Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERCONNECTED POWER SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Secondary Networks and Protection: Implications for DER and Microgrid Interconnection

Secondary networks are used to supply power to loads that require very high reliability and are in use around the world, particularly in dense urban downtown areas. The protection of secondary network systems poses unique challenges. The addition of distributed energy resources (DERs) to secondary networks can compound these challenges, and deployment of microgrids on secondary networks will create a new set of challenges and opportunities. This report discusses secondary networks and their protection, the challenges associated with interconnecting DERs to a secondary network, issues expected to be associated with creating microgrids on secondary networks, standards that deal with these challenges and issues, and suggestions for research and development foci that would yield new means for addressing these challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Transparent Framework for Evaluating the Effects of DGPV on Distribution System Costs

Assessing the costs and benefits of distributed photovoltaic generators (DGPV) to the power system and electricity consumers is key to determining appropriate policies, tariff designs, and power system upgrades for the modern grid. We advance understanding of this topic by providing a transparent framework, terminology, and data set for evaluating distribution system upgrade costs, line losses, and interconnection costs as a function of DGPV penetration level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Relaying for Distribution and Microgrids Evolving from Radial to Bidirectional Power Flow

As distributed energy resources (DERs) achieve higher penetration levels in distribution systems, the normal flow of power (and fault current) is no longer unidirectional, from substation source to load (or fault). The increased importance of DERs has also led to revisions in the DER interconnection standards, particularly voltage regulation and ride-through, with publication of a new IEEE Standard 1547 2018. These changes have complicated normal distribution system operation, and they will also complicate distribution system protection. The U.S. Department of Energy undertook a review of the protection state of the art for this new environment in order to identify gaps and propose near-term solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A High-Fidelity Electromagnetic Transient Model of Inverter-based Resources Integrated to an IEEE-9 Bus System for Benchmarking Studies

An inverter-based resource (IBR) is a source of electricity that is asynchronously connected to the electrical grid via an electronic power converter. These power sources lack the intrinsic behaviors of the standard power plants, presenting specific challenges to system stability. These power sources lack the intrinsic behaviors of the standards power plants and their features are almost entirely defined by the control strategy used on them, presenting specific challenges to system stability as their penetration increases into the already fragile Bulk Power System (BPS). Utilizing renewable energy has a great upside but the electrical industry needs to understand the requirements like performing electromagnetic transient (EMT) simulation studies in planning and/or in interconnection studies. This paper presents the development of a high-fidelity EMT model based on commercial equipment and field parameters, which at the same time aims to study the increasing penetration of IBRs and their impact on the actual BPS. The open-source EMT model developed will be a benchmarking example that can be used to evaluate algorithms in the power grid (including evaluating grid-forming controls, power system monitoring and operation, etc.).

Martinez Montejano, Misael↗

Management of Risk and Uncertainty Through Optimized Co-Operation of Transmission Systems and Microgrids With Responsive Loads (Final Report)

The evolution of the power system to the reliable, efficient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. Ambitious national and state-level goals around the decarbonization of electricity relies on the integration of very high levels of renewable resources, most of which are variable and intermittent. The use of demand response is an ideal approach to counterbalance the intermittency of renewable generation and brings the consumer into the spotlight. Though individual consumers are interconnected at the low-voltage distribution system, these resources are typically modeled as variables at the transmission network level. Demand-side participation cannot be leveraged effectively without explicitly including the distribution system dynamics in the optimization-based wholesale market operations. This project grew from a vision for co-optimized interaction of distribution systems, or microgrids, with the high-voltage transmission system. In this framework, microgrids encompass consumers, distributed renewables and storage. The energy management system of the lower voltage system (distribution or microgrid) can also sell (buy) excess (necessary) energy from the transmission system. Until recently, very little research had been conducted on the co-optimization of these two systems due to computational limitations. However, advances in computational capabilities, and the judicious use of decomposition methods and innovative approximation methods for high-dimension dynamic programming made this goal a viable objective for this project, leading to a fundamental shift in the ability to integrate and fully utilize demand-side resources. To this end, the modeling framework developed introduces a novel co-optimization framework, to include the operations of both the transmission and distribution systems (or microgrids) in operational decision making. This framework was used to analyze renewable and distributed generation along with responsive demand and to compare the capability of co-optimized systems to perform with higher levels of variable renewables. An ideal microgrid is defined as an electric entity capable of operating in both interconnected (with the high-voltage grid) and islanded mode. As such, the microgrid should incorporate generating units (traditional units and intermittent) and if needed, exchange power with the high-voltage grid. The interplay between the microgrid and high-voltage grid motivated the development of the co-optimization approach to ensure efficient performance of the interconnected network. Results show that the use of a bi-level optimization approach is an appropriate structure, capable of co-optimizing a transmission system with multiple distribution systems and microgrids. While increasing the number of connected systems provides increasing flexibility for renewables integration this can also the economic benefits to the low-voltage subsystems with each additional system connected. Comparison of a traditional single-level decision structure with the co-optimization approach illustrates a reduction in overall system cost under co-optimization, while specific cost allocations to transmission and distribution systems are changed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DOE Laboratory Support for DER and Inverter-Based Resource Integration Standards (ACCEL II) (Final Report)

