Search NASA⌕ Search

SEARCH · Search NASA

Results for “LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

An increased extraction energy booster complex for the Jefferson Lab electron ion collider

The proposed Jefferson Lab Electron Ion Collider (JLE-IC) envisions an ion complex composed of an ion linac, two booster synchrotrons and a collider ring. The evolv-ing design of the JLEIC booster required an increase in the extraction energy of the booster from 8 to 12.1 GeV kinetic energy, necessitating two machines instead of one. The decision was also made to switch to warm magnets, thus increasing the total radius of the 8 GeV booster. With the second booster being the same size as the collider rings. In this work we present the new designs for JLE-IC?s Low Energy Booster (LEB) and High Energy Boost-er (HEB).

Nissen, Edith↗

Final Booster Complex Design for the Jefferson Lab Electron Ion Collider*

In this work we show the final iteration of the design for the booster complex of the Jefferson Lab EIC, which would have brought the ions from an energy (proton) of 150 MeV up to 12.1 GeV. This complex would have consisted of two figure-8 rings. The Low Energy Booster (LEB) which would have accelerated its protons from 150 MeV to 8 GeV, and has had its lattice tweaked to increase the effectiveness of chromaticity cancellations. The High Energy Booster (HEB) would have brought the 8 GeV protons up to 12.1 GeV. The HEB would in the tunnel that was designed for the collider rings, sitting on top of them. It has had a bypass around the interaction region added, as well as a cooling solenoid installed.

Nissen, E. A.↗

Redesign of the Jefferson Lab -300 kV DC Photo-Gun for High Bunch Charge Operations

Production of high bunch charge beams for the Electron-Ion Collider (EIC) is a challenging task. High bunch charge (a few nC) electron beam studies at Jefferson Lab using an inverted insulator DC high voltage photo-gun showed evidence of space charge limitations starting at 0.3 nC, limiting the maximum delivered bunch charge to 0.7 nC for beam at -225 kV, 75 ps (FWHM) pulse width, and 1.64 mm (rms) laser spot size. The low extracted charge is due to the modest longitudinal electric field (Ez) at the photocathode leading to beam loss at the anode and downstream beam pipe. To reach the few nC high bunch charge goal, and to correct the beam deflection exerted by the non-symmetric nature of the inverted insulator photo-gun the existing photo-gun was modified. This contribution discusses the electrostatic design of the modified photo-gun obtained using CST Studio Suite’s electromagnetic field solver. Beam dynamics simulations performed using General Particle Tracer (GPT) with the resulting electrostatic field map obtained from the modified electrodes confirmed the validity of the new design.

Wijethunga, S.A.K.↗

RADIATION DOSE SIMULATIONS FOR JEFFERSON LAB’S PERMANENT MAGNET RESILIENCY LDRD STUDY

In late 2023, Thomas Jefferson National Accelerator Facil- ity (Jefferson Lab) funded a Laboratory Directed Research and Development (LDRD) grant dedicated to investigating the impact of radiation on permanent magnet materials. This research initiative is specifically geared towards assessing materials slated for use in the CEBAF energy upgrade. The experimental approach involves strategically placing perma- nent magnet samples throughout the accelerator, exposing them to varying radiation doses. The simulation code BD- SIM is used to first validate the data and then to simulate the effects on future higher energy passes to study the degra- dation effects on the permanent magnets. In this paper we present the progress of that work.

Deitrick, K.↗

Permanent Magnet Resiliency in Jefferson Lab’s Radiation Environment: LDRD Grant Status and Plans

As the FFA@CEBAF energy upgrade study progresses, it is important to investigate the impact of radiation exposure on the permanent magnet materials to be used in the upgraded fixed field alternating gradient (FFA) arcs. To address this, Jefferson Lab has awarded a Laboratory Directed Research and Development (LDRD) grant to study the resiliency of several permanent magnet materials placed in a radiation environment similar to that in which they are expected to operate. Samples of NeFeB and SmCo are to be placed alongside appropriate dosimetry in a variety of radiation environments in the beam enclosure and experimental halls at CEBAF. The magnet degradation will be measured, and extrapolated to the higher energies expected during operations after the energy upgrade. This document will describe the current status of the LDRD study, as well as describe the upcoming plans. It will also direct the readers to other proceedings which further detail the work thus far.

