The stereoisomeric composition of phytanyl chains in lipids of Dead Sea sediments

Lipid extracts from five recent Dead Sea sediments were analyzed for isoprenoid compounds and the following were isolated: free and phospholipid-bound di-O-phytanylglycerol, free phytanol and free and esterified phytanic acid. The phytanyl groups of the diether and the free phytanol were oxidized to the corresponding phytanic acid; the stereoisomeric composition of the derived phytanic acids as well as of the ester-bound phytanic acid was determined by open-tubular gas-liquid chromatography of the corresponding methyl esters on butanediolsuccinate polyester. Only the 3R, 7R, 11R-isomer of phytanic acid was detected in each of the phytanate samples, indicating that these phytanyl chains in the Dead Sea sediments are most likely derived from extremely halophilic bacteria rather than from phytol of chlorophyll origin. These findings also provide further evidence that the mixtures of RRR and SRR-phytanic acids previously isolated from organic-rich shales were most likely derived from the phytyl chain in chlorophyll.

Anderson, R.↗

A Future Mars Environment for Science and Exploration

Today, Mars is arid and cold with a very thin atmosphere that has significant frozen and underground water resources. The thin atmosphere prevents liquid water from residing permanently on its surface and makes it difficult to land missions since it is not thick enough to completely facilitate a soft landing. In its past, under the influence of a significant greenhouse effect, Mars must have had a significant water ocean covering perhaps 30% of the northern hemisphere. Mars lost its protective magnetosphere and therefore much of its atmosphere around 3 Ga ago, due to the solar wind. The atmospheric loss into the solar wind is somewhat balanced by the outgassing of the Mars interior and crust that contributes to the existing atmosphere leading to a global-mean surface atmosphere of ~6 mbar pressure currently. By using our extensive simulation tools and physics capabilities in Space Weather and Mars global climate modeling, we have started to explore the effects on Mars of placing an artificial magnetic dipole field at the Mars L1 Lagrange point putting Mars in a magnetotail. This situation then eliminates many of the solar-wind erosion processes that occur with the planet's ionosphere and upper atmosphere allowing the Martian atmosphere to grow in pressure and bulk temperature over time. Under thicker atmospheres, the global circulation patterns and seasonal changes are much different than at present. An enhanced atmosphere would: allow larger landed mass of equipment to the surface, shield against some cosmic and solar particle radiation, extend the ability for extraction, and provide "open air" greenhouses to exist for plant production, just to name a few. These new conditions on Mars would allow human explorers and researchers to study the planet in much greater detail and enable a truly profound new understanding of the habitability of this planet.

Space Weather and Mars global climate modeling↗

Methods and Devices for Micro-Isolation, Extraction, and/or Analysis of Microscale Components

Provided herein are devices and methods for the micro-isolation of biological cellular material. A micro-isolation apparatus described can comprise a photomask that protects regions of interest against DNA-destroying illumination. The micro-isolation apparatus can further comprise photosensitive material defining access wells following illumination and subsequent developing of the photosensitive material. The micro-isolation apparatus can further comprise a chambered microfluidic device comprising channels providing access to wells defined in photosensitive material. The micro-isolation apparatus can comprise a chambered microfluidic device without access wells defined in photosensitive material where valves control the flow of gases or liquids through the channels of the microfluidic device. Also included are methods for selectively isolating cellular material using the apparatuses described herein, as are methods for biochemical analysis of individual regions of interest of cellular material using the devices described herein. Further included are methods of making masking arrays useful for the methods described herein.