This report documents efforts under a project that followed work completed under Accelerating Systems Integration Standards (ACCEL). In this continuation, the project team provided support for updates to critical standards for interconnection and interoperability of distributed energy resources at the distribution level. In addition, the project contributed to development of guidance for operational best practices of the bulk power system with high levels of DERs. Additional goals of the project were to inform and develop improved recommended practices and certification standards for end-to-end interoperability of DERs, utilizing Sandia laboratory assets when needed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flexibility Reserve Reductions from an Energy Imbalance Market with High Levels of Wind Energy in the Western Interconnection

The anticipated increase in variable generation in the Western Interconnection (WI) over the next several years has raised concerns about how to maintain system balance, especially in smaller Balancing Areas (BAs). Given renewable portfolio standards in the West, it is possible that more than 50 gigawatts (GW) of wind capacity will be installed by 2020. Significant quantities of solar generationare likely to be added as well. The consequent increase in variability and uncertainty that must be managed by the conventional generation fleet and responsive load make it attractive to consider ways in which Balancing Area Authorities (BAAs) can pool their variability and response resources, thus taking advantage of geographic and temporal diversity to increase overall operational efficiency.Our analysis considers several alternative forms of an Energy Imbalance Market (EIM) that have been proposed in the non-market areas of the WI. The proposed EIM includes two changes in operating practices that independently reduce variability and increase access to responsive resources: BAA cooperation and sub-hourly dispatch. As proposed, the EIM does not consider any form of coordinated unitcommitment; however, over time it is possible that BAAs would develop formal or informal coordination plans. This report examines the benefits of several possible EIM implementations, both separately and in concert.

17 WIND ENERGY↗

Development of an Innovative Inspection Tool for Superheater Tubes in Fossil Fuel Power Plants

Fossil fuel power plants are complex systems containing multiple components that require periodic health monitoring. Failures in these systems can lead to increased downtime for the plant, reduction of power, and significant cost for repairs. Inspections of the plant’s superheater tubes are typically manual, laborious, and extremely time-consuming. This is due to their small diameter size (between 1.3 and 7.6 cm) and the coiled structure of the tubing. In addition, the tubes are often stacked close to each other, limiting access for external inspection. This paper presents the development and testing of an electrically powered pipe crawler that can navigate inside 5 cm diameter tubes and provide an assessment of their health. The crawler utilizes peristaltic motion within the tubes via interconnected modules for gripping and extending. The modular nature of the system allows it to traverse through straight sections and multiple 90° and 180° bends. Additional modules in the system include an ultrasonic sensor for tube thickness measurements, as well as environmental sensors, a light detecting and ranging (LiDAR) sensor, and camera. Furthermore, these modules utilize a gear system that allows for 360° rotation and provides a means to inspect the entire internal circumference of the tubes.

36 MATERIALS SCIENCE↗

Nuclear-renewable hybrid energy systems: Opportunities, interconnections, and needs

As the U.S. energy system evolves, the amount of electricity from variable-generation sources is likely to increase, which could result in additional times when electricity demand is lower than available production. Thus, purveyors of technologies that traditionally have provided base-load electricity—such as nuclear power plants—can explore new operating procedures to deal with the associated market signals. Concurrently, innovations in nuclear reactor design coupled with sophisticated control systems now allow for more complex apportionment of heat within an integrated system such as one linked to energy-intensive chemical processes. This paper explores one opportunity – nuclear-renewable hybrid energy systems. These are defined as integrated facilities comprised of nuclear reactors, renewable energy generation, and industrial processes that can simultaneously address the need for grid flexibility, greenhouse gas emission reductions, and optimal use of investment capital. Six aspects of interaction (interconnections) between elements of nuclear-renewable hybrid energy systems are identified: Thermal, electrical, chemical, hydrogen, mechanical, and information. Additionally, system-level aspects affect selection, design, and operation of this hybrid system type. Throughout the paper, gaps and research needs are identified to promote further exploration of the topic.

