Search NASA⌕ Search

SEARCH · Search NASA

Results for “LASER SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Cryogenic Laser Calorimetry for Impurity Analysis

The results of a one-year effort to determine the applicability of laser-calorimetric spectroscopy to the study of deep-level impurities in silicon are presented. Critical considerations for impurity analysis by laser-calorimetric spectroscopy are discussed, the design and performance of a cryogenic laser calorimeter is described, and measurements of background absorption in high-purity silicon are presented.

Swimm, R. T.↗

Hypervelocity impact survivability experiments for carbonaceous impactors

We performed a series of hypervelocity impact experiments using carbon-bearing impactors (diamond, graphite, fullerenes, phthalic acid crystals, and Murchison meteorite) into Al plate at velocities between 4.2 and 6.1 km/s. These tests were made to do the following: (1) determine the survivability of carbon forms and organize molecules in low hypervelocity impact; (2) characterize carbonaceous impactor residues; and (3) determine whether or not fullerenes could form from carbonaceous impactors, under our experimental conditions, or survive as impactors. An analytical protocol of field emission SEM imagery, SEM-EDX, laser Raman spectroscopy, single and 2-stage laser mass spectrometry, and laser induced fluorescence (LIF) found the following: (1) diamonds did not survive impact at 4.8 km/s, but were transformed into various forms of disordered graphite; (2) intact, well-ordered graphite impactors did survive impact at 5.9 km/sec, but were only found in the crater bottom centers; the degree of impact-induced disorder in the graphite increases outward (walls, rims, ejecta); (3) phthalic acid crystals were destroyed on impact (at 4.2 km/s, although a large proportion of phthalic acid molecules did survive impact); (4) fullerenes did not form as products of carbonaceous impactors (5.9 - 6.1 km/s, fullerene impactor molecules mostly survived impact at 5.9 km/s; and (5) two Murchison meteorite samples (launched at 4.8 and 5.9 km/s) show preservation of some higher mass polycyclic aromatic hydrocarbons (PAHs) compared with the non-impacted sample. Each impactor type shows unique impactor residue morphologies produced at a given impact velocity. An expanded methodology is presented to announce relatively new analytical techniques together with innovative modifications to other methods that can be used to characterize small impact residues in LDEF craters, in addition to other acquired extraterrestrial samples.

Bunch, T. E.↗

Synthesis and Characterization of Fe(III)-Fe(II)- Mg- Al Smectite Solid Solutions and Implications for Planetary Science

This study demonstrates the synergies and limits of multiple measurement types for the detection of smectite chemistry and oxidation state on planetary surfaces to infer past geochemical conditions. Smectite clay minerals are common products of water-rock interactions throughout the solar system, and their detection and characterization provides important clues about geochemical conditions and past environments if sufficient information about their composition can be discerned. Here, we synthesize and report on the spectroscopic properties of a suite of smectite samples that span the intermediate compositional range between Fe(II), Fe(III), Mg, and Al end-member species using bulk chemical analyses, X-ray diffraction, Vis/IR reflectance spectroscopy, UV and green-laser Raman spectroscopy, and Mössbauer spectroscopy. Our data show that smectite composition and the oxidation state of octahedral Fe can be reliably identified in the near infrared on the basis of combination and fundamental metal-OH stretching modes between 2.1–2.9 μm, which vary systematically with chemistry. Smectites dominated by Mg or Fe(III) have spectrally distinct fundamental and combination stretches, whereas Al-rich and Fe(II)-rich smectites have similar fundamental minima near 2.76 μm, but have distinct combination M-OH features between 2.24 and 2.36 μm. We show that with expanded spectral libraries that include intermediate composition smectites and both Fe(III) and Fe(II) oxidation states, more refined characterization of smectites from MIR data is now possible, as the position of the 450 cm–1 absorption shifts systematically with octahedral Fe content, although detailed analysis is best accomplished in concert with other characterization methods. Our data also provide the first Raman spectral libraries of smectite clays as a function of chemistry, and we demonstrate that Raman spectroscopy at multiple excitation wavelengths can qualitatively distinguish smectite clays of different structures and can enhance interpretation by other types of analyses. Our sample set demonstrates how X-ray diffraction can distinguish between dioctahedral and trioctahedral smectites using either the (02,11) or (06,33) peaks, but auxiliary information about chemistry and oxidation state aids in specific identifications. Finally, the temperature-dependent isomer shift and quadrupole splitting in Mössbauer data are insensitive to changes in Fe content but reliability differentiates Fe within the smectite mineral structure.

