Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAINTAINABILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Cost-Benefit Analysis of Grid-Supportive Loads for Fast Frequency Response

Flexibility in inverter-based loads could be used to support the converter-dominated power grid by offering a rapid, autonomous, and adjustable power reserve during system transients to help maintain system stability. Based on technical potential, ancillary service (AS) value, and implementation costs, this study illustrates the cost-benefit analysis of grid-supportive loads (GSLs) for the supply of fast frequency response (FFR). The net benefit for each GSL is demonstrated using a case study and relevant data sources. The findings suggest that implementation costs for enabling GSL features are low compared to the value that grid operators get from the acquisition of responsive reserve services. The authors believe that, given the rising popularity of renewable energy sources, GSLs can be a useful tool for grid stability in low-inertia systems.

cost-benefit analysis↗

Study of Seamless Microgrid Transition Operation Using Grid-Forming Inverters

This paper investigates operational techniques to achieve seamless (smooth) microgrid (MG) transitions by dispatching a grid-forming (GFM) inverter. In traditional approaches, the GFM inverter must switch between grid-following (GFL) and GFM control modes during MG transition operation. Today's inverter technology allows GFM inverters to always operate in GFM control mode, so it is worth exploring how to use them to achieve smooth MG transition operation. This paper proposes three operational techniques: a traditional scheme of switching between GFL and GFM control; a new scheme of consistent GFM control and shifting the droop intercept up before islanding operation; and a new scheme of consistent GFM control and shifting the droop intercept up before synchronization operation. A full hardware setup is established to compare the three techniques and showcase their implementations in real-world applications. The results show that the third technique outperforms the others and exhibits the best transition performance because the GFM inverter maintains the same operating points during the transition operation. Therefore, we conclude that ensuring smooth MG transition operation requires that the GFM inverter(s) maintain the same operating points (v, f, P, Q, and phase angle) during the transition operation in addition to minimizes the point of common coupling power flow.

grid-forming control↗

Operation and Control of Electric Vehicle Charger with Enhanced Dynamic Performance Under Non-Ideal Grid Voltage Condition

This paper presents a three-phase electric vehicle charger connected to the grid, featuring multiple boost converters on the DC side, specifically designed to ensure smooth, oscillation-free power transfer during unsymmetrical voltage sags. Precise control mechanisms are implemented on the boost converter side to regulate both voltage and current on the electric vehicle side, thereby maintaining optimal charging conditions. The control architecture for both the grid-connected and boost converter components is based on the Lyapunov energy function, which is employed to achieve superior dynamic performance and stability. The system's robustness and reliability are demonstrated through its ability to maintain stable operation and efficient power transfer despite fluctuations in grid conditions. Furthermore, the implementation of Lyapunov-based control ensures rapid response and minimal energy loss, enhancing the overall efficiency of the system. To validate the effectiveness of this approach, a comprehensive model of the system was developed and tested using MATLAB/Simulink, with detailed computer simulations conducted across various significant case studies.

DC-DC boost converter↗

DS-GL: Advancing Graph Learning via Harnessing the Power of Nature within Dynamic Systems