30 DIRECT ENERGY CONVERSION↗

Cayuga County Regional Digester: Vision Becomes Reality. Final Report

With an average herd size of 113 mature cows, Cayuga County is home to 280 dairy farms and 31,500 dairy milking cows producing approximately 855 million gallons of milk per year. The Cayuga Dairy industry is a major contributor to the countys economy, employing nearly 1200 people, while generating $140,000,000 of revenue from sale of milk alone. At the same time, the Cayuga County dairy industry also produces 5.7 million gallons of manure daily: (a) Nearly 34% of this manure is produced on smaller farms. (b) Digesters are expensive pieces of equipment and require attention and care. ( c) The on-farm digester systems have fairly long payback (>10 years) even for larger CAFO farms (>1000 milking cows). In 2005, Cayuga County Soil and Water Conservation District (The District), a Public Agency under Cayuga County, decided to undertake a centralized community digester project. The primary goal of the project was to develop an economically sustainable model, under the auspices of The District to address manure management issues facing the smaller dairies, improve the water quality and improve the quality of life for Cayuga County residents. It is believed that the District has accomplished this goal by completing construction of Cayuga County Regional Digester on a parcel of land behind the Cayuga County Natural Resource Center located at 7413 County House Road in the Town of Sennett in Cayuga County, New York. The digester facility consists of the following major components. 1. Transfer Station: This an indoor truck bay, where 35,000 gallons of manure from three local farms, 8,500 gallons of liquid organic food-processor waste, and 1,200 gallons of brown grease are unloaded from tanker trucks and the digested slurry is loaded onto the tanker trucks for delivery back to the participating farms. 2. Anaerobic Digester: The project utilizes a hydraulic mix anaerobic digester, a unique design that has no internal moving parts for mixing. The digester, which operates at mesophilic temperatures, is designed to process the daily feedstock and produce 220,000 SCF2 of biogas per day. The digester also produces 44,000 gallons of digested slurry per day. 3. Biogas Conditioning System: The plant employs a biological biogas conditioning system to remove the H2S and moisture contents of the biogas and prepare it to be used by the plant generation system. 4. Combined Heat and Power System (CHP): This is a 633kW high efficiency biogas-fired GE-Jenbacher model JMS-312 GS-NL reciprocating engine cogeneration system. The heat recovery system incorporated into the package is designed to capture the waste heat from the engine exhaust, the jacket cooling water and the engine oil circuit. 5. Electrical Substation and Power Distribution Systems: An electrical distribution system has been constructed on-site that aggregates the electrical service of the different county buildings on the District campus into a county owned electric distribution system that is interconnected with the CHP and the local electric grid. The electrical system is designed, in accordance with the utility guidelines, to allow grid-parallel operation of CHP and provide for import and export of electric power. 6. Thermal Energy Distribution System: The heat recovery system has been integrated into a high temperature water distribution system that distributes the heat to the thermal circuits for the anaerobic digester facility. Additional piping has also been installed to transfer the remaining thermal energy to other county buildings on the campus. On a daily basis, the plant will co-process 35,000 gallons of manure from local dairy farms, 8,500 gallons of food-processor waste and 1,200 gallons of brown grease to produce 200,000 ft3/d of biogas and 44,000 gallons of pathogen-free nutrient-rich digested slurry for agricultural use by farms and in the local area.The biogas fueled CHP produces 5,157,000 kWh of electricity and 19,506 dekatherms of thermal energy per year. Electrical power generated by the cogeneration system powers all the buildings on the Cayuga County campus and any surplus power is exported to the grid under a power purchase agreement. Heat recovered from the cogeneration system will be used to maintain the temperature of the process equipment and the excess will be transported to the Cayuga County Public Safety Building to offset purchase of fossil fuel to fuel the boilers. The majority of plant operations are unmanned and automated. However, the plant will have a small staff of well-trained personnel to coordinate the feedstock deliveries and shipments, supervise the day-to-day operation, monitor the systems and perform maintenance, maintain a safe and reliable operation and to respond to emergencies.

