Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Mitigation of Beam Losses in LANSCE Linear Accelerator

Suppression of beam losses is essential for successful operation of high-intensity accelerator facility. The LANSCE accelerator started routine operation in 1972 as a 0.8 MW average proton beam power facility for meson physics research, and delivered highpower beam for a quarter century. The accelerator currently delivers 100 MeV proton beam to Isotope Production Facility (IPF) and 800 MeV H- beams to various experimental areas. The accelerator is equipped with two independent injectors for H + and H - beams, merging at the entrance of a 201.25 MHz Drift Tube Linac (DTL). The DTL performs acceleration up to the energy of 100 MeV. After the DTL, the Transition Region beamline directs a 100 MeV proton beam to the Isotope Production Facility, while the H - beam is accelerated up to the final energy of 800 MeV in an 805- MHz Coupled Cavity Linac. The H - beams, created with different time structure by a lowenergy chopper, are distributed in the Switch Yard (SY) to four experimental areas: the Lujan Neutron Scattering Center equipped with a Proton Storage Ring (PSR), the Weapons Neutron Research facility (WNR), the Proton Radiography facility (pRad), and the Ultra-Cold Neutron facility (UCN). Multi-beam operation requires careful control of accelerator tune to minimize beam losses. In this paper we review main effects affecting beam losses in LANSCE linear accelerator and discuss methods to reduce them.

43 PARTICLE ACCELERATORS↗

Microbially mediated mechanisms underlie soil carbon accrual by conservation agriculture under decade-long warming

Increasing soil organic carbon (SOC) in croplands by switching from conventional to conservation management may be hampered by stimulated microbial decomposition under warming. Here, we test the interactive effects of agricultural management and warming on SOC persistence and underlying microbial mechanisms in a decade-long controlled experiment on a wheat-maize cropping system. Warming increased SOC content and accelerated fungal community temporal turnover under conservation agriculture (no tillage, chopped crop residue), but not under conventional agriculture (annual tillage, crop residue removed). Microbial carbon use efficiency (CUE) and growth increased linearly over time, with stronger positive warming effects after 5 years under conservation agriculture. According to structural equation models, these increases arose from greater carbon inputs from the crops, which indirectly controlled microbial CUE via changes in fungal communities. As a result, fungal necromass increased from 28 to 53%, emerging as the strongest predictor of SOC content. Collectively, our results demonstrate how management and climatic factors can interact to alter microbial community composition, physiology and functions and, in turn, SOC formation and accrual in croplands.

59 BASIC BIOLOGICAL SCIENCES↗

Spectroscopy of {Lambda} hypernuclei in the (e, e'K{sup +}) reaction at Jefferson Lab

The coincidence experiment E01-011 (HKS), conducted in Hall C at Jefferson Laboratory in fall 2005, represents a new generation of high resolution {Lambda} hypernuclei spectroscopy experiments. It exploits the benefits of the associated electroproduction mechanism via the (e, e'K{sup +}) reaction. Compared with the widely studied meson-induced reactions, the higher quality quasi-continuous electron beam produces the potential for high resolution energy spectra. Further, it provides information complementary to meson-induced reactions: light neutron-rich and mirror hypernuclei, enhanced population of states accessible by spin-flip channels. The newly introduced tilt method of the electron spectrometer (ENGE) greatly reduced the rate of the background electrons due to Bremsstrahlung and Moeller scattering. A brand new high resolution kaon spectrometer (HKS) together with a sophisticated detector package yielded excellent PID and momentum resolution. This resulted in quality missing mass spectra with energy resolution of approximately 400-500 keV (FWHM), an unprecedented value in hypernuclear reaction spectroscopy. The experiment measured the spectra of exotic neutron rich and mirror {Lambda} hypernuclei {sub {Lambda}}{sup 7}He, {sub {Lambda}}{sup 12}B, {sub {Lambda}}{sup 28}Al with high statistics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical pulse evolution in the Stanford free-electron laser and in a tapered wiggler

