Search NASA⌕ Search

SEARCH · Search NASA

Results for “Leak Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Piping Connector

A complex of high pressure piping at Stennis Space Center carries rocket propellants and other fluids/gases through the Center's Component Test Facility. Conventional clamped connectors tend to leak when propellant lines are chilled to extremely low temperatures. Reflange, Inc. customized an existing piping connector to include a secondary seal more tolerant of severe thermal gradients for Stennis. The T-Con connector solved the problem, and the company is now marketing a commercial version that permits testing, monitoring or collecting any emissions that may escape the primary seal during severe thermal transition.

Source record↗

Evaluation of NETL’s Self-Healing Metallic Coating for Internal Corrosion Protection of Natural Gas Pipelines: Field Test

Steel pipelines are a safe, reliable, and affordable way to transport natural gas. However, the presence of impurities (e.g., water, carbon dioxide, and hydrogen sulfide) in the natural gas can cause internal corrosion, which can lead to pipeline leaks and failure. This paper reports on field tests of an innovative self-healing, corrosion-resistant, metallic coating developed at the National Energy Technology Laboratory (NETL) for protecting the interior surfaces of pipelines.

carbon dioxide (CO2)↗

Advancing Building Air Leakage Measurement and Modeling: Measurement of Interior Air Leaks, Experimental Comparison to Conventional Methods, and Building Modeling Characteristics

This report, Advancing Building Air Leakage Measurement and Modeling: Measurement of Interior Air Leaks, Experimental Comparison to Conventional Methods, and Building Modeling Characteristics, developed two new building air leakage measurement methods, experimentally evaluated the performance in comparison to conventional methods, experimentally evaluated the behavior of leaks for specific crack structures, and identified testing constraints and model implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Airborne Measurements of Nitric Oxide, Nitrogen Dioxide, Ozone, and Total Reactive Nitrogen During the NASA Global Tropospheric Experiment

Fabrication of the University of Michigan Multichannel Chemiluminescence Instrument (UMMCI) was completed in early 1996 and the instrument participated in test flights on the NASA P3B at Wallops Island prior to integration and deployment for the PEM- Tropics A Mission. The UMMCI consists of 4 channels for simultaneous measurements of ozone and NO with the option for measurements of NO2 and NOy (total reactive nitrogen) when converters are placed upstream of the NO channels. Each NO channel consists of a zeroing volume and reaction vessel, while the ozone channel consists of an ozone catalyst (or scrubber) trap that is not in line with the reaction vessel. The detectors in all for channels are Hamamatsu photomultiplier tubes, which are followed by pulse amplifier discriminators on the NO channels and an electrometer on the ozone channel. Schematics of the Detector Module and NOx/03 Probe Insert and Diagrams of the Control and Data System, the Power and Ground System, the Gas Flow System, and the Calibration System Flow are attached. Intercomparisons were conducted with G. Gregory, NASA/Langley, during the test flights (following prior calibration of the ozone generator/calibrators at the Wallops Long-Path Absorption facility). Initial test results appeared to be reasonable, and instrument characterization studies proceeded for the ozone channel and the 3 NO channels until deployment for integration for the PEM-Tropics Mission. Ozone data was obtained for Flights #4, and 6-2 1, and finalized data was submitted to the PEM-Tropics Data Archive and to the Science Team during the April 1997 Data Workshop. Although it initially appeared that the instrument sensitivity varied, subsequent tests showed that this was the fault of a leak in the ozone calibrator. In fact; the instrument sensitivity has not been observed to vary in a large number of tests over the years since the PEM-Tropics mission. We have, therefore, a very high degree of confidence in the O3 data that we submitted. NO data was obtained for all flights except the mission out of Christmas Island and the subsequent return to Hawaii, during which time the NO channels were contaminated with back-flushing pure NO from the O3 channel. The NO channels were found to suffer from a varying artifact (7 - 22 pptv) which made the instrument's results unreliable for the marine boundary layer portions of the missions (where conditions were extremely clean with NO typically < 2 pptv and O3 only 8 ppbv). Nonetheless, the NO values were an upper limit and were quite useful in identifying pollution layers and outflow from the Latin American Continent. NO data was submitted to the archive for all flights during which data was obtained. Ozone data from the P3B was among the results presented in several peer-reviewed publications. Notably, the ozone data supported the first published finding of evidence for the occurrence of aerosol nucleation in the marine boundary layer. As well, the ozone data was utilized in a treatment of the wavenumber spectra of winds, temperature and trace gases and to demonstrate the occurrence of layering as observed by the P3B during PEM-Tropics A . O3 and NO data were used in an assessment of the impact of southern hemispheric biomass burning, and in the role of NOx and O3 in HOx photochemistry during the PEM Tropics A mission. These data, along with other species measured during PEM-Tropics A, have also been employed in the generation of climatologies for tropospheric ozone and its precursors by the PI's research group.