Bodenstein, R.↗

SRF CAVITY FAULT PREDICTION USING DEEP LEARNING AT JEFFERSON LAB

In this study, we present a deep learning-based pipeline for predicting superconducting radio-frequency (SRF) cavity faults in the Continuous Electron Beam Accelera-tor Facility (CEBAF) at Jefferson Lab. We leverage pre-fault RF signals from C100-type cavities and employ deep learning to predict faults in advance of their onset. We train a binary classifier model to distinguish between stable and impending fault signals. Test results show accuracies exceeding 99% for distinguishing between normal signals and pre-fault signals from a class of more slowly developing fault types, such as microphonics. We describe results from a proof-of-principle demonstration on a realistic, imbalanced data set and report performance metrics. Encouraging results suggest that future SRF systems could leverage this framework and implement measures to mitigate the onset in more slowly developing fault types.

Rahman, M.↗

Beam results for the new super-conducting booster at Jefferson Lab

The performance results of a new super-conducting booster for the CEBAF injector at Jefferson Lab, could be of interest for other similar electron injectors. A recent addition of this new booster has provided us the ability to achieve a more adiabatic acceleration and therefore an improvement to the beam dynamics and beam brightness. It has also simplified the design and operation of the section of the injector responsible for accelerating the electron beam from a few hundred keV to several MeV (typically 6.7 MeV). The addition of the new booster was part of an upgrade to the CEBAF injector to improve the beam quality for future physics experiments with high sensitivity to beam quality. The booster consists of two cavities: a 2-cell cavity followed by a 7-cell cavity. This combination allows for a wide range of input electron beam energies, from 130 keV to more than 300 keV. In fact, during the last year, the booster was successfully operated with 140,180, and 200 keV input beam energies as the electron gun was being upgraded. This paper describes the new booster, presents beam optics data results from different beam studies, commissioning, and the physics quality beam operation.

Accelerator Physics↗

Interaction Region Magnets for Future Electron-Ion Collider ¿at Jefferson Lab

The Jefferson Lab Electron Ion Collider (JLEIC) is a pro-posed new machine for nuclear physics research. It uses the existing CEBAF accelerator as a full energy injector to deliver 3 to 12 GeV electrons into a new electron collider ring. An all new ion accelerator and collider complex will deliver up to 200 GeV protons. The machine has luminosity goals of 1034 cm-2 sec-1. The whole detector region including forward detection covers about 80 meters of the JLEIC complex. The interaction region design has recently been optimized to accommodate 200 GeV proton energy using conventional NbTi superconducting magnet technology. This paper will describe the requirements and preliminary designs for both the ion and electron beam magnets in the most complex 34.5 m long interaction region (IR) around the interaction point (IP). The interaction region has over thirty-four superconducting magnets operating at 4.5K; these include dipoles, quadrupoles, skew quadrupoles, solenoids, horizontal and vertical correctors and higher order multipole magnets. The paper will also dis-cuss the electromagnetic interaction between these magnets.

Rajput-Ghoshal, Renuka↗

RECENT DEVELOPMENTS OF Nb3Sn AT JEFFERSON LAB FOR SRF ACCELERATOR APPLICATION

The desire to reduce the construction and operating costs of future SRF accelerators motivates the search for alternative, higher-performing materials. Nb3Sn (Tc ~ 18.3 K and Hsh ~ 425 mT) is the front runner. However, tests of early Nb3Sn-coated cavities encountered strong Q-slopes limiting the performance. Learnings from studies of coated materials related to cavity performance prompted significant changes to the coating process. It is now possible to routinely produce slope-free cavities having Q0 > 2×1010 at 4 K and > 4×1010 up to the accelerating gradient in excess of 15 MV/m at its best. Obtaining similar results in five-cell cavities is a current goal to test them under an accelerator environment. This contribution discusses recent developments at Jefferson Lab.

