AE and DE mass spectrometer observations relevant to the shuttle glow

Recent work suggested that NO2 may be responsible for the observed continuum glow near surfaces of the space shuttle. The observations of atomic nitrogen (N) are reported at shuttle altitudes using mass spectrometers, giving special attention to the surface reactions of N relevant to the production of NO2 on spacecraft surfaces. Data from two semi-open sources mass spectrometers, the OSS instruments on the Atmosphere Explorer-C and -D satellites, and the closed source Neutral Atmospheric Composition Spectrometer (NACS) on the Dynamic Explorer-2 satellite are presented to show the similar behavior of NO in each case and the contrasting behavior of NO2. Although signals of NO and NO2 are highly dependent on surface temperature and surface composition, it appears that direct exposure of ion source surfaces to rammed gas is a necessary condition for the production of large amounts of NO2. Evidence that elevated surface temperatures can significantly reduce the production of NO2, likely by causing more rapid desorption of NO from these surfaces, is presented.

Engebretson, M. J.↗

Proton-bound cluster ions in ion mobility spectrometry

Gaseous oxygen and nitrogen bases, both singly and as binary mixtures, have been introduced into ion mobility spectrometers to study the appearance of protonated molecules, and proton-bound dimers and trimers. At ambient temperature it was possible to simultaneously observe, following the introduction of molecule A, comparable intensities of peaks ascribable to the reactant ion (H2O)nH+, the protonated molecule AH+ and AH+ H2O, and the symmetrical proton bound dimer A2H+. Mass spectral identification confirmed the identifications and also showed that the majority of the protonated molecules were hydrated and that the proton-bound dimers were hydrated to a much lesser extent. No significant peaks ascribable to proton-bound trimers were obtained no matter how high the sample concentration. Binary mixtures containing molecules A and B, in some cases gave not only the peaks unique to the individual compounds but also peaks due to asymmetrical proton bound dimers AHB+. Such ions were always present in the spectra of mixtures of oxygen bases but were not observed for several mixtures of oxygen and nitrogen bases. The dimers, which were not observable, notable for their low hydrogen bond strengths, must have decomposed in their passage from the ion source to the detector, i.e. in a time less than approximately 5 ms. When the temperature was lowered to -20 degrees C, trimers, both homogeneous and mixed, were observed with mixtures of alcohols. The importance of hydrogen bond energy, and hence operating temperature, in determining the degree of solvation of the ions that will be observed in an ion mobility spectrometer is stressed. The possibility is discussed that a displacement reaction involving ambient water plays a role in the dissociation.

Non-NASA Center↗

The Wind and Temperature Spectrometer (WTS) in the Atmospheric Neutral Density Experiment (ANDE) Satellite

Miniaturization efforts in new spectrometers for ionosphere/thermosphere investigations of the ion-drifts and neutral winds and corresponding temperatures make possible very light (about 250 g) packages consuming less than 0.4 W. Previously described, our approach measures the angular and energy distributions of neutral atoms and molecules (or ions) in two perpendicular planes; using those distributions to determine the full wind vector, the temperature and the relative densities of O and N2, as required for the ANDE mission. The measurements require two separate electron impact ion sources each with its own electron beam cathode. We have developed a low-temperature thermionic emission cathode that delivers 1 mA electron current at 80 mW power, making it possible to operate neutral wind-temperature experiments for the first time with powers less than 0.5 W. Advances in the ion optics of the energy-angle spectrometer enhance the energy resolution-aperture product more than a factor of 3 to enable energy resolutions of a few percent with large apertures. With these technology improvements it is now possible to obtain the full neutral wind vector, temperature and O/N2, density ratio once per second in a 250g/0.4W package with sensitivity up to about 500 km altitude in the thermosphere. We will describe the WTS as deployed in ANDE and show simulated data with the non-linear least squares analysis to illustrate expected performance of the WTS in the estimated errors in the three components of the wind, the temperature, and the relative densities.

Herrero, F. A.↗

Atomic nitrogen measurements in the upper atmosphere

The open-source neutral mass spectrometer (OSS) on the Atmosphere Explorer-C satellite (AE-C) measures the neutral constituents of the upper atmosphere. It has been found that atomic nitrogen densities can be determined at altitudes above 380 km. Most of the nitrogen atoms combine with oxygen adsorbed on the walls of the ion source to form NO. The measured net peaks at 14 amu and 30 amu show the scale height expected for atomic nitrogen; both peaks have a pronounced diurnal variation. Absolute number densities at 400 km are computed for a time period between February and April 1974 when measurements were taken in the northern hemisphere. Minimum and maximum densities of atomic nitrogen occur between 4 and 6 hr LST in the morning and around 16 hr LST in the afternoon, respectively. At 400 km, the minimum particle density is 100,000/cu cm and the maximum density 1.5 million/cu cm. In contrast to the response of N2 to geomagnetic activity, atomic N shows no appreciable effect.