Carroll, Mary Anne↗

Leak-tight crack repair for 304L stainless steel using friction surfacing

Here, friction surfacing (FS) was investigated as a method for sealing 50 μm wide thru-cracks in 3-mm-thick 304L stainless steel (304L) plate. Friction surfacing was performed using two sizes of 304L consumable rod, with diameters of 9.52 mm and 12.7 mm, on two substrate conditions (clean and oxidized). Friction surfacing was able to deposit a 600 μm thick coating and repair cracks to a depth of 100 μm - 200 μm below the original surface, when using the 12.7-mm-diameter consumable rod for both substrate conditions. Helium leak rates of 10 -10 atm-cc/s were achieved on crack repairs, designating them as leak-tight by the ANSI N14.5 standard. Optical and scanning electron microscopy were used to investigate the coating microstructure and bond interfaces. In this study, the 12.7-mm-diameter rod performed better with disruption of the oxide layer on the oxidized substrate and providing a more homogenous coating. Mechanical properties of the coated samples were evaluated by performing micro-indentation, tensile, bending, and adhesion testing. Higher hardness in the coatings was observed due to the fine equiaxed grains resulting from dynamic recrystallization. Complete consolidation of plastically deformed material on the substrate and a strong diffusion bond across the interface was observed. This was reflected in tensile and bending properties of the FS coatings being comparable to those of uncoated specimen. No delamination of the FS coating was observed during adhesion testing. The results demonstrate that friction surfacing is a viable option to seal cracks in stainless steels.

36 MATERIALS SCIENCE↗

Study to develop improved methods to detect leakage in fluid systems, phase 2

An ultrasonic contact sensor engineering prototype leak detection system was developed and its capabilities under cryogenic operations demonstrated. The results from tests indicate that the transducer performed well on liquid hydrogen plumbing, that flow and valve actuation could be monitored, and that the phase change from gaseous to liquid hydrogen could be detected by the externally mounted transducers. Tests also demonstrate the ability of the system to detect internal leaks past valve seats and to function as a flow meter. Such a system demonstrates that it is not necessary to break into welded systems to locate internal leaks.

Janus, J. C.↗

Performance of Subscale Docking Seals Under Simulated Temperature Conditions

A universal docking system is being developed by the National Aeronautics and Space Administration (NASA) to support future space exploration missions to low Earth orbit (LEO), to the moon, and to Mars. The candidate docking seals for the system are a composite design consisting of elastomer seal bulbs molded into the front and rear sides of a metal ring. The test specimens were subscale seals with two different elastomer cross-sections and a 12-in. outside diameter. The seal assemblies were mated in elastomer seal-on-metal plate and elastomer seal-on-elastomer seal configurations. The seals were manufactured from S0383-70 silicone elastomer compound. Nominal and off-nominal joint configurations were examined. Both the compression load required to mate the seals and the leak rate observed were recorded while the assemblies were subjected to representative docking system operating temperatures of -58, 73, and 122 F (-50, 23, and 50 C). Both the loads required to fully compress the seals and their leak rates were directly proportional to the test temperature.

