Stress Corrosion Evaluation of Inconel X-750 for the International Space Station Environmental Control and Life Support System

Inconel X-750 alloy was evaluated for stress corrosion in support of the International Space Station Environmental Control and Life Support System. Round tensile specimens that were obtained from 0.25 in thick material successfully completed 365 days of exposure to baseline pretreat, baseline brine, alternate pretreat, alternate brine, and 3.5% NaCl alternate immersion without any failures at stresses of up to 90% of the yield strength. Posttest evaluations consisting of metallography and tensile testing did not indicate stress corrosion susceptibility.

International Space Station↗

Summary of Resources for the International Space Station Environmental Control and Life Support System For Core Complete Modules

The Core Complete Environmental Control and Life Support (ECLS) System for the International Space Station (ISS) will consist of components and subsystems in both the United States (U.S.) and International Partner elements which together will perform the functions of Temperature and Humidity Control (THC), Atmosphere Control and Supply (ACS), Atmosphere Revitalization (AR), Water Recovery and Management (WRM), Fire Detection and Suppression (FDS), and Vacuum System (VS) for the station. Due to limited resources available on ISS, detailed attention is given to minimizing and tracking all resources associated with all systems, beginning with estimates during the hardware development phase through measured actuals when flight hardware is built and delivered. A summary of resources consumed by the addition of future U.S. ECLS system hardware to get to Core Complete is presented, including launch weight, average continuous and peak power loads, on-orbit volume and resupply logistics.

Williams, David E.↗

Environmental Controls and Life Support System (ECLSS) Design for a Space Exploration Vehicle (SEV)

Engineers at Johnson Space Center (JSC) are developing an Environmental Control and Life Support System (ECLSS) design for the Space Exploration Vehicle (SEV). The SEV will aid to expand the human exploration envelope for Geostationary Transfer Orbit (GEO), Near Earth Object (NEO), or planetary missions by using pressurized surface exploration vehicles. The SEV, formerly known as the Lunar Electric Rover (LER), will be an evolutionary design starting as a ground test prototype where technologies for various systems will be tested and evolve into a flight vehicle. This paper will discuss the current SEV ECLSS design, any work contributed toward the development of the ECLSS design, and the plan to advance the ECLSS design based on the SEV vehicle and system needs.

Stambaugh, Imelda↗

Space Suit Portable Life Support System (PLSS) 2.0 Unmanned Vacuum Environment Testing

For the first time in more than 30 years, an advanced space suit Portable Life Support System (PLSS) design was operated inside a vacuum chamber representative of the flight operating environment. The test article, PLSS 2.0, was the second system-level integrated prototype of the advanced PLSS design, following the PLSS 1.0 Breadboard that was developed and tested throughout 2011. Whereas PLSS 1.0 included five technology development components with the balance the system simulated using commercial-off-the-shelf items, PLSS 2.0 featured first generation or later prototypes for all components less instrumentation, tubing and fittings. Developed throughout 2012, PLSS 2.0 was the first attempt to package the system into a flight-like representative volume. PLSS 2.0 testing included an extensive functional evaluation known as Pre-Installation Acceptance (PIA) testing, Human-in-the-Loop testing in which the PLSS 2.0 prototype was integrated via umbilicals to a manned prototype space suit for 19 two-hour simulated EVAs, and unmanned vacuum environment testing. Unmanned vacuum environment testing took place from 1/9/15-7/9/15 with PLSS 2.0 located inside a vacuum chamber. Test sequences included performance mapping of several components, carbon dioxide removal evaluations at simulated intravehicular activity (IVA) conditions, a regulator pressure schedule assessment, and culminated with 25 simulated extravehicular activities (EVAs). During the unmanned vacuum environment test series, PLSS 2.0 accumulated 378 hours of integrated testing including 291 hours of operation in a vacuum environment and 199 hours of simulated EVA time. The PLSS prototype performed nominally throughout the test series, with two notable exceptions including a pump failure and a Spacesuit Water Membrane Evaporator (SWME) leak, for which post-test failure investigations were performed. In addition to generating an extensive database of PLSS 2.0 performance data, achievements included requirements and operational concepts verification, as well as demonstration of vehicular interfaces, consumables sizing and recharge, and water quality control.

