg NaOH for established pH differences of 1.7 to 13.4. Experimentally, we achieved the alkalization with an energy consumption of 0.63 kWh/kg NaOH, which is only 38% of the theoretical energy requirements of the chlor-alkali process (1.64 kWh/kg NaOH). Further tests demonstrated the system’s potential of enduring high current densities (~20 mA/cm 2 ) and operating stability over an extended period (>110 h), showing its potential for future applications. Notably, the CO 2 adsorption tests performed with alkalized seawater exhibited remarkably improved CO 2 capture dictated by the production of hydroxide compared to the pristine seawater.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonlinear second order electromagnetic gyrokinetic theory for a tokamak plasma

The steep plasma pressure gradient that forms at the edge of the high confinement, H-mode regime of tokamak operation provides free energy to drive electromagnetic micro-instabilities that are widely believed to influence the transport processes in this so-called pedestal region. This high pressure gradient also provides a high current density (bootstrap current), known to influence ballooning mode stability and to be important for driving kink modes in the ideal magneto-hydrodynamic plasma model (so-called peeling-ballooning modes). Furthermore, efficient, steady state future tokamak power plants must operate with a large bootstrap current in the core and especially concerning spherical tokamaks, confinement will be influenced by electromagnetic turbulence. To accommodate these important situations, conventional electromagnetic gyrokinetic theory is extended to incorporate neoclassical effects in the equilibrium drives, allowing $B_{\vartheta} ~ B_0$ (B0 is the confining magnetic field, and $B_{\vartheta}$ is its poloidal component). This provides a global gyrokinetic model that self-consistently captures the consequences of large bootstrap current fractions on the equilibrium distribution functions.

kink modes↗

A turnkey gaseous helium-cooled superconducting CORC ® dc power cable with integrated current leads

Abstract High-temperature superconducting (HTS) direct current (dc) power cable systems, capable of delivering power exceeding 10 MW while being cooled with cryogenic helium gas, have been developed for applications on naval electric ships, electric aircraft and in data centers. Current injection from room temperature into the superconducting power cable causes by far the greatest heat load to the cryogenic system. Efficient current leads with integrated helium gas heat exchangers were developed to inject a current exceeding 1 kA from room temperature into a superconducting Conductor on Round Core (CORC ® ) power cable, without the need for liquid nitrogen pre-cooling. A 2 m long single-pole CORC ® power cable system that included current leads was cooled using a Stirling cryocooler with a closed-loop helium gas circulation system. The turnkey power cable system allowed cool down from room temperature to its operating temperature of 60 K–70 K within 5 h, after which continuous operation at 1.2 kA was demonstrated. The successful development and demonstration of a CORC ® power cable with current leads containing integrated helium gas heat exchangers enables widespread implementation of HTS MW-class, high current density superconducting dc power cables in many applications with constrained space that require a power dense solution.

Physics↗

Dynamic Nuclear Spin Polarization Induced by the Edelstein Effect at Bi(111) Surfaces

Nuclear spin polarization induced by hyperfine interaction and mainly the Edelstein effect due to strong spin-orbit interaction, is investigated by quantum transport in Bi(111) thin film samples. The Bi(111) films are deposited on mica by van der Waals epitaxial growth. The Bi(111) films show micrometer-sized triangular islands with 0.39 nm step height, corresponding to the Bi(111) bilayer height. At low temperatures a high current density is applied to generate a nonequilibrium carrier spin polarization by mainly the Edelstein effect at the Bi(111) surface, which then induces dynamic nuclear polarization by hyperfine interaction. Here, comparative quantum magnetotransport antilocalization measurements indicate a suppression of antilocalization by the in-plane Overhauser field from the nuclear polarization and allow a quantification of the Overhauser field. Hence nuclear polarization was both achieved and quantified by a purely electronic transport-based approach.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coupled Electro-Thermal Analysis of Permanent Magnet Synchronous Motor for Electric Vehicles

