Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hourly data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Radio Noise Problems in Arctic Regions

Three main types of radio noise should be considered when establishing noise levels for communication purposes or in experiments utilizing radio techniques in Arctic regions. These are atmospheric and man-made noise, and precipitation static. National Bureau of Standards radio noise data obtained hourly at Arctic and Antarctic stations on eight .fixed frequencies between 51 kc and 20 Mc/s are analyzed to show the characteristics of the three types. The diurnal and seasonal variations of atmospheric radio noise at high latitudes are explainable in terms of changes in propagation factors and in the distribution of world thunderstorm activity. In both northern and southern Arctic regions atmospheric noise decreases during polar cap absorption (PCA), most markedly in the h.f. band. The probable magnitude of man-made noise in the h.f. band is estimated from data taken during PCA, when atmospheric noise is absent. At Thule man-made noise on 2.5 and 5 Mc/s appears to be 57 and 49 dB above kTB (where kTB is antenna thermal noise power), respectively, while at Byrd Station the values are about 20 and 12 dB respectively. Precipitation static is generated on exposed antennas during periods of blowing snow (blizzards). The noise power magnitude can be at least 50 dB above man-made and atmospheric levels, but the maximum enhancement cannot be ascertained because of missing data. In winter and spring months at Byrd Station radio data dependent upon exposed antennas may be lost 10-30 per cent of the time due to precipitation static alone.

Radio Noise↗

Quantifying Fractional Ground Cover on the Climate Sensitive High Plains Using AVIRIS and Landsat TM Data

The High Plains is an economically important and climatologically sensitive region of the United States and Canada. The High Plains contain 100,000 sq km of Holocene sand dunes and sand sheets that are currently stabilized by natural vegetation. Droughts and the larger threat of global warming are climate phenomena that could cause depletion of natural vegetation and make this region susceptible to sand dune reactivation. This thesis is part of a larger study that is assessing the effect of climate variability on the natural vegetation that covers the High Plains using Landsat 5 and Landsat 7 data. The question this thesis addresses is how can fractional vegetation cover be mapped with the Landsat instruments using linear spectral mixture analysis and to what accuracy. The method discussed in this thesis made use of a high spatial and spectral resolution sensor called AVIRIS (Airborne Visible and Infrared Imaging Spectrometer) and field measurements to test vegetation mapping in three Landsat 7 sub-scenes. Near-simultaneous AVIRIS images near Ft. Morgan, Colorado and near Logan, New Mexico were acquired on July 10, 1999 and September 30, 1999, respectively. The AVIRIS flights preceded Landsat 7 overpasses by approximately one hour. These data provided the opportunity to test spectral mixture algorithms with AVIRIS and to use these data to constrain the multispectral mixed pixels of Landsat 7. The comparisons of mixture analysis between the two instruments showed that AVIRIS endmembers can be used to unmix Landsat 7 data with good estimates of soil cover, and reasonable estimates of non-photosynthetic vegetation and green vegetation. Landsat 7 derived image endmembers correlate with AVIRIS fractions, but the error is relatively large and does not give a precise estimate of cover.

Warner, Amanda Susan↗

Effects of Deep Reductions in Energy Storage Costs on Highly Reliable Wind and Solar Electricity Systems.

We use 36 years (1980-2015) of hourly weather data over the contiguous United States (CONUS) to assess the impact of low-cost energy storage on highly reliable electricity systems that use only variable renewable energy (VRE; wind and solar photovoltaics). Even assuming perfect transmission of wind and solar generation aggregated over CONUS, energy storage costs would need to decrease several hundred-fold from current costs (to ~$1/kWh) in fully VRE electricity systems to yield highly reliable electricity without extensive curtailment of VRE generation. The role of energy storage changes from high-cost storage competing with curtailment to fill short-term gaps between VRE generation and hourly demand to near-free storage serving as seasonal storage for VRE resources. Energy storage faces "double penalties" in VRE/storage systems: with increasing capacity, (1) the additional storage is used less frequently and (2) hourly electricity costs would become less volatile, thus reducing price arbitrage opportunities for the additional storage.