Pudasaini, Uttar↗

Improved Electrostatic Design of the Jefferson Lab 300 kV DC Photogun and the Minimization of Beam Deflection

An electron beam with high bunch charge and high repetition rate is required for electron cooling of the ion beam to achieve the high luminosity required for the proposed electron-ion colliders. An improved design of the 300 kV DC high voltage photogun at Jefferson Lab was incorporated toward overcoming the beam loss and space charge current limitation experienced in the original design. To reach the bunch charge goal of ~ few nC within 75 ps bunches, the existing DC high voltage photogun electrodes and anode-cathode gap were modified to increase the longitudinal electric field (Ez) at the photocathode. The anode-cathode gap was reduced to increase the Ez at the photocathode, and the anode aperture was spatially shifted with respect to the beamline longitudinal axis to minimize the beam deflection introduced by the geometric asymmetry of the inverted insulator photogun. The electrostatic design and beam dynamics simulations were performed to determine the required modification. Beam-based measurement from the modified gun confirmed the reduction of the beam deflection, which is presented in this contribution.

Mamun, M. A.↗

Plasma processing of SRF cavities at Jefferson Lab: Experiment results and simulation insight

Plasma processing of superconducting radio frequency (SRF) cavities has been an active research effort at Jefferson Lab (JLab) since 2019, aimed at enhancing cavity performance by removing hydrocarbon contaminants and reducing field emission. In this experiment, processing using argon-oxygen and helium-oxygen gas mixtures to find minimum ignition power at different cavity pressure was investigated. Ongoing simulations are contributing to a better understanding of the plasma surface interactions and the fundamental physics behind the process. These simulations, combined with experimental studies, guide the optimization of key parameters such as gas type, RF power, and pressure to ignite plasma using selected higher-order mode (HOM) frequencies. This paper presents experimental data from argon-oxygen and helium-oxygen gas mixture C75 and C100 cavity plasma ignition studies, as well as simulation results for the C100-type cavity based on the COMSOL model previously applied to the C75 cavity.

Accelerator Physics↗

A Cross-Lab Qualification of Modified 120°C Baked Cavities

Within a global effort to understand and standardize the nitrogen-infusion and the low T bake procedure, one large grain and two fine grain single-cell cavity were treated and tested at FNAL and then send to other labs including DESY and JLab for further studies.

43 PARTICLE ACCELERATORS↗

In Situ Plasma Processing of Superconducting Cavities at Jefferson Lab

Jef­fer­son Lab began a plasma pro­cess­ing pro­gram start­ing in the spring of 2019. Plasma pro­cess­ing is a com­mon tech­nique for re­mov­ing hy­dro­car­bons from sur­faces, which in­creases the work func­tion and re­duces the sec­ondary emis­sion co­ef­fi­cient. Un­like he­lium pro­cess­ing which re­lies on ion bom­bard­ment of the field emit­ters, plasma pro­cess­ing uses free oxy­gen pro­duced in the plasma to break down the hy­dro­car­bons on the sur­face of the cav­ity. The resid­u­als of the hy­dro­car­bons in the form of water, car­bon monox­ide and car­bon diox­ide are re­moved from the cry­omod­ule as part of the process gas flow. The ini­tial focus of the ef­fort is pro­cess­ing C100 cav­i­ties by in­ject­ing RF power into the HOM cou­pler ports. We will then start in­ves­ti­gat­ing pro­cess­ing of C50 cav­i­ties by in­tro­duc­ing RF into the fun­da­men­tal power cou­pler. The plan is to start pro­cess­ing cry­omod­ules in the CEBAF tun­nel in the mid-term fu­ture, with a goal of im­prov­ing the op­er­a­tional gra­di­ents and the en­ergy mar­gin of the linacs. This work will de­scribe the sys­tems and meth­ods used at JLAB for pro­cess­ing cav­i­ties using an argon oxy­gen gas mix­ture. Be­fore and after plasma pro­cess­ing re­sults will also be pre­sented.

