Search NASA⌕ Search

SEARCH · Search NASA

Results for “Jefferson Lab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

The Aerogel Cerenkov detector for the SHMS magnetic spectrometer in Hall C at Jefferson Lab

Hadronic reactions producing strange quarks such as exclusive or semi-inclusive kaon production, play an important role in studies of hadron structure and the dynamics that bind the most basic elements of nuclear physics. The small-angle capability of the new Super High Momentum Spectrometer (SHMS) in Hall C, coupled with its high momentum reach - up to the anticipated 11-GeV beam energy in Hall C - and coincidence capability with the well-understood High Momentum Spectrometer, will allow for probes of such hadron structure involving strangeness down to the smallest distance scales to date. To cleanly select the kaons, a threshold aerogel Cerenkov detector has been constructed for the SHMS. The detector consists of an aerogel tray followed by a diffusion box. Four trays for aerogel of nominal refractive indices of n =1.030, 1.020, 1.015 and 1.011 were constructed. The tray combination will allow for identification of kaons from 1 GeV/c up to 7.2 GeV/c, reaching 10 -2 proton and 10 -3 pion rejection, with kaon detection efficiency better than 95%. The diffusion box of the detector is equipped with 14 five-inch diameter photomultiplier tubes. Its interior walls are covered with Gore diffusive reflector, which is superior to the commonly used Millipore paper and improved the detector performance by 35%. The inner surface of the two aerogel trays with higher refractive index is covered with Millipore paper, however, those two trays with lower aerogel refractive index are again covered with Gore diffusive reflector for higher performance. The measured mean number of photoelectrons in saturation is ~12 for n =1.030, ~8 for n =1.020, ~10 for n =1.015, and ~5.5 for n =1.011. Here the design details, the results of component characterization, and initial performance tests and optimization of the detector are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test of the GEM Front Tracker for the SBS Spectrometer at Jefferson Lab

A new Large-Acceptance Forward Angle Spectrometer (Super BigBite) is under development at JLab/Hall A to optimally exploit the exciting opportunities o?ered by the 12 GeV upgrade of the electron beam. The tracker of this new apparatus is based on the Gas Electron Multiplier (GEM) technology, which has been chosen to optimize cost/performance, position resolution and to meet the high hit rate (>1 MHz/cm2). The first GEM detector modules, designed and built by the INFN Collaboration JLAB12, were tested at the DESY test beam facility in Hamburg, by using an electron beam with energy ranging from 2.0 to 6.0 GeV. In particular, two 40x50 cm2 and one 10x10 cm2 GEM chambers were equipped with a new implementation of the APV25 readout chip. Measurements were performed at di?erent impact points and angles between the electron beam and the plane of the GEM chambers, with one large chamber in a solenoid magnetic field up to 500 Gauss. In this report we present the technical characteristics of the detector and comment on the presently achieved performance.

Mammoliti, F.↗

The RICH detector for CLAS12 at Jefferson Lab

The CLAS12 spectrometer at JLab will offer unique possibilities to study the 3D nucleon structure in terms of TMDs and GPDs in the poorly explored valence region, and to perform high precision hadron spectroscopy. A large area ring-imaging Cherenkov detector has been designed to achieve the required hadron identification capability in the momentum range 3-8 GeV/c. The detector, based on a novel hybrid imaging design, foresees an aerogel radiator and an array of multi-anode photomultipliers. The detector concept and preliminary results of test-beams on a prototype are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryostat design and analysis of the superconducting magnets for Jefferson Lab's 11-GEV/C super high momentum spectrometer

This paper describes the mechanical design and analysis of the cryostats for the two cos(2theta) quadrupoles and the cos(theta) dipole. All the magnets are currently being bid for commercial fabrication. The results of finite element analysis for the magnet cryostat helium vessels and outer vacuum chambers which investigate the mechanical integrity under maximum allowable internal working pressure, maximum allowable external working pressure, and cryogenic temperature are discussed. The allowable stress criterion is determined based on the allowable stress philosophy of the ASME codes. The computed cryogenic heat load of the magnets is compared with the allowable cryogenic consumption budget. The presented cool-down time of the magnets was studied under the conditions of a limited supply rate and a controlled temperature differential of 50 K in the magnets.