The Stanford free electron laser (FEL) oscillator is driven by a series of electron pulses from a high-quality superconducting linear accelerator (LINAC). The electrons pass through a transverse and nearly periodic magnetic field, a 'wiggler', to oscillate and amplify a superimposed optical pulse. The rebounding optical pulse must be closely synchronized with the succession of electron pulses from the accelerator, and can take on a range of structures depending on the precise degree of synchronism. Small adjustments in desynchronism can make the optical pulse either much shorter or longer than the electron pulse, and can cause significant subpulse structure. The oscillator start-up from low level incoherent fields is discussed. The effects of desynchronism on coherent pulse propagation are presented and compared with recent Stanford experiments. The same pulse propagation effects are studied for a magnet design with a tapered wavelength in which electrons are trapped in the ponderomotive potential.

Colson, W. B.↗

Using Dark Matter Haloes to Learn about Cosmic Acceleration: A New Proposal for a Universal Mass Function

Structure formation provides a strong test of any cosmic acceleration model because a successful dark energy model must not inhibit or overpredict the development of observed large-scale structures. Traditional approaches to studies of structure formation in the presence of dark energy or a modified gravity implement a modified Press-Schechter formalism, which relates the linear overdensities to the abundance of dark matter haloes at the same time. We critically examine the universality of the Press-Schechter formalism for different cosmologies, and show that the halo abundance is best correlated with spherical linear overdensity at 94% of collapse (or observation) time. We then extend this argument to ellipsoidal collapse (which decreases the fractional time of best correlation for small haloes), and show that our results agree with deviations from modified Press-Schechter formalism seen in simulated mass functions. This provides a novel universal prescription to measure linear density evolution, based on current and future observations of cluster (or dark matter) halo mass function. In particular, even observations of cluster abundance in a single epoch will constrain the entire history of linear growth of cosmological of perturbations.

Prescod-Weinstein, Chanda↗

Megavoltage Image-Based Dynamic Multileaf Collimator Tracking of a NiTi Stent in Porcine Lungs on a Linear Accelerator

Purpose: To investigate the accuracy and potential limitations of MV image-based dynamic multileaf collimator (DMLC) tracking in a porcine model on a linear accelerator. Methods and Materials: A thermo-expandable NiTi stent designed for kilovoltage (kV) X-ray visualization of lung lesions was inserted into the bronchia of three anaesthetized Goettingen minipigs. A four-dimensional computed tomography scan was used for planning a five-field conformal treatment with circular multileaf collimator (MLC) apertures. A 22.5 Gy single fraction treatment was delivered to the pigs. The peak-to-peak stent motion was 3 to 8 mm, with breathing periods of 1.2 to 4 s. Before treatment, X-ray images were used for image-guided setup based on the stent. During treatment delivery, continuous megavoltage (MV) portal images were acquired at 7.5 Hz. The stent was segmented in the images and used for continuous adaptation of the MLC aperture. Offline, the tracking error in beam's eye view of the treatment beam was calculated for each MV image as the difference between the MLC aperture center and the segmented stent position. The standard deviations of the systematic error {Sigma} and the random error {sigma} were determined and compared with the would-be errors for a nontracking treatment with pretreatment image-guided setup. Results: Reliable stent segmentation was obtained for 11 of 15 fields. Segmentation failures occurred when image contrast was dominated by overlapping anatomical structures (ribs, diaphragm) rather than by the stent, which was designed for kV rather than MV X-ray visibility. For the 11 fields with reliable segmentation, {Sigma} was 0.5 mm/0.4 mm in the two imager directions, whereas {sigma} was 0.5 mm/1.1 mm. Without tracking, {Sigma} and {sigma} would have been 1.7 mm/1.4 mm and 0.8 mm/1.4 mm, respectively. Conclusion: For the first time, in vivo DMLC tracking has been demonstrated on a linear accelerator showing the potential for improved targeting accuracy. The study mimicked the envisioned patient workflow of future patient treatments. Clinical implementation of MV image-based tracking would require markers designed for MV visibility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-21: Clinical Evaluation of Surface Scanning Systems in Different Treatment Locations