With the rapid digitization of the world, an increasing number of real-world applications are turning to nonEuclidean data, modeled as graphs. Due to their intrinsic high complexity and irregularity, learning from graph data demands tremendous computational power. Recently, CMOS-compatible Ising machines, i.e., dynamic systems composed of CMOS components, have emerged as a new approach that harnesses the inherent power of natural annealing within dynamic systems to efficiently resolve binary optimization problems and have been adopted for traditional graph computation, such as max-cut. However, when performing complex Graph Learning (GL) tasks, Ising machines face significant hurdles: (i) they are inherently binary and thus ill-suited for real-valued problems; (ii) their expensive all-to-all coupling network that guarantees effective natural annealing poses daunting scalability concerns. To address these challenges, this paper proposes a nature-powered graph learning framework dubbed DS-GL, which is the first effort to transform the process of solving graph learning problems into the natural annealing process within a parameterized dynamic system embodied as a CMOS chip. To tackle the two major hurdles, DS-GL first augments the Ising machine architecture to modify the self-reaction term of its Hamiltonian function from linear to quadratic, effectively serving as an energy regulator. This adjustment maintains the system’s original physical interpretation while enabling it to process continuous, real-valued data. Second, to address the scaling issue, DS-GL further upgrades the real-valued dense Ising machine by decomposing it into a mesh-based multi-PE dynamic system that supports efficient distributed spatial-temporal co-annealing across different PEs through sparse interconnects. By exploiting the inherent sparsity and component structures in real-world graphs, DS-GL is able to map complex graph learning tasks onto the scalable dynamic system while maintaining high accuracy. Evaluations with three diverse GL applications across six real-world datasets, including traffic flow and COVID-19 prediction, show that DS-GL can deliver from 102× to 106× speedups and 500× energy reduction over Graph Neural Networks on GPUs, with 5% - 20% accuracy enhancement.

Song, Ruibing↗

Double Deep Q-Networks for Optimizing Electricity Cost of a Water Heater

Electric water heaters represent 14% of the electricity consumption in the residential buildings and the cost associated with domestic water heating account for a good portion of the household expenses in the United States. In this context, intelligent control of water heaters gained a lot of research attention. In recent years, a significant number of intelligent water heater controllers, with various methods and intended uses, have been proposed. However, existing studies are mostly model-based approaches that require an accurate modelling of the water heater. Towards addressing this research gap, this paper presents a model-free reinforcement learning-based controller for a day-ahead price market. The controller aims to minimize the cost of domestic water heating while maintaining the user comfort. The results showed that the developed controller can help save energy cost while maintaining the temperatures within the desired comfort band.

Amasyali, Kadir↗

Mitigating Voltage Instability in the Saudi Grid for a Decarbonized, Fully Solar Power System

Lately, solar photovoltaic (PV) has received significant interest due to its economic and environmental benefits. As the integration of renewable energy sources (RES) increases into existing power grids, challenges such as the decrease in short circuit ratio (SCR) are introduced. Here, this paper investigates a case study of the Saudi power grid, examining the voltage stability as the grid transitions from traditional power generation to 100% penetration of solar PV gradually. Moreover, the paper explores the relationship between the increase in solar penetration and the potential effects on the short circuit MVA (SCMVA), which could significantly impact the overall SCR of the system. To meet the North American Electric Reliability Corporation (NERC) recommendation of maintaining SCR at a particular level, synchronous condensers (SC)s were integrated into the grid. The effectiveness of utilizing SCs to maintain the system voltage at optimal levels in a fully solar grid is also considered. In addition, this paper covers the weak grid analysis via utilizing the Newton-Raphson load flow method, along with PV and QV curve analyses. The purpose behind that is to determine weak bus locations in need of voltage improvements, and to meet the amount of reactive power to be injected. Finally, the amount of power being delivered by SCs will be added progressively in three scenarios to show the enhancements on SCR more precisely.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Power Sharing Speed Compensation in On-road Wireless EV Charging Systems

Dynamic wireless charging of electric vehicles (EV) is an emerging technology with the potential to address range anxiety and reduce the size of batteries or provide charge-sustaining operation. Charging demand for dynamic wireless charging systems (DWCS) varies greatly in response to location-specific traffic behaviors including the number and speed of vehicles. This paper highlights the potential reduction of load variation with speed compensation and simulates opportunities to maximize the number of cars charged concurrently through “power sharing” or altering power output to slower cars while maintaining a maximum delivered energy. An improved sub-minute model for synthetic traffic is proposed to effectively model DWCS load on high speed roadways and a power electronics model is created based on an existing prototype developed by ORNL to investigate the potential for power sharing. Reductions in the average speed of traffic can greatly increase instantaneous DWCS load by as much as 26%, complicating capacity sizing. Parametric studies with a LCC-S power electronics model shows feasible power reduction of more than 20%, while maintaining a maximum achievable efficiency greater than 90%. Speed compensation on a roadway with large speed variation can reduce average power expected by 21% and increase the maximum number of cars charged simultaneously by 30%. The application of power sharing may significantly reduce load variability due to speed, allow for increased car hosting capability, and guarantee a maximum energy delivered.