Kartalov, Emil P.↗

Baseline Hypothetical Facility for the Production of 131 I and 99 Mo using Activation Targets

This report describes a hypothetical facility for production of medical radioisotopes via activation under the Proliferation Resistance and Optimization (PRO-X) program. The facility uses neutron activation of non-special nuclear material (SNM) to produce the medical isotopes 131 I and 99 Mo at a throughput of 60 Ci/week of 131 I and 5 Ci/week of 99 Mo. The hypothetical design was carried out using a 10 MWt research reactor. The precursors used for the activation process were TeO2 for 131 I and MoO 3 for 99 Mo. The processes are performed in 3 hot cells used for target receipt, extraction, purification low specific activity (LSA) generator introduction, and packaging. A fourth hotcell is used for waste processing. The hot cell processing area takes up a footprint of 15.4 m 2 with the total footprint of the facility, including space for administrative offices, non-rad labs, quality assurance, and radiation buffer areas set at 763 m 2 . Waste is produced at a weekly rate of 257.8 g low activity solid waste and 8032.7 mL of low activity liquid waste, 8032 mL of which is water. This baseline hypothetical facility for production of medical isotopes via activation was then compared and contrasted to the hypothetical facility for production of medical isotopes via fission products to show the differences in approach for the two production modes. The two production modes had several highlighted differences including the overall facility and hot cell layout, the type and amount of waste produced by the respective facilities, and economic factors impacting production mode. Finally, a decision tree for which production mode might be more beneficial for an entrant into medical isotope production was developed based on the differences examined and the desired output of medical isotopes desired by the entrant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Studies of the trigger performance of the ICARUS T600 detector at Fermilab

In recent years, experimental neutrino anomalies were reported: if confirmed, they could hint at the existence of additional sterile neutrino states participating in the mixing phenomenon. The future Short-Baseline Neutrino (SBN) project at Fermilab will pursue sterile neutrino searches, by exploiting three Liquid Argon (LAr) Time Projection Chamber (TPC) detectors located on-axis along the Booster Neutrino Beam (BNB). Aside from SBND and MicroBooNE, ICARUS will be the far detector and will also be interested by the NuMI beam (off-axis). The trigger system is a key component of the detector: it is based on the coincidence of prompt signals from scintillation light in the LAr-TPC (recorded by a system of PhotoMultiplier Tubes, PMTs) with the proton spill extraction of the beam. The present system exploits a majority-based logic and may be complemented by a trigger system based on adder boards, that add the analog signals of the PMTs in groups of 15. Triggering on the sum may help in identifying events closer to the TPC walls, in which there is plenty of light collected by few PMTs and for which the majority condition may not be satisfied. Many tests were carried out to characterize the adder boards, both on the hardware and software sides.

43 PARTICLE ACCELERATORS↗

Microwave Polarized Signatures Generated within Cloud Systems: SSM/I Observations Interpreted with Radiative Transfer Simulations

Special Sensor Microwave /Imager (SSM/I) observations in cloud systems are studied over the tropics. Over optically thick cloud systems, presence of polarized signatures at 37 and 85 GHz is evidenced and analyzed with the help of cloud top temperature and optical thickness extracted from visible and IR satellite observations. Scattering signatures at 85 GHz (TbV(85) less than or = 250 K) are associated with polarization differences greater than or = 6 K, approx. 50%, of the time over ocean and approx. 40% over land. In addition. over thick clouds the polarization difference at 37 GHz is rarely negligible. The polarization differences at 37 and 85 GHz do not stem from the surface but are generated in regions of relatively homogeneous clouds having high liquid water content. To interpret the observations, a radiative transfer model that includes the scattering by non-spherical particles is developed. based on the T-matrix approach and using the doubling and adding method. In addition to handling randomly and perfectly oriented particles, this model can also simulate the effect of partial orientation of the hydrometeors. Microwave brightness temperatures are simulated at SSM/I frequencies and are compared with the observations. Polarization differences of approx. 2 K can be simulated at 37 GHz over a rain layer, even using spherical drops. The polarization difference is larger for oriented non-spherical particles. The 85 GHz simulations are very sensitive to the ice phase of the cloud. Simulations with spherical particles or with randomly oriented non-spherical ice particles cannot replicate the observed polarization differences. However, with partially oriented non-spherical particles, the observed polarized signatures at 85 GHz are explained, and the sensitivity of the scattering characteristics to the particle size, asphericity, and orientation is analyzed. Implications on rain and ice retrievals are discussed.