Permanent magnet synchronous motors (PMSM) are extensively used in electric vehicles. However, high internal heat generation and inefficient heat dissipation often limit the operational reliability, and longevity of the PMSM. Therefore, proper quantification of heat generation in electric motor and advanced embedded motor cooling techniques remain topics of immense interest. In order to accurately predict electro-magnetic performance, i.e., efficiency, component-wise heat losses and the corresponding temperature distribution of a jacket cooled machine, this paper presents a two-way iteratively coupled electro-thermal modeling framework. Finite element based software Motor-CAD has been utilized for electro-magnetic performance calculation of BMW i3 PMSM. Finite volume based computational fluid dynamics/heat transfer (CFD/HT) software ANSYS® FLUENT® has been employed to simulate the temperature distribution of the PMSM, using the electro-magnetic losses as heat input. Computed heat losses, stator, winding, rotor, and magnet temperatures are utilized as coupling parameters between the electro-magnetic and thermal models. A conventional one-way coupling algorithm has also been developed and compared to the newly proposed two-way coupling algorithm. Numerical results confirm that at high current density, one-way coupling algorithm significantly over-predicts the motor temperature compared to the two-way algorithm. A comprehensive analysis has been carried out to characterize the influences of current density, speed, and forced convection heat transfer coefficient on the heat losses, overall efficiency, and maximum temperature of the PMSM. Lastly, an efficiency map has been interpreted from the coupled electro-magnetic simulation.

42 ENGINEERING↗

Thin-Film Module Reverse-Bias Breakdown Sites Identified by Thermal Imaging

Thin-film module sections are stressed under reverse bias to simulate partial shading conditions. Such stresses can cause permanent damage in the form of "wormlike" defects due to thermal runaway. When large reverse biases with limited current are applied to the cells, dark lock-in thermography (DLIT) can detect where spatially-localized breakdown initiates before thermal runaway leads to permanent damage. Predicted breakdown defect sites have been identified in both CIGS and CdTe modules using DLIT. These defects include small pinholes, craters, or voids in the absorber layer of the film that lead to builtin areas of weakness where high current densities may cause thermal damage in a partial-shading event.

14 SOLAR ENERGY↗

Quench Protection by Putting a Current-pulse Into a Coil Center-Tap in HTS Coils

Forty years ago, Lawrence Berkeley Laboratory (LBL) tested a pulsed current quench protection system for a high current density two-meter diameter two-layer solenoid at 4.5 K with a stored energy of 8.5 MJ. The energy needed to protect this magnet was 13.4 kJ from an electrolytic capacitor system charged to voltages 800 V. This method also involved the use of a well-coupled shorted secondary circuits and quench-back. The applicability of this quench protection method to HTS magnets operating at temperatures >25 K could be of interest. There are a number of questions that should be asked, as follows: 1) Can this method work for HTS coils operating at temperatures >25 K? 2) Are there batteries or capacitors that can store 2 MJ or more that have short enough discharge times for quench protection at voltages less than 2 kV? 3) Is this quench protection system cost low enough to be reasonable?

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the effect of ballistic overflow on the temperature dependence of the quantum efficiency of InGaN/GaN multiple quantum well light-emitting diodes

The dependences of the quantum efficiency of InGaN/GaN multiple quantum well light-emitting diodes on the temperature and excitation level are studied. The experiment is performed for two luminescence excitation modes. A comparison of the results obtained during photo- and electroluminescence shows an additional (to the loss associated with Auger recombination) low-temperature loss in the high-density current region. This causes inversion of the temperature dependence of the quantum efficiency at temperatures lower than 220–300 K. Analysis shows that the loss is associated with electron leakage from the light-emitting-diode active region. The experimental data are explained using the ballistic-overflow model. The simulation results are in qualitative agreement with the experimental dependences of the quantum efficiency on temperature and current density.

36 MATERIALS SCIENCE↗

Generation of Terahertz Radiation in Magnetic Junctions Based on Nanowires

A system of spin-injection emitters employing magnetic junctions based on an array of parallel nanodimensional wires has been studied. Manufacturing technology and possible variants of the nanowire structure are discussed. Conditions of the formation of a new type of spin-injection emitters of terahertz radiation on this basis are considered. The design of the experimental setup is described, and the results of experiments are analyzed. It is established that signals in a 16–18 THz range can be generated by passing high-density current through the proposed nanowire array.

