Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Evaluation of Angiographic and Technical Aspects of Carotid Stenting with Diffusion-Weighted Magnetic Resonance Imaging

The detection of clinically silent ischemic lesions on postprocedural diffusion-weighted magnetic resonance images has become a preferred method for the description of embolic risks. The purpose of this single-center study was to evaluate whether diffusion-weighted imaging (DWI) could determine material related or technical risk factors of filter-protected carotid stenting. Eighty-four patients with symptomatic severe ({>=}60%) carotid artery stenoses received filter-protected carotid stenting. Standard DWI (b = 1000) was performed within 48 h before and after carotid stenting. The occurrence and load of new postinterventional DWI lesions were assessed. Multivariate analysis was performed to determine risk factors associated with DWI lesions, with emphasis on technical factors such as use of different access devices (guiding catheter method vs. long carotid sheath method), type of stent (open-cell nitinol stent vs. closed-cell Wallstent), and protective device (filters with 80-{mu}m vs. 110-120-{mu}m pore size). Markers for generalized atherosclerosis and for degree and site of stenosis were assessed to allow comparison of adequate risk profiles. Access, protective device, and stent type were not significantly associated with new embolic DWI lesions when we compared patients with equivalent risk profiles (long carotid sheath method 48% [11 of 23] vs. guiding catheter method 44% [27 of 61], Wallstent 47% [15 of 32] vs. nitinol stent 44% [23 of 52], and small pore size filter 61% [11 of 18] vs. large pore size filter 41% [27 of 66]). Single-center DWI studies with a moderate number of cases are inadequate for proper assessment of the embolic risk of technical- or material-related risk factors in carotid stenting. Larger multicenter studies with more cases are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Esophageal Tumor Motion on Cine-Magnetic Resonance Imaging

Purpose: To quantify the movement of esophageal tumors noninvasively on cine-magnetic resonance imaging (MRI) by use of a semiautomatic method to visualize tumor movement directly throughout multiple breathing cycles. Methods and Materials: Thirty-six patients with esophageal tumors underwent MRI. Tumors were located in the upper (8), middle (7), and lower (21) esophagus. Cine-MR images were collected in the coronal and sagittal plane during 60 seconds at a rate of 2 Hz. An adaptive correlation filter was used to automatically track a previously marked reference point. Tumor movement was measured in the craniocaudal (CC), left–right (LR), and anteroposterior (AP) directions and its relationship along the longitudinal axis of the esophagus was investigated. Results: Tumor registration within the individual images was typically done at a millisecond time scale. The mean (SD) peak-to-peak displacements in the CC, AP, and LR directions were 13.3 (5.2) mm, 4.9 (2.5) mm, and 2.7 (1.2) mm, respectively. The bandwidth to cover 95% of excursions from the mean position (c95) was also calculated to exclude outliers caused by sporadic movements. The mean (SD) c95 values were 10.1 (3.8) mm, 3.7 (1.9) mm, and 2.0 (0.9) mm in the CC, AP, and LR dimensions. The end-exhale phase provided a stable position in the respiratory cycle, compared with more variety in the end-inhale phase. Furthermore, lower tumors showed more movement than did higher tumors in the CC and AP directions. Conclusions: Intrafraction tumor movement was highly variable between patients. Tumor position proved the most stable during the respiratory cycle in the end-exhale phase. A better understanding of tumor motion makes it possible to individualize radiation delivery strategies accordingly. Cine-MRI is a successful noninvasive modality to analyze motion for this purpose in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil

We present high-resolution magnetic resonance imaging (MRI) at ultra-low field (ULF) with a proton Larmor frequency of around 120 kHz. The key element is a specially designed high-sensitivity sensing coil in the shape of a solenoid with a few millimeter gap between windings to decrease the proximity effect and, hence, increase the coil’s quality ([Formula: see text]) factor and sensitivity. External noise is strongly suppressed by enclosing the sensing coil in a copper cylindrical shield, large enough not to negatively affect the coil’s [Formula: see text] factor and sensitivity, measured to be 217 and 0.47 fT/Hz[Formula: see text], respectively. To enhance small polarization of proton spins at ULF, a strong pulsed 0.1 T prepolarization field is applied, making the signal-to-noise ratio (SNR) of ULF MRI sufficient for high-quality imaging in a short time. We demonstrate ULF MRI of a copper sulfate solution phantom with a resolution of [Formula: see text] and SNR of 10. The acquisition time is 6.3 min without averaging. The sensing coil size in the current realization can accommodate imaging objects of 9 cm in size, sufficient for hand, and it can be further increased for human head imaging in the future. Since the in-plane resolution of [Formula: see text] is typical in anatomical medical imaging, this ULF MRI method can be an alternative low-cost, rapid, portable method for anatomical medical imaging of the human body or animals. This ULF MRI method can supplement other MRI methods, especially when such methods are restricted due to high cost, portability requirement, imaging artifacts, and other factors.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-I-60: Quality Assurance Testing Methods and Customized Phantom for Magnetic Resonance Imaging and Spectroscopy