Smith, Ian M.↗

Apparatus for Testing Flat Specimens of Thermal Insulation

An apparatus has been developed to implement an improved method of testing flat-plate specimens of thermal-insulation materials for cryogenic application. The method includes testing under realistic use conditions that could include vacuum and mechanical loading at a pressure up to 70 psi (=0.48 MPa). The apparatus can accommodate a rigid or flexible specimen having thickness up to 1.25 in. (=3.2 cm) and diameters between 6 and 10 in. (about 15.2 and 25.4 cm, respectively). Typical test conditions include boundary temperatures between 77 K and 373 K and vacuum/interstitial gas filling at a pressure between 10(exp -6) torr (=1.3 x 10(exp -4) Pa) and 760 torr (atmospheric pressure =0.1 MPa). The interstitial gas could be N2, He, CO2, or any other suitable gas to which the insulation is expected to be exposed in use. Relative to prior apparatuses and testing methods, this apparatus and the testing method that it implements offer advantages of relative simplicity and ease of use. The basic principle of operation of the apparatus is that of boil-off calorimetry, using liquid nitrogen or any other suitable liquid that boils at a desired temperature below ambient temperature. Comparative rates of flow of heat through the thicknesses of the specimens (heat-leak rates) and apparent-thermal-conductivity values are obtained from tests of specimens. Absolute values of heat-leak rates and apparent thermal conductivities are computed from a combination of (1) the aforementioned comparative values and (2) calibration factors obtained by testing reference specimens of materials that have known thermal-insulation properties. The apparatus includes a full complement of temperature sensors, a vacuum pump and chamber, a monitoring and control system, and tools and fixtures that enable rapid and reliable installation and removal of specimens. A specimen is installed at the bottom of the vacuum chamber, and a cold-mass assembly that includes a tank is lowered into position above and around the specimen (see figure). A spring-based compensating fixture helps to ensure adequate thermal contact with possibly irregular specimen surfaces. For a high-compression test, the springs can be replaced with spacers. A flat circular load cell at the bottom of the chamber measures the compressive load on the specimen. Once the desired compressive-load, temperature, and vacuum/gas-filling conditions are established, testing begins. During a test, all measurements are recorded by use of a portable data-acquisition system and a computer. The total heat-leak rate is measured and calculated as the boil-off flow rate multiplied by the latent heat of vaporization. The parasitic heat leak (to the side of the specimen and to the top and side of the cold-mass tank) is reduced to a small fraction of the total heat leak by use of a combination of multilayer-insulation (MLI) shield rings, reflective film, a fiberglass/epoxy centering ring, and a bulk fill of aerogel beads. This combination eliminates the need for a cryogenic guard chamber used in a typical prior apparatus to reduce the parasitic heat leak.

Fesmire, James E.↗

Elastomeric Seal Performance after Terrestrial Ultraviolet Radiation Exposure

Ultraviolet radiation was evaluated to determine its negative effects on the performance of elastomeric gas pressure seals. The leak rates of the silicone elastomer S0383-70 O-ring test articles were used to quantify the degradation of the seals after exposure to vacuum-ultraviolet and/or middle-to-near-ultraviolet wavelength radiation. Three groups of seals were exposed in terrestrial facilities to 115-165 nm wavelength radiation, 230-500 nm wavelength radiation, or both spectrums, for an orbital spaceflight equivalent of 125 hours. The leak rates of the silicone elastomer S0383-70 seals were quantified and compared to samples that received no radiation. Each lot contained six samples and statistical t-tests were used to determine the separate and combined influences of exposure to the two wavelength ranges. A comparison of the mean leak rates of samples exposed to 115-165 nm wavelength radiation to the control specimens showed no difference, suggesting that spectrum was not damaging. The 230-500 nm wavelength appeared to be damaging, as the mean leak rates of the specimens exposed to that range of wavelengths, and those exposed to the combined 115-165 nm and 230-500 nm spectrums, were significantly different from the leak rates of the control specimens. Most importantly, the test articles exposed to both wavelength spectrums exhibited mean leak rates two orders of magnitude larger than any other exposed specimens, which suggested that both wavelength spectrums are important when simulating the orbital environment.

leakage↗

Measuring Small Leak Holes

Hole sizes deduced from pressure measurements. Measuring apparatus consists of pitot tube attached to water-filled manometer. Compartment tested is pressurized with air. Pitot probe placed at known distance from leak. Dynamic pressure of jet measured at that point and static pressure measured in compartment. Useful in situations in which small leaks are tolerable but large leaks are not.