Lewis, Donovin D.↗

Fiber-Optic Silicon Fabry-Perot Interferometric Bolometer: The Influence of Mechanical Vibration and Magnetic Field

Plasma radiation plays an important role in the operation and control of magnetic confinement fusion and is typically measured by bolometers. Here, we study the influence of mechanical vibration and magnetic field, which are typically present in magnetic confinement fusion devices, on the performance of a fiber-optic bolometer (FOB) based on silicon Fabry-Perot interferometer (FPI) demodulated by a scanning diode laser. It is found that both the vibration and magnetic field could cause large noise due to the birefringence of the silicon FPI. To mitigate the birefringence effects, we demonstrated two effective methods: polarization maintaining FOB and polarization scrambling. We show that two methods can be effective in mitigating the effect caused by the sensor birefringence: (1) replacing the regular single-mode fiber in the FOB system with polarization-maintaining fiber and (2) using a polarization scrambler after the laser source. For both methods, no significant increase in the noise was observed in the vibration and magnetic field tests. Finally, our research highlights the importance of the polarization management for the FOB systems toward their practical applications in magnetic-confinement fusion systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Lattice-Mismatched GaInAsP for Radiation Hardness

We develop lattice-mismatched GaInAsP as an alternative alloy to pure As-based alloys currently used in III-V multijunction solar cells. Increasing the alloy phosphorous and indium content while maintaining an optimal bandgap may allow high efficiency multijunction devices with increased radiation hardness. Here, 1.0-eV GaInAsP is developed and implemented into single and multijunction solar cell devices. The lattice-mismatched GaInAsP must be grown strain free, and the subcell thickness must be maintained below the thickness where surface-driven phase separation occurs. As observed in transmission electron microscopy and cathodoluminescence imaging, phase separation strengthens in the GaInAsP layer and leads to interfacial defect formation when the cell thickness is too great. We show single junction 1.0-eV Ga 0.5 In 0.5 As 0.7 P 0.3 with excellent carrier collection and a bandgap-voltage offset of 0.40 V. This material quality approaches that of 1.0-eV Ga 0.7 In 0.3 As used in inverted metamorphic multijunction devices, but has increased phosphorus content and consequently is expected to have a higher radiation resistance. We incorporate the 1.0-eV GaInAsP subcell into a 3-junction inverted metamorphic solar cell to test the performance of the subcell in a multijunction. No additional loss is observed upon integration into a multijunction cell: both the carrier collection and voltage of the GaInAsP subcell are unchanged from single junction devices. While further materials development and radiation testing is still required, these preliminary results indicate that lattice-mismatched GaInAsP can be effectively used in multijunction solar cells to replace radiation-soft materials.

14 SOLAR ENERGY↗

Isolating p- and n-Doped Fingers With Intrinsic Poly-Si in Passivated Interdigitated Back Contact Silicon Solar Cells

Polycrystalline silicon on silicon oxide (poly-Si/SiO x ) passivating contacts enable ultra high efficiency interdigitated back contact silicon solar cells. To prevent shunt between n- and p-type doped fingers, an insulating region is required between them. We evaluate the use of intrinsic poly Si for this isolation region. Interdigitated fingers were formed by plasma deposition of doped hydrogenated amorphous silicon through mechanically aligned shadow masks, on top of a full-area intrinsic amorphous silicon layer. High temperature annealing then crystallized the a-Si:H to poly Si and drove in the dopants. Two mechanisms were identified which cause contamination of the intrinsic poly Si gap during processing. During deposition of doped fingers, we show using secondary ion mass spectrometry and conductivity measurements that the intrinsic gap becomes contaminated by doped a-Si:H tails several nanometers thick to concentrations of ~10 20 cm -3 . Another source of contamination occurs during high-temperature annealing, where dopants desorb from doped regions and readsorb onto intrinsic a Si:H. Both pathways reduce the resistivity of the intrinsic gap from ~10 5 Ω·cm to ~10 -1 Ω·cm. We show that plasma etching of the a-Si:H surface before crystallizing with a capping layer can eliminate the contamination of the intrinsic poly-Si, maintaining a resistivity of ~10 5 Ω·cm. Lastly, this demonstrates masked plasma deposition as a dopant patterning method for Si solar cells.