14 SOLAR ENERGY↗

BOREAS HYD-1 Volumetric Soil Moisture Data

The Boreal Ecosystem-Atmosphere Study (BOREAS) Hydrology (HYD)-1 team made measurements of volumetric soil moisture at the Southern Study Area (SSA) and Northern Study Area (NSA) tower flux sites in 1994 and at selected tower flux sites in 1995-97. Different methods were used to collect these measurements, including neutron probe and manual and automated Time Domain Reflectometry (TDR). In 1994, the measurements were made every other day at the NSA-OJP (Old Jack Pine), NSA-YJP (Young Jack Pine), NSA-OBS (Old Black Spruce), NSA-Fen, SSA-OJP, SSA-YJP, SSA-Fen, SSA-YA (Young Aspen), and SSA-OBS sites. In 1995-97, when automated equipment was deployed at NSA-OJP, NSA-YJP, NSA-OBS, SSA-OBS, and SSA-OA (Old Aspen), the measurements were made as often as every hour. The data are stored in tabular ASCII files. The volumetric soil moisture data are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). The data files are available on a CD-ROM (see document number 20010000884).

Cuenca, Richard H.↗

Quantifying Interannual Variability for Photovoltaic Systems in PVWatts

The National Renewable Energy Laboratory's (NREL's) PVWatts is a relatively simple tool used by industry and individuals alike to easily estimate the amount of energy a photovoltaic (PV) system will produce throughout the course of a typical year. PVWatts Version 5 has previously been shown to be able to reasonably represent an operating system's output when provided with concurrent weather data, however this type of data is not available when estimating system output during future time frames. For this purpose PVWatts uses weather data from typical meteorological year (TMY) datasets which are available on the NREL website. The TMY files represent a statistically 'typical' year which by definition excludes anomalous weather patterns and as a result may not provide sufficient quantification of project risk to the financial community. It was therefore desired to quantify the interannual variability associated with TMY files in order to improve the understanding of risk associated with these projects. To begin to understand the interannual variability of a PV project, we simulated two archetypal PV system designs, which are common in the PV industry, in PVWatts using the NSRDB's 1961-1990 historical dataset. This dataset contains measured hourly weather data and spans the thirty years from 1961-1990 for 239 locations in the United States. To note, this historical dataset was used to compose the TMY2 dataset. Using the results of these simulations we computed several statistical metrics which may be of interest to the financial community and normalized the results with respect to the TMY energy prediction at each location, so that these results could be easily translated to similar systems. This report briefly describes the simulation process used and the statistical methodology employed for this project, but otherwise focuses mainly on a sample of our results. A short discussion of these results is also provided. It is our hope that this quantification of the interannual variability of PV systems will provide a starting point for variability considerations in future PV system designs and investigations. however this type of data is not available when estimating system output during future time frames.

14 SOLAR ENERGY↗

Is coverage a factor in non-Gaussianity of IMF parameters?

Recently, Feynman and Ruzmaikin (1994) showed that IMF parameters for the 1973 to 1990 period are not log-normally distributed as previously suggested by Burlaga and King (1979) for the data obtained over a shorter time period (1963-75). They studied the first four moments, namely: mean, variance, skewness, and kurtosis. For a Gaussian distribution, moments higher than the variance should vanish. In particular, Feynman and Ruzmaikin obtained very high values of kurtosis during some periods of their analysis. We note that the coverage for IMF parameters is very uneven for the period analyzed by them, ranging from less than 40% to greater than 80%. So a question arises as to whether the amount of coverage is a factor in their analysis. We decided to test this for the B(sub z) component of IMF, since it is an effective geoactive parameter for short term disturbances. Like them, we used 1-hour averaged data available on the Omnitape. We studied the scatter plots of the annual mean values of B(sub z)(nT) and its kurtosis versus the percent coverage for the year. We obtain a correlation coefficient of 0.48 and 0.42 respectively for the 1973-90 period. The probability for a chance occurrence of these correlation coefficients for 18 pair of points is less than 8%. As a rough measure of skewness, we determined the percent asymmetry between the areas of the histograms representing the distributions of the positive and the negative values of B(sub z) and studied its correlation with the coverage for the year. This analysis yields a correlation coefficient of 0.41 When we extended the analysis for the whole period for which IMF data are available (1963-93) the corresponding correlation coefficients are 0.59, 0.14, and 0.42. Our findings will be presented and discussed

