Search NASA⌕ Search

SEARCH · Search NASA

Results for “High precision control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

A versatile technique to enable sub-milli-Kelvin instrument stability for precise radial velocity measurements: tests with the habitable-zone planet finder

Insufficient instrument thermomechanical stability is one of the many roadblocks for achieving 10 cm s{sup −1} Doppler radial velocity precision, the precision needed to detect Earth-twins orbiting solar-type stars. Highly temperature and pressure stabilized spectrographs allow us to better calibrate out instrumental drifts, thereby helping in distinguishing instrumental noise from astrophysical stellar signals. We present the design and performance of the Environmental Control System (ECS) for the Habitable-zone Planet Finder (HPF), a high-resolution (R = 50,000) fiber-fed near-infrared (NIR) spectrograph for the 10 m Hobby–Eberly Telescope at McDonald Observatory. HPF will operate at 180 K, driven by the choice of an H2RG NIR detector array with a 1.7 μm cutoff. This ECS has demonstrated 0.6 mK rms stability over 15 days at both 180 and 300 K, and maintained high-quality vacuum (<10{sup −7} Torr) over months, during long-term stability tests conducted without a planned passive thermal enclosure surrounding the vacuum chamber. This control scheme is versatile and can be applied as a blueprint to stabilize future NIR and optical high-precision Doppler instruments over a wide temperature range from ∼77 K to elevated room temperatures. A similar ECS is being implemented to stabilize NEID, the NASA/NSF NN-EXPLORE spectrograph for the 3.5 m WIYN telescope at Kitt Peak, operating at 300 K. A [full SolidWorks 3D-CAD model] and a comprehensive parts list of the HPF ECS are included with this manuscript to facilitate the adaptation of this versatile environmental control scheme in the broader astronomical community.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermally Stable Nanocatalyst for High Temperature Reactions: Pt-Mesoporous Silica Core-Shell Nanoparticles

Recent advances in colloidal synthesis enabled the precise control of size, shape and composition of catalytic metal nanoparticles, allowing their use as model catalysts for systematic investigations of the atomic-scale properties affecting catalytic activity and selectivity. The organic capping agents stabilizing colloidal nanoparticles, however, often limit their application in high-temperature catalytic reactions. Here we report the design of a high-temperature stable model catalytic system that consists of Pt metal core coated with a mesoporous silica shell (Pt{at}mSiO{sub 2}). While inorganic silica shells encaged the Pt cores up to 750 C in air, the mesopores directly accessible to Pt cores made the Pt{at}mSiO{sub 2} nanoparticles as catalytically active as bare Pt metal for ethylene hydrogenation and CO oxidation. The high thermal stability of Pt{at}mSiO{sub 2} nanoparticles permitted high-temperature CO oxidation studies, including ignition behavior, which was not possible for bare Pt nanoparticles because of their deformation or aggregation. The results suggest that the Pt{at}mSiO{sub 2} nanoparticles are excellent nanocatalytic systems for high-temperature catalytic reactions or surface chemical processes, and the design concept employed in the Pt{at}mSiO{sub 2} core-shell catalyst can be extended to other metal-metal oxide compositions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A rotational and axial motion system load frame insert for in situ high energy x-ray studies

High energy x-ray characterization methods hold great potential for gaining insight into the behavior of materials and providing comparison datasets for the validation and development of mesoscale modeling tools. A suite of techniques have been developed by the x-ray community for characterizing the 3D structure and micromechanical state of polycrystalline materials; however, combining these techniques with in situ mechanical testing under well characterized and controlled boundary conditions has been challenging due to experimental design requirements, which demand new high-precision hardware as well as access to high-energy x-ray beamlines. We describe the design and performance of a load frame insert with a rotational and axial motion system that has been developed to meet these requirements. An example dataset from a deforming titanium alloy demonstrates the new capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Innovative approach to counterfeit and noncompliant refrigerant detection: A cost-effective, portable solution