Prigent, Catherine↗

Detecting Organic Compounds Released from Iron Oxidizing Bacteria using Sample Analysis at Mars (SAM) Like Instrument Protocols

Mars is a planet of great interest for Astrobiology since its past environmental conditions are thought to have been favourable for the emergence life. At present, the Red Planet is extremely cold and dry and the surface is exposed to intense UV and ionizing radiation, conditions generally considered to be incompatible with life as we know it on Earth. It was proposed that the shallow subsurface of Mars, where temperatures can be above freezing and liquid water can exist on rock surfaces, could harbor chemolithoautotrophic bacteria such as the iron oxidizing microorganism Pseudomonas sp. HerB. The Mars Science Laboratory (MSL) mission will provide the next opportunity to carry out in situ measurements for organic compounds of possible biological origin on Mars. One instrument onboard MSL, called the Sample Analysis at Mars (SAM) instrument suite, will carry out a broad and sensitive search for organic compounds in surface samples using either high temperature pyrolysis or chemical extraction followed by gas chromatography mass spectrometry. We present gas chromatograph mass spectrometer (GC/MS) data on crushed olivine rock powders that have been inoculated with Pseudomonas sp. HerB at different concentrations ranging from approx 10(exp 2) to 10(exp 7) cells per gram. The inoculated olivine samples were heated under helium carrier gas flow at 500 C and the pyrolysis products concentrated using a SAM-like hydrocarbon trap set at -20 C followed by trap heating and analysis by GC/Ms. In addition, the samples were also extracted using a low temperature "one-pot" chemical extraction technique using N-methyl, N-(tert-butyldimethylsilyl) trifluoroacetamide (MTBSTFA) as the silylating agent prior to GC/MS analysis. We identified several aldehydes, thiols, and alkene nitriles after pyrolysis GC/MS analysis of the bacteria that were not found in the olivine control samples that had not been inoculated with bacteria. The distribution of pyrolysis products extracted from the bacteria was clearly distinct from similar GC/MS analyses of the carbonaceous meteorite Murchison that was dominated by sulfur containing aromatic compounds. A similar comparison, if organic compounds are detected by SAM on Mars, could be useful to help discriminate between meteoritic or biological origins.

Glavin, D. P.↗

Chemical Kinetics of the TPS and Base Bleeding During Flight Test

The present research deals with thermal degradation of polyurethane foam (PUF) during flight test. Model of thermal decomposition was developed that accounts for polyurethane kinetics parameters extracted from thermogravimetric analyses and radial heat losses to the surrounding environment. The model predicts mass loss of foam, the temperature and kinetic of release of the exhaust gases and char as function of heat and radiation loads. When PUF is heated, urethane bond break into polyol and isocyanate. In the first stage, isocyanate pyrolyses and oxidizes. As a result, the thermo-char and oil droplets (yellow smoke) are released. In the second decomposition stage, pyrolysis and oxidization of liquid polyol occur. Next, the kinetics of chemical compound release and the information about the reactions occurring in the base area are coupled to the CFD simulations of the base flow in a single first stage motor vertically stacked vehicle configuration. The CFD simulations are performed to estimate the contribution of the hot out-gassing, chemical reactions, and char oxidation to the temperature rise of the base flow. The results of simulations are compared with the flight test data.

Osipov, Viatcheslav↗

Validation of Thermodynamic Vent System Performance using Thermal Desktop

Cryogenic fluid management (CFM) for in-space propulsion systems is crucial to enabling future space missions. A means to control the pressure inside a propellant tank is necessary to prevent the venting of liquid propellant in microgravity environments. A thermodynamic vent system (TVS) is one way to regulate the pressure and temperature of the fluid inside a tank. A previous study created a simplified model of a TVS in a two-phase cryogenic heat exchanger. The TVS expands the working fluid across a Joule-Thomson (J-T) device and routes the cooled fluid through the heat exchanger to remove heat from the surrounding fluid. The model was able to predict the TVS heat extraction performance and was validated against experimental data using the same hardware. This study expands the model of the TVS into Thermal Desktop (TD) and recreates the results from both the original model and the experimental data. This new TD model has the potential to be used to predict TVS heat extraction performance in cryogenic propellant tanks for future space missions.