Ahluwalia, H. S.↗

KCMP Minnesota Tall Tower Ammonia Observations and Emission Estimates Dataset 2017-2018

This data set contains NH3 mixing ratios, net ecosystem NH3 exchange, and supporting information measured at a tall tower (KCMP, 244 meter) site near St. Paul, Minnesota, USA. The data include NH3 and H2O mixing ratios measured at the 100 meter level, as well as NH3 mixing ratio measured at the 56 meter level. Wind data was measured using a sonic anemometer at the 185 meter level. Also included in this data set are values of wet N and NH3 deposition from 2016 - 2018. This data was collected to improve understanding of the ammonia and reactive nitrogen budget for the region.Ammonia mixing ratios were filtered for periods when the NH3 analyzer measured anomalous (i.e. 10 mmol mol-1) water vapor mixing ratios based on comparison with the IRGA (LI7000). Further, we filtered out NH3 observations obtained during strongly condensing conditions. These periods were identified when the water vapor mixing ratio differences between the 100 m and 56 m levels were more negative than -0.5 mmol mol-1 (i.e. when the water vapor gradient was strong and directed toward the land surface). Finally, we filtered out NH3 fluxes when the atmosphere was strongly stable (i.e. when (z-d)/L exceeded a value of +4.5) and subject to decoupling from the surface fluxes. Approximately 35.1% of the hourly flux data were either missing due to instrument failure or filtered according to the above quality control procedures.

54 ENVIRONMENTAL SCIENCES↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vegetation assessment using a combination of visible, near-IR, and thermal-IR AVHRR data

Twelve-hour temperature difference (thermal inertia) maps generated by rectifying and registering ascending (day) passes and descending (night) passes of the NOAA-7 Advanced Very High Resolution Radiometer (AVHRR) are compared to vegetation index maps generated from the visible and near IR data from the day pass of that satellite. There appears to be significant and unique information concerning surface characteristics in the temperature difference data on the 1-km scale of the AVHRR. A scatter diagram is provided which shows the pattern of day-night temperature difference compared to vegetation index for irrigated agriculture, dry rangeland, lakes, wet areas and burned rangeland. A detailed description of the techniques employed to provide the day-night temperature maps is provided.

Whitehead, V. S.↗

Partitioning evapotranspiration based on the concept of underlying water use efficiency

Evapotranspiration (ET) is dominated by transpiration (T) in the terrestrial water cycle. However, continuous measurement of transpiration is still difficult, and the effect of vegetation on ET partitioning is unclear. The concept of underlying water use efficiency (uWUE) was used to develop a new method for ET partitioning by assuming that the maximum, or the potential uWUE is related to T while the averaged or apparent uWUE is related to ET. T/ET was thus estimated as the ratio of the apparent over the potential uWUE using half-hourly flux data from 17 AmeriFlux sites. The estimated potential uWUE was shown to be essentially constant for 14 of the 17 sites, and was broadly consistent with the uWUE evaluated at the leaf scale. The annual T/ET was the highest for croplands, i.e., 0.69 for corn and 0.62 for soybean, followed by grasslands (0.60) and evergreen needle leaf forests (0.56), and was the lowest for deciduous broadleaf forests (0.52). The enhanced vegetation index (EVI) was shown to be significantly correlated with T/ET and could explain about 75% of the variation in T/ET among the 71 site-years. The coefficients of determination between EVI and T/ET were 0.84 and 0.82 for corn and soybean, respectively, and 0.77 for deciduous broadleaf forests and grasslands, but only 0.37 for evergreen needle leaf forests. This ET partitioning method is sound in principle and simple to apply in practice, and would enhance the value and role of global FLUXNET in estimating T/ET variations and monitoring ecosystem dynamics.