Watts, Carly↗

Integrated Oxygen Flow Meter/Heat Exchanger for Portable Life Support Systems

Space suits for future exploration missions will have multi-mission goals with new and challenging requirements for the portable life support system (PLSS). In particular, the space suit ventilation loop requires cooling and flow measurement components that must meet specifications that go well beyond the capabilities of the components used for the existing Extravehicular Mobility Unit. The flow meter must have high measurement accuracy over a wide flow range, compatibility with pure oxygen, low pressure losses, and very compact size. The heat exchanger that cools the ventilation loop must be built from materials that are compatible with the liquid cooling loop, and it must provide efficient gas cooling in a small package across conditions ranging from normal suit pressure to elevated pressure. This paper describes the development of a novel device that combines the flow measurement and cooling functions in a single, compact flow meter/heat exchanger (FMHX). We have developed design methods that enable us to assess trade-offs, optimize performance, and specify the design of an FMHX that meets the requirements and constraints for operation in future PLSSs. We used empirical design correlations combined with computational fluid dynamics analysis to design the FMHX design. Data from tests of a proof-of-concept FMHX validate the design methods and show that the device meets all design requirements. We used the results from these tests to refine the design parameters and predict performance of an optimized, prototype FMHX.

Izenson, Michael G.↗

Space Suit Portable Life Support System Oxygen Regulator History, Development, & Testing Results

An oxygen regulator has been in development for the Exploration Extravehicular Mobility Unit (xEMU) Portable Life Support System (PLSS). The regulator provides the necessary oxygen pressure control for the crew member during prebreathe, Extra-Vehicular Activity (EVA), post EVA airlock operations, and Decompression Sickness (DCS) treatment. It has been over four decades since a new spacesuit oxygen regulator has been designed. The regulator and EMU that is presently used on the International Space Station (ISS) was developed for the space shuttle program without any significant changes made throughout its service life. The xEMU spacesuit oxygen regulator is based on the previous EMU Secondary Oxygen Pack (SOP). The new design integrates numerous improvements and changes including an innovative approach to regulator architecture, a more robust first stage pressure sensing mechanism, digital actuation control, and electronic pressure sensing. These upgrades replace manual control linkages, physical gauges, and enable infinitely variable pressure set points. The new setpoints can decrease prebreathe time and make in suit DCS treatment possible. Throughout its four iterations design concerns have been addressed, safety features have been added, and the envelope of the regulator designed to fit inside the xEMU PLSS package. This paper will review the history, design, testing, and lessons learned during the development of the xEMU PLSS Oxygen Regulator.

Ryan Eric Ogilvie↗

Space Suit Portable Life Support System Fastener and Insert Summary, Issues, and Testing Results

Fasteners are included in every assembly on the Exploration External Mobility Unity Portable Life Support System (xEMU PLSS). However, fasteners and inserts have been the cause of many issues seen on the PLSS during development; furthermore, inserts with thermoplastics are not very well understood. The materials used in the PLSS are sometimes softer and lighter weight metals or thermoplastics which require the installation of inserts to improve the interface strength. In addition, space flight requirements call out the need for an additional running/locking torque, so they do not detach in case of failure of the final torque. The xEMU PLSS has experienced various issues with fasteners and inserts, from the bolt binding in an insert or the running torque failing prematurely. A study has been completed to address the running torque life problem. This study compares the insert and locking feature combinations to determine the combination which maximizes life. The study found that using a locking patch with an insert fails after the first installation. Therefore, it is no longer recommended to use a locking patch fastener with an insert for future installments. For the bolt binding issue, inserts have been installed too deep and have caused the bolt to bind near the final threads of the inserts where the hole is not tapped deep enough. Thermoplastics, on the other end, can either use standard helical inserts or heat set inserts. Another study was performed using tangless inserts and heat inserts installed in thermoplastics to quantify the expected pull-out strength for various insert installation parameters (insert type, temperature, and pressure). This paper will review the issues and lessons learned with fasteners on the xEMU PLSS, provide results of a locking feature study, and provide results and recommended installation settings from a heat insert study.

Ryan Ogilvie↗

International Space Station Environmental Control and Life Support System On-Orbit Station Development Test Objective Status

The International Space Station (ISS) Environmental Control and Life Support (ECLS) system includes regenerative and non-regenerative technologies that provide the basic life support functions to support the crew, while maintaining a safe and habitable shirtsleeve environment. This paper provides a summary of the ECLS System On-Orbit Station Development Test Objective (SDTO) status from the start of assembly until the end of February 2003.

Williams, David E.↗

A closed life-support system for space colonies

In 1975, a system design study was performed to examine a completely self-contained system for a permanent colony of 10,000 inhabitants in space. Fundamental to this design was the life support system. Since resupply from earth is prohibitive in transportation costs, it was decided to use a closed system with the initial supply of oxygen coming from processing of lunar ores, and the supply of carbon, nitrogen and hydrogen from earth. The problem of life support was treated starting with the nutritional and metabolic requirements for the human population, creating a food and water chain sufficient to supply these demands, adding the additional requirements for the animal and plant sources in the food chain, feeding back useful waste products, supplying water as required from different sources, and closing the loop by processing organic wastes into CO2. This concept places the burden of the system upon plants for O2 generation and waste processing the CO2 generation.