Koch, D. E.↗

Reusable Solid Rocket Motor Nozzle Joint-4 Thermal Analysis

This study provides for development and test verification of a thermal model used for prediction of joint heating environments, structural temperatures and seal erosions in the Space Shuttle Reusable Solid Rocket Motor (RSRM) Nozzle Joint-4. The heating environments are a result of rapid pressurization of the joint free volume assuming a leak path has occurred in the filler material used for assembly gap close out. Combustion gases flow along the leak path from nozzle environment to joint O-ring gland resulting in local heating to the metal housing and erosion of seal materials. Analysis of this condition was based on usage of the NASA Joint Pressurization Routine (JPR) for environment determination and the Systems Improved Numerical Differencing Analyzer (SINDA) for structural temperature prediction. Model generated temperatures, pressures and seal erosions are compared to hot fire test data for several different leak path situations. Investigated in the hot fire test program were nozzle joint-4 O-ring erosion sensitivities to leak path width in both open and confined joint geometries. Model predictions were in generally good agreement with the test data for the confined leak path cases. Worst case flight predictions are provided using the test-calibrated model. Analysis issues are discussed based on model calibration procedures.

Clayton, J. Louie↗

Passive Leak Detection Using Commercial Hydrogen Colorimetric Indicator

Element One, Inc. (www.elem.com), a small business with in Boulder, CO, has been developing hydrogen detection technology based upon a highly selective colorimetric indicator. In its native state, the indicator pigment is a pale gray color, but becomes black upon exposure to hydrogen. The colorimetric change can be readily observed by the naked eye without the need for supplemental electronics or other hardware. Recently, the colorimetric indicator was integrated into a pliable, self-adhesive tape that can readily wrap around pneumatic fittings to serve as a hydrogen leak detector. A prototype version of the Element One indicator tape was tested within an NREL hydrogen system and successfully identified the unexpected presence of a small leak; a summary document for this case study is presented in Appendix 1. The tape was subsequently configured into 10-foot rolls as a product prototype that has just recently been commercialized and marketed under the tradename DetecTape(R). Figure 1 shows the commercial version of DetecTape along with an indicator sample in its native state and one that had been exposed to hydrogen. DetecTape is a self-adhesive silicone-based tape impregnated with a proprietary hydrogen-sensitive indicator based on transition metal oxides. A length of the tape can be cut from the roll and stretched by a factor of two or three times around a fitting. Due to the self-adhesive property of the tape, this provides a tight seal around the fitting. The seal is not hermetic, and is not intended to prevent the release of a leaking gas. However, a portion of the hydrogen leaking from a wrapped fitting will pass through the tape and react with the active indicator impregnated within the tape, thereby inducing blackening.

08 HYDROGEN↗

Solid-State Mixed-Potential Electrochemical Sensors for Natural Gas Leak Detection and Quality Control (Final Technical Report)