42 ENGINEERING↗

Renewable hydrogen and ammonia for combined heat and power systems in remote locations: Optimal design and scheduling

Abstract Using hydrogen (H ) and ammonia (NH ) for renewable energy storage has the potential to enable economical power and heat supply with high renewable penetrations, especially in remote locations which are characterized by high energy costs. In this work we assess the economic competitiveness of renewable combined heat and power (CHP) systems in Mahaka HI, Nantucket MA, and Northwest Arctic Borough (NWAB) AK by optimally designing these systems for scenarios in which power and heat can be purchased over a range of historical energy prices as well as when 100% renewable supply is required. We use a combined optimal design and scheduling model which minimizes annualized net present cost by determining optimal technology selection and size simultaneously with optimal schedules for each period of a system operating horizon aggregated from full year hourly resolution data via a consecutive temporal clustering algorithm. We find that renewable generation meets at least 85% of power demands and 75% of heat demands under the lowest energy prices investigated. Higher conventional energy prices lead to increased renewable penetration which is facilitated by renewable NH as a seasonal energy storage medium, as are 100% renewable CHP systems. NH is used for power generation with heat cogeneration in all three locations, as well as directly for heating in NWAB. On an annual cost basis, NH ‐enabled 100% renewable CHP is only 3% more expensive in Mahaka and NWAB than systems which can purchase energy at the lowest prices, while it is 15% more expensive in Nantucket.

Palys, Matthew J.↗

Using hydrogen and ammonia for renewable energy storage: A geographically comprehensive techno-economic study

Hydrogen and, more recently, ammonia have received worldwide attention as energy storage media. In this work we investigate the economics of using each of these chemicals as well as the two in combination for islanded renewable energy supply systems in 15 American cities representing different climate regions throughout the country. We use an optimal combined capacity planning and scheduling model which minimizes the levelized cost of energy (LCOE) by determining optimal unit selection and size along with unit commitments, production rates, and storage inventories for each period of system operation. These periods are aggregated from full year hourly resolution data via a consecutive temporal clustering algorithm. Ammonia is generally more economical than hydrogen as a single method of energy storage. Additionally, systems which use both hydrogen and ammonia outperform those which use only one storage option and have LCOE between $\$ 0.17$/kWh and $\$ 0.28$/kWh, including full investment in renewable generation infrastructure.

25 ENERGY STORAGE↗

Analysis of Lung Tumor Motion in a Large Sample: Patterns and Factors Influencing Precise Delineation of Internal Target Volume

Purpose/Objective: To evaluate lung tumor motion during respiration and to describe factors affecting the range and variability of motion in patients treated with stereotactic ablative radiation therapy. Methods and Materials: Log file analysis from online respiratory tumor tracking was performed in 145 patients. Geometric tumor location in the lungs, tumor volume and origin (primary or metastatic), sex, and tumor motion amplitudes in the superior-inferior (SI), latero-lateral (LL), and anterior-posterior (AP) directions were recorded. Tumor motion variability during treatment was described using intrafraction/interfraction amplitude variability and tumor motion baseline changes. Tumor movement dependent on the tumor volume, position and origin, and sex were evaluated using statistical regression and correlation analysis. Results: After analysis of >500 hours of data, the highest rates of motion amplitudes, intrafraction/interfraction variation, and tumor baseline changes were in the SI direction (6.0 ± 2.2 mm, 2.2 ± 1.8 mm, 1.1 ± 0.9 mm, and −0.1 ± 2.6 mm). The mean motion amplitudes in the lower/upper geometric halves of the lungs were significantly different (P<.001). Motion amplitudes >15 mm were observed only in the lower geometric quarter of the lungs. Higher tumor motion amplitudes generated higher intrafraction variations (R=.86, P<.001). Interfraction variations and baseline changes >3 mm indicated tumors contacting mediastinal structures or parietal pleura. On univariate analysis, neither sex nor tumor origin (primary vs metastatic) was an independent predictive factor of different movement patterns. Metastatic lesions in women, but not men, showed significantly higher mean amplitudes (P=.03) and variability (primary, 2.7 mm; metastatic, 4.9 mm; P=.002) than primary tumors. Conclusion: Online tracking showed significant irregularities in lung tumor movement during respiration. Motion amplitude was significantly lower in upper lobe tumors; higher interfraction amplitude variability indicated tumors in contact with mediastinal structures, although adhesion to parietal pleura did not necessarily reduce tumor motion amplitudes. The most variable lung tumors were metastatic lesions in women.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Review of particle deposition to and removal from clothing, skin, and hair after a radioactive airborne dispersal event