Cryogenic Fluid Management↗

An Improved Hf Vapor Etching Apparatus for Stardust Particle Extraction

Introduction: The NASA Stardust mission captured thousands of particles from the Jupiter-family comet 81P/Wild 2 in a collector composed of aluminum foil and blocks of silica aerogel [1]. To date, most Wild 2 particles available for study are relatively large and coherent particles extracted individually from the ends of hollow, carrot-shaped impact tracks produced during impact into aerogel. However, >65% of the impacting mass can be found in the ‘bulb’ of the track, including nearly all of the <1 μm size fraction [2]. This fraction contains organic-rich material and is likely to include presolar grains, representing a critical opportunity to constrain the organic and presolar inventory of primitive outer solar system materials. However, the small size and susceptibility of this fraction to melting or alteration during capture poses significant analytical challenges. Previous attempts to extract and concentrate fine-grained material from the bulb of Stardust tracks have attempted to develop techniques that efficiently destroy aerogel and leave impactor particles relatively unharmed. The low density and high porosity of silica aerogel makes it more susceptible to attack by etching with hydrofluoric acid (HF) [3] or CF4 plasma ashing [4] than collected cometary silicates. Previous studies of HF vapor etching used HF solutions varying between 5 to 49% and noted that at high concentrations and etch rates, a liquid droplet was produced according to the etching reaction 4HF + SiO2 → SiF4 (g) + 2H2O [3]. SiF4 readily decomposes into HF and silicic acid in water, which has the potential to alter the freed cometary silicates. The plasma ashing technique avoids production of a liquid droplet and minimizes damage to embedded silicates but requires specialized equipment [4]. In this abstract, we present recent improvements to the HF etching procedure with the aim of constructing an etching chamber capable of slowly etching silica aerogel using small quantities of dilute HF. The etching chamber can be assembled using readily available materials.

Stardust↗

Analysis strategy for ultrafast X-ray photon correlation spectroscopy

We explain an analysis strategy for ultrafast X-ray photon correlation spectroscopy, a technique enabled by X-ray free electron lasers to probe nano- and atomic-scale dynamics in complex systems on nanosecond timescales or faster. Central to the technique is the methodology for extracting contrast in coherent X-ray diffraction patterns, known as speckle patterns. Guided by simulations, we analyze common challenges and examine errors encountered in contrast extraction. A method for accurately determining contrast amid shot noise across a wide range of count rates is presented.

36 MATERIALS SCIENCE↗

Insights From Routine Microbiological Monitoring of Air in Astromaterials Curation Cleanrooms

NASA maintains nine separate cleanrooms at the Johnson Space Center to curate and preserve astromaterials samples. Routine microbial monitoring of the surfaces in these cleanrooms began in 20181. Until recently, materials compatibility requirements prevented monitoring airborne biological particles in all but one of these cleanrooms. New astromaterials collections from carbon rich asteroids are more susceptible to biological degradation than previous collections. Therefore, it is important to monitor the bioburden in the air and on surfaces in these labs. Establishing a comprehensive microbial monitoring program will help inform the monitoring and curation plans for Mars sample return which will include samples that are extremely biologically sensitive. In April of 2022 we began routinely collecting air samples in seven of the nine curation cleanrooms (Meteorite ISO 7 equivalent, Lunar ISO 6 equivalent, Stardust, Hayabusa2, OSIRIS-REx ISO 5 equivalent, and Genesis ISO 4 equivalent) using a sampling device that collects airborne biological particles on an electret filter instead conventional sampler that collect cells in a liquid media or onto organic rich Petri dishes. Electret is a generic term for electrostatically charged media. The charge on these materials increases particle trapping when compared to non-charged filters of similar thickness. N95 respirators also use electret filters. This dry sample collection method allows us to meet materials requirements for all the curation labs and reduces the risk of inadvertently introducing contamination as part of our monitoring effort. This method also allows us to preserve a portion of each sample for DNA extraction and next generation sequencing. DNA sequencing helps us to characterize the portion of the cleanroom microbiome that we cannot culture. We will present the results of our first 8 months of monitoring, compare these results to particle counts in the labs and to measurements made directly onto Petri dishes when possible. We will also make recommendations for modifications to the sampling method to improve sampling efficiency and preserve diversity.