Powers, T.↗

Lab-Based Measurement of Remediation Techniques for Radiation Portal Monitors (Initial Report)

Radiation Portal Monitors (RPM) deployed by the Second Line of Defense (SLD) are known to be sensitive to the natural environmental radioactive background. There are several techniques used to mitigate the effects of background on the monitors, but since the installation environments can vary significantly from one another the need for a standardized, systematic, study of remediation techniques was proposed and carried out. This study is not meant to serve as the absolute last word on the subject. The data collected are, however, intelligible and useful. Some compromises were made, each of which will be described in detail. The hope of this initial report is to familiarize the SLD science teams with ORNL's effort to model the effect of various remediation techniques on simple, static backgrounds. This study provides a good start toward benchmarking the model, and each additional increment of data will serve to make the model more robust. The scope of this initial study is limited to a few basic cases. Its purpose is to prove the utility of lab-based study of remediation techniques and serve as a standard data set for future use. This importance of this first step of standardization will become obvious when science teams are working in parallel on issues of remediation; having a common starting point will do away with one category of difference, thereby making easier the task of determining the sources of disagreement. Further measurements will augment this data set, allowing for further constraint of the universe of possible situations. As will be discussed in the 'Going Forward' section, more data will be included in the final report of this work. Of particular interest will be the data taken with the official TSA lead collimators, which will provide more direct results for comparison with installation data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of Waste Treatment Plant Lab C3V (LB-S1) Stack Sampling Probe Location for Compliance with ANSI/HPS N13.1-1999

This report documents a series of tests used to assess the proposed air sampling location in the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Lab C3V (LB-S1) exhaust stack with respect to the applicable criteria regarding the placement of an air sampling probe. Federal regulations require that an air sampling probe be located in the exhaust stack in accordance with the criteria of American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream.

Air Sampling Probe↗

Semi-automated lab-on-a-chip for dispensing GA-68 radiotracers

We solved a technical problem that is hindering American progress in molecular medicine, and restricting US citizens from receiving optimal diagnostic care. Specifically, the project deals with a mother/daughter generator of positron-emitting radiotracers (Ge-68/Ga-68). These generator systems are approved in Europe but cannot be used in the USA, because of safety issues related to possible breakthrough of long-lived Ge-68 (mother) atoms. Europeans have demonstrated abilities of Ga-68-labeled radiotracers to image cancer foci with high sensitivity and specificity, and to use such methods to effectively plan therapy.The USA Food and Drug Administration (FDA) and Nuclear Regulatory Commission (NRC) have taken the position that every patient administration of Ga-68 should be preceded by an assay demonstrated that Ge-68 breakthrough is within acceptable limits. Breakthrough of parent elements is a sensitive subject at the FDA, as evidenced by the recent recall of Rb-82 generators due to inadvertent administrations of Sr-82. Commercially, there is no acceptable rapid method for assaying breakthrough of Ge-68 prior to each human administration. The gamma emissions of daughter Ga-68 have higher energies than the parent Ge-68, so that the shielding assays typically employed for Mo-99/Tc-99m generators cannot be applied to Ga-68 generators. The half-life of Ga-68 is 68 minutes, so that the standard 10-half-life delay (used to assess breakthrough in Sr-82/Rb-82 generators) cannot be applied to Ga-68 generators. As a result of the aforementioned regulatory requirements, Ga-68 generators are sold in the USA for animal use only.The American clinical community’s inability to utilize Ga-68 generators impairs abilities to treat patients domestically, and puts the USA at a disadvantage in developing exportable products. The proposed DOE project aimed to take advantage of recent technological advances developed for lab-on-a-chip (LOC) applications. Based on our experiences constructing such devices, the proposed microfluidics-based approach could provide cost-effective validation of breakthrough compliance in minutes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of Low-E Storm Windows in the PNNL Lab Homes

This study examines the performance of exterior and interior low-e storm panels with a controlled whole home experimental design using PNNL's Lab Homes. Summing the estimated annual average heating and cooling savings, the installation of low-e storm panels resulted in approximately 10% annual energy savings. The results of the experiment will be used to determine and validate performance of low-e storm windows over double pane clear glass windows in a whole home setting.

energy savings↗

Final report for Texas A&M University Group Contribution to DE-FG02-09ER25949/DE-SC0002505: Topology for Statistical Modeling of Petascale Data (and ASCR-funded collaboration between Sandia National Labs, Texas A&M University and University of Utah)

We summarize the contributions of the Texas A\&M University Group to the project (DE-FG02-09ER25949/DE-SC0002505: Topology for Statistical Modeling of Petascale Data - an ASCR-funded collaboration between Sandia National Labs, Texas A\&M U, and U Utah) during 6/9/2011 -- 2/27/2013.

97 MATHEMATICS AND COMPUTING↗