Mauersberger, K.↗

The Neutral Gas and Ion Mass Spectrometer on the Mars Atmosphere and Volatile Evolution Mission

The Neutral Gas and Ion Mass Spectrometer (NGIMS) of the Mars Atmosphere and Volatile Evolution Mission (MAVEN) is designed to measure the composition, structure, and variability of the upper atmosphere of Mars. The NGIMS complements two other instrument packages on the MAVEN spacecraft designed to characterize the neutral upper atmosphere and ionosphere of Mars and the solar wind input to this region of the atmosphere. The combined measurement set is designed to quantify atmosphere escape rates and provide input to models of the evolution of the martian atmosphere. The NGIMS is designed to measure both surface reactive and inert neutral species and ambient ions along the spacecraft track over the 125-500 km altitude region utilizing a dual ion source and a quadrupole analyzer.

Gas↗

Correlated characterization of 20 Ne-implanted targets using nuclear reaction analysis, Rutherford backscattering spectrometry, and ion transport modeling

In this article, we present the preparation and characterization of a large sample of implanted noble gas targets for use in precision nuclear astrophysics measurements with intense proton beams. Tantalum and titanium backings were prepared using wet-acid etching, outgassed via resistive heating, and implanted with 20 Ne + beams from differing ion sources. These experimental targets were investigated using both nuclear reaction analysis techniques on the 1169-keV resonance in 20 Ne(p, $\gamma$) 21 Na and Rutherford backscattering spectrometry analysis with 2-MeV α-particle beams. Results from these analyses reveal small target-to-target variations in stoichiometry, while exhibiting excellent agreement independent of ion-beam analysis method. We also present a self-consistent validation of the nuclear reaction analysis results using ion transport simulations in TRIM-2013 that rely on input parameters from SIMNRA scattering-yield fits to Rutherford backscattering spectra. In addition to a complete description of the implantation profile, this analysis method provides an alternate solution for characterizing a large sample of implanted targets when no suitable resonances are available for nuclear reaction analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An integrated development facility for the calibration of low-energy charged particle flight instrumentation

A system was developed for the calibration and development of thermal ion instrumentation. The system provides an extended beam with usable current rates, approx. 1 pA/sq cm, at beam energies as low as 1 eV, with much higher values available with increasing energy. A tandem electrostatic and variable geometry magnetic mirror configuration within the ion source optimizes the use of the ionizing electrons. The system is integrated under microcomputer control to allow automatic control and monitoring of the beam energy and composition and the mass and angle-dependent response of the instrument under test. The system is pumped by a combination of carbon vane and cryogenic sorption roughing pumps and ion and liquid helium operating pumps.

Biddle, A. P.↗

Ion acceleration from microstructured targets irradiated by high-intensity picosecond laser pulses

Structures on the front surface of thin foil targets for laser-driven ion acceleration have been proposed to increase the ion source maximum energy and conversion efficiency. While structures have been shown to significantly boost the proton acceleration from pulses of moderate-energy fluence, their performance on tightly focused and high-energy lasers remains unclear. Here, we report the results of laser-driven three-dimensional (3D)-printed microtube targets, focusing on their efficacy for ion acceleration. Using the high-contrast (~10 12) PHELIX laser (150 J, 10 21 W / cm 2 ), we studied the acceleration of ions from 1-μm-thick foils covered with micropillars or microtubes, which we compared with flat foils. The front-surface structures significantly increased the conversion efficiency from laser to light ions, with up to a factor of 5 higher proton number with respect to a flat target, albeit without an increase of the cutoff energy. An optimum diameter was found for the microtube targets. Our findings in this work are supported by a systematic particle-in-cell modeling investigation of ion acceleration using 2D simulations with various structure dimensions. Simulations reproduce the experimental data with good agreement, including the observation of the optimum tube diameter, and reveal that the laser is shuttered by the plasma filling the tubes, explaining why the ion cutoff energy was not increased in this regime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated development facility for the calibration of low-energy charged particle flight instrumentation

The design of a low-energy ion facility for development and calibration of thermal ion instrumentation is examined. A directly heated cathode provides the electrons used to produce ions by impact ionization and an applied magnetic field increases the path length followed by the electrons. The electrostatic and variable geometry magnetic mirror configuration in the ion source is studied. The procedures for the charge neutralization of the beam and the configuration and function of the 1.4-m drift tube are analyzed. A microcomputer is utilized to control and monitor the beam energy and composition, and the mass- and angle-dependent response of the instrument under testing. The facility produces a high-quality ion beam with an adjustable range of energies up to 150 eV; the angular divergence and uniformity of the beam is obtained from two independent retarding potential analyzers. The procedures for calibrating the instrument being developed are described.