09 BIOMASS FUELS↗

Market analysis for the integration of new power technologies: A case study of the deployment of hybrid fossil-based generator plus energy storage (ES-FE)

This study examines the national landscape of hybridized fossil energy (FE) power plants with energy storage (ES) technologies (“ES-FE”) and presents the compilation of an ES-FE dataset, which includes over 65 ES-FE projects and concepts in the United States, comprising approximately 500 MWh of co-located ES capacity with FE power plants. This study also estimates the economic feasibility of adding ES to existing FE power plants by characterizing the potential revenues that can be generated by the ES component through flexibility and capacity value. The analysis focuses on ES technologies with 2- to 10-h. durations located in four U.S. independent system operators (ISOs): Midcontinent ISO (MISO), Electric Reliability Council of Texas (ERCOT), PJM Interconnection (PJM), and California ISO (CAISO), which have +70,000 MW of combined FE power capacity that could add ES. Annual revenues are estimated for the ES component using a what-if-analysis approach, for capacity value, price arbitrage, or ancillary services provision. The results show that annual revenues depend on the end-use storage service, wholesale electricity and capacity market prices, and ES technology operation parameters such as discharging duration and cycling frequency. When performing a sensitivity analysis, ES accrues $7–178/kW-yr. via price arbitrage and ancillary services provision in the four ISOs, and $13–92/kW-yr. when providing capacity value only in MISO and PJM. A cash flow analysis is performed to estimate the net present value (NPV) of the ES addition using a range of ES costs. The study finds that for most ES technologies considered, these revenues alone are insufficient to achieve economic feasibility. In conclusion, of the 1645 total runs analyzed, 115 had positive NPVs (7%). Therefore, other revenue streams or monetizable benefits are necessary to achieve the break-even point.

20 FOSSIL-FUELED POWER PLANTS↗

Evaluating advanced nuclear fission technologies for future decarbonized power grids

Advanced nuclear fission, which encompasses various innovative nuclear reactor designs, could contribute to the decarbonization of the United States electricity sector. However, little is known about how cost-competitive these reactors would be compared to other technologies, or about which aspects of their designs offer the most value to a decarbonized power grid. We employ an electricity system optimization model and a case study of a decarbonized U.S. Eastern Interconnection circa 2050 to generate initial indicators of future economic value for advanced reactors and the sensitivity of future value to various design parameters, the availability of competing technologies, and the underlying policy environment. These results can inform long-term cost targets and guide near-term innovation priorities, investments, and reactor design decisions. We find that advanced reactors should cost $\$5.7$–$\$7.3$/W to gain an initial market share (assuming 30 year asset life and 3.5 %–6.5 % real weighted average cost of capital), while those that include thermal storage in their designs can cost up to $\$6.0$/W–$\$7.7$/W (not including cost of storage). Since the marginal value of advanced fission reactors declines as market penetration increases, break-even costs fall ~32 % at 100 GW of cumulative capacity and ~51 % at 300 GW. Additionally, policies that provide investment tax credits for nuclear energy create the most favorable environment for advanced nuclear fission. In conclusion, these findings can inform near-term resource allocation decisions by stakeholders, innovators and investors working in the energy technology sector.

Capacity expansion↗

High-Penetration Photovoltaics Standards and Codes Workshop, Denver, Colorado, May 20, 2010: Workshop Proceedings

Effectively interconnecting high-level penetration of photovoltaic (PV) systems requires careful technical attention to ensuring compatibility with electric power systems. Standards, codes, and implementation have been cited as major impediments to widespread use of PV within electric power systems. On May 20, 2010, in Denver, Colorado, the National Renewable Energy Laboratory, in conjunctionwith the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE), held a workshop to examine the key technical issues and barriers associated with high PV penetration levels with an emphasis on codes and standards. This workshop included building upon results of the High Penetration of Photovoltaic (PV) Systems into the Distribution Grid workshop held in OntarioCalifornia on February 24-25, 2009, and upon the stimulating presentations of the diverse stakeholder presentations.

14 SOLAR ENERGY↗

DC-connected Solar Plus Storage Modeling and Analysis for Behind-The-Meter Systems in the System Advisor Model: Preprint

A detailed model for PV plus DC-connected batteries was developed. This model was compared to an existing AC connected battery model in the System Advisor Model (SAM) tool using a hypothetical Honolulu residence with a PV plus storage system. The stand-alone PV system was shown to provide the most value; however due to the increased difficulty of PV systems being approved for grid interconnection in Hawaii, it is valuable to install an AC or DC connected battery to enable full PV self-consumption under a less restrictive interconnection option. In that case both battery systems enabled full PV self consumption at the residence, requiring no power to be exported to the grid. The DC-connected battery system captured energy from the PV array which would have also been clipped due to inverter limitations. For a PV system with DC/AC ratio of 1.23, the battery configurations produced net-present values within 1% of each other, but when the DC/AC ratio increased to 1.85, the DC-connected system increased the net-present value by 13%.