The increasing prevalence of counterfeit and incompatible refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC&R) systems, including compromised equipment performance, safety hazards, and non-compliance. This article details the development of a novel, cost-effective, and portable detection device designed to accurately verify refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing feedback within a 2-minute duration. Laboratory validation demonstrated the device’s high accuracy (>95 % based on correct identification of compliant vs. non-compliant blends) in detecting unauthorized refrigerant blends. The projected cost of the product stands at ∼ $150, based on the retail pricing of individual components. Laboratory validation demonstrated the device’s high accuracy (>95 % for composition identification, 100 % rejection of tested counterfeit/incorrect blends) in detecting unauthorized refrigerant blends with a response time <2 min. The device correctly identified authentic R-454A/B/C blends and reliably rejected R-407F and closely related counterfeit mixtures. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks, enhances safety in HVAC&R operations, and mitigates the risks associated with counterfeit refrigerants.

Counterfeit refrigerants↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity.Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the American Innovation and Manufacturing (AIM) Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

99 GENERAL AND MISCELLANEOUS↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity. Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the AIM Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic Precision Processing of Two-Dimensional Materials for Next-Generation Microelectronics

The growth of the information era economy is driving the pursuit of advanced materials for microelectronics, spurred by exploration into “Beyond CMOS” and “More than Moore” paradigms. Atomically thin 2D materials, such as transition metal dichalcogenides (TMDCs), show great potential for next-generation microelectronics due to their properties and defect engineering capabilities. This perspective delves into atomic precision processing (APP) techniques like atomic layer deposition (ALD), epitaxy, atomic layer etching (ALE), and atomic precision advanced manufacturing (APAM) for the fabrication and modification of 2D materials, essential for future semiconductor devices. Additive APP methods like ALD and epitaxy provide precise control over composition, crystallinity, and thickness at the atomic scale, facilitating high-performance device integration. Subtractive APP techniques, such as ALE, focus on atomic-scale etching control for 2D material functionality and manufacturing. In APAM, modification techniques aim at atomic-scale defect control, offering tailored device functions and improved performance. Achieving optimal performance and energy efficiency in 2D material-based microelectronics requires a comprehensive approach encompassing fundamental understanding, process modeling, and high-throughput metrology. Finally, the outlook for APP in 2D materials is promising, with ongoing developments poised to impact manufacturing and fundamental materials science. Integration with advanced metrology and codesign frameworks will accelerate the realization of next-generation microelectronics enabled by 2D materials.

36 MATERIALS SCIENCE↗

Carrier recombination dynamics and temperature dependent optical properties of InAs–GaSb heterostructures

Heterostructures with two dissimilar materials could offer unprecedented properties if one can carefully synthesize these heterostructures with atomically smooth interfaces and reduced number of recombination centers. InAs/GaSb-based heterostructures have technological importance for long wavelength infrared photodetectors if one can synthesize these materials with high-optical quality and high-carrier lifetime. In this work, the InAs/GaSb heterostructures with a different number of heterointerfaces and growth conditions were grown by solid source molecular beam epitaxy using valved cracker sources for both arsenic and antimony. Precise control of growth parameters and shutter sequences enabled abrupt InAs/GaSb heterointerfaces, as supported by a high-resolution transmission electron microscopic study. The temperature and power-dependent optical properties by photoluminescence (PL) spectroscopic analysis of InAs/GaSb heterostructures with 4 and 28 heterointerfaces displayed donor to the acceptor and the exciton bound to complex defects (V Ga Ga Sb ) 0 . Since the optical transition in PL measurements serves to determine the quality of the material, and the observed excitonic transitions from these InAs/GaSb heterostructures is an indication of high-quality materials. The high-carrier lifetimes of 139 ns to 185 ns from InAs/GaSb heterostructures were measured using microwave photoconductivity decay (μ-PCD) technique at room temperature. The observed increase in carrier lifetime is due to the decreasing number of Ga-related carrier recombination centers or defect complexes. This is further supported by the PL spectroscopic study. In addition, the carrier lifetime with different injection levels is supported by Shockley–Read–Hall recombination. We report these InAs/GaSb heterostructures with high-optical quality and high-carrier lifetimes would offer a path for the development of high-performance infrared photodetectors.