Explosive Radiological Dispersal Devices (RDD) – aka dirty bombs – are seen as a credible method to carry out a radiological terror attack. After exploding a radioactive source, the radionuclide-laden plume will be blown downwind of ground zero, with particles falling out and potentially depositing on people caught in and under the cloud. Some of these people may not show any sign of radiation sickness and therefore not realize they have been contaminated and may take the radioactive particulate with them on their daily activities, thus spreading the radioactive particulate outside the initially contaminated area. This paper reviews the scientific literature to better understand the rate at which particulate deposits on and is removed from the different “surfaces” of a person, i.e., hair, skin, and clothing. Prior research indicates that: 1) particle deposition is usually higher on skin than on hair and clothing; 2) particle deposition is greater for a person with higher skin moisture, 3) stronger wind increases the deposition flux onto a person, and 4) the fraction of particulate deposited on the hair, skin, and clothing respectively depends on the length of the hair, assuming all the hair surface is available for deposition. The studies taken into consideration show that the largest uncertainty in particulate deposition onto a person is due to clothing type because of the different possible weave arrangements and tightness which translate into differences in actual surface area and surface roughness. A factor of 2-to-20 variation in deposition rate was found. Removal of the particulate from the contaminated person may be due to wind, a person's movement, and/or contact transfer, i.e., by touching a different clean surface. Experiments show that the majority of the particulate is resuspended within 2–6 h mostly depending on the intensity of physical activity. The largest uncertainty in particulate removal from skin depends on the skin moisture, transfer rate of single-contact, and how many objects/people a person touches per hour. No data for hair were found for particle removal and resuspension. The studies considered did not utilize radionuclides directly; however, data on adhesion of radioactive vs. their non-radioactive counterpart have shown that the uncertainty due to the radioactivity of the particles is lower than that due to other factors. In conclusion, an idealized scenario involving a single building in the path of the cloud showed the impact of building-influenced flow on the cloud transport path and mixing, which affects the radiological dose the downwind population is exposed to and consequently the health effects.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Optimizing and Exploring Untapped Micro-Hydro Hybrid Systems: a Multi-Objective Approach for Crystal Lake as a Large-Scale Energy Storage Solution

Increasing electricity demand and concerns about climate change and fossil fuel consumption have highlighted the importance of renewable energy resources and storage systems. This paper proposes a method for exploring untapped pumped hydro storage potentials to accommodate intermittent renewable energy generation profiles. Hourly measured data from 2022 in Benzie County, Michigan, United States, were gathered for system sizing and a thorough, realistic analysis. By employing the multi-objective grey wolf optimization algorithm, we formulated optimal sizing and energy-management strategies for three different scenarios. Unlike similar studies, the 3rd with triple objective functions (OFs) scenario aims to maximize both reliability and ecological OFs while minimizing the cost OF. It has shown promising results with multiple solutions, considering economic, environmental, and reliability factors. A case study conducted in Crystal Lake, Michigan, revealed that although Crystal Lake would function only as a micro-hydro power facility, it is a promising and huge storage unit with a substantial storage capacity of around 14.9734GWh. The system investigated is significant in the USA due to its rapid deployment capabilities, minimal construction requirements, and ease of integration with the distribution grid. The fuzzy logic method was employed to identify the best non-dominant solution among the other solutions. Furthermore, these outcomes include a notably low levelized cost of energy at 0.046147$/kWh, a robust index of reliability of 99.705%, and a significant reduction in CO₂ emissions amounting to 7.9142×10 3 tons/year, when considering the triple OFs. The paper’s methodology provides valuable insights for regions aiming to utilize renewable energy from untapped storage sources.