Biddle, A. P.↗

Development of an in situ ion irradiation scanning electron microscope

An in situ ion irradiation scanning electron microscope (I 3 SEM) has been developed, installed, and integrated into the Ion Beam Laboratory at Sandia National Laboratories. The I 3 SEM facility combines a field emission, variable pressure, scanning electron microscope, a 6 MV tandem accelerator, high flux low energy ion source, an 808 nm-wavelength laser, and multiple stages to control the thermal and mechanical state of the sample observed. The facility advances real-time understanding of materials evolution under combined environments at the mesoscale. As highlighted in multiple examples, this unique combination of tools is optimized for studying mesoscale material response in overlapping extreme environments, allowing for simultaneous ion irradiation, implantation, laser bombardment, conductive heating, cooling, and mechanical deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of laser-target parameters for the production of stable lithium beam

A laser ion source coupled with a radio frequency quadrupole linac accelerator is being proposed as a suitable system for the production of a low energy, high-current stable lithium beam. In order to maximize the lithium yield, plasmas generated by laser ablation of different materials based on lithium (Li, LiOH, and LiNbO3) have been characterized by using a Faraday cup and an electrostatic ion analyzer in the time of flight configuration. A wide range of laser power density has been investigated (109–1012 W/cm2) using two Nd:YAG lasers operating at different wavelengths (1064 nm and 532 nm), pulse durations (6 ns and 17 ns), and maximum energies (1400 mJ and 210 mJ). This paper outlines the pros and cons of the investigated materials by studying how the ion energy, yields, and charge state distributions are modified when the laser power density is changed. Considerable attention has been paid to the higher charge states of oxygen, which may occur with the same mass-to-charge ratio of Li3+. The analysis has evidenced that LiNbO3 represents a valid target since it allows minimizing the O6+/7Li3+ ratio down to 2.5% by using a laser power density of 1.8 × 1010 W/cm2. For such a condition, a Li3+ current of 1.4 mA/cm2 has been measured.

Cannavò, A. (ORCID:0000000309759630)↗

Direct Write of 3D Nanoscale Mesh Objects with Platinum Precursor via Focused Helium Ion Beam Induced Deposition

The next generation optical, electronic, biological, and sensing devices as well as platforms will inevitably extend their architecture into the 3rd dimension to enhance functionality. In focused ion beam induced deposition (FIBID), a helium gas field ion source can be used with an organometallic precursor gas to fabricate nanoscale structures in 3D with high-precision and smaller critical dimensions than focused electron beam induced deposition (FEBID), traditional liquid metal source FIBID, or other additive manufacturing technology. In this work, we report the effect of beam current, dwell time, and pixel pitch on the resultant segment and angle growth for nanoscale 3D mesh objects. We note subtle beam heating effects, which impact the segment angle and the feature size. Additionally, we investigate the competition of material deposition and sputtering during the 3D FIBID process, with helium ion microscopy experiments and Monte Carlo simulations. Our results show complex 3D mesh structures measuring ~300 nm in the largest dimension, with individual features as small as 16 nm at full width half maximum (FWHM). These assemblies can be completed in minutes, with the underlying fabrication technology compatible with existing lithographic techniques, suggesting a higher-throughput pathway to integrating FIBID with established nanofabrication techniques.

36 MATERIALS SCIENCE↗

Development Towards Stable Chlorine Isotope Measurements of Astromaterials Using the Modified Middleton Source of an Accelerator Mass Spectrometer

The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35Cl and 37Cl. Chlorine isotope variations (reported as δ37Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) are documented to exceed 80‰ between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history. The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements. This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ37Cl measurements using the modified Middleton ion source of an existing accelerator mass spectrometer. For samples with as little as 1 μg Cl–the equivalent of 2–4 mm3 of a typical lunar rock sample–the average cathode accuracy is ∼1‰. Cathode reproducibility is typically ∼1‰ (2σ) for samples with at least 10 μg of Cl, increasing to ∼3–6‰ for aliquots with ∼1–2 μg Cl, similar to published SIMS results and sufficient to study astromaterials from the Moon, Mars, or 4 Vesta, which have tens of ‰ observed variations.