42 ENGINEERING↗

Revealing the Nanostructure of Mesoporous Fuel Cell Catalyst Supports for Durable, High-Power Performance

Achieving high power performance and durability with low Pt loadings are critical challenges for proton exchange membrane fuel cells. PtCo catalysts developed on new carbon black supports show promise by simultaneously providing good oxygen reduction kinetics and local oxygen transport. We investigate the role of nanoscale morphology in the performance of these catalysts supported on accessible (HSC-e and HSC-f) and conventional (Ketjen Black) porous carbons using 3D electron tomography, nitrogen sorption, and electrochemical performance measurements. We find that the accessible porous carbons have hollow interiors with mesopores that are larger and more numerous than conventional porous carbons. However, mesopore-sized openings (>2 nm width) are too rare to account for significant oxygen transport. Instead we propose the primary oxygen transport pathway into the interior is through 1–2 nm microporous channels permeating the carbon. The increased mesoporosity in the accessible porous carbons results in a shorter diffusion pathlength through constrictive, tortuous micropores in the support shell leading to lower local oxygen transport resistance. In durability testing, the accessible porous carbons show faster rates of electrochemical surface area loss, likely from fewer constrictive pores that would mitigate coarsening, but maintain superior high current density performance at end of test from the improved local oxygen transport.

Electrochemistry↗

Baselining Activity and Stability of ORR Catalysts and Electrodes for Proton Exchange Membrane Fuel Cells for Heavy-Duty Applications

Activity and stability of electrodes with Pt and PtCo alloy catalysts supported on high surface area carbon, hereafter to as a-Pt/C and d-PtCo/C, were evaluated for heavy-duty applications. Both catalysts had nearly identical Pt loading (50-wt% Pt on carbon and 0.25 mg Pt cm −2 ) and had undergone thermal treatment to stabilize them by growing the average particle size to 4–5 nm. Both were subjected to 90,000 (90 k) standard accelerated stress tests (AST) cycles consisting of 0.6–0.95 V square wave potentials, 3-s hold at upper and lower potential limits in H 2 /N 2 at 1.5 atm, 80 °C and 100% RH. Test protocols were developed to monitor the performance losses and characterize them in terms of activity for the oxygen reduction reaction (ORR), oxygen transport in the electrode and proton transport in the membrane and cathode catalyst layer. Despite the nearly double initial ORR activity, the PtCo/C electrode degraded faster due to the leaching of Co from the catalyst that had started even before the imposition of the AST potential cycles. Commensurate with Co leaching, Co poisoning of ionomer is responsible for the inferior performance of d-PtCo/C electrode at high current densities both before and after AST.

30 DIRECT ENERGY CONVERSION↗

LiCl–Based Aqueous Electrolytes for Efficient Iron Electrodeposition

This study investigates room temperature, aqueous electrolytes for efficient iron electrodeposition. Specifically, a novel lithium chloride-based electrolyte was identified to suppress hydrogen evolution while promoting fast kinetics of iron electrodeposition, achieving high coulombic efficiency (>90%) at high current densities (>400 mA cm −2 ). Electrochemical analysis of the partial current densities of iron deposition and hydrogen co-evolution revealed that water reduction is kinetically suppressed in this electrolyte, resulting in an increase in the measured coulombic efficiency. Furthermore, a detailed investigation of the iron speciation and their complexation was performed, which revealed that, in concentrated LiCl-containing electrolytes, the ferrous (Fe 2+ ) species coordinate with chloride rather than water, enhancing deposition kinetics. The combined effect of enhanced electrodeposition kinetics and suppressed water activity provide elevated coulombic efficiency. Overall, this paper develops an understanding of anion and cation effects on the mechanism of electrodeposition and hydrogen co-evolution in concentrated electrolytes in search of improved aqueous media (e.g., concentrated LiCl) for efficient metal electro-synthesis.

