Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Biocompatible implants and methods of making and attaching the same

The invention provides a biocompatible silicone implant that can be securely affixed to living tissue through interaction with integral membrane proteins (integrins). A silicone article containing a laser-activated surface is utilized to make the implant. One example is an implantable prosthesis to treat blindness caused by outer retinal degenerative diseases. The device bypasses damaged photoreceptors and electrically stimulates the undamaged neurons of the retina. Electrical stimulation is achieved using a silicone microelectrode array (MEA). A safe, protein adhesive is used in attaching the MEA to the retinal surface and assist in alleviating focal pressure effects. Methods of making and attaching such implants are also provided.

60 APPLIED LIFE SCIENCES↗

Ion Implantation with in-situ Patterning for IBC Solar Cells

Interdigitated back-side Contact (IBC) solar cells are the highest efficiency silicon solar cells currently on the market. Unfortunately the cost to produce these solar cells is also very high, due to the large number of processing steps required. Varian believes that only the combination of high efficiency and low cost can meet the stated goal of $1/Wp. The core of this program has been to develop an in-situ patterning capability for an ion implantation system capable of producing patterned doped regions for IBC solar cells. Such a patterning capable ion implanter can reduce the number of process steps required to manufacture IBC cells, and therefore significantly reduce the cost. The present program was organized into three phases. Phase I was to select a patterning approach and determine the patterning requirements for IBC cells. Phase II consists of construction of a Beta ion implantation system containing in-situ patterning capability. Phase III consists of shipping and installation of the ion implant system in a customer factory where it will be tested and proven in a pilot production line.

14 SOLAR ENERGY↗

Silicon Quantum Dots with Counted Antimony Donor Implants

Deterministic control over the location and number of donors is crucial to donor spin quantum bits (qubits) in semiconductor based quantum computing. A focused ion beam is used to implant close to quantum dots. Ion detectors are integrated next to the quantum dots to sense the implants. The numbers of ions implanted can be counted to a precision of a single ion. Regular coulomb blockade is observed from the quantum dots. Charge offsets indicative of donor ionization, are observed in devices with counted implants.

Singh, Meenakshi↗

Implantable biomedical devices on bioresorbable substrates

Provided herein are implantable biomedical devices and methods of administering implantable biomedical devices, making implantable biomedical devices, and using implantable biomedical devices to actuate a target tissue or sense a parameter associated with the target tissue in a biological environment.

60 APPLIED LIFE SCIENCES↗

Wireless power transfer to biomedical implants

Various examples are provided for wireless power transfer to implants. In one example, a system includes a radio frequency (RF) power source and a transmitter (TX) array comprising an excitation coil and resonant coils distributed about the excitation coil. The TX array can transfer power from the RF power source to a biomedical implant inserted below a skin surface of a subject when the TX array is positioned on the skin surface adjacent to the biomedical implant. A receiver (RX) coil of the biomedical implant can inductively couple with the TX array for the power. The resonant coils can allow power transfer when the RX coil is not aligned with the excitation coil.

Lin, Jenshan↗

Wireless power transfer to biomedical implants

Various examples are provided for wireless power transfer to implants. In one example, a system includes a radio frequency (RF) power source and a transmitter (TX) array comprising an excitation coil and resonant coils distributed about the excitation coil. The TX array can transfer power from the RF power source to a biomedical implant inserted below a skin surface of a subject when the TX array is positioned on the skin surface adjacent to the biomedical implant. A receiver (RX) coil of the biomedical implant can inductively couple with the TX array for the power transfer. The resonant coils can allow power transfer when the RX coil is not aligned with the excitation coil.

Lin, Jenshan↗

Outgassing of implanted He via short circuit transport along phase and grain boundaries in vapor co-deposited Cu-W nanocomposites

We investigate the response of physical vapor co-deposited copper (Cu)-tungsten (W) nanocomposites to helium (He) implantation. Nuclear reaction analysis (NRA) reveals that a substantial fraction of He implanted into these materials escapes during implantation. Analysis of nanocomposite microstructure shows that the He loss is likely due to its transport out of the material by diffusion along phase and grain boundaries. Lastly, our findings suggest that solid-state interfaces such as phase and grain boundaries are short circuit diffusion pathways for transport of He.