Tyler S. Anderson↗

Mass spectrometry and inhomogeneous ion optics

Work done in several areas to advance the state of the art of magnetic mass spectrometers is described. The calculations and data necessary for the design of inhomogeneous field mass spectrometers, and the calculation of ion trajectories through such fields are presented. The development and testing of solid state ion detection devices providing the capability of counting single ions is discussed. New techniques in the preparation and operation of thermal-ionization ion sources are described. Data obtained on the concentrations of copper in rainfall and uranium in air samples using the improved thermal ionization techniques are presented. The design of a closed system static mass spectrometer for isotopic analyses is discussed. A summary of instrumental aspects of a four-stage mass spectrometer comprising two electrostatic and two 90 deg. magnetic lenses with a 122-cm radius used to study the interaction of ions with solids is presented.

White, F. A.↗

A First Look at Carbon and Oxygen Stable Isotope Measurements of Martian Atmospheric C02 by the Phoenix Lander

Precise stable isotope measurements of the CO2 in the martian atmosphere have the potential to provide important constraints for our understanding of the history of volatiles, the carbon cycle, current atmospheric processes, and the degree of water/rock interaction on Mars. The isotopic composition of the martian atmosphere has been measured using a number of different methods (Table 1), however a precise value (<1%) has yet to be achieved. Given the elevated 13C values measured in carbonates in martian meteorites it has been supposed that the martian atmosphere was enriched in delta(sup 13)C. This was supported by measurements of trapped CO2 gas in EETA 79001[2] which showed elevated delta(sup 13)C values (Table 1). More recently, Earth-based spectroscopic measurements of the martian atmosphere have measured the martian CO2 to be depleted in delta(sup 13)C relative to CO2 in the terrestrial atmosphere. The spectroscopic measurements performed by Krasnopolsky et al. were reported with approx.2% uncertainties which are much smaller than the Viking measurements, but still remain very large in comparison to the magnitude of carbon and oxygen isotope fractionations under martian surface conditions. The Thermal Evolved Gas Analyzer (TEGA) instrument on the Mars Phoenix Lander included a magnetic sector mass spectrometer (EGA) which had the goal of measuring the isotopic composition of martian atmospheric CO2 to within 0.5%. The mass spectrometer is a miniature magnetic sector instrument intended to measure both the martian atmosphere as well as gases evolved from heating martian soils. Ions produced in the ion source are drawn out by a high voltage and focused by a magnetic field onto a set of collector slits. Four specific trajectories are selected to cover the mass ranges, 0.7 - 4, 7 - 35, 14 - 70, and 28 - 140 Da. Using four channels reduces the magnitude of the mass scan and provides simultaneous coverage of the mass ranges. Channel electron multiplier (CEM) detectors that operate in the pulse counting mode detect the ion beams.

Niles, P.B.↗

Development towards stable chlorine isotope measurements of astromaterials using the modified Middleton source of an accelerator mass spectrometer

The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35 Cl and 37 Cl. Chlorine isotope variations (reported as δ 37 Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) are documented to exceed 80‰ between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history. The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements. This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ 37 Cl measurements using the modified Middleton ion source of an existing accelerator mass spectrometer. For samples with as little as 1 μg Cl–the equivalent of 2–4 mm 3 of a typical lunar rock sample–the average cathode accuracy is ~1‰. Finally, cathode reproducibility is typically ~1‰ (2σ) for samples with at least 10 μg of Cl, increasing to ~3–6‰ for aliquots with ~1–2 μg Cl, similar to published SIMS results and sufficient to study astromaterials from the Moon, Mars, or 4 Vesta, which have tens of ‰ observed variations.

07 ISOTOPE AND RADIATION SOURCES↗

Installation and Characterization of Charged Particle Sources for Space Environmental Effects Testing

Charged particle sources are integral devices used by Marshall Space Flight Center s Environmental Effects Branch (EM50) in order to simulate space environments for accurate testing of materials and systems. By using these sources inside custom vacuum systems, materials can be tested to determine charging and discharging properties as well as resistance to sputter damage. This knowledge can enable scientists and engineers to choose proper materials that will not fail in harsh space environments. This paper combines the steps utilized to build a low energy electron gun (The "Skevington 3000") as well as the methods used to characterize the output of both the Skevington 3000 and a manufactured Xenon ion source. Such characterizations include beam flux, beam uniformity, and beam energy. Both sources were deemed suitable for simulating environments in future testing.

Skevington, Jennifer L.↗

Passivation of carbon steel through mercury implantation

An experiment, in which carbon steel samples were implanted with mercury ions from a broad beam ion source and their corrosion characteristics in air were evaluated, is described. Mercury doses of a few mA min/square cm at energies of a few hundred electron volts are shown to effect significant improvements in the corrosion resistance of the treated surfaces. In a warm moist environment the onset of rusting was extended from 15 min. for an untreated sample to approximately 30 hrs. for one implanted at a dose of 33 mA min/square cm with 1000 eV mercury ions.

Wilbur, P. J.↗