Valerie K Fox↗

Quantum beats in two-color photoionization to the spin-orbit split continuum of Ar

We report a study of the quantum beats in two-color photoionization of argon. An attosecond extreme ultraviolet pulse train prepares an electronic wave packet of definite odd parity, with total angular momentum J = 1, targeting the states between 14.0 and 14.5 eV from the ground state. Two-photon ionization of this wave packet with a tunable infrared probe pulse makes the constituent states interfere in both continuum channels, corresponding to the core angular momenta j c = 1/2 and 3/2, respectively. We analyze photoelectron spectrograms as a function of the time delay of the probe pulse and identify oscillations due to several pairs of states through Fourier decomposition. We observe phase differences between the corresponding beat signals in the two spin-orbit split continua. Comparison of theoretical simulations with the experimental measurements allows us to interpret the amplitudes and phases of ionization signals. Furthermore, we express the observed phase differences in terms of the off-diagonal elements of the short-range scattering matrix and the dipole matrix elements to the continuum eigenchannels.

74 ATOMIC AND MOLECULAR PHYSICS↗

Element-specific investigations of ultrafast dynamics in photoexcited Cu2ZnSnS4 nanoparticles in solution

Ultrafast, light-induced dynamics in copper–zinc–tin–sulfide (CZTS) photovoltaic nanoparticles are investigated through a combination of optical and x-ray transient absorption spectroscopy. Laser-pump, x-ray-probe spectroscopy on a colloidal CZTS nanoparticle ink yields element-specificity, which reveals a rapid photo-induced shift of electron density away from Cu-sites, affecting the molecular orbital occupation and structure of CZTS. We observe the formation of a stable charge-separated and thermally excited structure, which persists for nanoseconds and involves an increased charge density at the Zn sites. Combined with density functional theory calculations, the results provide new insight into the structural and electronic dynamics of CZTS absorbers for solar cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pressure-Induced Dimerization of C 60 at Room Temperature as Revealed by an In Situ Spectroscopy Study Using an Infrared Laser

Using in situ high-pressure Raman spectroscopy and X-ray diffraction, the polymerization and structure evaluation of C 60 were studied up to 16 GPa at room temperature. The use of an 830 nm laser successfully eliminated the photo-polymerization of C 60 , which has interfered with the pressure effect in previous studies when a laser with a shorter wavelength was used as excitation. It was found that face-centered cubic (fcc) structured C 60 transformed into simple cubic (sc) C 60 due to the hint of free rotation for the C 60 at 0.3 GPa. The pressure-induced dimerization of C 60 was found to occur at about 3.2 GPa at room temperature. Our results suggest the benefit and importance of the choice of the infrared laser as the excitation laser.

36 MATERIALS SCIENCE↗

Double-walled containment cell

Double-walled containment cells are described as may be used for storage, transport, and examination of a sample held within the cell by use of optical analysis techniques. A double-walled containment cell can include multiple types of windows that can be located as desired on the containment cells and thereby provide for optical access to a sample for multiple optical analysis techniques. Disclosed containment cells can be sized and designed for use with existing optical analysis systems, e.g., laser ablation, X-ray diffraction, spectral analysis (e.g., Raman spectroscopy, infrared spectroscopy, laser-induced breakdown spectroscopy, etc.), imaging analysis, etc.

Villa-Aleman, Eliel↗

Application of emerging monitoring techniques at the Illinois Basin – Decatur Project

The Illinois Basin – Decatur Project is a large-scale carbon capture and storage demonstration project located in Decatur, Illinois, USA. In this project, one million metric tons of carbon dioxide (CO 2 ) was captured from an ethanol production facility and successfully injected into a deep saline reservoir over a period of three years. The scale of this project presented an opportunity to explore emerging technologies for effective long-term monitoring of the carbon capture and storage site. This research documents the application of three emerging monitoring techniques: (1) a prototype “open-path” sensor, a method of continuously monitoring atmospheric CO 2 by applying tunable diode laser absorption spectroscopy to provide a warning system for personnel safety along pipelines and at wellheads; (2) the Greenhouse Gas Laser Imaging Tomography Experiment (GreenLITE), an automated system for measuring two-dimensional spatial distribution of atmospheric CO 2 concentrations; and (3) periodic aerial imagery, a method of documenting surface-vegetation dynamics to detect vegetative responses to CO 2 leaks. The objective of this work was to assess the advantages and limitations of these monitoring techniques and quantify their reliability over an extended deployment at an active industrial site. These results will aid in determining viability of long-term monitoring on a commercial scale.