36 MATERIALS SCIENCE↗

Process Performance of Optima XEx Single Wafer High Energy Implanter

To meet the process requirements for well formation in future CMOS memory production, high energy implanters require more robust angle, dose, and energy control while maintaining high productivity. The Optima XEx high energy implanter meets these requirements by integrating a traditional LINAC beamline with a robust single wafer handling system. To achieve beam angle control, Optima XEx can control both the horizontal and vertical beam angles to within 0.1 degrees using advanced beam angle measurement and correction. Accurate energy calibration and energy trim functions accelerate process matching by eliminating energy calibration errors. The large volume process chamber and UDC (upstream dose control) using faraday cups outside of the process chamber precisely control implant dose regardless of any chamber pressure increase due to PR (photoresist) outgassing. An optimized RF LINAC accelerator improves reliability and enables singly charged phosphorus and boron energies up to 1200 keV and 1500 keV respectively with higher beam currents. A new single wafer endstation combined with increased beam performance leads to overall increased productivity. We report on the advanced performance of Optima XEx observed during tool installation and volume production at an advanced memory fab.

43 PARTICLE ACCELERATORS↗

Radiation protection for high energy implantation of light ions in a production environment

In recent years the irradiation of semiconductor devices by light ions with high energies has increasingly become a well-established method to adjust charge carrier lifetimes in semiconductor devices. To introduce this process into the end of frontend production environment several measures in terms of radiation safety will have to be obeyed. An overview on thresholds for particles induced gamma emission will be given, starting with the {sup 11}B(p,{gamma}){sup 12}C reaction at 163keV. The environment has to be shielded from gamma rays, therefore those implanters have to be situated in adequate enclosures. Calculations for specific implant energies are done to define the thicknesses of tool enclosures. A set of radiation detectors monitors the values at well-defined positions online and radiation values are fed into a superordinate system that is directly coupled to the main power supply of the implanter.

36 MATERIALS SCIENCE↗

The Effects of Metallic Implants on Electroporation Therapies: Feasibility of Irreversible Electroporation for Brachytherapy Salvage

Purpose: Electroporation-based therapies deliver brief electric pulses into a targeted volume to destabilize cellular membranes. Nonthermal irreversible electroporation (IRE) provides focal ablation with effects dependent on the electric field distribution, which changes in heterogeneous environments. It should be determined if highly conductive metallic implants in targeted regions, such as radiotherapy brachytherapy seeds in prostate tissue, will alter treatment outcomes. Theoretical and experimental models determine the impact of prostate brachytherapy seeds on IRE treatments. Materials and Methods: This study delivered IRE pulses in nonanimal, as well as in ex vivo and in vivo tissue, with and in the absence of expired radiotherapy seeds. Electrical current was measured and lesion dimensions were examined macroscopically and with magnetic resonance imaging. Finite-element treatment simulations predicted the effects of brachytherapy seeds in the targeted region on electrical current, electric field, and temperature distributions. Results: There was no significant difference in electrical behavior in tissue containing a grid of expired radiotherapy seeds relative to those without seeds for nonanimal, ex vivo, and in vivo experiments (all p > 0.1). Numerical simulations predict no significant alteration of electric field or thermal effects (all p > 0.1). Histology showed cellular necrosis in the region near the electrodes and seeds within the ablation region; however, there were no seeds beyond the ablation margins. Conclusion: This study suggests that electroporation therapies can be implemented in regions containing small metallic implants without significant changes to electrical and thermal effects relative to use in tissue without the implants. This supports the ability to use IRE as a salvage therapy option for brachytherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nuclear Factor-κB is Activated in Filter-Implanted Vena Cava

Background: Implantation of a retrievable vena cava filter (VCF) is an effective method for preventing pulmonary embolism. Retrieval of filters, however, may be difficult due to intimal hyperplasia and inflammation in the cava wall. The transcription factor nuclear factor-kappaB (NF-κB) plays an important role in regulation of numerous genes participating in the inflammatory and proliferative responses of cells. The present study was to determine whether VCF implantation resulted in activation of NF-κB in the venous neointima. Methods: Filters were placed in vena cava (VC) in four swine for 30 days and then removed. Intimal specimens adhering to the filter struts were analyzed with reference to normal VC tissues. Immunohistochemical analyses were used to assess the NF-κB subunits p65 and p50 and the phosphorylated inhibitor of κB-α (phosphor-IκB-α) in the tissues. NF-κB DNA-binding activity was measured with enzyme-linked immunosorbent assay. Results: As compared to normal VC tissues, the intimal tissues contained higher percentages of cell nucleus-located p65 and p50, and NF-κB DNA-binding activity. Elevated immunoreactivities of p65, p50 and phosphor-IκB-α were also present in the intima. Conclusion: The present study demonstrates for the first time that VCF implantation caused NF-κB activation in neointima. We further demonstrate the activation is at least partly due to phosphorylation of IκB-α. Our data suggest that NF-κB activation would significantly contribute to development of intimal hyperplasia and inflammation in filter-inserted vena cava walls. NF-κB might be a therapeutic target for inhibiting filter-induced neointima and improving filter retrieval.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Ar Post-irradiations on Magnetic Properties of Cu-Implanted ZnO Single Crystals