43 PARTICLE ACCELERATORS↗

Design and analysis of the warm-to-cold suspension links for Jefferson Lab's 11-GEV/C super high momentum spectrometer

This paper describes design and analysis performed for the warm-to-cold suspension links of the warm iron yoke superconducting quadrupole magnets, and superconducting dipole magnet. The results of investigation of titanium Ti-6Al-4V and Nitronic 50 stainless steel for the suspension links to support the cold mass, preloads, forces due to cryogenic temperature, and imbalanced magnetic forces from misalignments are presented. Allowable stresses at normal-case scenarios and worst-case scenarios, space constraints, and heat leak considerations are discussed. Principles of the ASME Pressure Vessel Code were used to determine allowable stresses. Optimal angles of the suspension links were obtained by calculation and finite element methods. The stress levels of suspension links at multiple scenarios are presented, discussed, and compared with the allowable stresses.

36 MATERIALS SCIENCE↗

Final results of the GEp(III) experiment at Jefferson Lab

The set of proton elastic form factor ratio data was extended to Q{sup 2} = 8.5 GeV{sup 2} with a recent experiment at JLab, GEp(III); the nucleon form factor data base is discussed and several conclusions presented. These data are the result of measurements of the polarization of the recoil proton; they have been known to differ significantly from Rosenbluth separation of cross section data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nb 3 Sn multicell cavity coating system at Jefferson Lab

Superconducting radio frequency niobium cavities are the building blocks of modern accelerators for scientific applications. Lower surface resistance, higher fields, and high operating temperatures advance the reach of the future accelerators for scientific discovery as well as potentially enabling cost-effective industrial solutions. We describe the design and performance of an Nb 3 Sn coating system that converts the inner surface of niobium cavities to an Nb 3 Sn film. The niobium surface, heated by radiation from the niobium retort, is exposed to Sn and SnCl 2 vapor during the heat cycle, which results in about 2 μm Nb 3 Sn film on the niobium surface. Film composition and structure as well as radio frequency properties with 1-cell R&D cavities and 5-cell practical accelerator cavities are presented.

47 OTHER INSTRUMENTATION↗

The N* physics program at Jefferson Lab

Abstract Recent measurements of nucleon resonance transition form factors with CLAS at Je erson Lab are dis- cussed. The new data con rm the assertion of the symmetric constituent quark model of the Roper as the rst radial excitation of the nucleon. The data on high Q2 n{pi+} production better constrain the branching ratios {Beta}N_{pi} and {Beta} N_{eta}. For the first time, the longitudinal transition amplitude to the S11(1535) was extracted from the n{pi+} data. Also, new results on the transition amplitudes for the D13(1520) resonance are presented showing a rapid transition from helicity 3/2 dominance seen at the real photon point to helicty 1/2 dominance at higher Q2. I also discuss the status of the search for new excited nucleon states.

Burkert, Volker↗

Quasi elastic cross sections for the Bi-209(e, e-prime p) Pb-208 reaction: Jefferson Lab experiment E06007

Quasi elastic cross sections were measured for the first time for both negative and positive missing momenta for the {sup 209}Bi(e,e'p){sup 208}Pb reaction leading to the ground state and hole states of (208)Pb. Experimental cross sections obtained between -0.3 GeV/c to 0.3 GeV/c agree with theoretical calculations using RDWIA techniques both in shape and magnitude for the ground state. The data for the ground state production of {sup 208}Pb are consistent with a theoretical model assuming a single proton(1.06 +- 0.10) in the 1h9/2 orbit in {sup 209}Bi.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Studies of GPDs at Jefferson Lab: results and future experiments

Here, the Generalized Parton Distributions (GPDs) have emerged as a universal tool to describe hadrons in terms of their elementary constituents, the quarks and the gluons. Deeply Virtual Compton Scattering (DVCS) on a proton or neutron (N), eN → e'N'γ, is one of the simplest processes that can be described in terms of GPDs. The amplitudes of DVCS and Bethe-Heitler, process where a photon is emitted by the incident or scattered electron, can be accessed via cross section measurements or exploiting their interference which give rise to spin asymmetries. Spin asymmetries, cross sections and cross-section differences can be connected to different combinations of the four leading order GPDs (H, E, $\tilde{H} $, $\tilde{E} $) for the two quark flavors depending on the observable and the type of target.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Redesigning the Jefferson Lab Hall A beam line for high precision parity experiments