Lvovich, William [Case Western Reserve University,↗

Enhanced MEA Performance for PEMFCs under Low Relative Humidity and Low Oxygen Content Conditions via Catalyst Functionalization

This work demonstrates that functionalizing annealed-Pt/Ketjen black EC300j (a-Pt/KB) and dealloyed-PtNi/Ketjen black EC300j (d-PtNi/KB) catalysts using p-phenyl sulfonic acid can effectively enhance performance in the membrane electrode assemblies (MEAs) of proton exchange membrane fuel cells (PEMFCs). The functionalization increased the size of both Pt and PtNi catalyst particles and resulted in the further leaching of Ni from the PtNi catalyst while promoting the formation of nanoporous PtNi nanoparticles. The size of the SO3H-Pt/KB and SO3H-PtNi/KB carbon-based aggregates decreased dramatically, leading to the formation of catalyst layers with narrower pore size distributions.MEA tests highlighted the benefits of the surface functionalization, in which the cells with SO3H-Pt/KB and SO3H-PtNi/KB cathode catalysts showed superior high current density performance under reduced RH conditions, in comparison with cells containing annealed Pt/KB (a-Pt/KB) and de-alloyed PtNi/KB (d-PtNi/KB) catalysts. The performance improvement was particularly evident when using reactant gases with low relative humidity, indicating that the hydrophilic functional groups on the carbon improved the water retention in the cathode catalyst layer. These results show a new avenue for enhancing catalyst performance for the next generation of catalytic materials for PEMFCs.

Xin, Le↗

Electrocatalytic Reduction of CO 2 at Au Nanoparticle Electrodes: Effects of Interfacial Chemistry on Reduction Behavior

Nanoscale Au electrocatalysts demonstrate the extraordinary ability to reduce CO 2 at low overpotentials with high selectivity to CO. Here, we investigate the role of surface chemistry on CO 2 reduction behavior using Au 25 and 5 nm Au nanoparticles. Onset potentials for CO 2 reduction at Au 25 nanoparticles in Nafion binders are shifted anodically by 190 mV while the hydrogen evolution reaction is shifted cathodically by 300 mV relative to Au foil. The net effect of this beneficial separation in onset potentials is relatively high Faradayic efficiencies for CO (90% at 0.8 V versus RHE) at high current densities. Experimental results show Faradayic efficiencies for CO are greatest using electrodes made with Nafion-immobilized Au 25 nanoparticles. Likewise, CO 2 reduction onset potential shifts are greater for smaller nanoparticles and when Nafion binders are used instead of (sulfonate-free) polyvinylidene fluoride. X-ray photoelectron spectroscopy analysis reveals Au nanoparticles may react with the sulfonates of Nafion binders. Here, the results suggest sulfonate interfaces may alter the binding energies of key species or lead to favorable reconstructions, either of which ultimately results in remarkable improvements in Faradayic efficiencies relative to Au foil electrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Contaminant Cation Effect on Oxygen Transport through the Ionomers of Polymer Electrolyte Membrane Fuel Cells

We characterized the effects of cobalt (Co 2+ ) and other cation contaminants on the oxygen (O 2 ) transport properties of the PFSA ionomer used in polymer electrolyte membrane fuel cells (PEMFCs) and gained insight into the mechanisms by which contaminant cations inhibit O 2 transport. Such cations can be released by alloy catalysts and environmental conditions and pose a significant challenge to maintaining high current density performance with low platinum (Pt) loadings. We used a test cell capable of isolating the ionomer from the membrane electrode assembly (MEA), allowing for O 2 transport resistance (R O2 ) measurements using a limiting current technique. We contaminated ionomer membranes with Li + , Na + , Ni 2+ , Co 2+ , and Ce 3+ and found a general increase in R O2 for increased contamination levels and decreased water activity. In addition, our Co 2+ results indicated distinct concentration-dependent regimes. The other cation-form ionomers allowed us to separate the impacts of ion pair strength, multivalency, and reduced water uptake. We believe that these factors cause a more compressed hydrophilic domain and tortuous O 2 diffusion path, and a commensurate increase in R O2 . Lastly, we studied the impact of Co 2+ on an operating PEMFC and found an increase in R O2 consistent with the results of our isolated membrane tests.

25 ENERGY STORAGE↗