Ar{sup +} post-irradiation effects on magnetic behavior of Cu{sup +}-implanted ZnO single crystals were studied. It was found that Cu{sup +}-implanted and Ar{sup +}-irradiated samples, even the primary sample, showed a magnetic moment (M{sub M}), but the saturation magnetization (M{sub S}) of Ar{sup +} post-irradiated on Cu{sup +} as-implanted one drastically decreased. Based on the first-principle method, it was drawn to the incomplete filling electronic configuration of the substituted Cu ion whose 3d orbital hybridized with O-2p contributing to the magnetism. The M{sub M} induced by the substituted Cu{sup +} ion was much less than that induced by the substituted Cu{sup 2+} and Cu{sup 3+} ion, so the ratio of Cu{sup 2+,3+}/Cu{sup +} decreased after Ar{sup +} post-irradiation, leading to the decrease of M{sub S}. The excessive concentration of O vacancy induced by post-irradiation also weakened the M{sub M} by their compensating electrons, and decreased the effective magnetic exchange coupling interaction. Cu-related clusters dissolution was also a critical reason for the reduction of M{sub S}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Defects in Arsenic Implanted р{sup +}–n- and n{sup +}–p- Structures Based on MBE Grown CdHgTe Films

Complex studies of the defect structure of arsenic-implanted (with the energy of 190 keV) Cd{sub x}Hg{sub 1–x}Te (x = 0.22) films grown by molecular-beam epitaxy are carried out. The investigations were performed using secondary-ion mass spectroscopy, transmission electron microscopy, optical reflection in the visible region of the spectrum, and electrical measurements. Radiation donor defects were studied in n{sup +}–p- and n{sup +}–n-structures obtained by implantation and formed on the basis of p-type and n-type materials, respectively, without activation annealing. It is shown that in the layer of the distribution of implanted ions, a layer of large extended defects with low density is formed in the near-surface region followed by a layer of smaller extended defects with larger density. A different character of accumulation of electrically active donor defects in the films with and without a protective graded-gap surface layer has been revealed. It is demonstrated that p{sup +}–n- structures are formed on the basis of n-type material upon activation of arsenic in the process of postimplantation thermal annealing with 100% activation of impurity and complete annihilation of radiation donor defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-temperature nuclear-detector arrays based on 4 H-SiC ion-implantation-doped p{sup +}-n junctions

Results obtained in a study of spectrometric characteristics of arrays of four detectors based on 4H-SiC ion-implantation-doped p{sup +}-n junctions in the temperature range 25-140 deg. C are reported for the first time. The junctions were fabricated by ion implantation of aluminum into epitaxial 4H-SiC layers of thickness {<=}45 {mu}m, grown by chemical vapor deposition with uncompensated donor concentration N{sub d} - N{sub a} = (4-6) x 10{sup 14} cm{sup -3}. The structural features of the ion-implantation-doped p{sup +}-layers were studied by secondary-ion mass spectrometry, transmission electron microscopy, and Rutherford backscattering spectroscopy in the channeling mode. Parameters of the diode arrays were determined by testing in air with natural-decay alpha particles with an energy of 3.76 MeV. The previously obtained data for similar single detectors were experimentally confirmed: the basic characteristics of the detector arrays, the charge collection efficiency and energy resolution, are improved as the working temperature increases.

36 MATERIALS SCIENCE↗

In vitro prominent bone regeneration by release zinc ion from Zn-modified implant

Highlights: {yields} We isolated the Zn{sup 2+} ions (eluted Zn{sup 2+} ion; EZ) from zinc-incorporated titanium implant. {yields} The EZ promoted the cell viability in hBMCs. {yields} The EZ stimulated preosteoblast and osteoblast marker gene expression in hBMCs. {yields} The hBMCs supplemented with EZ showed typically cell morphology when osteoblast maturing. {yields} It is revealed that the EZ also stimulates the calcium deposition of hBMCs. -- Abstract: Zinc is one of the trace elements which induce the proliferation and the differentiation of the osteoblast. In the previous study, we found that zinc ions (Zn{sup 2+} ion)-releasing titanium implants had excellent bone fixation using a rabbit femurs model. In this study, we isolated the Zn{sup 2+} ions (eluted Zn{sup 2+} ion; EZ) released from the implant surface, and evaluated the effect of EZ on the osteogenesis of human bone marrow-derived mesenchymal cells (hBMCs). In the result, it was found that the EZ stimulated cell viability, osteoblast marker gene (type I collagen, osteocalcin (OC), alkaline phosphatase (ALP) and bone sialoprotein (BSP)) expressions and calcium deposition in hBMCs.