A. B. Regberg↗

Zero Gravity Cryogenic Vent System Concepts for Upper Stages

The capability to vent in zero gravity without resettling is a technology need that involves practically all uses of sub-critical cryogenics in space. Venting without resettling would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule-Thomson (J-T) valve to extract thermal energy from the propellant. Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (MHTB) was used to test both spray bar and axial jet TVS concepts. The axial jet system consists of a recirculation pump heat exchanger unit. The spray bar system consists of a recirculation pump, a parallel flow concentric tube, heat exchanger, and a spray bar positioned close to the longitudinal axis of the tank. The operation of both concepts is similar. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it into the tank liquid, ullage, and exposed tank surfaces. When energy is required. a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the heat exchanger, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point. the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating, boil-off losses.

Flachbart, Robin H.↗

Thermal Field Imaging Using Ultrasound

It is often desirable to be able to determine the temperature field in the interiors of opaque fluids forced into convection by externally imposed temperature gradients. To measure the temperature at a point in an opaque fluid in the usual fashion requires insertion of a probe, and to determine the full field therefore requires either the ability to move this probe or the introduction of multiple probes. Neither of these solutions is particularly satisfactory, although they can lead to quite accurate measurements. As an alternative we have investigated the use of ultrasound as a relatively non-intrusive probe of the temperature field in convecting opaque fluids. The temperature dependence of the sound velocity can be sufficiently great to permit a determination of the temperature from timing the traversal of an ultrasound pulse across a chamber. In this paper we will present our results on convecting flows of transparent and opaque fluids. Our experimental cells consist of relatively narrow rectangular cavities made of thermally insulating materials on the sides, and metal top and bottom plates. The ultrasound transducer is powered by a pulser/receiver, the signal output of which goes to a very high speed signal averager. The average of several hundred to several thousand signals is then sent to a computer for storage and analysis. The experimental procedure is to establish a convective flow by imposing a vertical temperature gradient on the chamber, and then to measure, at several regularly spaced locations, the transit time for an ultrasound pulse to traverse the chamber horizontally (parallel to the convecting rolls) and return to the transducer. The transit time is related to the temperature of the fluid through which the sound pulse travels. Knowing the relationship between transit time and temperature (determined in a separate experiment), we can extract the average temperature across the chamber at that location. By changing the location of the transducer it is then possible to find the average temperature at different locations along the chamber, thereby determining the temperature profile along the system. (In the future we will construct an array of transducers. This will give us the capability to determine the temperature profile much more rapidly than at present, an important consideration if time-dependent phenomena are to be studied.) To validate our procedure we introduced encapsulated liquid crystal particles into glycerol. The liquid crystal particles' color varies depending on the temperature of the fluid. A photograph of the fluid through transparent sidewalls therefore gives a picture of the temperature field of the convecting fluid, independent of our ultrasound imaging. A representative result is shown in the Figure 1, which reveals a very satisfying correspondence between the two techniques. Therefore we have a great deal of confidence that the ultrasound imaging approach is indeed measuring the actual temperature profile of the fluid. The technique has also been applied to convecting liquid metal flows, and representative data will be presented from those experiments as well.