Johnson, R. D.↗

A gas flow indicator for portable life support systems

A three-part program was conducted to develop a gas flow indicator (GFI) to monitor ventilation flow in a portable life support system. The first program phase identified concepts which could potentially meet the GFI requirements. In the second phase, a working breadboard GFI, based on the concept of a pressure sensing diaphragm-aneroid assembly connected to a venturi, was constructed and tested. Extensive testing of the breadboard GFI indicated that the design would meet all NASA requirements including eliminating problems experienced with the ventilation flow sensor used in the Apollo program. In the third program phase, an optimized GFI was designed by utilizing test data obtained on the breadboard unit. A prototype unit was constructed using prototype materials and fabrication techniques, and performance tests indicated that the prototype GFI met or exceeded all requirements.

Bass, R. L., III↗

Utilization of potatoes for life support systems in space. III - Productivity at successive harvest dates under 12-h and 24-h photoperiods

Efficient crop production for controlled ecological life support systems requires near-optimal growing conditions with harvests taken when production per unit area per unit time is maximum. This maximum for potato was determined using data on Norland plants which were grown in walk-in growth rooms under 12-h and 24-h photoperiods at 16 C. Results show that high tuber production can be obtained from potatoes grown under a continuous light regime. The dry weights (dwt) of tuber and of the entire plants were found to increase under both photoperiods until the final harvest date (148 days), reaching 5732 g tuber dwt and 704 g total dwt under 12-h, and 791 g tuber dwt and 972 g total dwt under 24-h.

Wheeler, Raymond M.↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A pervious TCV version with a linear actuator and diverter valve has been tested extensively to attempt to control the flow accurately. The previous TCV diverter valve has a non-linear flow response relative to valve position and has struggled to accurately meet the setpoints desired for precision thermal control. While many diverter valve design variations have been attempted, previous designs have all had difficulty in meeting set points. Additionally, high precision machining is required for these diverter valves to create a metal-on-metal seal which has its own drawbacks and doesn’t always meet requirements for internal leakage. This metal compression seal also requires stalling the linear actuator to load the seal in compression or tension which has demonstrated valve sticking failures when stalled. The xEMU PLSS TCV implements a new approach and design for a TCV which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. A new geometric design modification to the ball outlet can create a set-able orifice like hole which is more predictable at controlling flow than using an annulus with the previous diverter valve. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A previous TCV version with a linear actuator and diverter valve has been tested to attempt to control the flow accurately. The previous valve has a non-linear flow response relative to valve position and has struggled to meet the setpoints desired for precise thermal control. While many diverter valve design variations have been attempted, all previous designs have had difficulty meeting set points. Additionally, high precision machining is required to create a metal-on-metal seal which has its own drawbacks and does not always meet requirements for internal leakage. This metal seal also requires stalling a linear actuator to load the seal in compression or tension which has caused sticking failures when stalled. A new approach and design for a TCV has been developed which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. The ball outlet has a unique geometric design to create a set-able orifice like hole which is more predictable at controlling flow. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A previous TCV version with a linear actuator and diverter valve has been tested to attempt to control the flow accurately. The previous valve has a non-linear flow response relative to valve position and has struggled to meet the setpoints desired for precise thermal control. While many diverter valve design variations have been attempted, all previous designs have had difficulty meeting set points. Additionally, high precision machining is required to create a metal-on-metal seal which has its own drawbacks and does not always meet requirements for internal leakage. This metal seal also requires stalling a linear actuator to load the seal in compression or tension which has caused sticking failures when stalled. A new approach and design for a TCV has been developed which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. The ball outlet has a unique geometric design to create a set-able orifice like hole which is more predictable at controlling flow. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

DAWN (Design Assistant Workstation) for advanced physical-chemical life support systems

This paper reports the results of a project supported by the National Aeronautics and Space Administration, Office of Aeronautics and Space Technology (NASA-OAST) under the Advanced Life Support Development Program. It is an initial attempt to integrate artificial intelligence techniques (via expert systems) with conventional quantitative modeling tools for advanced physical-chemical life support systems. The addition of artificial intelligence techniques will assist the designer in the definition and simulation of loosely/well-defined life support processes/problems as well as assist in the capture of design knowledge, both quantitative and qualitative. Expert system and conventional modeling tools are integrated to provide a design workstation that assists the engineer/scientist in creating, evaluating, documenting and optimizing physical-chemical life support systems for short-term and extended duration missions.

Rudokas, Mary R.↗