Purpose: The objectives of this study are to develop an magnetic resonance imaging and spectroscopy (MRI-MRS) fused phantom along with the inserts for metabolite quantification and to conduct quantitative analysis and evaluation of the layered vials of brain-mimicking solution for quality assurance (QA) performance, according to the localization sequence. Methods: The outer cylindrical phantom body is made of acrylic materials. The section other than where the inner vials are located was filled with copper sulfate and diluted with water so as to reduce the T1 relaxation time. Sodium chloride was included to provide conductivity similar to the human body. All measurements of MRI and MRS were made using a 3.0 T scanner (Achiva Tx 3.0 T; Philips Medical Systems, Netherlands). The MRI scan parameters were as follows: (1) spin echo (SE) T1-weighted image: repetition time (TR), 500ms; echo time (TE), 20ms; matrix, 256×256; field of view (FOV), 250mm; gap, 1mm; number of signal averages (NSA), 1; (2) SE T2-weighted image: TR, 2,500 ms; TE, 80 ms; matrix, 256×256; FOV, 250mm; gap, 1mm; NSA, 1; 23 slice images were obtained with slice thickness of 5mm. The water signal of each volume of interest was suppressed by variable pulse power and optimized relaxation delays (VAPOR) applied before the scan. By applying a point-resolved spectroscopy sequence, the MRS scan parameters were as follows: voxel size, 0.8×0.8×0.8 cm{sup 3}; TR, 2,000ms; TE, 35ms; NSA, 128. Results: Using the fused phantom, the results of measuring MRI factors were: geometric distortion, <2% and ±2 mm; image intensity uniformity, 83.09±1.33%; percent-signal ghosting, 0.025±0.004; low-contrast object detectability, 27.85±0.80. In addition, the signal-to-noise ratio of N-acetyl-aspartate was consistently high (42.00±5.66). Conclusion: The MRI-MRS QA factors obtained simultaneously using the phantom can facilitate evaluation of both images and spectra, and provide guidelines for obtaining MRI and MRS QA factors simultaneously. This study was supported by grant (2012-007883 and 2014R1A2A1A10050270) from the Mid-career Researcher Program through the NRF funded by Ministry of Science. In addition, this study was supported by the Industrial R&D of MOTIE/KEIT (10048997, Development of the core technology for integrated therapy devices based on real-time MRI-guided tumor tracking)

60 APPLIED LIFE SCIENCES↗

Anatomical pulmonary magnetic resonance imaging segmentation for regional structure-function measurements of asthma