Mitigation of methane emissions are a critical factor to limiting the impact of the natural gas industry on global climate change. Throughout the period of 2020-2024, the University of New Mexico and its commercialization partner and subcontractor, SensorComm Technologies, Inc. (SCT), have worked together to develop a low-cost Artificial Intelligence (AI)-driven Internet of Things (IoT)-based multi-gas sensor platform for methane emissions detection. In the final year of the project, we extended this work to include hydrogen detection in support of a transition to a hydrogen economy where hydrogen could be transported through existing natural gas infrastructure. Mixed potential electrochemical sensors were first prototyped by ceramic additive manufacturing and then transitioned to conventional ceramic manufacturing tape casting and screen-printing technologies in preparation for mass production. Demonstrated limits of detection of 5 ppm of methane in natural gas and 1 ppm of hydrogen were measured. These limits of detection are among the lowest of solid-state electrochemical sensors that have been reported in the literature or available in the industry. Machine learning algorithms were developed to identify natural gas mixtures with > 98% accuracy level and quantify methane concentrations at 97% accuracy. The presence of hydrogen could also be identified, and its concentration quantified at these accuracy levels. These algorithms were optimized for running on portable computing hardware which enabled > 1 Hz processing rates. A portable packaged IoT system was integrated with the electrochemical sensor in collaboration with SCT. The package consists of readout electronics with < 1 mV resolution, sensor temperature control, and data transmission over cellular wireless and/or Wi-Fi networks. Field testing was performed in two rounds at Colorado State University’s Methane Emissions Technology Evaluation Center (CSU METEC). The first round of testing demonstrated successful measurements of methane from an underground natural gas leak of 20 standard liters per minute (SLPM), which agreed with previously published literature using more sophisticated and expensive analytical equipment. The second round of testing showed that an above ground leak of 2 SLPM of hydrogen could be detected at 32 ft. This project has resulted in six published peer reviewed journal articles, over ten presentations at professional conferences, and one full patent application filed in 2023. Future work on this project includes increased sensitivity, higher production yields, and applications in the hydrogen safety and flare emissions monitoring spaces.

03 NATURAL GAS↗

Defense Waste Processing Facility Canister Closure Weld Current Validation Testing

Two closure welds on filled Defense Waste Processing Facility (DWPF) canisters failed to be within the acceptance criteria in the DWPF operating procedure SW4-15.80-2.3 (1). In one case, the weld heat setting was inadvertently provided to the canister at the value used for test welds (i.e., 72%) and this oversight produced a weld at a current of nominally 210 kA compared to the operating procedure range (i.e., 82%) of 240 kA to 263 kA. The second weld appeared to experience an instrumentation and data acquisition upset. The current for this weld was reported as 191 kA. Review of the data from the Data Acquisition System (DAS) indicated that three of the four current legs were reading the expected values, approximately 62 kA each, and the fourth leg read zero current. Since there is no feasible way by further examination of the process data to ascertain if this weld was actually welded at either the target current or the lower current, a test plan was executed to provide assurance that these Nonconforming Welds (NCWs) meet the requirements for strength and leak tightness. Acceptance of the welds is based on evaluation of Test Nozzle Welds (TNW) made specifically for comparison. The TNW were nondestructively and destructively evaluated for plug height, heat tint, ultrasonic testing (UT) for bond length and ultrasonic volumetric examination for weld defects, burst pressure, fractography, and metallography. The testing was conducted in agreement with a Task Technical and Quality Assurance Plan (TTQAP) (2) and applicable procedures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Status of Graphite Oxidation Work

Data were developed to compare the extent of structural damage associated with high temperature exposure to an air leak. Two materials, NBG-18 graphite and unpurified PCEA graphite have been tested as of this report. The scope was limited to isothermal oxidation at a single temperature, 750°C. Ambient post-oxidation compression strength testing was performed for three levels of burn off (1%, 5%, and 10% mass loss) for two leak scenarios: 100% air and 10% air in helium. Temperature, gas flow, and dynamic mass loss oxidation conditions were monitored and recorded for each sample. The oxidation period was controlled with flow of inert gas during the thermal ramp and upon cool down with a constant 10 liter per minute flow maintained throughout furnace operation. Compressive strengths of parallel un-oxidized samples were tested to assess the relative mass loss effects. In addition to baseline samples matching the un-oxidized dimensions of the oxidized samples, two sets of mechanically reduced samples were prepared. One set was trimmed to achieve the desired mass loss by removing an effectively uniform depth from the geometric surface of the sample. The other set was cored to produce a full penetration axial hole down the center of each sample.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrity Assessment of Hanford 242-A Evaporator Facility E-A-1 Re-boiler Vessel via Fluorescein Liquid Tracer Test Methods - 17357