Andereck, D.↗

Automated Fluidics Device for Extraction and Quantification of miRNA Biomarkers From Blood

Radiation Assessment DuRing Exposure And long-Duration Spaceflight (RADREADS) demonstrates space-compatible point-of-care technology for quantitative biological monitoring of blood miRNA biomarkers in response to long-term low dose radiation exposure. This individualized monitoring approach will inform targeted treatment strategies to maximize medical resource utilization by accounting for individual susceptibility to radiation-related illnesses. As human spaceflight progresses beyond Earth’s magnetic shielding, radiation exposure poses a significant risk to astronaut health and safety. Extended operation in this environment comes with an increased risk of radiation exposure, leading to higher risks of radiation sickness, cancer, central nervous system effects, and degenerative diseases. While conventional physical dosimetry techniques capture radiation dose, individualistic susceptibility to radiation damage is varied. Multiple characteristics, including age, body weight, sex, genetics, and immune status, have been found to influence radiosensitivity (Liu et al. 2011, and Bouffler 2016). This differential response necessitates individualized monitoring and targeted treatment strategies to maximize medical resource utilization; however, a practical diagnostic platform for quantifying long-term, low dose radiation-induced tissue damage does not currently exist. MicroRNAs (miRNAs) are a class of small, non-coding RNAs that regulate gene expression by mediating the degradation of messenger RNA. The levels of particular miRNAs are influenced by biological processes such as inflammation and serve as biomarkers for a variety of conditions including cancer (Singh et al. 2017). MicroRNAs are found in various bodily fluids and are amenable to collection via liquid biopsies, providing a minimally invasive and easily quantifiable readout for a variety of radiosensitive reporters. A preliminary signature of 15 spaceflight sensitive miRNA has been identified in rodent and human studies, including miR-21-5p, miR-24-3p, miR-92a-3p, miR-17-5p, miR-16a-3p, miR-34a-3p, and miR-223-3p. These targets generally increased expression with radiation dose and linear energy transfer, though variation between individuals is not yet described. Current gaps in the field include a lack of understanding of longitudinal biological responses to long-term, low dose radiation exposure and the absence of space-compatible point-of-care technology for quantitative biological monitoring. In this body of work, we aim to develop an automated bleed-to-read system to process whole blood for the detection of miRNA biomarkers in order to monitor individualistic responses to radiation exposure. This will be achieved via separating serum (or plasma) from whole blood, followed by extraction, amplification, and quantification of the miRNA using a RT-qPCR reaction. Previously, the WetLab-2 hardware enabled execution of a RT-qPCR reaction aboard ISS; however, it is a manual system that requires crew manipulation and bulky components (Parra et al. 2017). To address these issues, automated fluid handling hardware was developed for each stage of sample preparation. Extraction of total RNA is achieved by sequentially pumping reagents through an off-the-shelf nucleic acid binding column (miRNeasy Serum/Plasma Advanced Kit, Qiagen). This approach eliminates several manual pipetting and centrifuging steps and limits the use of toxic chemicals commonly found in other sample processing techniques. The resulting elution will then be automatically dispensed for RT-qPCR analysis using a compact rotary qPCR (Mic qPCR Cycler, Bio Molecular Systems) that will improve spaceflight compatibility by removing bubbles from the detection region, another challenge highlighted by WetLab-2 (Parra et al. 2017). Efforts are also being made to simplify the RT-qPCR reaction to a 1-step air-dryable mix to improve long-term reagent stability at room temperature and reduce system complexity. By automating the RT-qPCR processes via microfluidic manipulation, RADREADS will reduce crewmember hands-on time and enable the personalized detection of radiation-induced tissue damage during long duration missions. Minimally invasive, longitudinal monitoring of individual’s response to radiation exposure will inform how the physiological system responds to long-term low dose space radiation and enables development of targeted countermeasures by the medical team. Ultimately, this portable technology will require minimal technical expertise and can also be used to monitor miRNA biomarkers associated with other diseases.