The Continuous Electron Beam Accelerator Facility (CEBAF) was built with a thermionic electron source and the three original experimental hall lines reflected this. A few years after beam delivery began a parity violation experiment was approved and two polarimeters were installed in the Hall A beam line. The beam raster system was placed after the new Compton polarimeter, before one accelerator quadrupole and four quadrupoles in the new Moller polarimeter. It was very difficult to meet experimental requirements on envelope functions and raster shape with this arrangement so a sixth quadrupole was installed downstream of the Moller polarimeter to provide an additional degree of freedome. All of the parity experiments in Hall A have been run with this still-unsatisfactory configuration. The MOLLER experiment is predicated on achieving a 2% error on a 32 ppb asymmetry. Beam line changes are required to meet the systematic error budget. This work documents the existing beam line, an interim change which can be accomplished during a annual maintenance down, and the final configuration for MOLLER and subsequent experiments.

47 OTHER INSTRUMENTATION↗

The Superconducting Horizontal Bend Magnet for the Jefferson Lab's 11 GeV/c Super High Momentum Spectrometer

A collaboration between NSCL and Jlab has developed the reference design and coil winding for Jlab's Super High Momentum Spectrometer (SHMS) horizontal bend magnet. A warm iron ??C?? type superferric dipole magnet will bend the 12 GeV/c particles horizontally by 3?? to allow the SHMS to reach angles as low as 5.5??. This requires an integral field strength of up to 2.1 T.m. The major challenges are the tight geometry, high and unbalanced forces and a required low fringe field in primary beam path. A coil design based on flattened SSC Rutherford cable that provides a large current margin and commercially available fiberglass prepreg epoxy tape has been developed. A complete test coil has been wound and will be cold tested. This paper present the modified magnet design includes coil forces, coil restraint system and fringe field. In addition, coil properties, quench calculations and the full mechanical details are also presented.

43 PARTICLE ACCELERATORS↗

Coupled Transient Finite Element Simulation of Quench in Jefferson Lab's 11 GeV Super High Momentum Spectrometer Superconducting Magnets

This paper presents coupled transient thermal and electromagnetic finite element analysis of quench in the Q2, Q3, and dipole superconducting magnets using Vector Fields Quench code. Detailed temperature distribution within coils and aluminum force collars were computed at each time step. Both normal (quench with dump resistor) and worst-case (quench without dump resistor) scenarios were simulated to investigate the maximum temperatures. Two simulation methods were utilized, and their algorithms, implementation, advantages, and disadvantages are discussed. The first method simulated the coil using nonlinear transient thermal analysis directly linked with the transient circuit analysis. It was faster because only the coil was meshed and no eddy current was modeled. The second method simulated the whole magnet including the coil, the force collar, and the iron yoke. It coupled thermal analysis with transient electromagnetic field analysis which modeled electromagnetic fields including eddy currents within the force collar. Since eddy currents and temperature in the force collars were calculated in various configurations, segmentation of the force collars was optimized under the condition of fast discharge.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Convergence Studies of Thermal and Electromagnetic Transient Quench Analysis of 11 GeV Super High Momentum Spectrometer Superconducting Magnets in Jefferson Lab

This paper presents results of convergence studies of transient thermal and electromagnetic quench analysis of five Super High Momentum Spectrometer (SHMS) superconducting magnets: HB, Q1, Q2, Q3, and Dipole, using Vector Fields Quench analysis codes. The convergence of the hot spot temperature and solution solve times were used to investigate the effects of element types, mesh densities, and tolerance criteria. The comparisons between tetrahedral elements and hexahedral elements was studied, and their advantages and disadvantages were discussed. Based on the results of convergence studies, a meshing guideline for coils is presented. The impact of iteration tolerance to the hot spot temperature was also explored, and it is found that tight tolerances result in extremely long solve times with only marginal improvements in the results.

43 PARTICLE ACCELERATORS↗