Purpose: To reduce imaging dose in fractionated IGRT, the ability of optical surface imaging systems (OSIS) to detect setup errors was tested. Therefore, clinical studies to evaluate for different treatment locations setup corrections derived by OSIS in comparison with x-ray image guidance in fractionated radiation therapy was performed. Methods: The setup correction accuracy of an OSIS system (AlignRT, VisionRT, London, UK) will be analysed for the 4 tumour locations Pelvis, Upper Abdomen, Thorax and Breast, 20 patients for each location in comparison to a different system (Sentinel, C-RAD, SE). For each patient, the setup corrections of the cone-beam computed tomography (CBCT) of an Elekta Versa HD linear accelerator (Elekta, Crawley, UK) is considered as gold-standard and then compared with those of the OSIS for the first ten fractions retrospectively. There were no clinical decisions made based on the surrogate system. For the OSIS, the reference surface is highly important as it represents the actual ground truth. It can be obtained either with the system itself or the surface structure delineated in the planning CT can be imported via DICOM interface. In this paper, the first results for the treatment region thorax are presented. The reference image modalities were compared. Results: Table 1 displays the difference between the setup corrections obtained with OSIS and CBCT in lateral (LAT), longitudinal (LNG) and vertical (VRT) direction for the DICOM reference image. While the median deviations are within a few millimeters, some outliers showed large deviations. Generally, the mean deviation as well as the spread was smallest in lateral and largest in vertical direction. Conclusion: Although the system allows fast, simple and non-invasive determination of setup corrections, it should be evaluated treatment region dependant. Therefore, the study is ongoing. The application of OSIS may help to reduce the imaging dose for the patient. We gratefully acknowledge the support by our colleagues from the Radiological University Clinic Heidelberg, where the study was performed. This work was funded by the Federal Ministry of Education and Research (BMBF) Germany, grant number 01IB13001B.

60 APPLIED LIFE SCIENCES↗

Self-consistent core-pedestal transport simulations with neural network accelerated models

Fusion whole device modeling simulations require comprehensive models that are simultaneously physically accurate, fast, robust, and predictive. In this paper we describe the development of two neural-network (NN) based models as a means to perform a snon-linear multivariate regression of theory-based models for the core turbulent transport fluxes, and the pedestal structure. Specifically, we find that a NN-based approach can be used to consistently reproduce the results of the TGLF and EPED1 theory-based models over a broad range of plasma regimes, and with a computational speedup of several orders of magnitudes. These models are then integrated into a predictive workflow that allows prediction with self-consistent core-pedestal coupling of the kinetic profiles within the last closed flux surface of the plasma. Finally, the NN paradigm is capable of breaking the speed-accuracy trade-off that is expected of traditional numerical physics models, and can provide the missing link towards self-consistent coupled core-pedestal whole device modeling simulations that are physically accurate and yet take only seconds to run.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anisotropic compression of a synthetic potassium aluminogermanate zeolite with gismondine topology

Compression behavior of a potassium aluminogermanate with a gismondine framework topology (K-AlGe-GIS) was studied using in-situ high-pressure synchrotron X-ray powder diffraction. In contrast to the potassium gallosilicate analogue (K-GaSi-GIS), no elastic anomaly due to pressure-induced hydration and/or cation relocation was observed in K-AlGe-GIS. The Birch-Murnaghan fit to the pressure-volume data results in a bulk modulus of B{sub 0} = 31(1) GPa. The derived linear-axial compressibilities (i.e., {beta}{sub a} = 0.0065(5) GPa{sup -1}, {beta}{sub b} = 0.0196(4) GPa{sup -1}, {beta}{sub c} = 0.0081(7) GPa{sup -1}) indicate that the b-axis, normal to the 8-ring channels, is about three times more compressible than the a and c axes, parallel to the elliptical 8-ring channels. As a consequence a gradual flattening of the so-called 'double crankshaft' structural building units of the gismondine framework is observed. In K-AlGe-GIS, this flattening occurs almost linear with pressure, whereas it is nonlinear in the GaSi-analogue due to structural changes of the water-cation assembly under hydrostatic pressures.