42 ENGINEERING↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Mineralogy and Astrobiology Detection Using Laser Remote Sensing Instrument

A multispectral instrument based on Raman, laser-induced fluorescence (LIF), laser-induced breakdown spectroscopy (LIBS), and a lidar system provides high-fidelity scientific investigations, scientific input, and science operation constraints in the context of planetary field campaigns with the Jupiter Europa Robotic Lander and Mars Sample Return mission opportunities. This instrument conducts scientific investigations analogous to investigations anticipated for missions to Mars and Jupiter's icy moons. This combined multispectral instrument is capable of performing Raman and fluorescence spectroscopy out to a >100 m target distance from the rover system and provides single-wavelength atmospheric profiling over long ranges (>20 km). In this article, we will reveal integrated remote Raman, LIF, and lidar technologies for use in robotic and lander-based planetary remote sensing applications. Discussions are focused on recently developed Raman, LIF, and lidar systems in addition to emphasizing surface water ice, surface and subsurface minerals, organics, biogenic, biomarker identification, atmospheric aerosols and clouds distributions, i.e., near-field atmospheric thin layers detection for next robotic-lander based instruments to measure all the above-mentioned parameters. OCIS codes: (120.0280) Remote sensing and sensors; (130.0250) Optoelectronics; (280.3640) Lidar; (300.2530) Fluorescence, laser-induced; (300.6450) Spectroscopy, Raman; (300.6365) Spectroscopy, laser induced breakdown

Abedin, M. Nurul↗

High-resolution atmospheric spectroscopy using a diode laser heterodyne spectrometer

A tunable-diode-laser radiometer with a spectral resolution of 0.007/cm was used to obtain IR solar absorption spectra in the 9.1-11.1 micron region. Spectra exhibiting absorption by HNO3, CO2, O3, and H2O were obtained in a piecewise manner using emission modes from a single Pb-salt laser local oscillator. The measured spectra were compared to synthetic atmospheric spectra calculated using a line-by-line model. The results demonstrate that high-resolution IR solar absorption spectroscopy and atmospheric extinction measurements can be routinely performed over wide spectral regions using semiconductor lasers.

Hoell, J. M., Jr.↗

Absorption spectroscopy with quantum cascade lasers

Novel pulsed and cw quantum cascade distributed feedback (QC-DFB) lasers operating near lambda=8 micrometers were used for detection and quantification of trace gases in ambient air by means of sensitive absorption spectroscopy. N2O, 12CH4, 13CH4, and different isotopic species of H2O were detected. Also, a highly selective detection of ethanol vapor in air with a sensitivity of 125 parts per billion by volume (ppb) was demonstrated.

NASA Discipline Life Sciences Technologies↗

Elemental analysis of air-sensitive frozen molten salt samples using an inert transfer chamber for LIBS/LA-ICP-TOF-MS analysis

A novel inert sample transfer system was developed and employed to enable, for the first time, the analysis of air-sensitive salt samples in a two-volume ablation cell using simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA)-inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) analysis. Molten salts are of growing interest as a medium for advanced nuclear reactors and nuclear fuel reprocessing technologies continue to be developed around their use. However, compositional analysis of molten salt samples can be challenging because of their air-sensitive nature and varying solubilities leading to inaccurate measurements when digested. LA-based analysis provides an alternate method to digestion and can provide rapid elemental information with little sample preparation. In this study, LIBS and LA-ICP-TOF-MS were used to analyze the Ce content in frozen salt samples taken from a series of electrochemical experiments. Calibrations were built for each technique, and the resulting limits of detection for Ce were estimated to be 107 and 58 µg g −1 for LIBS and LA-ICP-TOF-MS, respectively. Test samples from the electrochemical experiments were analyzed using these calibrations. The results matched bulk digestion-based ICP-optical emission spectroscopy values, and daily trends in Ce concentration changes were identified. Additionally, the LIBS and LA-ICP-TOF-MS analysis was demonstrated for identifying microgram per gram levels of components and detecting trace contaminants. The impurities detected by LIBS included Al, Mg, Ca, and Na. The impurities detected by LA-ICP-TOF-MS included W, Ag, Al, Fe, Ni, Mo, Nd, Sm, Th, and U.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Distinguishing the XUV-induced Coulomb explosion dynamics of iodobenzene using covariance analysis

The primary and secondary fragmentation dynamics of iodobenzene following its ionization at 120 eV were determined using three-dimensional velocity map imaging and covariance analysis. Site-selective iodine 4d ionization was used to populate a range of excited polycationic parent states, which primarily broke apart at the carbon-iodine bond to produce I+ with phenyl or phenyl-like cations (C n H x + or C n H, with n = 1 – 6 and x = 1 – 5). The molecular products were produced with varying degrees of internal excitation and dehydrogenation, leading to stable and unstable outcomes. This further allowed the secondary dynamics of C 6 H x 2+ intermediates to be distinguished using native-frame covariance analysis, which isolated these processes in their own centre-of-mass reference frames. Furthermore, the mass resolution of the imaging mass spectrometer used for these measurements enabled the primary and secondary reaction channels to be specified at the level of individual hydrogen atoms, demonstrating the ability of covariance analysis to comprehensively measure the competing fragmentation channels of aryl cations, including those involving intermediate steps.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurement of atomic oxygen densities using TALIF on a dielectric barrier discharge: insights into the volume above a micro cavity plasma array