14 SOLAR ENERGY↗

Comparison of Probabilistic Forecasts for Predictive Voltage Control

This paper explores predictive cooperative voltage control in distribution systems with highly variable sources such as photovoltaics (PV). The goal is to maintain the voltage profile within the limits despite the fluctuations due to sudden changes in solar power generation. The predictive voltage control method relies on probabilistic solar power and load forecasts to select the optimum Voltage Regulator (VR) taps appropriately. VR taps are selected to minimize the risk of voltage violation. A modified version of the IEEE 123 system is used as the case study. A 100% penetration of solar power is assumed for the distribution system with profiles for solar generation and loads added to the system. Three different probabilistic forecast models (Quantile Regression (QR), Gaussian distribution and volatility forecasting using Generalized Autoregressive Conditional Heteroskedasticity (GARCH)) are explored in this study. The results for the VR taps and Voltage Deviation Index (VDI) are compared to find the most effective forecast model.

Panamtash, Hossein↗

Ensemble Learning, Prediction and Li-Ion Cell Charging Cycle Divergence

In recent years, the pervasive use of lithium ion (Li-ion) batteries in applications such as cell phones, laptop computers, electric vehicles, and grid energy storage systems has prompted the development of specialized battery management systems (BMS). The primary goal of a BMS is to maintain a reliable and safe battery power source while maximizing the calendar life and performance of the cells. To maintain safe operation, a BMS should be programmed to minimize degradation and prevent damage to a Li-ion cell, which can lead to thermal runaway. Cell damage can occur over time if a BMS is not properly configured to avoid overcharging and discharging. To prevent cell damage, efficient and accurate cell charging cycle characteristics algorithms must be employed. In this paper, computationally efficient and accurate ensemble learning algorithms capable of detecting Li-ion cell charging irregularities are described. Additionally, it is shown using machine and deep learning that it is possible to accurately and efficiently detect when a cell has experienced thermal and electrical stress due to cell overcharging by measuring charging cycle divergence.

25 ENERGY STORAGE↗

Evaluation of Horizon of Viability Optimization Engine for Sustained Power to Critical Infrastructure: Preprint

In the aftermath of increasingly frequent catastrophic events, a typical scenario is Critical Infrastructure (CI) units being supported by available backup sources with a weak power grid that can be intermittent or absent. Such a scenario is significantly challenging in the sense of reliable supply of power to CI units. In this article, an intelligent optimization scheme termed as Horizon of Viability (HoV) engine is developed to guarantee the viability of a sustained reliable supply of power to the CI units over a time-horizon. The proposed HoV engine generates a cost-optimal portfolio of the locally available generation sources and the loads over a time horizon using a mixed-integer convex programming problem. A Controller hardware-in-the-loop (CHIL) platform is developed to evaluate the control performance of the HoV engine. The experimental results corroborates the efficacy in maintaining the viability of the CI units after a grid interruption event. Further, the proposed HoV optimization scheme performs better compared to existing net-load management schemes in the literature.

disaster resiliency↗

Control and Simulation of a Grid-Forming Inverter for Hybrid PV-Battery Plants in Power System Black Start

Power system restoration is an important part of system planning. Power utilities are required to maintain black start capable generators that can energize the transmission system and provide cranking power to non-blackstart capable generators. Traditionally, hydro and diesel units are used as black start capable generators. With the increased penetration of bulk size solar farms, inverter based generation can play an important role in faster and parallel black start thus ensuring system can be brought back into service without the conventional delays that can be expected with limited black start generators. Inverter-based photovoltaic (PV) power plants have advantages that are suitable for black start. This paper proposes the modeling, control, and simulation of a grid-forming inverter-based PV-battery power plant that can be used as a black start unit. The inverter control includes both primary and secondary control loops to imitate the control of a conventional synchronous machine. The proposed approach is verified using a test system modified from the IEEE 9-bus system in the time-domain electromagnetic transient simulation tool PSCAD. The simulation results shows voltage and frequency stability during a multi-step black-start and network energization process.