43 PARTICLE ACCELERATORS↗

Threshold charmonium photoproduction with GlueX

We report the total and differential cross sections for J/ψ photoproduction obtained using the large acceptance GlueX spectrometer at the 12 GeV JLab accelerator over the full near-threshold kinematic region. The GlueX experiment uses tagged linearly-polarized photon beam from coherent Bremsstrahlung off a thin diamond. Charmonium photoproduction near threshold, under certain assumptions including gluon exchange and factorization, can be used to study important aspects of the gluon structure of the proton, such as the gluon GPD, the gravitational form factors, the mass radius of the proton, and the anomalous contribution to the proton mass. In the measured cross sections we find evidence for possible contributions beyond gluon exchange. The results are compared to a wide range of theoretical predictions including GPD calculations and models with open-charm intermediate states. Photoproduction near threshold of charmonium states with opposite-to-photon parity offer another opportunity, complementary to the J/ψ, to understand the reaction mechanism of the charmonium photoproduction. While we see some evidence for such states, comprehensive studies of such higher-mass charmonia can be done only with the proposed JLab energy upgrade. An electron beam energy of up to 22 GeV significantly increases the photon flux and polarization in the corresponding threshold regions allowing for precise cross section and polarization measurements there.

Pentchev, Lubomir↗

Three dimensional unstructured multigrid for the Euler equations

The three dimensional Euler equations are solved on unstructured tetrahedral meshes using a multigrid strategy. The driving algorithm consists of an explicit vertex-based finite element scheme, which employs an edge-based data structure to assemble the residuals. The multigrid approach employs a sequence of independently generated coarse and fine meshes to accelerate the convergence to steady-state of the fine grid solution. Variables, residuals and corrections are passed back and forth between the various grids of the sequence using linear interpolation. The addresses and weights for interpolation are determined in a preprocessing stage using linear interpolation. The addresses and weights for interpolation are determined in a preprocessing stage using an efficient graph traversal algorithm. The preprocessing operation is shown to require a negligible fraction of the CPU time required by the overall solution procedure, while gains in overall solution efficiencies greater than an order of magnitude are demonstrated on meshes containing up to 350,000 vertices. Solutions using globally regenerated fine meshes as well as adaptively refined meshes are given.

Mavriplis, D. J.↗

Three dimensional unstructured multigrid for the Euler equations

The three-dimensional Euler equations are solved on unstructured tetrahedral meshes using a multigrid strategy. The driving algorithm consists of an explicit vertex-based finite-element scheme, which employs an edge-based data-structure to assemble the residuals. The multigrid approach employs a sequence of independently generated coarse and fine meshes to accelerate the convergence to steady-state of the fine grid solution. Variables, residuals and corrections are passed back and forth between the various grids of the sequence using linear interpolation. The addresses and weights for interpolation are determined in a preprocessing stage using an efficient graph traversal algorithm. The preprocessing operation is shown to require a negligible fraction of the CPU time required by the overall solution procedure, while gains in overall solution efficiencies greater than an order of magnitude are demonstrated on meshes containing up to 350,000 vertices. Solutions using globally regenerated fine meshes as well as adaptively refined meshes are given.

Mavriplis, D. J.↗

Mechanism of generating fast electrons by an intense laser at a steep overdense interface

The acceleration and heating of electrons by an intense laser normally incident on a steep overdense plasma interface is investigated using the particle-in-cell code osiris. Energetic electrons are generated by the laser's electric field in the vacuum region within {lambda}/4 of the surface. Only those electrons which originate within the plasma with a sufficiently large transverse momentum can escape the plasma. This mechanism relies on the standing wave structure created by the incoming and reflected wave and is therefore very different for linear and circularly polarized light.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of Photoinjectors

High-brightness electron beam sources play a crucial role in many advanced acceleration schemes as well as linac-based light sources such as Energy Recovery Linac (ERL) based light sources and FELs. Three varieties electron sources (photo, thermionic, and field emission) the photoinjector is especially attractive due to its innate ability to control the time structure of intense electron bunches with low transverse and longitudinal emittance. In all cases, the quality of the bunch begins with the intrinsic emittance and time response of the photocathode, and we discuss the trade-offs involved between the various material choices. A variety of longitudinal laser pulse-shaping techniques are currently being developed to linearize space charge forces or create trains of ultra-short bunches. The emittance compensation technique mitigates the growth of the projected emittance due to the linear space charge force while the bunch is accelerated and compressed in an injector. While the normal conducting rf photoinjector is the workhorse of this field, the dc photoinjector is being pushed to its high-voltage limits, and the year 2010 promises to be a critical year for the superconducting rf photoinjector. Parallel to the development of the hardware, rapid progress has also been made with modeling codes, theory, and bench marking of diagnostics. We attempt to give both a tutorial of photoinjectors and a review of the current state of the art in this rapidly developing field.