36 MATERIALS SCIENCE↗

Ultrathin PdPt bimetallic nanowires with enhanced electrocatalytic performance for hydrogen evolution reaction

We report a general bottom-up synthetic methodology to epitaxially grow 3-nm-thick single-crystalline PdPt bimetallic nanowires using amphiphilic dioctadecyldimethylammonium chloride as the surfactant template. Mechanistic studies show that the existence of Pd element is critical in the synthesis of bimetallic PdPt nanowires with controllable atomic ratios. Due to synergistic effect of anisotropic single-crystalline ultrathin one-dimensional nanostructures and bimetallic elemental compositions, the resulting PdPt nanowires exhibit superior electrocatalytic activity and stability towards the hydrogen evolution reaction (HER). Among them, bimetallic Pd 86 Pt 14 nanowires show the best HER activity with a small overpotential of only 0.8 mV in acidic media at a current density of 10 mA/cm 2 (12.8 mV positive than that of commercial Pt nanoparticles), and excellent stability with only 4.6% loss in activity after current-time chronoamperometric responses for 26 h. As a result, this surfactant template-directing approach opens a general method for precise control of anisotropic nanostructures in diverse bimetallic nanomaterials for the high-performance electrocatalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Engineering the atomic structure of sequence-defined peptoid polymers and their assemblies

Peptoids are a family of sequence-defined, non-natural biomimetic polymers which show excellent properties including good chemical and enzymatic stability and high structural tunability. The solid-phase submonomer synthesis method allows precise control over the identity and sequence of chemically diverse side chains, enabling the atomic engineering of their chemical structures for a variety of applications. This unprecedented level of structural control enables access to atomically defined three-dimensional chain conformations and assemblies, facilitating the design and optimization of a variety of nanoscale architectures that can function in biology and materials science. In order to approach the rational design of peptoid materials in a more predictive and precise manner, it is crucial to fully understand how chemical information, in the form of the monomer sequence, encodes their folding and assembly into structurally defined, functional 3D shapes. Furthermore, this perspective focuses on recent studies into the atomic engineering of peptoid nanostructures by examining the impact of sequence variations on their secondary and three-dimensional structures, as well as their functional properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Generation of Tin-Vacancy Centers in Diamond via Shallow Ion Implantation and Subsequent Diamond Overgrowth

Group IV color centers in diamond have garnered great interest for their potential as optically active solid-state spin qubits. The future utilization of such emitters requires the development of precise site-controlled emitter generation techniques that are compatible with high-quality nanophotonic devices. This task is more challenging for color centers with large group IV impurity atoms, which are otherwise promising because of their predicted long spin coherence times without a dilution refrigerator. For example, when applied to the negatively charged tin-vacancy (SnV – ) center, conventional site-controlled color center generation methods either damage the diamond surface or yield bulk spectra with unexplained features. Here we demonstrate a novel method to generate site-controlled SnV – centers with clean bulk spectra. We shallowly implant Sn ions through a thin implantation mask and subsequently grow a layer of diamond via chemical vapor deposition. This method can be extended to other color centers and integrated with quantum nanophotonic device fabrication.