Dielectric barrier discharges, particularly micro cavity plasma arrays, offer significant potential for plasma-catalytic research due to their ability to ignite plasma in direct contact with a catalytic surface, enabling the observation of plasma-surface interactions. A key factor in their application is the generation of reactive species, such as atomic oxygen, within the cavities. These species can interact with both the surface (e.g. for activation or cleaning) and the gas being treated (e.g. for oxidation). Given the central role of oxygen atoms in plasma catalysis and their use as a model for more complex species, this work investigates the transport of these atoms out of the cavities. Two-photon absorption laser-induced fluorescence spectroscopy with picosecond laser excitation is performed in the volume above the cavities. The results are compared with a basic diffusion model. The reactor operates with a He/O 2 mixture at a flow rate of 1 slm and atmospheric pressure. Densities of up to 10 16 cm -3 are measured near the surface. Time-dependent measurements show that, at a distance of 350 µm from the surface, a density equilibrium is reached within less than 3 ms of reactor operation. Decay times due to ozone formation after the reactor is turned off are on a similar scale. Spatially resolved measurements show that the oxygen density decreases exponentially from the surface but remains detectable up to approximately 1 mm above the surface, indicating significant application potential. Variations in the O 2 admixture show a density maximum at 0.4%, confirming previous helium state enhanced actinometry measurements within the cavities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Field Vector Measurements Using Doppler-Free Saturation Spectroscopy

Experimentally measuring the magnetic-field vector topology in low-cost fusion-concept devices will provide critical information required to optimize and accelerate the development of those concepts for economical fusion energy. The magnetic-field measurement techniques most commonly used in modern tokamaks, i.e., beam-emission spectroscopy and optical emission spectroscopy, are not suitable below 5000 Gauss due to a lack of sensitivity. To diagnose magnetic field relevant to some of the ARPA-E-supported fusion concepts (50 to 1000 Gauss), a novel approach is required. Doppler-free saturation spectroscopy (DFSS) is a pump/probe laser-based technique and has been successfully demonstrated in the laboratory to provide a magnetic-field measurement accuracy of <10 Gauss. DFSS is implemented to obtain ultra-high-resolution spectra at a localized point in space. The spectral data is then fit to the Schrödinger equation for determination of the magnetic-field vector. To obtain the magnetic-field topology, the measurement spatial location is scanned over the desired region of space by steering the DFSS pump laser beam. The goal of this project is to assemble and commission a portable DFSS diagnostic capable of 2-D magnetic-field vector measurements utilizing the Hα spectral line profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

UV laser long-path absorption spectroscopy

Long path Differential Optical Absorption Spectroscopy (DOAS) using a picosecond UV laser as a light source was developed in our institute. Tropospheric OH radicals are measured by their rotational absorption lines around 308 nm. The spectra are obtained using a high resolution spectrograph. The detection system has been improved over the formerly used optomechanical scanning device by application of a photodiode array which increased the observed spectral range by a factor of 6 and which utilizes the light much more effectively leading to a considerable reduction of the measurement time. This technique provides direct measurements of OH because the signal is given by the product of the absorption coefficient and the OH concentration along the light path according to Lambert-Beers law. No calibration is needed. Since the integrated absorption coefficient is well known the accuracy of the measurement essentially depends on the extent to which the OH absorption pattern can be detected in the spectra. No interference by self generated OH radicals in the detection lightpath has been observed. The large bandwidth (greater than 0.15 nm) and the high spectral resolution (1.5 pm) allows absolute determination of interferences by other trace gas absorptions. The measurement error is directly accessible from the absorption-signal to baseline-noise ratio in the spectra. The applicability of the method strongly depends on visibility. Elevated concentrations of aerosols lead to considerable attenuation of the laser light which reduces the S/N-ratio. In the moderately polluted air of Julich, where we performed a number of OH measurement spectra. In addition absorption features of unidentified species were frequently detected. A quantitative deconvolution even of the known species is not easy to achieve and can leave residual structures in the spectra. Thus interferences usually increase the noise and deteriorate the OH detection sensitivity. Using diode arrays for sensitive absorption measurements some specific problems of those detectors have to be solved experimentally (i.e. fixed pattern noise, dark signal noise, nonuniform efficiency of individual elements, spatial sensitivity variations). In order to improve the low spatial resolution we performed laboratory studies using a multiple reflection cell to convert the long path technique to a real in situ point measurement. Under the conditions of field experiments in Julich residual absorbance signals at present are about 1.5x10(exp -4) corresponding to an OH detection sensitivity of 2x10(exp 6) OH/cm(exp 3) using a light path of 5.8 km. Total integration times for one measurement point vary between a few minutes and an hour.

Dorn, Hans-Peter↗