Purpose: Pulmonary magnetic-resonance-imaging (MRI) and x-ray computed-tomography have provided strong evidence of spatially and temporally persistent lung structure-function abnormalities in asthmatics. This has generated a shift in their understanding of lung disease and supports the use of imaging biomarkers as intermediate endpoints of asthma severity and control. In particular, pulmonary {sup 1}H MRI can be used to provide quantitative lung structure-function measurements longitudinally and in response to treatment. However, to translate such biomarkers of asthma, robust methods are required to segment the lung from pulmonary {sup 1}H MRI. Therefore, their objective was to develop a pulmonary {sup 1}H MRI segmentation algorithm to provide regional measurements with the precision and speed required to support clinical studies. Methods: The authors developed a method to segment the left and right lung from {sup 1}H MRI acquired in 20 asthmatics including five well-controlled and 15 severe poorly controlled participants who provided written informed consent to a study protocol approved by Health Canada. Same-day spirometry and plethysmography measurements of lung function and volume were acquired as well as {sup 1}H MRI using a whole-body radiofrequency coil and fast spoiled gradient-recalled echo sequence at a fixed lung volume (functional residual capacity + 1 l). We incorporated the left-to-right lung volume proportion prior based on the Potts model and derived a volume-proportion preserved Potts model, which was approximated through convex relaxation and further represented by a dual volume-proportion preserved max-flow model. The max-flow model led to a linear problem with convex and linear equality constraints that implicitly encoded the proportion prior. To implement the algorithm, {sup 1}H MRI was resampled into ∼3 × 3 × 3 mm{sup 3} isotropic voxel space. Two observers placed seeds on each lung and on the background of 20 pulmonary {sup 1}H MR images in a randomized dataset, on five occasions, five consecutive days in a row. Segmentation accuracy was evaluated using the Dice-similarity-coefficient (DSC) of the segmented thoracic cavity with comparison to five-rounds of manual segmentation by an expert observer. The authors also evaluated the root-mean-squared-error (RMSE) of the Euclidean distance between lung surfaces, the absolute, and percent volume error. Reproducibility was measured using the coefficient of variation (CoV) and intraclass correlation coefficient (ICC) for two observers who repeated segmentation measurements five-times. Results: For five well-controlled asthmatics, forced expiratory volume in 1 s (FEV{sub 1})/forced vital capacity (FVC) was 83% ± 7% and FEV{sub 1} was 86 ± 9%{sub pred}. For 15 severe, poorly controlled asthmatics, FEV{sub 1}/FV C = 66% ± 17% and FEV{sub 1} = 72 ± 27%{sub pred}. The DSC for algorithm and manual segmentation was 91% ± 3%, 92% ± 2% and 91% ± 2% for the left, right, and whole lung, respectively. RMSE was 4.0 ± 1.0 mm for each of the left, right, and whole lung. The absolute (percent) volume errors were 0.1 l (∼6%) for each of right and left lung and ∼0.2 l (∼6%) for whole lung. Intra- and inter-CoV (ICC) were <0.5% (>0.91%) for DSC and <4.5% (>0.93%) for RMSE. While segmentation required 10 s including ∼6 s for user interaction, the smallest detectable difference was 0.24 l for algorithm measurements which was similar to manual measurements. Conclusions: This lung segmentation approach provided the necessary and sufficient precision and accuracy required for research and clinical studies.

60 APPLIED LIFE SCIENCES↗

Molecular Structure Laboratory. Fourier Transform Nuclear Magnetic Resonance (FTNMR) Spectrometer and Ancillary Instrumentation at SUNY Geneseo

An Agilent 400-MR nuclear magnetic resonance (NMR) spectrometer and ancillary equipment were purchased, which are being used for molecular structure elucidation. The instrumentation is housed in a pre-existing facility designed specifically for its use. This instrument package is being used to expand the research and educational efforts of the faculty and students at SUNY-Geneseo and is made available to neighboring educational institutions and business concerns. Funds were also used for training of College personnel, maintenance of the instrumentation, and installation of the equipment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A potential nuclear magnetic resonance imaging approach for noncontact temperature measurement

It is proposed that in a nuclear magnetic resonance (NMR) imaging experiment that it should be possible to measure temperature through an extended volume. The basis for such a measurement would depend upon sensing a temperature dependent on NMR parameter in an inert, volatile molecule (or fluid) filling the volume of interest. Exploratory work suggest that one suitable candidate for such a purpose might be CH3Cl. Possible parameters, other inert gases and feasible measurement schemes that might provide such temperature measurement are discussed.

Manatt, Stanley L.↗

A feasibility study of hand kinematics for EVA analysis using magnetic resonance imaging

A new method of analyzing the kinematics of joint motion is developed. Magnetic Resonance Imaging (MRI) offers several distinct advantages. Past methods of studying anatomic joint motion have usually centered on four approaches. These methods are x-ray projection, goniometric linkage analysis, sonic digitization, and landmark measurement of photogrammetry. Of these four, only x-ray is applicable for in vivo studies. The remaining three methods utilize other types of projections of inter-joint measurements, which can cause various types of error. MRI offers accuracy in measurement due to its tomographic nature (as opposed to projection) without the problems associated with x-ray dosage. Once the data acquisition of MR images was complete, the images were processed using a 3D volume rendering workstation. The metacarpalphalangeal (MCP) joint of the left index finger was selected and reconstructed into a three-dimensional graphic display. From the reconstructed volumetric images, measurements of the angles of movement of the applicable bones were obtained and processed by analyzing the screw motion of the MCP joint. Landmark positions were chosen at distinctive locations of the joint at fixed image threshold intensity levels to ensure repeatability. The primarily two dimensional planar motion of this joint was then studied using a method of constructing coordinate systems using three (or more) points. A transformation matrix based on a world coordinate system described the location and orientation of a local target coordinate system. Future research involving volume rendering of MRI data focusing on the internal kinematics of the hand's individual ligaments, cartilage, tendons, etc. will follow. Its findings will show the applicability of MRI to joint kinematics for gaining further knowledge of the hand-glove (power assisted) design for extravehicular activity (EVA).