Nguyen, Quan H.↗

Cloud-based Testbed for Adaptive Under-Frequency Load Shedding with High DER Penetration

Increasing penetration of distributed energy resources and behind-the-meter renewables may soon disrupt the efficacy of critical protection schemes, such as under-frequency load shedding (UFLS). Improved data exchange and coordination across the transmission-distribution boundary will be required to maintain reliability of bulk electric system. Standards-based data integration platforms using agreed-upon semantic vocabularies, such as the Common Information Model, will be key to enabling adaptive protection schemes requiring synthesized data from both the bulk power system and behind-the-meter resources. This paper introduces a cloud-based open-source data integration environment and UFLS clustering algorithm being developed to enable adaptive relay coordination between transmission and distribution utilities in the state of Vermont.

Anderson, Alexander A.↗

Predictive and Cooperative Voltage Control with Probabilistic Load and Solar Generation Forecasting

This paper proposes predictive cooperative voltage control method in a power system with high penetration of photovoltaic (PV) units. Cooperative distributed control of the reactive power output of PV inverters is coordinated with operation of voltage regulators (VRs) to maintain system voltages within an appropriate bandwidth. Probabilistic forecasting of the solar power generation and the loads is applied to estimate voltage changes which, in turn, are used to set the VR tap positions for preventing large voltage fluctuations with the lowest risk considering the voltage distribution estimation. The fine tuning of voltage adjustment is achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on the modified IEEE 123-node test feeder with high PV penetration using real insolation data and with constant loads replaced by several different load profiles. Simulation results demonstrate the effectiveness of the coordinated approach for voltage control with cooperative PV and predictive VR controls taking into account probabilistic load and solar power forecasts.

Cooperative Control↗

Movement of Cracked Silicon Solar Cells During Module Temperature Changes

Cracks in crystalline silicon solar cells can lead to substantial power loss. While the cells' metal contacts can initially bridge these cracks and maintain electrical connections, the bridges are damaged by mechanical loads, including those due to temperature changes. We investigated the metallization bridges that form over cracks in encapsulated silicon solar cells. Microscopic characterization showed that the crack in the silicon can immediately propagate through the metal grid, but the grid can maintain electrical contact once the load is removed. We also quantified the movement of the cell fragments separated by a crack as a function of temperature. Cell fragments are free to move diagonally and to rotate, so the change in gap across the crack during a temperature change varies along the length of the crack. In one sample, we showed that a 10 degrees C temperature change, causing a 2 um increase in the separation of cell fragments, was sufficient to cause a reversible electrical disconnection of metallization bridging a crack.

14 SOLAR ENERGY↗

Improving Performance of III-V Solar Cells Grown on Spalled Germanium with Ex Situ Substrate Planarization

Controlled spalling allows removal of devices and provides an opportunity for cost reduction through substrate reuse. However, the fracture-based process can leave behind morphological surface features, notably river lines, that can disrupt epitaxial growth and degrade device performance. We investigate the viability of various wet etch chemistries to planarize river lines to ensure high-quality device growth and performance without mechanical repolishing, and so maintain a route towards cost-effective reuse. Etching in a HF: HNO 3 :CH 3 COOH solution effectively planarizes river lines and produces a surface that yields devices with equivalent performance to those grown on epi-ready Ge wafer surfaces. Further studies will focus on optimizing etch composition, temperature, and time to minimize material removal while maintaining a suitable surface for high-quality epitaxy.

germanium↗