Tristen Head↗

First Detection of Non-Chlorinated Organic Molecules Indigenous to a Martian Sample

The Sample Analysis at Mars (SAM) instrument onboard Curiosity can perform pyrolysis of martian solid samples, and analyze the volatiles by direct mass spectrometry in evolved gas analysis (EGA) mode, or separate the components in the GCMS mode (coupling the gas chromatograph and the mass spectrometer instruments). In addition, SAM has a wet chemistry laboratory designed for the extraction and identification of complex and refractory organic molecules in the solid samples. The chemical derivatization agent used, N-methyl-N-tert-butyldimethylsilyl- trifluoroacetamide (MTBSTFA), was sealed inside seven Inconel metal cups present in SAM. Although none of these foil-capped derivatization cups have been punctured on Mars for a full wet chemistry experiment, an MTBSTFA leak was detected and the resultant MTBSTFA vapor inside the instrument has been used for a multi-sol MTBSTFA derivatization (MD) procedure instead of direct exposure to MTBSTFA liquid by dropping a solid sample directly into a punctured wet chemistry cup. Pyr-EGA, Pyr-GCMS and Der-GCMS experiments each led to the detection and identification of a variety of organic molecules in diverse formations of Gale Crater.

Freissinet, C.↗

Assessing Structural, Thermal, and Functional Characteristics of Marigold Flower Protein as a Sustainable Food Ingredient

The demand for sustainable and alternative protein sources has been on the rise, driving interest in the valorization of underutilized plants. This study evaluated Calendula officinalis (marigold), a common floral waste, as a sustainable alternative protein source for the food industry. The primary objective of this study was to investigate the physicochemical properties of protein fractions from Calendula officinalis flower to evaluate their potential as a novel protein ingredient. Extraction of the Calendula officinalis flower yielded 92.17% of the crude protein. A sequential extraction of albumin, globulin, glutelin, and prolamin from marigold flower revealed albumin as the dominant fraction (65.47%) and exhibited the highest protein functionality, including water-holding capacity (2.37 g/g), oil-holding capacity (2.49 g/g), and emulsifying capacity (65.22 mL/g). Compared with other protein fractions, glutelin showed a relatively high emulsifying and foaming capacity (EC: 59.13 mL/g; FC: 16.23%). Differential scanning calorimetry revealed high thermal stability for albumin (T p = 105.28 °C) and glutelin (T p = 97.6 °C). Sodium Dodecyl Sulfate–Polyacrylamide Gel Electrophoresis (SDS-PAGE) and Liquid Chromatography–Mass Spectrometry (LC-MS) confirmed the presence of abundant low-molecular-weight polypeptides (<37 kDa), which enhanced emulsification, while scanning electron microscopy revealed porous structures aligned with hydration properties. Antioxidant activity was higher in albumin and glutelin, linked to surface hydrophobicity. LC-MS/MS identified 33 short-chain proteins, including oxidoreductase proteins and lipid-transfer proteins. Findings highlight marigold flower proteins as a sustainable, functional ingredient for a diverse range of food applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Capturing thin structures in VOF simulations with two-plane reconstruction

A novel interface reconstruction strategy for volume of fluid (VOF) methods is introduced that represents the liquid-gas interface as two planes that co-exist within a single computational cell. In comparison to the piecewise linear interface calculation (PLIC), this new algorithm greatly improves the accuracy of the reconstruction, in particular when dealing with thin structures such as films. The placement of the two planes requires the solution of a non-linear optimization problem in six dimensions, which has the potential to be overly expensive. Further, an efficient solution to this optimization problem is presented here that exploits two key ideas: an algorithm for extracting multiple plane orientations from transported surface data, and an efficient and mass-conserving distance-finding algorithm that accounts for two planes with arbitrary orientation. Additionally, a simple and robust strategy is presented to accurately represent the surface tension forces produced at the interface of subgrid-thickness films. The performance of this new VOF reconstruction is demonstrated on several test cases that illustrate the capability to handle arbitrarily thin films.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