60 APPLIED LIFE SCIENCES↗

Defect formation and bending properties in graphite under He atom implantation investigated by molecular dynamics method

The formation and evolution of radiation defects and their effects on bending property of a single graphite under low energy helium atom implantation have been studied at atomic scale through molecular dynamics simulations. Various simple interstitial and vacancy defects are observed during the implantation process, which is a function of incident energy and cross section of helium-carbon interaction. Large defects are observed after continuous helium atom implantations. The effects of incident energy on the density, size and distribution of defects are analyzed in detail. Furthermore, the kinetic evolution process of radiation defects at different annealing temperatures have also been simulated, including the migration, aggregation, transformation, coalescence, and self-healing. Here, the large defect clusters, crossing several carbon layers, have been confirmed to be the primary reasons that affect the bending property of graphite. All these results provide a new understanding for further applications of graphite in nuclear reactors.

Atomic implantation↗

Mastectomy With Immediate Expander-Implant Reconstruction, Adjuvant Chemotherapy, and Radiation for Stage II-III Breast Cancer: Treatment Intervals and Clinical Outcomes

Purpose: To determine intervals between surgery and adjuvant chemotherapy and radiation in patients treated with mastectomy with immediate expander-implant reconstruction, and to evaluate locoregional and distant control and overall survival in these patients. Methods and Materials: Between May 1996 and March 2004, 104 patients with Stage II-III breast cancer were routinely treated at our institution under the following algorithm: (1) definitive mastectomy with axillary lymph node dissection and immediate tissue expander placement, (2) tissue expansion during chemotherapy, (3) exchange of tissue expander for permanent implant, (4) radiation. Patient, disease, and treatment characteristics and clinical outcomes were retrospectively evaluated. Results: Median age was 45 years. Twenty-six percent of patients were Stage II and 74% Stage III. All received adjuvant chemotherapy. Estrogen receptor staining was positive in 77%, and 78% received hormone therapy. Radiation was delivered to the chest wall with daily 0.5-cm bolus and to the supraclavicular fossa. Median dose was 5040 cGy. Median interval from surgery to chemotherapy was 5 weeks, from completion of chemotherapy to exchange 4 weeks, and from exchange to radiation 4 weeks. Median interval from completion of chemotherapy to start of radiation was 8 weeks. Median follow-up was 64 months from date of mastectomy. The 5-year rate for locoregional disease control was 100%, for distant metastasis-free survival 90%, and for overall survival 96%. Conclusions: Mastectomy with immediate expander-implant reconstruction, adjuvant chemotherapy, and radiation results in a median interval of 8 weeks from completion of chemotherapy to initiation of radiation and seems to be associated with acceptable 5-year locoregional control, distant metastasis-free survival, and overall survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 125}I Monotherapy Using D90 Implant Doses of 180 Gy or Greater

Purpose: The purpose of this study was to characterize the oncologic results and toxicity profile of patients treated with {sup 125}I implants using the dose delivered to 90% of the gland from the dose-volume histogram (D90) of greater than 144 Gy. Methods and Materials: From June 1995 to Feb 2005, a total of 643 patients were treated with {sup 125}I monotherapy for T1-T2 prostate cancer with a D90 of 180 Gy or greater (median, 197 Gy; range, 180-267 Gy). Implantations were performed using a real-time ultrasound-guided seed-placement method and intraoperative dosimetry to optimize target coverage and homogeneity by using modified peripheral loading. We analyzed biochemical disease-free survival (bDFS) of 435 patients who had a minimum 2-year prostate-specific antigen follow-up (median follow-up, 6.7 years; range, 2.0-11.1 years). Results: Five-year bDFS rates for the entire cohort using the American Society for Therapeutic Radiology and Oncology and Phoenix definitions were 96.9% and 96.5%, respectively. Using the Phoenix definition, 5-year bDFS rates were 97.3% for low-risk patients and 92.8% for intermediate/high-risk patients. The positive biopsy rate was 4.1%. The freedom rate from Grade 2 or higher rectal bleeding at 5 years was 88.5%. Acute urinary retention occurred in 10.7%, more commonly in patients with high pretreatment International Prostate Symptom Scores (p < 0.01). In patients who were potent before treatment, 73.4% remained potent at 5 years after implantation. Conclusions: Patients with a minimum D90 of 180 Gy had outstanding local control based on prostate-specific antigen control and biopsy data. Toxicity profiles, particularly for long-term urinary and sexual function, were excellent and showed that D90 doses of 180 Gy or greater performed using the technique described were feasible and tolerable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