Dickenson, Rueben D.↗

Detecting rare earth elements via optically detected magnetic resonance (ODMR) and spin-relaxometry using nitrogen vacancy centers in nanodiamonds

Nanodiamonds embedded with nitrogen-vacancy (NV) centers are emerging as powerful tools in quantum sensing due to their remarkable sensitivity to local variations in electromagnetic fields, temperature, and pressure. These point defects in the diamond lattice can be probed using optically detected magnetic resonance (ODMR) and spin relaxometry techniques, allowing for the detection and characterization of magnetic nanoparticles and ions. The sensing mechanism relies on laser-induced excitation of the NV center's non-degenerate triplet ground state, which promotes electrons to an excited state. Subsequent photoluminescence (PL) emission, which is spin-state dependent, is then measured. These spin states are highly responsive to magnetic perturbations in the surrounding environment. By analyzing changes in the ODMR spectra and spin relaxation times, we can effectively monitor how magnetic species influence the NV center's spin dynamics, thus enabling sensitive and selective characterization of nanoscale magnetic materials. These techniques have been applied for the characterization of transition metals and rare earth elements which shows natural ferromagnetic properties.

magnetic nanopartgicles and ions↗

In Situ Effective Diffusion Coefficient Profiles in Live Biofilms Using Pulsed-Field Gradient Nuclear Magnetic Resonance

Diffusive mass transfer in biofilms is characterized by the effective diffusion coefficient. It is well-documented that the effective diffusion coefficient can vary by location in a biofilm. The current literature is dominated by effective diffusion coefficient measurements for distinct cell clusters and stratified biofilms showing this spatial variation. Regardless of whether distinct cell clusters or surface-averaging methods are used, position-dependent measurements of the effective diffusion coefficient are currently: 1) invasive to the biofilm, 2) performed under unnatural conditions, 3) lethal to cells, and/or 4) spatially restricted to only certain regions of the biofilm. Invasive measurements can lead to inaccurate results and prohibit further (time dependent) measurements which are important for the mathematical modeling of biofilms. In this study our goals were to: 1) measure the effective diffusion coefficient for water in live biofilms, 2) monitor how the effective diffusion coefficient changes over time under growth conditions, and 3) correlate the effective diffusion coefficient with depth in the biofilm. We measured in situ two-dimensional effective diffusion coefficient maps within Shewanella oneidensis MR-1biofilms using pulsed-field gradient nuclear magnetic resonance methods, and used them to calculate surface-averaged relative effective diffusion coefficient (Drs) profiles. We found that 1) Drs decreased from the top of the biofilm to the bottom, 2) Drs profiles differed for biofilms of different ages, 3) Drs profiles changed over time and generally decreased with time, 4) all the biofilms showed very similar Drs profiles near the top of the biofilm, and 5) the Drs profile near the bottom of the biofilm was different for each biofilm. Practically, our results demonstrate that advanced biofilm models should use a variable effective diffusivity which changes with time and location in the biofilm.

59 BASIC BIOLOGICAL SCIENCES↗

Small resonant magnetic perturbations result in three-dimensional material transport in the fusion plasma edge

Erosion patterns in a 3D magnetic topology are significantly altered when compared to an axisymmetric scenario due to differences in the impurity transport in a plasma environment. When resonant magnetic perturbations are applied in L-Mode discharges, eroded impurities can buildup in regions where an axisymmetric plasma would otherwise lead to zones of net erosion across the full toroidal length of the divertor. The reduction on the local and integrated erosion observed across a parametric study of the anomalous diffusion and impurity content in a plasma, can lead to the extension of divertor lifetimes in low power scenarios when 3D fields are applied. By contrast, in axisymmetric scenarios, most of the carbon eroded from the divertor are carried away to the far scrape-off layer.