13 HYDRO ENERGY↗

Urban microclimate and its impact on building performance: A case study of San Francisco

Urban microclimate exerts an increasing influence on urban buildings, energy, and sustainability. This study uses 10-year measured hourly weather data at 27 sites in San Francisco, California, to (1) analyze and visualize the urban microclimate patterns and urban heat island effect; (2) simulate annual energy use and peak electricity demand of typical large office buildings and large hotels to investigate the influence of urban microclimate on building performance; (3) simulate indoor air temperature of a single-family house without air-conditioning during the record three-day heatwave of 2017, to quantify the divergence of climate resilience due to urban microclimate effect. Results show significant microclimate effects in San Francisco with up to 11 °C outdoor air temperature difference between the coastal and downtown areas on September 1, 2017, during the record three-day heatwave. The simulated energy results of the prototype large office and large hotel buildings using the 2017 weather data show over 100% difference in annual heating energy use and 65% difference in annual cooling energy use across different stations; as well as up to 30% difference in peak cooling electricity demand. The impacts on annual site or source energy use are minimal (less than 5%) as cooling and heating in a mild climate are a relatively small portion of overall building energy use in San Francisco. Results also show the microclimate effects influence indoor air temperature of unconditioned homes by up to 5 °C. Newer buildings and homes are much less affected by microclimate effects due to more stringent performance requirements of the building envelope and energy systems. Furthermore, these findings inform that San Francisco microclimate variations should be considered in urban energy planning, building energy codes and standards, as well as heat resilience policymaking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Forest fire threatens global carbon sinks and population centres under rising atmospheric water demand

Levels of fire activity and severity that are unprecedented in the instrumental record have recently been observed in forested regions around the world. Using a large sample of daily fire events and hourly climate data, here we show that fire activity in all global forest biomes responds strongly and predictably to exceedance of thresholds in atmospheric water demand, as measured by maximum daily vapour pressure deficit. The climatology of vapour pressure deficit can therefore be reliably used to predict forest fire risk under projected future climates. We find that climate change is projected to lead to widespread increases in risk, with at least 30 additional days above critical thresholds for fire activity in forest biomes on every continent by 2100 under rising emissions scenarios. Escalating forest fire risk threatens catastrophic carbon losses in the Amazon and major population health impacts from wildfire smoke in south Asia and east Africa.

54 ENVIRONMENTAL SCIENCES↗

Multitasking information behavior, information task switching and anxiety: An exploratory study

Multitasking information behavior involves multiple forms of information searching such as library and Web search. Few researchers, however, have explored multitasking information behavior and information task switching in libraries in conjunction with psychological variables. This study explored this behavior in terms of anxiety under time pressure. This was an exploratory case study. Participant searched information for three unrelated everyday life information topics during a library visit, in a timeframe of one hour. The data collection tools used were: diary, observation, interview, and the State-Trait Anxiety Inventory test. Participant took the Trait-anxiety test before the library visit to measure anxiety level as a personal characteristic. She also took State-anxiety test before, during and after the library visit to measure anxiety levels regarding the information seeking behavior. The results suggested that participant had high levels of anxiety at the beginning of the multitasking information behavior. The reason for that was the concern about the performance as well as the identification of the right resources. During the multitasking information behavior, participant still had anxiety to find the right information. The levels of anxiety, however, were less due to library’s good organized structure. At the end of the information seeking process, the levels of anxiety dropped significant and therefore calm and safety returned. Finally, participant searched information for topics that were more important and for which she had prior knowledge When people, under time pressure, have access to well organized information, the levels of anxiety might decrease.

99 GENERAL AND MISCELLANEOUS↗