36 MATERIALS SCIENCE↗

Deterministic Fabrication of Large-Area, High-Crystallinity Oxide Moiré Superlattices

Oxide twistronics extends moiré engineering beyond van der Waals materials, offering a promising platform for accessing emergent interfacial phenomena arising from the strong coupling of lattice, charge, and orbital degrees of freedom in complex oxides. However, deterministic fabrication of high-crystallinity oxide moiré superlattices over large lateral dimensions remains challenging due to the three-dimensional bonding network of oxides. Here, we demonstrate a scalable, generalized fabrication strategy that enables the formation of high-crystallinity oxide moiré superlattices with clean, chemically bonded interfaces and precisely controlled twist angles down to nominal values of 0.1°, achieving subdegree twist-angle accuracy across large contiguous lateral dimensions approaching the millimeter scale. Using NaNbO3 as a model system, we show that the resulting interlayer coupling drives pronounced structural reconstruction that modifies both the phase structure and ferroelectric domain configuration. Synchrotron-based X-ray 3D reciprocal space mapping reveals the emergence of a single-phase state in twisted bilayers, in contrast to the mixed-phase structure observed in single-layer membranes prior to twist assembly. The structural signatures are further consistent with gradual lattice rotation distributed along the thickness direction that may accommodate interfacial shear strain, distinct from reconstruction observed in van der Waals moiré systems which primarily occurs through in-plane stacking rearrangement. This collective lattice response is correlated with twist-dependent nanoscale electromechanical modulations observed by piezoresponse force microscopy. These results establish a scalable materials platform for oxide twistronics and support the implementation of twist-engineered functionalities in practical, macroscale device architectures.

Ghanbari, Reza [North Carolina State University (N↗

Progress towards ignition on the National Ignition Facility

The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory includes a precision laser system now capable of delivering 1.8 MJ at 500 TW of 0.35-μm light to a target. NIF has been operational since March 2009. A variety of experiments have been completed in support of NIF's mission areas: national security, fundamental science, and inertial fusion energy. NIF capabilities and infrastructure are in place to support its missions with nearly 60 X-ray, optical, and nuclear diagnostic systems. A primary goal of the National Ignition Campaign (NIC) on the NIF was to implode a low-Z capsule filled with ∼0.2 mg of deuterium-tritium (DT) fuel via laser indirect-drive inertial confinement fusion and demonstrate fusion ignition and propagating thermonuclear burn with a net energy gain of ∼5–10 (fusion yield/input laser energy). This requires assembling the DT fuel into a dense shell of ∼1000 g/cm{sup 3} with an areal density (ρR) of ∼1.5 g/cm{sup 2}, surrounding a lower density hot spot with a temperature of ∼10 keV and a ρR ∼0.3 g/cm{sup 2}, or approximately an α-particle range. Achieving these conditions demand precise control of laser and target parameters to allow a low adiabat, high convergence implosion with low ablator fuel mix. We have demonstrated implosion and compressed fuel conditions at ∼80–90% for most point design values independently, but not at the same time. The nuclear yield is a factor of ∼3–10× below the simulated values and a similar factor below the alpha dominated regime. This paper will discuss the experimental trends, the possible causes of the degraded performance (the off-set from the simulations), and the plan to understand and resolve the underlying physics issues.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Low-energy ion beam sputtering of polycrystalline diamond

Ion beam milling is a highly versatile and precise technique for the microfabrication of diamond films, enabling controlled material removal at both micrometer and sub-micrometer scales while accommodating complex geometries and surface features. Comprehensive sputtering yield data are essential for process optimization. In this work, we systematically measure the sputter yield of polycrystalline diamond bombarded with $\textrm{N}_2^+$, Ne + , Ar + , Kr + , and Xe + ions over an energy range of 300–900 eV and beam incidence angles of 0°−80°, providing data critical for precision machining applications. Results show that the sputter yield increases with both ion energy and the incidence angle and decreases with increasing ion mass. For $\textrm{N}_2^+$ ions, the sputter yield is largely insensitive to ion energy and exceeds values expected for pure physical sputtering. The concurrent formation of volatile C 2 N 2 molecules during $\textrm{N}_2^+$ ion bombardment suggests that the process is dominated by chemical sputtering. The absence of a peak in the dependence of the sputter yield on the beam incidence angle expected at oblique incidence angles is attributed to the effects of surface roughness.