DIII-D↗

Effects of time and temperature of firing on Fe-rich ceramics studied by Moessbauer spectroscopy and two-dimensional {sup 1}H-nuclear magnetic resonance relaxometry

The combined effects of firing temperature and soaking time on the microstructure of iron-rich porous ceramics have been studied by {sup 57}Fe-Moessbauer spectroscopy and 2D {sup 1}H nuclear magnetic resonance (NMR) relaxometry using a single-sided probe. Examining water-saturated ceramics using the relaxation correlation method, where longitudinal (T{sub 1}) and transverse (T{sub 2}) relaxation times are measured concurrently, provides information about firing-induced changes in both porosity (related to T{sub 1}) and magnetic properties (related to T{sub 2}). Comparing the information obtained from {sup 1}H-NMR analyses with that obtained from Moessbauer spectroscopy (which characterizes changes in iron-bearing species) shows that the T{sub 1}-T{sub 2} NMR correlation technique is very sensitive to even subtle modifications in the magnetic behavior of Fe-bearing species. Moreover, the single-sided NMR approach allows us to perform millimeter-scale depth-resolved measurements, which can be used to non-invasively study the microstructural heterogeneities associated with non-uniform firing effects inside ceramics. This is in contrast to Moessbauer spectroscopy, which requires that the ceramic samples be ground.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic Resonance at Short Distances

The magnetic interactions between a fermion and an antifermion of opposite electric or color charges in the $^{1}S_{0}^{-+}$ and $^{3}P_{0}^{++}$ states with $J=0$ are very attractive and singular near the origin and may allow the formation of new bound and resonance states at short distances. In the two body Dirac equations formulated in constraint dynamics, the short-distance attraction for these states for point particles leads to a quasipotential that behaves near the origin as $-\alpha ^{2}/r^{2}$, where $ \alpha $ is the coupling constant. Representing this quasipotential at short distances as $\lambda (\lambda +1)/r^{2}$ with $\lambda =(-1+\sqrt{1-4\alpha ^{2}})/2$, both $^{1}S_{0}^{-+}$ and $^{3}P_{0}^{++}$ states admit two types of eigenstates with drastically different behaviors for the radial wave function $u=r\psi $. One type of states, with $u$ growing as $r^{\lambda +1}$ at small $r$, will be called usual states. The other type of states with $u$ growing as $r^{-\lambda }$ will be called peculiar states. Both of the usual and peculiar eigenstates have admissible behaviors at short distances. Remarkably, the solutions for both sets of $^{1}S_{0}$ states can be written out analytically. The usual bound $^{1}S_{0}$ states possess attributes the same as those one usually encounters in QED and QCD, with bound state energies explicitly agreeing with the standard perturbative results through order $\alpha ^{4}$. In contrast, the peculiar bound $^{1}S_{0}$ states, yet to be observed, not only have different behaviors at the origin, but also distinctly different bound state properties (and scattering phase shifts). For the peculiar $^{1}S_{0}$ ground state of fermion-antifermion pair with fermion rest mass $m$, the root-mean-square radius is approximately $1/m$, binding energy is approximately $(2-\sqrt{2})m$, and rest mass approximately $\sqrt{2}m$. On the other hand, the $(n+1)$${}^{1}S_{0}$ peculiar state with principal quantum number $(n+1)$ is nearly degenerate in energy and approximately equal in size with the $n$$^{1}S_{0}$ usual states. For the $ {}^{3}P_{0}$ states, the usual solutions lead to the standard bound state energies and no resonance, but resonances have been found for the peculiar states whose energies depend on the description of the internal structure of the charges, the mass of the constituent, and the coupling constant. The existence of both usual and peculiar eigenstates in the same system leads to the non-self-adjoint property of the mass operator and two non-orthogonal complete sets. As both sets of states are physically admissible, the mass operator can be made self-adjoint with a single complete set of admissible states by introducing a new peculiarity quantum number and an enlarged Hilbert space that contains both the usual and peculiar states in different peculiarity sectors. Whether or not these newly-uncovered quantum-mechanically acceptable peculiar $^{1}S_{0}$ bound states and $^{3}P_{0}$ resonances for point fermion-antifermion systems correspond to physical states remains to be further investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of complications rates between multiparametric magnetic resonance imaging-transrectal ultrasound (TRUS) fusion and systematic TRUS prostatic biopsies