43 PARTICLE ACCELERATORS↗

Vibration Model Validation for Linear Collider Detector Platforms

The ILC and CLIC reference designs incorporate reinforced-concrete platforms underneath the detectors so that the two detectors can each be moved onto and off of the beamline in a Push-Pull configuration. These platforms could potentially amplify ground vibrations, which would reduce luminosity. In this paper we compare vibration models to experimental data on reinforced concrete structures, estimate the impact on luminosity, and summarize implications for the design of a reinforced concrete platform for the ILC or CLIC detectors.

43 PARTICLE ACCELERATORS↗

The Injection System of the INFN-SuperB Factory Project: Preliminary Design

The ultra high luminosity B-factory (SuperB) project of INFN requires a high performance and reliable injection system, providing electrons at 4 GeV and positrons at 7 GeV, to fulfil the very tight requirements of the collider. Due to the short beam lifetime, continuous injection of electron and positron bunches in both LER and HER rings is necessary to maintain an high average luminosity. Polarized electrons are required for experiments and must be delivered by the injection system, due to the beam lifetime shorter than the ring polarization build-up: they will be produced by means of a SLAC-SLC polarized gun. The emittance and the energy spread of the e{sup -}/e{sup +} beams are reduced in a 1 GeV Damping Ring (DR) before injection in the main rings. Two schemes for positron production are under study, one with e{sup -}/e{sup +} conversion at low energy (< 1 Gev) and one with conversion at 6 GeV and a recirculation line to bring the positrons back to the DR. Acceleration through the Linac is provided by a 2856 MHz RF system made of travelling wave (TW), room temperature accelerating structures.

43 PARTICLE ACCELERATORS↗

SANE Of Jefferson Lab: Spin Asymmetries on the Nucleon Experiment

The Spin Asymmetry on the Nucleon Experiment (SANE) at Jefferson Lab measures proton spin observables A{sub 1}{sup p}, A{sub 2}{sup p} and structure functions g{sub 1}{sup p} and g{sub 2}{sup p} over a broad range of Bjorken scaling variable x from 0.3 to 0.8, for four-momentum transfers ranging from 2.5 GeV{sup 2} to 6.5 GeV{sup 2}. Inclusive double spin asymmetries were measured by scattering 4.7 and 5.9-GeV longitudinally polarized electron beam off a polarized solid NH{sub 3} target, in both parallel and near-perpendicular configuration. Scattered electrons were detected using a novel non-magnetic detector array with 194-msr acceptance. This paper presents the physics motivation for the experiment, the detector performance, and the latest status of the ongoing data analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

KLYNAC: Compact linear accelerator with integrated power supply

Accelerators and accelerator-based light sources have a wide range of applications in science, engineering technology and medicine. Today the scienti c community is working towards improving the quality of the accelerated beam and its parameters while trying to develop technology for reducing accelerator size. This work describes a design of a compact linear accelerator (linac) prototype, resonant Klynac device, which is a combined linear accelerator and its power supply - klystron. The intended purpose of a Klynac device is to provide a compact and inexpensive alternative to a conventional 1 to 6 MeV accelerator, which typically requires a separate RF source, an accelerator itself and all the associated hardware. Because the Klynac is a single structure, it has the potential to be much less sensitive to temperature variations than a system with separate klystron and linac. We start by introducing a simpli ed theoretical model for a Klynac device. We then demonstrate how a prototype is designed step-by-step using particle-in-cell simulation studies for mono- resonant and bi-resonant structures. Finally, we discuss design options from a stability point of view and required input power as well as behavior of competing modes for the actual built device.

43 PARTICLE ACCELERATORS↗