Materials science↗

Optimizing spectral phase transfer in four-wave mixing with gas-filled capillaries

Four-wave mixing (FWM) in gas-filled hollow-core capillaries, a nonlinear optical process that mixes signal and pump photon frequencies to generate idler frequency photons, offers a method for precise spectral phase transfer from signal to idler at ultrashort timescales and extreme powers. However, this regime is challenged by competing linear and nonlinear dynamics, leading to significant trade-offs between spectral phase transfer and conversion efficiency. Our computational investigation focuses on the upconversion of femtosecond pulses from the infrared (IR) to the ultraviolet (UV), a range notoriously difficult to manipulate. We explore an intermediate energy regime that strikes an optimal balance between FWM-mediated phase-transfer fidelity and nonlinear conversion efficiency. By adjusting the energy ratios and spectral phase profiles of the input signal, we achieve conversion efficiencies of approximately 5-15% while maintaining an effective quasi-linear spectral phase transfer. These findings will contribute to establishing first-principles and scaling laws essential for applications such as high-precision imaging, spectroscopy, quantum transduction, and distributed entangled interconnects, facilitating advanced control of ultrafast photonic and electronic wavepackets in quantum materials with unprecedented spatial and temporal precision.

Zhang, Hao↗

Physics of Neutrino Oscillations and Neutrino Cross Sections using the NOvA Experiment

NOvA is a long-baseline accelerator-based neutrino experiment based in the US. NOvA uses an intense neutrino beam produced at Fermilab’s accelerator complex to make physics measurements of neutrino oscillations, neutrino cross sections, and much more. For its physics goals, NOvA uses two functionally-identical detectors. The Near Detector (ND) is situated at Fermilab, 1 km from the neutrino target and the Far Detector (FD) is located at Ash River, MN, a distance of 810 km from the neutrino source. The ND receives a high statistics neutrino flux which gives a unique opportunity for high-precision neutrino cross-section measurements and is used as a control for the oscillation analyses. The FD is used to analyze the appearance and disappearance of the neutrinos arriving from the Fermilab. The purpose of the oscillation analysis is to understand the dominance of matter over antimatter in the universe, to resolve the ordering of neutrino masses, and to resolve the octant of the neutrino mixing angle theta23. In this talk, I will give an overview of the NOvA experiment. I will also talk about the status of the NOvA’s cross-section physics program and the latest results from the oscillation analyses. I will also talk about the future prospects of the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutrino Scattering in the NOvA Near Detector

aNOvA is a long-baseline accelerator-based neutrino experiment based in the USA. NOvA uses an intense neutrino beam produced at Fermilab’s accelerator complex to make physics measurements of neutrino oscillations, neutrino cross sections, and much more. For its physics goals, NOvA uses two functionally-identical detectors. The Near Detector (ND) is situated at Fermilab, 1 km from the neutrino target and the Far Detector (FD) is located at Ash River, MN, a distance of 810 km from the neutrino source. The ND receives a high statistics neutrino flux which gives a unique opportunity for high-precision neutrino cross-section measurements and is used as a control for the oscillation analyses. In this talk/poster, I will give an overview of the NOvA experiment. I will also talk about the current and future status of the NOvA’s cross-section physics program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First measurements with the CMS DAQ and Timing Hub prototype-1

The DAQ and Timing Hub is an ATCA hub board designed for the Phase-2 upgrade of the CMS experiment. In addition to providing high-speed Ethernet connectivity to all back-end boards, it forms the bridge between the sub-detector electronics and the central DAQ, timing, and trigger control systems. One important requirement is the distribution of several high-precision, phase-stable, and LHC synchronous clock signals for use by the timing detectors. The current paper presents first measurements performed on the initial prototype, with a focus on clock quality. It is demonstrated that the current design provides adequate clock quality to satisfy the requirements of the Phase-2 CMS timing detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