The 242-A Evaporator Facility is critical to the United States Department of Energy's (DOE) Hanford Site clean-up mission due to limited space within the existing Double-Shell Tanks (DSTs) used to store nuclear and chemical waste until future processing. The 242-A Evaporator Facility is currently the sole waste volume reduction process used at Hanford, and the E-A-1 Re-boiler is essential to the Evaporator process. Due to the potential for cross-contamination between the Re-boiler tubes through which waste passes and the tube sheets of uncontaminated steam, an assessment of the Re-boiler vessel's integrity is required for continuing operations of the facility. In order to meet these requirements, an independent integrity assessment was designed to use fluorescein liquid tracer (LT) to verify the leak-tightness of the Re-boiler vessel in accordance with Washington River Protection Solutions, LLC (WRPS) tightness test standards, as well as, the ASME Boiler and Pressure Vessel (B and PV) Code, Section III, Division 1, NB-6300. LT test methodologies were evaluated and determined to be appropriate for a vessel with restricted access, such as the E-A-1 Re-boiler, as it provided the needed sensitivity, reliability, and cost; as well as, exceeded the leak-tightness specifications required by both WRPS and ASME B and PV Code standards. The integrity test requires water laced with fluorescein be circulated through the waste processing loop of the 242-A Evaporator and samples of steam condensate be collected and analyzed for traces of fluorescein to determine leak-tightness. Liquid condensate sampling was conducted prior to and during testing and the samples were analyzed for fluorescein tracer to determine the amount of fluorescein that flowed out of the tubes of the Re-boiler into the steam side of the vessel. Given the established criteria for 'leak-tight,' test results determined that the Re-boiler passed the integrity assessment. After further scrutiny of the 2014 test and data results, it was determined that although the Re-boiler was 'leak-tight,' as established by the test criteria, there was concern of future leakage. The DOE and the DOE Office of River Protection (ORP) requested that WRPS repeat the integrity assessment in two and a half years to determine if the potential leak was growing, which could threaten continuing operations of the 242-A Evaporator. The 2017 test has been redesigned using lessons learned from the 2014 test and was modified to account for ergonomic and safety considerations, ease of repeatability, and accuracy of results. The liquid tracer methodology and test plan developed for the Re-boiler will continue to be implemented in 5 year increments to monitor current and future integrity. The method may also prove useful for other aging components across the Hanford Site, where appropriate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Leak Detection and Sensor Importance Within a Solvent Extraction Process Abstract

In anticipation of the Special Nuclear Material test bed (Beartooth), Idaho National Laboratory has developed a smaller, multi-sensor system for analyzing the solvent extraction process. These systems will allow for research into nuclear fuel processing operations. The multi-sensor system consists of a row of centrifugal contactors and allows for measurement sources that are not traditionally used in the solvent extraction process to be explored including temperature, vibration, acoustics, pH, color, flow, and motor current. Currently, the solvent extraction process is very labor intensive and requires vigilant operators to identify the occurrence of leaks, which can be common during startup or after any change to the system. This study aims to locate leaks using non-traditional measurement sources then to identify which signals were of greatest importance in making this classification using Local Interpretable Model-agnostic Explanations. These results can be used to help solvent extraction process operators detect leaks and to inform future test beds designers to which sensors contain relevant, actionable information in this scenario.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Cryogenic Insulation Systems

New materials in recent decades have enabled advances in thermal insulation systems for storage and transfer of cryogens. To preserve the cold and achieve efficient cryogenic systems, a combination of materials, testing, and engineering is required. The total heat leak into any cryogenic assembly is comprised of three main parts: 1) heat leak through the insulation, 2) heat leak through the support structures, and 3) heat leak attributed to piping penetrations and feedthroughs (and their negative effects on the insulation). This "cold triangle" approach provides a basis for evaluating performance benefits of new materials and analyzing the cost effectiveness in overall system design. Provided are thermophysical data for aerogels, aerogel composites, novel multilayered composites, and glass bubbles for standard test conditions of 293 K and 78 K under conditions from high vacuum to ambient pressure. Examples of cryogenic storage tanks show the relative importance of both insulation and structural materials for achieving designs of highest energy efficiency.

Multilayer Insulation↗