14 SOLAR ENERGY↗

Multiple stack fuel cell system

A fuel cell system is disclosed comprising a plurality of fuel cell modules including a sealed planar fuel cell stack, the stack including internal manifold channels for transport of fuel and air to fuel cells within the stack and transport of tail gas and spent air away from fuel cells within the stack. Each of the fuel cell stacks is mounted on a stack footprint area of a top member of a base manifold. The base manifolds are configured to allow for interconnection of a number of fuel cell stack modules to provide a fuel cell system capable of producing power outputs that otherwise would have required large surface area cells or stack with a large number of cells.

Haltiner, Jr., Karl J.↗

DC-Connected Solar Plus Storage Modeling for Behind-the-Meter Systems in SAM

A detailed model for PV plus DC-connected batteries was developed. This model was compared to an existing AC connected battery model in the System Advisor Model (SAM) tool using a hypothetical Honolulu residence with a PV plus storage system. The stand-alone PV system was shown to provide the most value; however due to the increased difficulty of PV systems being approved for grid interconnection in Hawaii, it is valuable to install an AC or DC connected battery to enable full PV self-consumption under a less restrictive interconnection option. In that case both battery systems enabled full PV self consumption at the residence, requiring no power to be exported to the grid. The DC-connected battery system captured energy from the PV array which would have also been clipped due to inverter limitations. For a PV system with DC/AC ratio of 1.23, the battery configurations produced net-present values within 1% of each other, but when the DC/AC ratio increased to 1.85, the DC-connected system increased the net-present value by 13%.

14 SOLAR ENERGY↗

Architecture for Web-Based Visualization of Large-Scale Energy Domains: Preprint

With the growing penetration of inverter-based distributed energy resources and increased loads through electrification, power systems analyses are becoming more important and more complex. Moreover, these analyses increasingly involve the combination of interconnected energy domains with data that are spatially and temporally increasing in scale by orders of magnitude, surpassing the capabilities of many existing analysis and decision-support systems. We present the architectural design, development, and application of a high-resolution web-based visualization environment capable of cross-domain analysis of tens of millions of energy assets, focusing on scalability and performance. Our system supports the exploration, navigation, and analysis of large data from diverse domains such as electrical transmission and distribution systems, mobility and electric vehicle charging networks, communications networks, cyber assets, and other supporting infrastructure. We evaluate this system across multiple use cases, describing the capabilities and limitations of a web-based approach for high-resolution energy system visualizations.

grid modernization↗

Mississippi State University Cooling, Heating, and Power (Micro-CHP) and Bio-Fuel Center

Between 2008 and 2014, the U.S. Department of Energy funded the MSU Micro-CHP and Bio-Fuel Center located at Mississippi State University. The overall objective of this project was to enable micro-CHP (micro-combined heat and power) utilization, to facilitate and promote the use of CHP systems and to educate architects, engineers, and agricultural producers and scientists on the benefits of CHP systems. Therefore, the work of the Center focused on the three areas: CHP system modeling and optimization, outreach, and research. In general, the results obtained from this project demonstrated that CHP systems are attractive because they can provide energy, environmental, and economic benefits. Some of these benefits include the potential to reduce operational cost, carbon dioxide emissions, primary energy consumption, and power reliability during electric grid disruptions. The knowledge disseminated in numerous journal and conference papers from the outcomes of this project is beneficial to engineers, architects, agricultural producers, scientists and the public in general who are interested in CHP technology and applications. In addition, more than 48 graduate students and 23 undergraduate students, benefited from the training and research performed in the MSU Micro-CHP and Bio-Fuel Center. The project scope consisted of six separate, but related areas: 1. Micro-CHP modeling - Computational simulations and verification/validation studies of selected models for technical and economic viability. 2. Fuel flexibility in micro-CHP applications – Demonstrating and quantifying the operation of micro-CHP systems on alternative fuels. 3. Outreach activities – Providing provide educational materials for engineers and architects and conducting outreach seminars, workshops, and demonstrations for engineers and architects as well as for more general audiences. 4. Biofuel and opportunity fuel processing and utilization – Determining the processing requirements and feasibility to utilize biofuels and disaster debris for micro-CHP systems. 5. CHP Systems Optimization – Optimization of internal combustion and Stirling engines integrated with heat recovery systems for CHP operation. 6. Distributed Generation and Grid Interconnection – Developing requirements and control systems for interconnection of micro-CHP systems with the electrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