Purpose: The aim of this study was to compare the complication rates between transrectal ultrasound (TRUS) systematic prostate biopsy and multiparametric magnetic resonance imaging (MRI)-TRUS fusion prostate biopsy techniques. Materials and methods: This is a single-center retrospective study, institutional review board approved. Systematic TRUS and MRI-TRUS fusion prostate biopsy complication rates were compared in 967 men. A total of 319 patients were received systematic TRUS prostate biopsy and 648 patients underwent systematic TRUS + MRI-TRUS fusion prostate biopsy. Complications were divided into immediate (those that occurred during the hospital observation period) and late (those that occurred within 5 days after biopsy). Results: Seventeen complications were observed in patients who received either a systematic prostate biopsy or MRI-TRUS fusion prostate biopsy. Severe complications were not observed in both groups. Among patients who underwent systematic prostate biopsy, 6 (1.9%) cases of complications were observed and between those who received MRI-TRUS fusion prostate biopsy 11 (1.7%) cases of complications after the procedure (p = 0.873) were observed, with no statistical difference between groups. Also, no statistical differences between early and late complication groups (p > 0.999) were observed. Conclusions: The complication rates were low in both groups, with no critical clinical outcomes and no significant difference of complication rates between systematic TRUS prostate biopsy and MRI-TRUS fusion prostate biopsy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Left ventricular dimensions and mass using magnetic resonance imaging in female endurance athletes

Few published studies of left ventricular (LV) mass in female endurance athletes have been performed with M-mode echocardiography, which involves assumptions of LV geometry. Therefore, magnetic resonance imaging, a 3-dimensional technique, was used to examine LV mass, LV end-diastolic volume and mean wall thickness in female long distance runners (n = 13; mean age 29 years), cyclists (n = 12; mean age 26 years) and cross-country skiers (n = 11; mean age 24 years), and the findings were compared with sedentary control subjects (n = 10; mean age 27 years) matched for height and body weight. The physical characteristics for all subjects included height (mean 166 cm, and body weight (mean 56 kg). The percent body fat (mean 11.7) and maximal oxygen uptake (VO2max, mean 63 ml.kg-1.min-1) were similar (p greater than 0.05) among all athletic groups, but significantly different from the control group (body fat, mean 22.5%; VO2max, mean 35 ml.kg-1.min-1). LV mass (mean 159 kg), LV end-diastolic volume (mean 122 ml), and mean wall thickness (mean 11.5 mm) were also similar among the athletic groups and significantly larger than the following control values: LV mass (mean 115 g), LV end-diastolic volume (mean 93 ml) and mean wall thickness (mean 9.8 mm). Ratios of LV mass to lean body weight were similar among all athletic groups, although athletic groups had larger ratios (p less than 0.05) than the sedentary control subjects. LV mass/LV end-diastolic volume ratio was similar (p greater than 0.05) among all groups.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Cardiopulmonary↗

Stochastic fluctuation and transport of tokamak edge plasmas with the resonant magnetic perturbation field

Here we present that a statistical method known as the complexity–entropy analysis is useful to characterize a state of plasma turbulence and flux in the resonant magnetic perturbation (RMP) edge localized mode (ELM) control experiment. The stochastic pedestal top temperature fluctuation in the RMP ELM suppression phase is distinguished from the chaotic fluctuation in the natural ELM-free phase. It is discussed that the stochastic temperature fluctuation can be originated from the narrow layer of the field penetration on the pedestal top. The forced magnetic island can emit the resonant drift wave of comparable sizes (relatively low-k) in the RMP ELM suppression phase, and it can result in the generation of stochastic higher wavenumber fluctuations coupled to tangled fields around the island. The analysis of the ion saturation current measurement around the major outer striking point on the divertor shows that it also becomes more stochastic as the stronger plasma response to the RMP field is expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A biofilm microreactor system for simultaneous electrochemical and nuclear magnetic resonance techniques

In order to fully understand electrochemically active biofilms and the limitations to their scale-up in industrial biofilm reactors, a complete picture of the microenvironments inside the biofilm is needed. Nuclear magnetic resonance (NMR) techniques are ideally suited for the study of biofilms and for probing their microenvironments because these techniques allow for non-invasive interrogation and in situ monitoring with high resolution. By combining NMR with simultaneous electrochemical techniques, it is possible to sustain and study live electrochemically active biofilms. Here, we introduce a novel biofilm microreactor system that allows for simultaneous electrochemical and NMR techniques (EC-NMR) at the microscale. Microreactors were designed with custom radiofrequency resonator coils, which allowed for NMR measurements of biofilms growing on polarized gold electrodes. For an example application of this system, we grew Geobacter sulfurreducens biofilms. NMR was used to investigate growth media flow velocities, which were compared to simulated laminar flow, and electron donor concentrations inside the biofilms. We use Monte Carlo error analysis to estimate standard deviations of the electron donor concentration measurements within the biofilm. The EC-NMR biofilm microreactor system can ultimately be used to correlate extracellular electron transfer rates with metabolic reactions and explore extracellular electron transfer mechanisms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